Auxiliary elements and accessories for MCBs and RCDs
Selection tables
Combination of auxiliary elements with S200, S200M, S200P, DDA200 + S200 or DS200
4
2CDC092002F0212
HAuxiliary contactS2C-H6R
H-RAuxiliary contactS2C-H6-...R
S/HSignal/Auxiliary contactS2C-S/H6R
S/H (H)Signal/Auxiliary contact used as auxiliary contactS2C-S/H6R
STShunt trip for S 200 MCBS2C-A...
URUndervoltage releaseS2C-UA
OROvervoltage releaseS2C-OVP
H-LAuxiliary contact for S 200 MCBs to be mounted on the lef tS2C-H...L
H-BFAuxiliary contact for MCBs bottom fitting (1 for each pole of MCB) S2C-H01/S2C-H10
BPMechanical tripping deviceS2C-BP
NTSwitched neutralS2C-Nt
In case of using rotary operating mechanism S2C-DH (only right side mountable) the auxiliary devices left side and bottom fitting auxiliary contact could be used.
4/2 2CSC 000 001 D0201| Enclosures and DIN-Rail products
Combination of auxiliary elements with S200M, S200MUC
H, H-RAuxiliary contact H-LAuxiliary contact to be mounted on theleft H-BF Auxiliary contact for bottom fittingS/HSignal/Auxiliary contact S/H(H) Signal/Auxiliary contact used as auxiliarycontactST Shunt trip ST-L Shunt trip to be mounted on theleftURUndervoltage release OR Overvoltage release BP Mechanical tripping deviceS2C-BPNTSwitched neutral S2C-Nt
4
HAuxiliary contactS2C-H6R
H-RAuxiliary contactS2C-H6-...R
S/HSignal/Auxiliary contactS2C-S/H6R
S/H (H)Signal/Auxiliary contact used as auxiliary contactS2C-S/H6R
STShunt trip for S 200 MCBS2C-A...
ST- LShunt trip to be mounted on the left
URUndervoltage releaseS2C-UA
OROvervoltage releaseS2C-OVP
H-LAuxiliary contact for S 200 MCBs to be mounted on the lef tS2C-H...L
H-BFAuxiliary contact for MCBs bottom fitting (1 for each pole of MCB) S2C-H01/S2C-H10
BPMechanical tripping deviceS2C-BP
NTSwitched neutralS2C-Nt
Enclosures and DIN-Rail products | 2CSC 000 001 D0201 4/3
Auxiliary elements for
MCBs S 200, SN 201, RCDs F 200, DS 200 and Switch
Disconnectors SD 200 series
Auxiliary contact and signal/auxiliary contact
S2C-S/H6R, S2C-H6R, S2C-H11L, S2C-H20L and S2C-H02L
Min. operational current/voltage*10 mA at 12 V; 5 mA at 24 V
Rated conditional short-circuit current V230 V AC 1,000 A with S201 K4
Overvoltage categoryIII
Rated impuls withstand voltage
(1.2/50µs)
Cross-section of conductorsmm
Tightening torqueNm1.2 (max. 0.8 for S2C-H11L, S2C-H20L and S2C-H02L)
Contact stability in vibration test
according to IEC/EN 60 068-2-6
Mechanical service life10000 operations
Dimensions (H x D x W)mm85 x 69 x 8.8
kV4
2
0.75…2.5 (up to 2 x 1.5 mm2 for S2C-H11L, S2C-H20L and
S2C-H02L)
5g, 20 sweep cycles 5…150…5 Hz at 24 V AC/DC, 5 mA auto-
matic reclosing < 10 ms
Auxiliary contact and signal/auxiliary contact
S2C-H6-11R, S2C-H6-20R, S2C-H6-02R
Utilization categoryAC14: 1A/400V, 2A/230V
DC12/DC13: 1A/50V, 2A/30V
Conventional free air thermal cur-
rent
Min. rated operational current/
voltage*
Rated conditional short-circuit
current
Overvoltage categoryIII
Rated impuls withstand voltage
(1.2/50µs)
Cross-section of conductorsmm
Tightening torqueNm1.2
Contact stability in vibration test
according to IEC/EN 60068-2-6
Mechanical service life10000 operations
Dimensions (H x D x W)mm85 x 69 x 8.8
* ensures safe contacting without current interruption by pollution layer
A10
10 mA at 12 V; 5 mA at 24 V
V230 V AC 1,000 A with S201 K4
kV4
2
0.75…2.5
5g. 20 sweep cycles 5...150...5 Hz at 24 V AC/DC. 5mA auto-
matic reclosing < 10 ms
4/10 2CSC 000 001 D0201| Enclosures and DIN-Rail products
S2C-S/H6R
S2C-H6-...
