Railway
1
application
conactors
TBC7-30 TAL26..RT TAE50…TAE75..RT AF210B…AF300B
Electrical ratings
AC general
purpose ratings
(A)
600V
Maximum
motor switching
current (A)
200…
208V
16 9.6 2 3 5 5
21 9 2 2 5 7.5
25 11 3 3 7.5 10
30 17 5 5 10 15
40 28 7.5 10 20 25
50 34 10 10 25 30
60 42 10 15 30 40
80 54 15 20 40 50 1 1 TAE50-30-11-Δ TAE50-30-11RT-Δ
105 80 25 30 60 75 1 1 TAE75-30-11-Δ TAE75-30-11RT-Δ
150 88 30 30 60 75 1 1 AF95B-30-11-Δ AF95B-30-11RT-Δ
150 104 30 40 75 100 1 1 AF110B-30-11-Δ AF110B-30-11RT-Δ
230 130 40 50 100 125 1 1 AF145B-30-11-Δ AF145B-30-11RT-Δ
250 156 50 60 125 150 1 1 AF185B-30-11-Δ AF185B-30-11RT-Δ
300 192 60 75 150 200 1 1 AF210B-30-11-Δ AF210B-30-11RT-Δ
350 248 75 100 200 250 1 1 AF260B-30-11-Δ AF260B-30-11RT-Δ
400 302 100 100 250 300 1 1 AF300B-30-11-Δ AF300B-30-11RT-Δ
Note: devices with ring-tongue termination UL recognized
Coil voltage selection chart (Δ)
Rated control circuit
voltage U
c
TBC7
17…32V DC 51 51 51 24…45V DC 52 52 52 20…60V DC - - - 72
36…65V DC 54 54 54 42…78V DC 58 58 58 50…90V DC 55 55 55 48…130V AC/DC - - - 69
77..143V DC 62 62 62 90…150V DC 66 66 66 100…250V AC/DC - - - 70
152…264V DC 68 68 68 Example:
24V DC input voltage: TAL9-30-10-52
120V AC input voltage: AF300B-30-11RT-70
TAL9…
AC motor ratings, breaking all lines,
three phase, 50/60 Hz (hp)
220…
240V
TAL40
TAE50…
TAE75
440…
480V
AF95B…
AF300B
550…
600V
Standard auxiliary
contacts
NO NC
Catalog
number,
Standard
termination
1 - TBC7-30-10-Δ -
- 1 TBC7-30-01-Δ 1 - TAL9-30-10-Δ TAL9-30-10RT-Δ
- 1 TAL9-30-01-Δ TAL9-30-01RT-Δ
1 - TAL12-30-10-Δ TAL12-30-10RT-Δ
- 1 TAL12-30-01-Δ TAL12-30-01RT-Δ
1 - TAL16-30-10-Δ TAL16-30-10RT-Δ
- 1 TAL16-30-01-Δ TAL16-30-01RT-Δ
1 - TAL26-30-10-Δ TAL26-30-10RT-Δ
- 1 TAL26-30-01-Δ TAL26-30-01RT-Δ
1 - TAL30-30-10-Δ TAL30-30-10RT-Δ
- 1 TAL30-30-01-Δ TAL30-30-01RT-Δ
1 - TAL40-30-10-Δ TAL40-30-10RT-Δ
1 TAL40-30-01-Δ TAL40-30-01RT-Δ
Coil operating limits
For traction-specic catalog numbers starting with “T”, the coil operating limits are included in the coil voltage range (Uc min…Uc max.). For AF..B devices, the coil range
is nominal with operating limits 15% below and 10% above the range specied.
Catalog
number,
Ring-tongue
termination
1.204 Low Voltage Products & Systems
1SXU000023C0202 Rev. A