403 (W) x 482 (D) x 222 (H), body of the machine
Q: Is there any restriction on the sort of cut sheets that I may use with the FDA 415 model?
A: FDA 415 only operates on cut sheets that whose minimum applications are 4 by 5 inches to a maximum of 11 by 17 inches and has a paper weight of 64 to 157 g m/2.
Q: Are there any restrictions on the supplying cut column size?
A: Yes there is, normally speaking cut column size can be estimated and altered anywhere between 2.5 to 99 inches, supplied in steps of 0.1 inches using the length switch.
Q: If there is a paper jam situation, what would be the outcome if the situation arose?
A: In that scenario, the device would self-stop and a jam would let a yellow light slip and blow up. Jammed pages would have to be torn out in order to carry on with the designated task on hand.
Q: Can the feed pressure be changed?
A: Three positions on almost all grade thicknesses allows the feed pressure to be moved with cut sheets of normal thickness.
Q: How rapid is it possible to cut using FDA 415?
A: FDA 415 has a ratio of 140 over 90 which translates to having a cutting speed of 140 sheets per minute on high speed and 90 sheets per minute on low speed .
Q: Does the machine have a sensor?
A: Yes, because it aims to provide maximum safety, the machine has a safety cover that has an interlocking device, which will stop the movement of the machine as soon as the cover is removed.
Q: What electrical specifications are required for the FD 415 to work properly?
A: This model works with a rated voltage of 240 volts and 60Hz.
Q: What kinds of supplies are given together with the FD 415?
A: The accessories provided with this machine include: an electric power cord of approximately six feet, two guides for receiving paper, another plate, its manual for guidance.
Q: What is the maximum quantity of papers the tray can accommodate in case it gets too full?
A: The maximum capacity for a tray which is capable of accommodating 500 sheets is for 64 g/m² paper.