2CSC400465F0201
2CSC400324F0201
Signal/auxiliary contacts
Signal contacts indicate if a device tripped due to a failure (overcurrent/short-circuit for MCBs
and RCBOs; earth fault for RCCBs and RCBOs).
Auxiliary contacts indicate the position of the contacts, independent if a failure occurred or the
device was operated manually.
S2C-S/H6R: choice through a selector between signal and auxiliary contact.
S2C-H6R and S2C-HxxR: Auxiliary contacts with contact configuration according the fol-
lowing table.
All right-side mounted contacts are suitable for MCBs, RCDs and switch disconnectors SD200
according the “Selection tables” which are displayed in the beginning of chapter 4.
S2C-HxxL: Auxiliary contacts with contact configuration according the following table. These
contacts are left-side mounted and fit to S200 MCBs and switch disconnertors SD200 according the “Selection tables” which are displayed in the beginning of chapter 4. Especially when
using a motor operating device this is a possibility to add a contact as the right side mounted
ones do not fit within this combination.
S2C-Hxx: Unique bottom-fitting contact for the S200 compact range and SD200 switch disconnectors. Simple and space-saving solution. Also intended for retrofitting.
4
Description
Signal contact/ auxiliary switch 1CO
Auxiliary contact 1CO
Auxiliary co ntact 1NO/1NC
Auxiliary contact 2NO
Auxiliary contact 2NC
Bbn
401677 9
EAN
56 3819S2C-S/H6R2CDS200922R00010.041
563826S2C-H6R2CDS200912R00010.041
697941S2C-H6-11R2CDS200946R00010.041
697958S2C-H6-20R2CDS200946R00020.041
697965S2C-H6-02R2CDS200946R00030.041
Order detailsPrice
Type codeOrder code
Auxiliary contacts mounting on the left side
Description
Auxiliary contact 1 NO/1NC
Auxiliary contact 2 NO
Auxiliary contact 2 NC
Bbn
401677 9
EAN
648820S2C-H11L2CDS200936R00010.041
648837S2C-H20L2CDS200936R00020.041
648844S2C-H02L2CDS200936R00030.041
Order detailsPrice
Type codeOrder code
1 piece
1 piece
Weight
1 piece
kg
Weight
1 piece
kg
Pack
unit
pc.
Pack
unit
pc.
Enclosures and DIN-Rail products | 2CSC 000 001 D0201 4/11
Auxiliary elements for
MCBs S 200, SN 201, RCDs F 200, DS 200 and Switch
Disconnectors SD 200 series
Bottom-fitting auxiliary contact
S2C-H10 and S2C-H01
S2C-H
2CSC400155F0201
4
Conventional free air thermal currentA7. 5
Utilization categoryAC14 2A/230V - DC 12 identical DC13 1A /50V,
Min. operational current/voltage*V10 mA at 12 V AC/DC
Rated conditional short-circuit current230 VAC 1000 A, fault protection with S 201-K2 or Z2
Tightening torqueNm0.5
Cross-section of conductorsmm
Mechanical service life10000 operations
Dimensions (HxDxW)19 x 17 x 17.5
* ensures safe contacting without current interruption by pollution layer
2A/30V
2
0.75 to 2.5
Bottom-fitting auxiliary contacts for S 200, S 200 M, S 200 P, S 200 S, SD 200
Description
1 NC
1 NO
packing unit 15 parts
Description
1 NC
1 NO
Bbn
401677 9
EAN
64551 5 S 2C-H01 2CDS 200 970 R0001 0.011
645 52 2 S 2C-H10 2CDS 200 970 R0002 0.011
Bbn
401677 9
EAN
64677 2 S 2C-H01 15x 2CDS 200 970 R0011 0.0115
646 81 9 S 2C-H10 15x 2CDS 200 970 R0012 0.0115
Order detailsPrice
1 piece
Type codeOrder code
Order detailsPrice
1 piece
Type codeOrder code
Weight
1 piece
kg
Weight
1 piece
kg
Pack
unit
pc.
