3M Speciality Respirators Datasheet

Data Sheet for Speciality Respirators
Data Sheet
Main Features
The 3M Speciality range provides lightweight, effective, comfortable and hygienic respiratory protection against dusts and mists. It also provides additional relief from low levels of organic vapours or acid gases such as sulphur dioxide and hydrogen fluoride (depending on the product type). The convex shape, twin strap design, foam nose seal and aluminium nose clip ensures a good face seal over a range of face sizes. The patented 3MTM Cool FlowTM valve on the 9914 and 9926 and collapse resistant shell featured in all products offer both durable and comfortable protection particularly in hot and humid conditions. These respirators do not require costly and time consuming maintenance.
Approvals
These Speciality respirators have been shown to meet the Basic Safety requirements under Article 10 and 11B of European Community Directive 89/686. EC-Type examination certificates are in force issued by the British Standards Institution. The product is CE marked.
Materials
The following materials are used in the production of these products:
Straps - Polyisoprene
Nose Clip - Aluminium
Assigned
Protection
Factor for Fine
Particulate*
9906 4 Hydrogen fluoride
9915 4 Acid gases
9926 10 Same as 9915 Same as 9915
9913 and 9914
4 Organic vapours
Additional gas
and vapour
relief
only below WEL
including Hydrogen fluoride Sulphur Dioxide, Chlorine, all below WEL
below WEL
Application
Aluminium refining, stone cleaning, Acid cleaning and etching processes.
Same as 9906 plus Paper mills, Food processing, Coal power stations, Battery manufacturers, Smog in Cities.
Inks and dyes, Cosmetic manufacture, Electronics, Furniture manufacture, Food processing, Decorating/ Refurbishing, Hospitals and Forensic laboratories.
* Assigned Protection Factor (APF) as detailed in EN529
Filter - Polypropylene
Nose foam - Polyurethane
Valve - Polypropylene
Valve diaphragm - Polyisoprene
• Weight : 18g
WEL: Workplace Exposure Limit
Standards
Correct Usage
The product has been tested to the European Norm EN149:2001 and has met the requirements of categories shown below.
Product number EN149 performance category
9906, 9913, 9914, 9915 FFP1
9926 FFP2
The main performance tests in this standard are:
• Total Inward Leakage Ten test subjects perform a series of exercises while walking on a tread-mill. The amount of contamination leaking into the respirator through the filter, face seal and valve in measured. For category FFP1 the leakage must not exceed 22% and for FFP2 the leakage must not exceed 8% for eight of the ten results.
• Filter Penetration The filter efficiency of twelve respirators is tested against a sodium chloride aerosol and a paraffin oil aerosol. For the FFP1 category both aerosol penetrations must be below 20%. For the FFP2 category sodium chloride penetration must not exceed 6%.
The respirator may be used in concentrations of solid, water based and non-volatile liquid based aerosols up to 4 times the Workplace Exposure Limit for an FFP1 device and up to 10 times the Workplace Exposure Limit for an FFP2 device. It may also be used to remove the irritation caused by acid gases or organic vapours as specified in the Applications table at levels below the Workplace Exposure Limit.
(3M has also tested the filter against Hexane, Sulphur dioxide, Hydrogen fluoride and Chlorine gases although this is not a requirement of the EN149:2001 standard).
• Flammability Four respirators are individually passed through a flame at 800°C +/- 50°C at a speed of 5cm/sec.The respirators shall not continue to burn after removal from the flame.
• Breathing resistance The resistance created by the respirator filter to an airflow of 30 l/m and 95 l/m are evaluated. For an FFP1 device this must not exceed 0.6mbar and
2.1mbar at the respective flows. For an FFP2 device this must not exceed 0.7mbar and
2.4mbar at the respective flows.
• Information A range of information, specified in this standard, must be provided on the packaging of the product. A full copy of EN149:2001 can be purchased from your national standards body.