Mechanical Skin irritation: Signs/symptoms may include abrasion, redness, pain, and itching.
Eye Contact:
Mechanical eye irritation: Signs/symptoms may include pain, redness, tearing and corneal abrasion.
Dust created by grinding, sanding, or machining may cause eye irritation. Signs/symptoms may include redness, swelling,
pain, tearing, and blurred or hazy vision.
Ingestion:
No known health effects.
Carcinogenicity:
Ingredient CAS No. Class Description Regulation
SILICA, CRYS AIRRESP 14808-60-7 Known human carcinogen National Toxicology Program Carcinogens
Quartz Silica 14808-60-7 Grp. 1: Carcinogenic to humans International Agency for Research on Cancer
Titanium Dioxide 13463-67-7 Grp. 2B: Possible human carc. International Agency for Research on Cancer
Additional Information:
This product, when used under reasonable conditions and in accordance with the 3M directions for use, should not present a
health hazard. However, use or processing of the product in a manner not in accordance with the product's directions for use
may affect the performance of the product and may present potential health and safety hazards.
This document covers only the 3M product. For complete assessment, when determining the degree of hazard, the material
being abraded must also be considered.
This product contains titanium dioxide and quartz (crystalline) silica. Cancer of the lungs has been associated with inhalation
of high levels of titanium dioxide in animal studies, and occupational exposure to inhaled quartz silica has been associated
with silicosis and lung cancer. No exposure to titanium dioxide or quartz silica is expected during the normal handling and
use of this product. Titanium dioxide and quartz silica were not detected when air sampling was conducted during simulated
use of similar products containing these substances. Therefore, the health effects associated with titanium dioxide and quartz
(crystalline) silica are not expected during the normal use of this product.
Toxicological Data
If a component is disclosed in section 3 but does not appear in a table below, either no data are available for that endpoint or
the data are not sufficient for classification.
Acute Toxicity
Name Route Species Value
Overall product Ingestion No data available; calculated ATE > 5,000 mg/kg
Silicon Carbide Mineral Dermal Rat LD50 > 2,000 mg/kg
Silicon Carbide Mineral Ingestion Rat LD50 > 2,000 mg/kg
Titanium Dioxide Dermal Rabbit LD50 > 10,000 mg/kg
Titanium Dioxide Inhalation-
Dust/Mist
(4 hours)
Rat LC50 > 6.82 mg/l
Titanium Dioxide Ingestion Rat LD50 > 10,000 mg/kg
Quartz Silica Dermal LD50 estimated to be > 5,000 mg/kg
Quartz Silica Ingestion LD50 estimated to be > 5,000 mg/kg
ATE = acute toxicity estimate
Skin Corrosion/Irritation
Name Species Value
Silicon Carbide Mineral Rat No significant irritation
Titanium Dioxide Rabbit No significant irritation
Quartz Silica Professio
nal
No significant irritation