Pack
unit
pc.
Auxiliary contact bridge for bottom-fitting auxiliary contacts
Wire jumper for integrated auxiliary contact S2C-H01/S2C-H10 for series connections (HKB) or
parallel connections (HKB1).
Description
1/2 mod.
1 mod.
Bbn
80125 42
EAN
523134HKBGH V036 0504 R01000.0011000
524209HK B 1 GH V036 0504 R01010.0011000
Order detailsPrice
1 piece
Type codeOrder code
Weight
1 piece
kg
Pack
unit
pc.
Signal and auxiliary contacts
Terminalsmm
Tightening torqueN1.2
DimensionsmmH: 85 x D: 68 x W: 8.9H: 85 x D: 68,7 x W: 8.9
Rated voltageV230
Rated currentA2
4/12 2CSC 000 001 D0201| Enclosures and DIN-Rail products
SN201- SSN201-IH
2
2x 1,5
SN201- S
2CSC400682F00012CSC400681F0001
Utilization category / contact capacity
SN201-S, SN201-IH
AC14UeV400230
IeA12
DC12UeV220110
IeA11,5
DC13UeV6024
IeA24
SN201-IH
Signal contact for SN201 MCBs
Function: indication of the device contact positions only after the automatic release of the
MCBs due to overcurrent.
Description
Signal contact 1CO
Bbn
80125 42
EAN
104957SN201-S2CSS200924R00010.0401
Order detailsPrice
1 piece
Type codeOrder code
Weight
1 piece
kg
Pack
unit
pc.
Auxiliary contact / interface module for SN201 MCBs
Function: indication of the device contact positions. The auxiliary contact can be used as an
interface module between SN201 and other compact auxiliary elements.
Description
Interface module/Aux. Contact 1CO
Signal and auxiliary contacts for F 200 125A and F 200 B
Rated currentACA6
Min. rated voltage Ub minACV230
Connection cross sectionmm
Tightening torqueNm0.8
Dimensions (H x D x W)mm85 x 69 x 8.8
Bbn
80125 42
EAN
104858S N201- IH2CSS200923R00010.0501
DCA1
DCV110
Order detailsPrice
Type codeOrder code
F2 125A- S/H
2
1...1.5
1 piece
Weight
1 piece
kg
Pack
unit
pc.
4
Auxiliary/Signal contact for F 200 125A and F 200 B
Function: choice through a selector between indication of the position of the device’s contacts
and signalling of the earth fault. Suitable for RCCBs F 200 125A and F 200 B series
Description
Auxiliary/Signal contact 1CO+1NC
Bbn
80125 42
EAN
600527F2-125A-B-S/H2CSF200922R00010.041
Order detailsPrice
1 piece
Type codeOrder code
Weight
1 piece
kg
Pack
unit
pc.
Clamping cover for F200 125A-F200 B type
Description
Bbn
401677 9
EAN
999638CPV B2CSF200988R00011
Order detailsPrice
1 piece
Type codeOrder code
Enclosures and DIN-Rail products | 2CSC 000 001 D0201 4/13
Weight
1 piece
kg
Pack
unit
pc.
Auxiliary elements for
MCBs S 200, SN 201, RCDs F 200, DS 200 and Switch
Disconnectors SD 200 series
Function: remote opening of the device when a voltage is applied. Suitable for MCBs S 200
series, RCBOs DS 200 series, SD 200 switch disconnectors series.
Shunt trips use a coil like MCBs for tripping. To trip a shunt it is necessary to choose the right
voltage and make sure the corresponding Ibmax (as mentioned in the table above) is provided
by the power supply used. If the power supply can provide higher currents the shunt trip will
reduce the current to Ibmax due to its internal resistance.
As soon as the shunt tripped, the contact inside is open – the electrical circuit is disconnected
even if the shunt trip is still powered on. The free-tripping mechanism of the shunt trip allows a
restart of the MCB only after the shunt trip gets no external release signal anymore.
Rated voltage
AC/DC 12…60 V
AC 110…415 V/DC110…250 V
Bbn
401677 9
EAN
570992S2C-A12CDS200909R00010.151
5710 05S2C-A22CDS200909R00020.151
Order detailsPrice
1 piece
Type codeOrder code
Weight
1 piece
kg
Pack
unit
pc.
4/14 2CSC 000 001 D0201| Enclosures and DIN-Rail products