ABB Primary switch mode power supplies CP-D range Catalog Page

4
NEW
available in
March 2008
Output voltages 12 V, 24 V
Adjustable output voltages (devices > 10 W)
Output currents 0.42 A / 0.83 A / 1.3 A / 2.1 A / 2.5 A / 4.2 A
Power range 10 W, 30 W, 60 W, 100 W
Wide range input 100-240 V AC (90-264 V AC, 120-370 V DC)
High effi ciency of up to 89 %
Low power dissipation and low heating
Free convection cooling (no forced cooling with ventilators)
Ambient temperature range during operation -10...+70 °C
Open-circuit, overload and short-circuit stable
Integrated input fuse
U/I characteristic (fold-forward behaviour at overload –
no switch-off)
LEDs for status indication
Light-grey enclosure in RAL 7035
Approvals / Marks
(depending on device, partly pending):
CP-D range
Primary switch mode power supplies
Width and structural form
With their width between 18 to 90 mm only switch mode power supplies ar ideally suited for installation in distribution panels.
Wide range input
Optimised for world-wide applications: The CP-D power supplies can be supplied with 90-264 V AC or 120-370 V DC.
2CDC 275 031 F0b07
Adjustable output voltage
The CP-D range types > 10 W featur output voltage. Thus, they can be optimally adapted to the application, e.g. compensating the voltage dr long line length.
, the CP-D range
e a continuously adjustable
e
2CDC 271 027 F00072CDC 276 032 F0007-a
2CDC 276 033 F0007
op caused by a
A, H, D, E / a, b
170 Low Voltage Products & Systems
1SXU 110 079 C0201 ABB Inc. • 888-385-1221 U.S. • 866-222-8368 Mid-West & Pacifi c Region • 866-460-3300 Ontario • 800-567-0283 Atlantic & Quebec Region • www.abb-control.com/epr8.pdf
NEW
available in
March 2008
Primary switch mode power supplies CP-D range
Ordering details
2CDC 271 024 F0b07
CP-D 12/0.83, CP-D 24/0.42
2CDC 271 025 F0b07
CP-D 12/2.1 CP-D 24/1.3
Type
CP-D 12/0.83
CP-D 12/2.1
CP-D 24/0.42
CP-D 24/1.3
CP-D 24/2.5
CP-D 24/4.2
Rated input
voltage
100-240 V AC
100-240 V AC
100-240 V AC
100-240 V AC
100-240 V AC
100-240 V AC
Rated output
voltage /
current
12 V DC /
0.83 A
12 V DC /
2.1 A
24 V DC /
0.42 A
24 V DC /
1.3 A
24 V DC /
2.5 A
24 V DC /
4.2 A
Order code
1SVR 427 041 R1000
1SVR 427 043 R1200
1SVR 427 041 R0000
1SVR 427 043 R0100
1SVR 427 044 R0200
1SVR 427 045 R0400
Pack.
pieces
Price
unit
1 piece
1 0.06 / 0.13
1 0.19 / 0.41
1 0.06 / 0.13
1 0.19 / 0.41
1 0.25 / 0.55
1 0.32 / 0.71
Weight
1 piece
kg / lb
4
2CDC 271 028 F0b07
CP-D 24/2.5
2CDC 271 029 F0b07
CP-D 24/4.2
Low Voltage Products & Systems 171
ABB Inc. • 888-385-1221 U.S. • 866-222-8368 Mid-West & Pacifi c Region • 866-460-3300 Ontario • 800-567-0283 Atlantic & Quebec Region • www.abb-control.com/epr8.pdf 1SXU 110 079 C0201
• Approvals ......................................168 • Technical data ...............................172 • Technical diagrams ...........................176
• Dimensional drawings ...................176
4
NEW
available in
March 2008
Data at Ta = 25 °C, UIN = 230 V AC and rated values, if nothing else indicated
Typ e CP-D 12/0.83 CP-D 12/2.1
Input circuit - supply circuit L, N
Rated input voltage U Input voltage range 90-264 V AC /
Frequency range AC 47-63 Hz Typical input current /
typical power consumption
Inrush current at 230 V AC 30 A (max. 3 ms) 50 A (max. 3 ms) Power failure buffering > 30 ms Internal input fuse 1 A slow-acting /
Indication of operational states
Output voltage DC ON: green LED
Output circuit +, - ++, --
Rated output voltage 12 V DC Tolerance of the output voltage ±1 % Adjustment range of the output voltage - 12-14 V DC Rated output power 10 W 30 W Rated output current I Derating of the output current 60 °C < T Deviation with load change statical max. 1 %
Control time < 1 ms Starting time after applying the supply voltage at I Response time at rated load typ. 1 ms Residual ripple and switching peaks BW = 20 MHz 50 mV Parallel connection no Series connection yes, to increase voltage Resistance to reverse feed 18 V / 1 s Power factor correction (PFC) no
Output circuit - No-load, overload and short-circuit behaviour
Output curve U/I curve Short-circuit protection continuous short-circuit statility Short-circuit behaviour continuation with current limitation Current limitation at short circuit typ. 1.4 A typ. 5.9 A Overload protection current limitation No-load protection continuous no-load stability Starting of capacitive loads unlimited
Gerneral data
Effi ciency typ. 78 % typ. 82 % Duty time 100 % Dimensions (WxHxD) 18 x 91 x 57.5 mm
Weight 0.06 kg (0.13 lb) 0.19 kg (0.41 lb) Material of enclosure plastic Mounting DIN rail (EN 60715), snap-on mounting without any tool Mounting position horizontal Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in) Degree of protection enclosure / terminals IP20 / IP20 Protection class II
IN
r
change of input voltage within the input voltage range max. 1 %
CP-D range
Technical data
DC LOW: red LED
dynamical 10-90%
100-240 V AC
120-370 V DC
at 110 V AC 200 mA / 12.68 W 502 mA / 31.14 W at 230 V AC 128.3 mA / 13.01 W 277 mA / 31.2 W
250 V AC
2 A slow-acting /
250 V AC
V: output voltage applied V: output voltage too low
Ta 60 °C 0.83 A 2.1 A
70 °C 2.5 %/K
a
r
[0.71 x 3.58 x 2.26 in]
1000 ms
53 x 91 x 57.5 mm
[2.09 x 3.58 x 2.26 in]
Primary switch mode power supplies
172 Low Voltage Products & Systems
1SXU 110 079 C0201 ABB Inc. • 888-385-1221 U.S. • 866-222-8368 Mid-West & Pacifi c Region • 866-460-3300 Ontario • 800-567-0283 Atlantic & Quebec Region • www.abb-control.com/epr8.pdf
Loading...
+ 4 hidden pages