ABB S3, S4, S5, S6, S7 Accessories Catalog

K5S1
Electrical accessories
Isomax
MCCBs
Shunt trip, undervoltage release S3 – S7
Shunt trips
Factory installation Field installation Voltage Catalog number List Catalog numbers List
suffi x
480VAC/250VDC S1 K5S1 K7S1 240VAC S2 K5S2 K7S2 120VAC/125VDC S4 $ 430 K5S4 K7S4 $ 415 48VDC S7 K5S7 K7S7 24VAC/VDC S8 K5S8 K7S8 12VDC S9 K5S9 K7S9
Low power shunt trips
Factory installation Field installation Voltage Catalog number List Catalog numbers List
suffi x
24VDC SA 120VAC SB K5SB K7SB
For remote opening of circuit breaker and includes internal cut-off switch to protect solenoid. All shunt trips are left pole mounted and can not be used with UVRs. Except for 12VDC, all shunt trips are approved for use in GF systems. Shunt trips must be ordered with correct connector.
1 price adder S3 – S4 – S5 S6 – S7 price
1 price adder S3 – S4 – S5 S6 – S7 price
K5SA K7SA
$ 430
15
$ 415
S5 with K5S2
K5U1
K6C-SUP
Shunt trip connectors (required)
circuit breaker
Fixed mounted All included K6C-SU K7C-SU Plug-in/Draw-out All included K6C-SUP K7C-SUP
Electrical specifi cations – shunt trips (standard)
12, 24, 48, 125, 250 VDC – For S3-S5 100 VA~/120W–
P Instantaneous duty For S6-S7 150 VA~/150W–
Type Factory
24, 120, 240, 480VAC ~ 50/60 Hz
V
Voltage
installation
1 S3 – S4 – S5 – S6 S7 List price
Field kit catalog number
$ 15
Undervoltage releases
Factory installation Field installation Voltage Catalog number List Catalog numbers List
suffi x
480VAC U1 K5U1 K7U1 240VAC U2 K5U2 K7U2 120VAC U4 K5U4 K7U4 24VAC U3 $ 430 K5U3 K7U3 $ 415 250VDC U5 K5U5 K7U5 125VDC U6 K5U6 K7U6 48VDC U7 K5U7 K7U7 24VDC U8 K5U8 K7U8
Will trip CB when connected voltage drops to 35-70% of UVR voltage rating. Will allow CB to close (ON) when voltage is approximately 85% of rated voltage. All UVRs are left pole mounted and can not be used with shunt trips. UVRs must be ordered with correct connector.
1 price adder S3 – S4 – S5 S6 – S7 price
Undervoltage release connectors (required)
circuit breaker
Fixed mounted All included K6C-SU K7C-SU Plug-in/Draw-out All included K6C-SUP K7C-SUP
Electrical specifi cations – UVR & low power shunt trips V
24, 48, 125, 250 VDC – For S3-S5 6 VA~/3W–
P Continuous duty For S6-S7 10 VA~/4W–
Type Factory
24, 120, 240, 480 VAC ~ 50/60 Hz
Voltage
installation
1
S3 – S4 – S5 – S6 S7 List price
Field kit catalog number
$ 15
15
1 For factory installation add suffi x given to end of circuit breaker catalog number per accessory format.
Low Voltage Products & Systems 15.89
ABB Inc. • 888-385-1221 • www.abb-control.com 1SXU 000 023 C0201
Discount schedule SA
Isomax
MCCBs
15
Electrical accessories
Auxiliary contacts S3 – S7
Auxiliary contacts — S3 – S7
Factory installation Field installation
Contacts Catalog number List
suffi x
2 Form Cs A $ 275 K5AS K7AS $ 260 1 BA & 1 C BA
1 B BA & 1A+1B BA3 K7BA-3 The auxiliary contacts are accessory contacts for the in di ca tion of circuit breaker open-closed or tripped. Bell alarm contacts
(B.A.) can be used to indicate circuit breaker tripping. All contacts are right pole mounted.
