PSR — The compact range PSE — The efficient range PST(B) — The advanced range
PSR3 ... PSR16 PSR25 ... PSR30 PSR37 ... PSR45 PSR60 ... PSR105 PSE18 ... PSE105
Normal start
In-Line connected
(400 V) kW
IEC, Max. A
(440-480 V) hp
UL, Max. A
Using manual motor
starter or MCCB, type
1 coordination will be
achieved.
PSR3 PSR6 PSR9 PSR12 PSR16 PSR25 PSR30 PSR37 PSR45 PSR60 PSR72 PSR85 PSR105
1.5 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55
3.9 6.8 9 12 16 25 30 37 45 60 72 85 105
2 3 5 7.5 10 15 20 25 30 40 50 60 75
3.4 6.1 9 11 15.2 24.2 28 34 46.2 59.4 68 80 104
400 V, 40 ºC 400 V, 40 ºC 400 V, 40 ºC
Manual motor starters (50 kA) MCCB (50 kA) MCCB (50 kA)
MS116 MS132 MS450 MS495 – T2S160 T3S250 T4S320 T5S400 T5S630 T2S160 T3S250 T4S250 T5S400 T5S630 T6S630 T6S800 T7S1250 T7S1600
Using gG fuses, type
1 coordination will be
achieved. To achieve
type 2 coordination,
semiconductor fuses
must be used.
Suitable switch fuse for
the recommended gG
fuses or semiconductor
fuses.
The line contactor is
not required for the
softstarter itself but
often used to open if
OL trips
Overload protection
is always required to
protect the motor
Using by-pass will
reduce the power
loss and allow more
starts per hour
Fuse protection (50 kA) gG Fuse Fuse protection (85 kA), Semiconductor fuses, Bussmann Fuse protection (65 kA), Semiconductor fuses, Bussmann
10 A 16 A 25 A 32 A 50 A 63 A 100 A 125 A 200 A 250 A
Switch fuse Switch fuse Switch fuse
OS32GD OS125GD OS250GD OS32GD03P OS63GD03P OS125GD03P
Line contactor Line Contactor Line contactor
AF9 AF12 AF16 AF26 AF30 AF38 A50 A63 A75 A95 A110 AF26 AF30 AF38 A50 A63 A75 A95 A110 A145 A185 A210 A260 A300 AF400 AF30 AF38 A50 A63 A75 A95 A110 A145 A185 A210 A260 A300 AF400 AF580 AF750 AF1350 AF1650
Thermal overload relay Electronic overload relay Electronic overload relay
By-pass By-pass By-pass
Quick guide for selection
Normal start Class 10 Heavy duty start class 30
• Bow thruster • Centrifugal fan
• Centrifugal pump • Crusher
• Compressor • Conveyor belt (long)
• Conveyor belt (short) • Mill
• Elevator • Mixer
• Escalator • Stirrer
Select size according to the motor
kW ratings
Select one size larger than the standard selection
!
Select one size larger softstarter compared
to the motor kW ratings
If more than 10 starts/h
TF42DU TA75DU TA110DU Built-in Built-in
Built-in Built-in AF16 AF26 AF30 A40 A50 A63 A95 A145 A210 Built-in
PSR
LED indications:
• On/Ready
• Run/Top of ramp
Three potentiometers for settings:
-Start ramp (1–20 sec)
-Stop ramp (0–20 sec)
-Initial voltage (40–70 % of U
(also set “end voltage”)
Built-in signal relays for
Run (PSR3 ... 105) and
TOR (PSR25 ... 105)
)
e