Accessories
for Overload relays
Separate mounting kits
For O/L
relays number
TA25DU 0.1 – 25 DB25/25A
TA42DU, TA75DU, TA80DU 18 – 80 DB80
TA25DU 24 – 32 DB25/32A
TA110DU 100 – 200 DB200
Amps
Accessories
Catalog
DB25/25A
DB80
DB200
Flat pin terminal blocks
Mounting on: number
TA25DU relay LC30-T
DB25/25A or DB25/32A LC26-B1
Catalog
Terminal block— AWG #8 cable
Mounting on: number
TA25DU (25A or less) or DB25/25A DX25
Catalog
Description
LC terminal blocks can be used to convert standard connections into Faston connections: 2 x 6.3 mm or 4 x 2.8 mm per
pole. The connections are protected against accidental contact.
The LC30-T has a terminal block for the 3 power terminals and a second for the 4 auxiliary terminals of a TA25 DU
thermal O/L relay.
The LC26-B1 has two identical terminal blocks each for 3 power terminals. This block allows the power terminals to be
mounted with two DB25 kits or a TA25DU thermal O/L relay and DB25 kit assembly.
NOTE: According to DIN 46429 part 1 and NFC 20-120 the max. capacity of a Faston connection is 25 A.
LC26-B1
OVERLOAD RELAYS: General info: 3.1 – 3.2 Selection: 3.3 – 3.4 Accessories: 3.5 – 3.6 Technical data: 3.7 – 3.10 Dimensions: 3.11 – 3.12
AC 1030 – 6/98
ABB Control Inc. 3.5
Discount schedule TAA — TA25
Overload relays
Accessories
DS25A
Accessories
for Overload relays
Remote tripping coils
U voltage at 50/60 Hz Catalog
DS25-A remote tripping coil
DS25-A remote resetting coil
24V DS25-A-24
48V DS25-A-48
110V DS25-A-110
220/380V DS25-A-220/380
500V DS25-A-500
24V DR25-A-24
48V DR25-A-48
110V DR25-A-110
220/380V DR25-A-220/380
500V DR25-A-500
Application
• The DS25-A coil is used for remote electrical tripping of the TA25 DU thermal O/L relay and is connected to the relay's
normally closed 95-96 auxiliary contact.
• The DR 25-A coil is used for remote electrical resetting of the TA25DU thermal O/L relay which is
adjusted for "Manual resetting"; it is connected to the relay's normally open 97-98 auxiliary contact.
The coils are not designed for continuous duty. Impulse duration: 0.2 to 0.35 s.
Set the button to "Man" (Manual resetting).
Mounting: clipped on to TA25DU thermal O/L relay.
number
DR25A
Installation diagrams
For connection of DS25-A to TA25DU relay For connection of DR25-A to TA25DU relay
L1 L2/N
Overload relays
STOP
21 22
START
13 14
M
A1 A2
95
M
13 14
OVERLOAD
TRIP
E1 E2
TRIPPING
COIL
HAND
OFF
23 24
13 14
AUTO
M
A1 A2
95
L1 L2/N
O L
OL
O L
L1 L2/N
STOP
96
21 22
START
13 14
M
A1 A2
O L
95
96
M
13 14
OVERLOAD
RESET
HAND
OFF
AUTO
23 24
13 14
L1 L2/N
96
O L
97
98
M
A1 A2
E1 E2
OL
RESETTING
COIL
O L
96
95
OVERLOAD
TRIP
E1 E2
OL
TRIPPING
COIL
OVERLOAD RELAYS: General info: 3.1 – 3.2 Selection: 3.3 – 3.4 Accessories: 3.5 – 3.6 Technical data: 3.7 – 3.10 Dimensions: 3.11 – 3.12
3.6 ABB Control Inc.
Discount schedule TAA — TA25
OVERLOAD
RESET
O L
97
E1 E2
98
RESETTING
OL
COIL
AC 1030 – 6/98