Standard
CAM SWITCHES RANGE
CAM SWITCHES RANGE
Black handle and silver front plate with
standard text are included.
t
OM
Cam switch size OM ON OL40 OL63 OL80N OL125 OL160 OL200 ON_M
Ith / IEC 60947 [A] 10 25 45 63 80 150 175 315 25
UL 508 [A] 10 25 40 - - 125 160 200 25
Positions
t
ON
ON-OFF switches
Rotating angle 90, 0-position: 9 o’clock
Black handle 1 - 0
Key operated 1 - 0 1, 2 and 3- pole - - -
Rotating angle 90, 0-position: 12 o’clock
Black handle 1 - 0
Key operated 1 - 0 1, 2 and 3- pole - - -
Change-over switches
Rotating angle 60 - 0 - 60, with 0-position
Black handle 1 - 0 - 2
Key operated 1 - 0 - 2 1 and 3- pole - - -
Key operated, with two sided spring return 1R - 0 - 2
Rotating angle 60 - 60, without 0-position 1 - 2 1, 2, 3 and 4- pole 1, 2, 3 and 4- pole 1, 2, 3 and 4- pole
With overlapping contacts 1 - 2 1, 2, 3 and 4- pole 1, 2, 3 and 4- pole - -
With common center position and with
overlapping contacts
1 - 1+ 2 - 2 - 3 and 4- pole 3 and 4- pole -
R
Bypass switches
Without overlapping, for 3 and 4-pole net 1 - 0 - Bypass - 3 / 6- pole, 4 / 8- pole 3 / 6- pole, 4 / 8- pole -
With overlapping, for 3 and 4-pole net 1 - Bypass - 3 / 6- pole, 4 / 8- pole 3 / 6- pole, 4 / 8- pole -
Multistep switches
With 0-position
2 - step switches 0-1-2
3- step switches 0-1-2-3 1, 2, 3 and 4- pole 1- pole 1-pole 1- pole
4- step switches 0-1-2-3-4 1, 2 and 3- pole - - -
5- step switches 0-1-2-3-4-5 1 and 2- pole - - -
6- step switches 0-1-2-3-4-5-6 - 1, 2 and 3- pole - -
7, 8, 9, 10 and 11- step switches 0-1-2-3-4-5-6-7-8...-11 - 1- pole - -
Without 0-position
3- step switches 1-2-3
4- step switches 1-2-3-4 1, 2 and 3- pole - - -
5- step switches 1-2-3-4-5 1 and 2- pole - - -
6- step switches 1-2-3-4-5-6 - 1, 2 and 3- pole - -
7, 8, 9, 10, 11 and 12- step switches 1-2-3-4-5-6-7-8...-12 - 1- pole - -
Motor control switches
Ventilation switches A - 0 - 1/2 - 1/1 2- pole - 1- pole
Reversing switches 1 - 0 - 2 - 2 and 3- pole 3-pole - -
Star-delta switches 0 - Y - - 3- pole 3- pole -
Pole-change switches (Dahlander) 0 - A - AYY - 3- pole 3- pole -
Pumpstart switches 0 - 1 1- pole - - 1- pole
Stop switches 0R - Stop 2- pole - - -
Start switches Stop - Start - 1- pole - - -
0R - Start 1- pole - - -
0 -1R - Start 1- pole - - 1- pole
Start - 1R - 0 - 2R - Start - 1- pole - - 1- pole
Voltmeter switches
4 positions, 3 phase - 3 wire, with 0-position 0, L1-L2, L2-L3, L3-L1 3- pole - - 3- pole
3 positions, 3 phase - 3 wire, without
0-position
6 positions, 3 phase to phase, 3 phase to
neutral, without 0-position
7 positions, 3 phase to phase, 3 phase to
neutral, with 0-position
