Declaration of conformity ................................................ 43
Introduction
Introduction
Information on User Guide
Dear customer,
Thank you for purchasing this CO alarm. This device is a product that has been
built using state-of-the-art technology.
This user guide contains important information on starting operation and using
the device. Store this user guide in a safe place for future reference. These
instructions are a part of this product – bear this in mind if you pass on this
product to others.
You will find a list of contents with the corresponding page numbers in the
contents.
Intended use
Only use the device for the purpose which it was designed and built for. Any
other use is not considered to be the intended use.
This device may only be used for the following purpose:
Carbon monoxide detection in private households
6
Introduction
Limitation of liability
Please observe the notes and instructions in this user guide! If you do not follow
these instructions, any guarantee claim is invalidated. No liability can be
accepted for resulting damage. No part of the product may be changed or
modified in any way.
Everything possible has been done to ensure that the content of these
instructions is correct. However, neither the author nor ABUS August Bremicker
Söhne KG, Altenhofer Weg 25, 58300 Wetter can be held liable for loss or
damages caused by incorrect or improper use or failure to observe the safety
instructions and warnings.
Indicates a risk of injury or health
hazards caused by electrical voltage.
Important
Indicates possible damage to the
device/accessories.
Note
Indicates important information.
Safety information
Explanation of symbols
The following symbols are used in this manual and on the device:
8
Caution
All guarantee claims are invalid in the event of damage caused by
non-compliance with these instructions.
We cannot be held liable for resulting damage.
Caution
In the event of personal or material damage caused by improper
operation or non-compliance with the safety information, we
cannot be held liable.
All guarantee claims are void in such cases.
Safety information
General
Before using this device for the first time, please read the following instructions
carefully and observe all warning information, even if you are familiar with the
use of electronic devices.
Store these instructions in a safe place for later use.
If you sell or pass on the device on to third parties, you must include these
instructions with the device.
9
Safety information
The batteries must not be directly exposed to heat or sunlight,
and must not be stored in a place with a very high
temperature.
The batteries must not be burned.
The batteries must not come into contact with water.
The batteries must not be dismantled, pierced or otherwise
damaged.
The battery contacts may not be short-circuited.
The batteries must be kept away from small children.
The batteries cannot be recharged.
Do not dispose of the batteries in domestic waste.
Battery warning information
The device is supplied with 9 V direct current from a 9 V alkaline block battery.
To guarantee a long service life and avoid fire and injury, please note the
following:
10
Keep packaging material and small parts away from children -
danger of suffocation!
Remove all packaging material before using the device.
Do not cover the device.
Do not paint over the device or cover it with wallpaper.
Do not, on any account, open or repair the device. Failure to
observe this instruction will invalidate the warranty.
Do not use the device if it has been dropped or damaged in
any other way.
Safety information
Packaging
Functioning of the device
To ensure that the device functions correctly, please note the following points:
11
Scope of delivery | Technical data
ABUS CO alarm
Mounting material
9 V alkaline block battery
User guide
Power supply
DC 9 V alkaline block battery
- Duracell 9 V Alkaline (6LR61, MN1604)
- GP 9 V Alkaline (6F22, 1604S)
Trigger sensitivity
Conforms to EN 50291-1:2010 + A1:2012
CO
concentration
No alarm
within
Alarm at
the latest
after
30 ppm
120 min - 50 ppm
60 min
90 min
100 ppm
10 min
40 min
300 ppm
-
3 min
Scope of delivery
Technical data
12
Sensor type
Electrochemical
Sensor lifespan
7 years
Sensor range
0 to 1,000 ppm
Detection range
max. 60 m²
Power consumption
< 80 µA (Ø standby) || < 25 mA (Ø alarm)
Operating temperature
0° to 40° C
Humidity
30% to 95% (non-condensing)
Sound pressure
> 85 dB (A)@1 m (3.5 +/- 0.5 kHz pulsing)
Alarm muting
5 minutes
Installation location
Wall
According to EN 50291, the COWM300 ABUS CO alarm is
designed and approved exclusively for detecting CO (carbon
monoxide) in private homes.
Application in industrial facilities, offices, boats, caravans or
mobile homes is therefore not permitted.
Functional principle and features
Functional principle and features
13
Functional principle and features
The CO alarm is not a substitute for smoke, fire or other
alarms.
It does not detect smoke, heat or other gases.
In addition, the electrochemical sensor can only detect CO on
time in a limited area (max. 60 m², depending on the
environmental conditions).
The battery-operated ABUS CO alarm (COWM300) detects carbon
monoxide (CO) in even low concentrations, then gives off an acoustic as
well as optical signal.
The purpose of the CO alarm is to protect persons against the acute
effects of carbon monoxide. However, it cannot prevent the chronic affects
of carbon monoxide exposure or offer persons with special risks complete
safety.
14