3M 90101 User Manual

3MPleated Foil Shielded Cable
.025 30 AWG Solid, TPE Primary, PVC Jacket 90101 Series
• Compatible with IDC mass termination connectors
• Functions with applications requiring standard impedance of 100 balanced (differential)
• Extremely low crosstalk, used in the all-signal mode to quadruple signal density as compared to standard .050 inch flat ribbon cable
• Solid pleated copper foil provides flexibility and 35 db average shielding effectiveness
• CL2 rated, rugged design and high reliability for peripheral applications
• RoHS* Compliant
Date Modified: January 19, 2005
TS-0285-19 Sheet 1 of 2
Jacket
Material:
Color:
Primary Material:
Marking:
Standard::
Conductors:
Shielding:
Polyvinyl Chloride (PVC)
Gray
Thermoplastic Elastomer (TPE)
(UL) CL2 75C 30 AWG 3M NU C AWM II A/B 80C 150V FT1 EU <50V
30 AWG [ 0.254 ] Tinned Stranded Copper
Solid, Pleated, Copper Foil
Electrical
Voltage Rating:
Insulation Resistance:
Characteristic Impedance:
Capacitance:
Inductance:
Propagation Delay:
Velocity of Propagation:
Note:Unbalanced is measured between ground-signal-ground conductors, with shield grounded. Balanced is measured between signal conductors within a pair, with the shield floating.
USA: N.E.C. 725, CL2 Canada: 150V EU: <50V
(Primary Cable)> 1 × 10
Unbalanced Balanced
53 104
28.4 pF/ft (93.2 pF/m) 14.5 pF/ft (47.6 pF/m)
.08 µH/ft (0.26 µH/m) .16 µΗ/ft (0.52µΗ/m)
1.52 ns/ft (4.99 ns/m) 1.51 ns/ft (4.95 ns/m)
67% 67%
10
/10 ft. [ 3m ]
Environmental
Temperature Rating:
Flammability Rating:
RoHS = Directive 2002/95/EC, Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment
UL File No.: E118773, Power Limited Circuit Cable: CL2
3M
Interconnect Solutions
http://www.3M.com/interconnects/
CL2: 75°C Canada: 80°C
USA: N.E.C. 725, CL2 Canada: FT1
3M is a trademark of 3M Company.
For technical, sales or ordering information call
800-225-5373
3MPleated Foil Shielded Cable
.025 30 AWG Solid, TPE Primary, PVC Jacket 90101 Series
Number of
Conductors
3M Part Number
Dimension A ± .030 Dimension B
20 90101/20 .60 [ 15.2 ] 0.475 ± .006 [ 12.07 ]
26 90101/26 .75 [ 19.1 ] 0.625 ± .006 [ 15.88 ]
36 90101/36 1.00 [ 25.4 ] 0.875 ± .009 [ 22.23 ]
40 90101/40 1.10 [ 27.9 ] 0.975 ± .009 [ 24.77 ]
50 90101/50 1.35 [ 34.3 ] 1.225 ± .009 [ 31.12 ]
68 90101/68 1.80 [ 45.7 ] 1.675 ± .012 [ 42.55 ]
80 90101/80 2.10 [ 53.3 ] 1.975 ± .015 [ 50.17 ]
100 90101/100 2.60 [ 66.0 ] 2.475 ± .017 [ 62.87 ]
Inch
[mm]
Tolerance Unless Noted
.0
Inch
A
B
.00 .000
±.05
±.1
[ ] Dimensions for
Reference only
±.010
.025 ± .002 Typ [ 0.64 ]
.10 ± .03 [ 2.5 ]
30 AWG [ 0.254 ] Tinned Solid Copper Conductors
Paper (Mfgr. Option)
Note: Blue marking on edge of primary cable designates wire #1.
Ordering Information
TPE Primary Insulation
.005 [ 0.13 ] Pleated Foil Shield with Adhesive Backing using Solid Copper Foil .001 [ 0.03 ] Thick
90101/XX
.026 (0.66) Min PVC Jacket
Note: Standard lengths are 100 ft., 150 ft. and 300 ft. rolls. Please specify when ordering,.
3M
Interconnect Solutions
http://www.3M.com/interconnects/
Number of Conductors (See Table)
For technical, sales or ordering information call
TS-0285-19 Sheet 2 of 2
3M is a trademark of 3M Company.
800-225-5373
Loading...
+ 1 hidden pages