7 positions, 3 phase to phase voltages for 2
circuits, with 0-position
L1-L2, L2-L3, L3-L1 3- pole - - 3- pole
L1-L3, L2-L3, L1-L2,
L1-N, L2-N, L3-N
L1-L3, L2-L3, L1-L2,
0, L1-N, L2-N, L3-N
L1-L3, L2-L3, L1-L2,
0, L1-L3, L2-L3, L1-L2
Ammeter switches
For 3 current transformer circuits, with 0-position 0 - 1 - 2 - 3 1- pole 1 and 2- pole - - 1- pole
Volt-ammeter switches
3 phases and 3 current transformers with
common pole
Binarycode switches
OFF - 1 - 2 - 3 3- pole - - -
0-1-2-3-4-5-6-7...-9...-11 - 1 and 2- pole - - -
6
t
OL40
t
OL63-80
t
OL125-160
t
OL200
t
ON_M
Door mounted DIN rail mounted
1, 2, 3, 4, 5, 6 and 8- pole 1, 2, 3, 4, 6 and 8- pole 1, 2, 3 and 6- pole
1, 2, 3, 4, 5 and 6- pole - 1, 2, 3 and 6- pole
1, 2, 3 and 4- pole 1, 2, 3 and 4- pole 1, 2, 3 and 4- pole
1 and 3- pole 1, 2 and 3- pole - 1- pole
1, 2, 3 and 4- pole - - 1- pole
1, 2, 3 and 4- pole - - 1- pole
3- pole - - 3- pole
3- pole - - 3- pole
4- pole - - -
7
Rotary cam switches
Technical data
Ratings according to IEC60947-3
Size OM ON OL40 OL63 OL80N OL125 OL160 OL200
Impuls withstand voltage U
imp
Rated insulation voltage V 500 690 690 690 690 690 690 690
Rated operational voltage U
Rated thermal current I
Rated conditional short
circuit current
e
th
I
(r.m.s.) kA 1
p
Max back-up fuse link A 10 25 40 63 80 160 200 315
Rated short time withstand
3s A 100 360 630 800 1280 1280 1600
current (r.m.s)
10s A 60 200 300 400 700 700 1000
30s A 32 120 200 250 400 400 600
60s A 30 80 100 150 280 280 400
Rated operational current I
e
AC1 400V A 10 25 45 63 80 150 170 250
AC21 400V A 10 25 45 63 80 150 170 250
AC11 220-240V A 2.5 5.5 14 15 20 45 45 80
380-440V A - 3.5 6.0 10 15 45 45 80
500V A - 4.5 7.0 12 18 40 40 70
AC22 220-500V A 10 20 40 63 80 150 170 250
660-690V A - 20 40 63 80 100 100 125
Rated operational current Time constant 0...1ms
1-contact in series DC21 24V A 10 20 40 63 80 130 150 250
1-contact in series 48V A 10 20 40 63 80 130 150 250
2-contact in series 60V A 10 20 40 63 80 130 150 250
3-contact in series 110V A 10 20 40 63 80 130 150 250
5-contact in series 220V A 10 20 40 63 80 130 150 250
9-contact in series 440V A 10 20 40 130 150 250
10-contact in series 600V A 16 25
Rated operational current Time constant 1...50 ms
1-contact in series DC22 24V A 6 10 32 32 40 115 130 200
1-contact in series 30V A 3 4.5 11 32 40 36 40 50
1-contact in series 40V A 3 4.5 11 32 40 36 40 50
2-contact in series 60V A 3 4.5 11 32 40 36 40 50
3-contact in series 110V A 3 4.5 11 32 40 36 40 50
5-contact in series 220V A 3 4.5 11 32 40 36 40 50
Rated operational power
AC23 3 ph. 220-240V kW 1.8 2.6 7.5 12 14.5 37 37 56
