ABB MCBs, RCDs Accessories Catalog

Auxiliary elements and accessories for MCBs and RCDs
Selection tables
Combination of auxiliary elements with S200, S200M, S200P, DDA200 + S200 or DS200
4
2CDC092002F0212
H Auxiliary contact S2C-H6R
H-R Auxiliary contact S2C-H6-...R
S/H Signal/Auxiliary contact S2C-S/H6R
S/H (H) Signal/Auxiliary contact used as auxiliary contact S2C-S/H6R
UR Undervoltage release S2C-UA
OR Overvoltage release S2C-OVP
H-L Auxiliary contact for S 200 MCBs to be mounted on the lef t S2C-H...L
H-BF Auxiliary contact for MCBs bottom fitting (1 for each pole of MCB) S2C-H01/S2C-H10
BP Mechanical tripping device S2C-BP
NT Switched neutral S2C-Nt
In case of using rotary operating mechanism S2C-DH (only right side mountable) the auxiliary devices left side and bottom fitting auxiliary contact could be used.
4/2 2CSC 000 001 D0201 | Enclosures and DIN-Rail products
Combination of auxiliary elements with S200M, S200MUC
H, H-R Auxiliary contact H-L Auxiliary contact to be mounted on the left H-BF Auxiliary contact for bottom tting S/H Signal/Auxiliary contact S/H (H) Signal/Auxiliary contact used as auxiliary contact ST Shunt trip ST-L Shunt trip to be mounted on the left UR Undervoltage release OR Overvoltage release BP Mechanical tripping device S2C-BP NT Switched neutral S2C-Nt
4
H Auxiliary contact S2C-H6R
H-R Auxiliary contact S2C-H6-...R
S/H Signal/Auxiliary contact S2C-S/H6R
S/H (H) Signal/Auxiliary contact used as auxiliary contact S2C-S/H6R
ST- L Shunt trip to be mounted on the left
UR Undervoltage release S2C-UA
OR Overvoltage release S2C-OVP
H-L Auxiliary contact for S 200 MCBs to be mounted on the lef t S2C-H...L
H-BF Auxiliary contact for MCBs bottom fitting (1 for each pole of MCB) S2C-H01/S2C-H10
BP Mechanical tripping device S2C-BP
NT Switched neutral S2C-Nt
Enclosures and DIN-Rail products | 2CSC 000 001 D0201 4/3
Auxiliary elements for
MCBs S 200, SN 201, RCDs F 200, DS 200 and Switch Disconnectors SD 200 series
Auxiliary contact and signal/auxiliary contact
S2C-S/H6R, S2C-H6R, S2C-H11L, S2C-H20L and S2C-H02L
Utilization category AC14 1A/400V, 2A/230V - DC12 1A/220V, 1,5A/110V -
DC13 2A/60V, 4A/24V
2CSC400465F0201
Auxiliary elements
4
Conventional free air thermal current A 10
Min. operational current/voltage* 10 mA at 12 V; 5 mA at 24 V
Rated conditional short-circuit current V 230 V AC 1,000 A with S201 K4
Overvoltage category III
Rated impuls withstand voltage
(1.2/50µs)
Cross-section of conductors mm
Tightening torque Nm 1.2 (max. 0.8 for S2C-H11L, S2C-H20L and S2C-H02L)
Contact stability in vibration test
according to IEC/EN 60 068-2-6
Mechanical service life 10000 operations
Dimensions (H x D x W) mm 85 x 69 x 8.8
kV 4
2
0.75…2.5 (up to 2 x 1.5 mm2 for S2C-H11L, S2C-H20L and
S2C-H02L)
5g, 20 sweep cycles 5…150…5 Hz at 24 V AC/DC, 5 mA auto-
matic reclosing < 10 ms
Auxiliary contact and signal/auxiliary contact
S2C-H6-11R, S2C-H6-20R, S2C-H6-02R
Utilization category AC14: 1A/400V, 2A/230V
DC12/DC13: 1A/50V, 2A/30V
Conventional free air thermal cur-
rent
Min. rated operational current/
voltage*
Rated conditional short-circuit
current
Overvoltage category III
Rated impuls withstand voltage
(1.2/50µs)
Cross-section of conductors mm
Tightening torque Nm 1.2
Contact stability in vibration test
according to IEC/EN 60068-2-6
Mechanical service life 10000 operations
Dimensions (H x D x W) mm 85 x 69 x 8.8
* ensures safe contacting without current interruption by pollution layer
A 10
10 mA at 12 V; 5 mA at 24 V
V 230 V AC 1,000 A with S201 K4
kV 4
2
0.75…2.5
5g. 20 sweep cycles 5...150...5 Hz at 24 V AC/DC. 5mA auto-
matic reclosing < 10 ms
4/10 2CSC 000 001 D0201 | Enclosures and DIN-Rail products
S2C-S/H6R
S2C-H6-...