1
price adder S3 – S4 – S5 S6 – S7 price
Catalog numbers
K5BA K7BA
365
List
350
15
K5AS
K6C-ABP
Auxiliary contact connectors (required) — S3 – S7
Type Factory circuit breaker
Fixed mounted All included K6C-AB K7C-AB Plug-in/Draw-out All included K6C-ABP K7C-ABP
Electrical specifi cations
Voltage Maximum contact amperage rating
125 VDC 0.3 A
250 VDC 0.15 A 250 VAC 6 A
N.O. = contact is open as circuit breaker is open N.C. = contact is closed when circuit breaker is open B.A. = will open/close only when circuit breaker trips
Voltage
installation
1
S3 – S4 –- S5 – S6 S7 List price
Field kit catalog number
$ 15
S5 with K6C-AB
1 For factory installation add suffi x given to end of circuit breaker catalog number per accessory format. 2 Not UL approved for fi eld installation.
15.90 Low Voltage Products & Systems
1SXU 000 023 C0201 ABB Inc. • 888-385-1221 • www.abb-control.com
Discount schedule SA
K5M2
S4 with K5M2
Electrical accessories
Isomax
MCCBs
Motor operators, stored energy motor operators S3 – S7
Motor operator
Catalog number List Voltage
240VAC/250VDC K5M2 120VAC/125VDC K5M4 48VDC K5M7 24VDC K5M8
For remote control of circuit breaker opening and closing. Complete with manual op er at ing lever, padlock device and emergency opening push-button. When ordering the con nec tor always specify type and ver sion of the circuit-break er. The following options are also available: – key lock for open position – key lock for open position of two or more circuit breakers (using the same key for groups of circuit breakers)
Motor operator connectors (required)
Type Field kit catalog number List circuit breaker
Fixed mounted All K6C-M Plug-in/Draw-out All K6C-MP
Electrical specifi cations
120, 240VAC ~ 50/60 Hz
V
24, 48, 125, 250 VDC – P inrush 500 VA~/500W–
P normal 350 VA~/500W– Close time 0.1 s
Open time 0.1 s
S3 – S4 – S5 price
Voltage
S3 – S4 – S5 price
15
$ 678
$ 15
K6C-M
K6M2
Stored-energy motor operator
Catalog number List Voltage
240VAC/250VDC K6M2 K7M2 120VAC/125VDC K6M4 K7M4 48VDC K6M7 K7M7 24VDC K6M8 K7M8
• Stored-energy motor operator with springs automatically pre-loaded by motor.
• Complete with shunt opening and closing release, and com part ment door fl ange.
• When ordering the connector always specify type and version of the circuit-breaker.
• The following options are also available: – key lock for open position – key lock for open position of two or more circuit-breakers (using the same key for groups of circuit-break ers).
S6 S7
price
$ 2407
Stored-energy motor operator connectors (required)
Type circuit breaker
Fixed mounted All K6C-M K7C-M Plug-in/Draw-out All K6C-MP K7C-MP
Electrical specifi cations
120, 240 VAC ~ 50/60 Hz
V
24, 48, 125, 250 VDC – P inrush 660 VA~/600W–
P normal 180 VA~/180W– Close time 0.09 s
Open time 1.2 s Reset time 2.0 s
Field kit catalog number
Voltage
S6 S7 price
List
$ 15
15
S7 with K7M4
Low Voltage Products & Systems 15.91
ABB Inc. • 888-385-1221 • www.abb-control.com 1SXU 000 023 C0201
Discount schedule SA
Isomax
MCCBs
15
K4ET-250
K4TB
External accessories
Lugs and termination kits S3 – S7
Standard cable lug kits
Set of 2 Set of 3 For breakers Amps
S3 60 14AWG – 2AWG K3TA-2 $ 4 K3TA $ 6 S3 – S4 100 14AWG – 1/0 K4TB-2 4 K4TB 6 S3 – S4 150 2AWG – 4/0 K4TC-2 4 K4TC 6 S3 – S4 – S5 225 4AWG – 300kcmil K4TD-2 10 K4TD 15 S4 250 6AWG – 350kcmil K4TE-2 20 K4TE 30
S5 300 250kcmil 500kcmil K5TF-2 30 K5TF 45 S5 400 (2) 3/0 – 250kcmil K5TG-2 S6 600 S6 800 (3) 2/0 – 400kcmil K6TJ-2 S7 1200 (4) 4/0 – 500kcmil K7TK-2 120 K7TK 180
Standard cable lugs, for use on line and load side of circuit breaker. Suitable for use with Cu or Al. Special versions available with taps and screws for control wire connection. Note: S6 and S7 lugs are Al9Cu (90°C); all others Al7Cu (75°C).
