3B Scientific Vacuum Experiment Plate User Manual

3B SCIENTIFIC
Vacuum Experiment Plate 1003166
Vacuum Bell Jar 1003167
Instruction sheet
12/12 ALF
®
PHYSICS
1 Polished flange
2 Grip knob 3 2 cocks for hose connec-
tion and for ventilation 4 4-mm safety plug
5 Centre bore hole with
M12 thread
6 Power feed using con-
nection cables and safety
sockets 7 Rubber sealing disc
8 Metal plate mounted on
tripod stand
1. Safety instructions
Protect the surface of the vacuum experi-
ment plate from moisture, chemicals and mechanical affects to guarantee that the system remains vacuum-tight.
Defective vacuum bell jars could implode.
Before conducting experiments check the
vacuum bell jar for any damage (entrapped air does not endanger operating safety).
2. Description
Vacuum experiment plate and vacuum bell jar are used to set up a vacuum chamber for ex­periments in the coarse (low) and fine vacuum range.
2.1 Vacuum Experiment Plate
The vacuum experiment plate comprises a me­tal plate with rubber sealing disc mounted on a tripod and two cock valves used for hose con­nection on the pump side as well as for ventila­tion. A center bore hole with M12 thread is used to secure experiment equipment. A vacuum-tight power feed with 4-mm safety sockets and two cables with 4-mm safety plugs are available for the power supply.
1
2.2 Vacuum Bell Jar
Vacuum bell jar made of glass with grip knob and polished flange to be set on top of the vac­uum experiment plate
3. Technical data
Vacuum experiment plate
Diameter: 250 mm Height: 90 mm Current feed-through: 2-pole with 4-mm safety
sockets
Power feed: via 2 cables approx. 1 m
in length with 4-mm sa-
fety plugs Electrical limit specs.: max. 48 V, max. 12 A Vacuum connection: 2 hose nozzles
12 mm and 8 mm Ø
Vacuum bell jar
Inner diameter:: 190 mm Height: 220 mm
4. Operation
To perform experiments the following equipment is also required:
1 Rotary-Vane Vacuum Pump, Two-Stage 1003317
1 Vacuum Hose 8 mm 1002619
Before performing the experiment check for
any damage to the vacuum bell jar.
Make sure that the sealing disc as well as
the polished edge of the bell jar are dust­free.
At the start of the experiment, press the
vacuum bell jar against the plate until air pressure provides sufficient force against the rubber seal, then let the bell jar go.
After performing the experiment ventilate the
chamber with the pump switched off and the evacuation valve closed.
3B Scientific GmbH Rudorffweg 8 21031 Hamburg Germany www.3bscientific.com
Technical amendments are possible
© Copyright 2012 3B Scientific GmbH