2CSC400465F0201
2CSC400324F0201
Signal/auxiliary contacts
Signal contacts indicate if a device tripped due to a failure (overcurrent/short-circuit for MCBs and RCBOs; earth fault for RCCBs and RCBOs). Auxiliary contacts indicate the position of the contacts, independent if a failure occurred or the device was operated manually.
S2C-S/H6R: choice through a selector between signal and auxiliary contact.
S2C-H6R and S2C-HxxR: Auxiliary contacts with contact configuration according the fol-
lowing table. All right-side mounted contacts are suitable for MCBs, RCDs and switch disconnectors SD200 according the “Selection tables” which are displayed in the beginning of chapter 4.
S2C-HxxL: Auxiliary contacts with contact configuration according the following table. These contacts are left-side mounted and fit to S200 MCBs and switch disconnertors SD200 accor­ding the “Selection tables” which are displayed in the beginning of chapter 4. Especially when using a motor operating device this is a possibility to add a contact as the right side mounted ones do not fit within this combination.
S2C-Hxx: Unique bottom-fitting contact for the S200 compact range and SD200 switch dis­connectors. Simple and space-saving solution. Also intended for retrofitting.
4
Description
Signal contact/ auxiliary switch 1CO
Auxiliary contact 1CO
Auxiliary co ntact 1NO/1NC
Auxiliary contact 2NO
Auxiliary contact 2NC
Bbn 401677 9
EAN
56 3819 S2C-S/H6R 2CDS200922R0001 0.04 1
563826 S2C-H6R 2CDS200912R0001 0.04 1
697941 S2C-H6-11R 2CDS200946R0001 0.04 1
697958 S2C-H6-20R 2CDS200946R0002 0.04 1
697965 S2C-H6-02R 2CDS200946R0003 0.04 1
Order details Price
Type code Order code
Auxiliary contacts mounting on the left side
Description
Auxiliary contact 1 NO/1NC
Auxiliary contact 2 NO
Auxiliary contact 2 NC
Bbn 401677 9
EAN
648820 S2C-H11L 2CDS200936R0001 0.04 1
648837 S2C-H20L 2CDS200936R0002 0.04 1
648844 S2C-H02L 2CDS200936R0003 0.04 1
Order details Price
Type code Order code
1 piece
1 piece
Weight 1 piece
kg
Weight 1 piece
kg
Pack unit
pc.
Pack unit
pc.
Enclosures and DIN-Rail products | 2CSC 000 001 D0201 4/11
Auxiliary elements for
MCBs S 200, SN 201, RCDs F 200, DS 200 and Switch Disconnectors SD 200 series
Bottom-fitting auxiliary contact
S2C-H10 and S2C-H01
S2C-H
2CSC400155F0201
4
Conventional free air thermal current A 7. 5
Utilization category AC14 2A/230V - DC 12 identical DC13 1A /50V,
Min. operational current/voltage* V 10 mA at 12 V AC/DC
Rated conditional short-circuit current 230 VAC 1000 A, fault protection with S 201-K2 or Z2
Tightening torque Nm 0.5
Cross-section of conductors mm
Mechanical service life 10000 operations
Dimensions (HxDxW) 19 x 17 x 17.5
* ensures safe contacting without current interruption by pollution layer
2A/30V
2
0.75 to 2.5
Bottom-fitting auxiliary contacts for S 200, S 200 M, S 200 P, S 200 S, SD 200
Description
1 NC
1 NO
packing unit 15 parts
Description
1 NC
1 NO
Bbn 401677 9
EAN
64551 5 S 2C-H01 2CDS 200 970 R0001 0.01 1
645 52 2 S 2C-H10 2CDS 200 970 R0002 0.01 1
Bbn 401677 9
EAN
64677 2 S 2C-H01 15x 2CDS 200 970 R0011 0.01 15
646 81 9 S 2C-H10 15x 2CDS 200 970 R0012 0.01 15
Order details Price
1 piece
Type code Order code
Order details Price
1 piece
Type code Order code
Weight 1 piece
kg
Weight 1 piece
kg
Pack unit
pc.
Pack unit
pc.
Auxiliary contact bridge for bottom-fitting auxiliary contacts
Wire jumper for integrated auxiliary contact S2C-H01/S2C-H10 for series connections (HKB) or parallel connections (HKB1).
Description
1/2 mod.
1 mod.
Bbn 80125 42
EAN
523134 HKB GH V036 0504 R0100 0.001 1000
524209 HK B 1 GH V036 0504 R0101 0.001 1000
Order details Price
1 piece
Type code Order code
Weight 1 piece
kg
Pack unit
pc.