380-440V kW 3 7.5 15 18 22.5 75 75 75
500V kW - 4.8 15 22 25 75 90 85
660-690V kW - 4.8 15 17 23 50 55 90
AC23 1 ph. 110V kW 0.37 0.5 2.5 3 3.6 9 11 14
220-240V kW 0.75 0.9
400V kW 1.1 1.5 7.5 9 12.5 35 37 45
Rated operational power
AC2 3 ph. 220-240V kW 2.5 3.5 11 16 18 35 37 70
380-440V kW - 6 18.5 24 30 50 55 95
500V kW - 6 18.5 24 33 65 75 103
660-690V kW - 6 18.5 26 35 65 55 110
AC3 3 ph. 220-240V kW 1.8 2.2 7.5 10 12 20 22 47
380-440V kW 2.2 5.5 11 15 19 35 37 64
500V kW - 4 11 15 22 35 37 82
660-690V kW - 4 11 17 23 30 30 88
1)
400 V
kV 2.5 4 6 6 6 6 6 6
V 250 400 690 690 690 690 690 690
A 10 25 45 63 80 150 175 315
1)
1)
7
10 10 10 10 10 10
A 10 25 45 63 80 150 160 250
4 6 7.2 20 22 30
16
1SCC302003C0201
Rotary cam switches
Technical data
Ratings according to IEC60947-3
Size OM ON OL40 OL63 OL80N OL125 OL160 OL200
AC3 1 ph. 110V kW 0.3 0.4 2.5 2.5 3 6 6 12
220-240V kW 0.55 0.75 4.0 5 6 11 11 24
400V kW 0.75 1.3 5.5 7.5 9 19 19 40
Terminals
Size OM ON OL40 OL63 OL80N OL125 OL160 OL200
Connecting screws M 2.5 3.5 5 5 5 5 5 10
Max cable cross section, solid/stranded mm
Contacts
Minimum voltage AC/DC V 5 5 5 5 5 5 5 5
Minimum current AC/DC mA 5 5 5 5 5 5 5 5
Standard butt contact
with plain contact tip
Butt contact with peak
type contact tip
Gold contacts (special) x x x x
Storing temperature
Operational temperature
1)
At 40°C, derating 0%
At 70°C, derating 30%
Current peaks up to 60°C, derating 0%
1)
2
1.5 4 6 16 16 70 70 150
AWG 14 14-12 14-8 10-6 10-6 12-2/0 12-2/0 kcmil 300
Size OM ON OL40 OL63 OL80N OL125 OL160 OL200
x x x x x x x
x
°C -40...+80 -40...+80 -40...+80 -40...+80 -40...+80 -40...+80 -40...+80 -40...+80
°C -30...+70 -30...+70 -30...+70 -30...+70 -30...+70 -30...+70 -30...+70 -30...+70
Ratings according to UL and CSA
Size OM ON OL40 OL63 OL80* OL125 OL160 OL200
Maximum operating voltage V 300 600 600 600 600 600 600
Pilot duty category CSA/UL VAC A300 A600 A600 A600 A600 A600 A600
Ampere
rating
Rated power 3-phase 120V HP 1 1 5 8 15 15 32
Short cicuit ratings
Maximum prospective fault current kA 1 10 10 10 10 10 10
Maximum fuse size A 16 35(RK5) 50(RK3) 80(RK5) 150(RK5) 200(RK5) 250(RK5)
Switching frequency cycles/hour 150 150 150 150 150 150 150
*)
The ratings for the older type OL80, see ON1GB 07_03 catalogue
General
use
at 600VAC UL A 10 25 40 80 125 170 200
1-phase 120V HP 0.33 1 2 4 10 10 -
UL 480V, CSA 600V
UL 600V
240V HP 1 2 10 16 40 40 64
480V HP - 5 20 28 40 50 120
600V HP - 5 20 31 40 50 120
240V HP 1 1 3 8 20 20 -
480V HP - 2 10 - - - -
600V HP - 3 10 - - - 10
A
A
10
-
25
16
40
80
-
-
125
-
170
200
-
17
1SCC302003C0201