1
(2)
Standard cable lug kits with control power taps
Set of 2 Set of 3 For breakers Amps
S3 – S4 100 14AWG – 1/0 K4TB-2C $ 8 K4TBC $ 12 S3 – S4 150 2AWG – 4/0 K4TC-2C 8 K4TCC 12 S3 – S4 – S5 225 4AWG – 300kcmil K4TD-2C 14 K4TDC 21 S4 250 6AWG – 350kcmil K4TE-2C 24 K4TEC 36
S5 300 250kcmil 500kcmil K5TF-2C 34 K5TFC 51 S5 400 (2) 3/0 – 250kcmil K5TG-2C S6 600 (2) 250kcmil – 500kcmil K6TH-2C 54 K6THC 81 S6 800 (3) 2/0 – 400kcmil K6TJ-2C S7 1200 (4) 4/0 – 500kcmil K7TK-2C 124 K7TKC 186
1
Wire
catalog
range
number
250kcmil – 500kcmil K6TH-2 50 K6TH 75
Wire
catalog
range
number
List
catalog
price
number
2 30 K5TG2 45
2 90 K6TJ2 135
List
catalog
price
number
2 34 K5TGC2 51
2 94 K6TJC2 141
List
price
List
price
15
K4TES
K4TER
K4TN
Extended front termination kits
Suitable for Maximum Set of 6 List use with amps catalog number price
S3 – S4 250 K4ET-250 $ 46 S5 400 K5ET-400 114 S6 630 K6ET-600 150 S6 800 K6ET-800 170 S7 1250 K7ET-1250 240
For adding onto standard circuit breaker front terminals, extending available connection area for user termination. Suitable for spaded cable or bus connection. S3 – S5 include terminal covers.
Saddle cable lug kits (Cu cable only)
Suitable for Max Wire Set of 6 List use with amps range catalog number price
S3 – S4 250 14AWG – 250kcmil K4TES $ 30 S5 400 250kcmil 500kcmil K5TGS 90
These special non-aluminum cable lugs are for use with copper cable. Lugs are intended for use with copper cable or where non-aluminum connectors are required (marine, salt or corrosive environments).
Rear cable lug kits (Cu cable only)
Suitable for Max Wire Set of 6 List use with amps range catalog number price
S3 – S4 250 6AWG – 250kcmil K4TER $ 30 S5 400 250kcmil 500kcmil K5TGR 90 S6 600 (2) 2/0 – 350kcmil K6THR 150 S6 800 (3) 250kcmil – 350kcmil K6TJR 170
For use where cable connection from the back-rear of the breaker is desired.
Distribution cable lug kit
Suitable for Max Wire Set of 3 List use with amps range catalog number price
S3 – S4 250 (6) #14 - 6 K4TN $ 125 S5 400 (6) #14 - 1/0 K5TGD 240
1 Suggested lugs for circuit breaker up to amps shown. Cable size and type determine maximum amperes. 2 Includes required lug covers.
15.92 Low Voltage Products & Systems
1SXU 000 023 C0201 ABB Inc. • 888-385-1221 • www.abb-control.com
Discount schedule SA
Loading...
+ 9 hidden pages