Signal and auxiliary contacts
Terminals mm
Tightening torque N 1.2
Dimensions mm H: 85 x D: 68 x W: 8.9 H: 85 x D: 68,7 x W: 8.9
Rated voltage V 230
Rated current A 2
4/12 2CSC 000 001 D0201 | Enclosures and DIN-Rail products
SN201- S SN201-IH
2
2x 1,5
SN201- S
2CSC400682F00012CSC400681F0001
Utilization category / contact capacity
SN201-S, SN201-IH
AC14 Ue V 400 230
Ie A 1 2
DC12 Ue V 220 110
Ie A 1 1,5
DC13 Ue V 60 24
Ie A 2 4
SN201-IH
Signal contact for SN201 MCBs
Function: indication of the device contact positions only after the automatic release of the MCBs due to overcurrent.
Description
Signal contact 1CO
Bbn 80125 42
EAN
104957 SN201-S 2CSS200924R0001 0.040 1
Order details Price
1 piece
Type code Order code
Weight 1 piece
kg
Pack unit
pc.
Auxiliary contact / interface module for SN201 MCBs
Function: indication of the device contact positions. The auxiliary contact can be used as an interface module between SN201 and other compact auxiliary elements.
Description
Interface module/Aux. Contact 1CO
Signal and auxiliary contacts for F 200 125A and F 200 B
Rated current AC A 6
Min. rated voltage Ub min AC V 230
Connection cross section mm
Tightening torque Nm 0.8
Dimensions (H x D x W) mm 85 x 69 x 8.8
Bbn 80125 42
EAN
104858 S N201- IH 2CSS200923R0001 0.050 1
DC A 1
DC V 110
Order details Price
Type code Order code
F2 125A- S/H
2
1...1.5
1 piece
Weight 1 piece
kg
Pack unit
pc.
4
Auxiliary/Signal contact for F 200 125A and F 200 B
Function: choice through a selector between indication of the position of the device’s contacts and signalling of the earth fault. Suitable for RCCBs F 200 125A and F 200 B series
Description
Auxiliary/Signal contact 1CO+1NC
Bbn 80125 42
EAN
600527 F2-125A-B-S/H 2CSF200922R0001 0.04 1
Order details Price
1 piece
Type code Order code
Weight 1 piece
kg
Pack unit
pc.
Clamping cover for F200 125A-F200 B type
Description
Bbn 401677 9
EAN
999638 CPV B 2CSF200988R0001 1
Order details Price
1 piece
Type code Order code
Enclosures and DIN-Rail products | 2CSC 000 001 D0201 4/13
Weight 1 piece
kg
Pack unit
pc.
Auxiliary elements for
MCBs S 200, SN 201, RCDs F 200, DS 200 and Switch Disconnectors SD 200 series
Shunt trip for S 200 MCBs
S2C- A1
Rated voltage AC V 12…6 0
DC V 12…60
2CSC400471F0201
S2C-A
4
Max release duration ms <10
Min. release voltage AC V 7
DC V 10
Power consumption Ub V 12
DC
Ib max A 2.2 2.5 4.5 5 14 8.8
Coil resistance 3.7
Terminals Fale-safe bi-directional cylinder-lift-terminal
Tightening torque Nm 2.8
Dimensions (H x D x W) mm 85 x 69 x 17.5
S2C-A2
Rated voltage AC V 110 …415
DC V 110… 2 5 0
Max release duration ms <10
Min. release voltage AC V 55
DC V 80
Power consumption Ub V 110
DC
Ib max A 0.4 0.5 1.1 1.0 2.7
Coil resistance 225
Terminals Fale-safe bi-directional cylinder-lift-terminal
Tightening torque Nm 2.8
Dimensions (H x D x W) mm 85 x 69 x 17.5
12
AC
110
AC
24
DC
220
DC
24
AC
230
AC
60
DC
415
AC
60
AC
Shunt trips
Function: remote opening of the device when a voltage is applied. Suitable for MCBs S 200 series, RCBOs DS 200 series, SD 200 switch disconnectors series. Shunt trips use a coil like MCBs for tripping. To trip a shunt it is necessary to choose the right voltage and make sure the corresponding Ibmax (as mentioned in the table above) is provided by the power supply used. If the power supply can provide higher currents the shunt trip will reduce the current to Ibmax due to its internal resistance. As soon as the shunt tripped, the contact inside is open – the electrical circuit is disconnected even if the shunt trip is still powered on. The free-tripping mechanism of the shunt trip allows a restart of the MCB only after the shunt trip gets no external release signal anymore.
Rated voltage
AC/DC 12…60 V
AC 110…415 V/DC110…250 V
Bbn 401677 9
EAN
570992 S2C-A1 2CDS200909R0001 0.15 1
5710 05 S2C-A2 2CDS200909R0002 0.15 1
Order details Price
1 piece
Type code Order code
Weight 1 piece
kg
Pack unit
pc.
4/14 2CSC 000 001 D0201 | Enclosures and DIN-Rail products
Loading...