ATMOSPHERIC GAS • PACKAGED WATER HEATER
NICKELSHIELD® - NICKEL-PLATED STORAGE TANK
TANK SERIES 125 GALLONS
Model Number |
Recovery gph c |
Input |
* Min. Inlet Flow |
|
Dimensions |
|
Shipping |
|||
|
|
Gas Pressure |
|
|
(inches) |
|
Weight |
|||
|
|
Btu/h |
|
|
|
|||||
|
40° - 120°F |
40° - 140°F |
"W.C. |
B |
|
C |
|
E |
lbs |
|
|
|
|
|
|||||||
14 N 125A-G |
168 |
134 |
140,000 |
4.5 |
5 |
|
3/4 |
|
86 |
980 |
20 N 125A-G |
239 |
191 |
199,000 |
4.5 |
6 |
|
3/4 |
|
86 |
1030 |
27 N 125A-G |
324 |
259 |
270,000 |
4.5 |
7 |
|
3/4 |
|
86 |
1090 |
40 N 125A-G |
479 |
383 |
399,000 |
4.5 |
8 |
|
3/4 |
|
87 |
1170 |
54 N 125A-G |
648 |
518 |
540,000 |
6.5 |
10 |
|
1 |
|
87 |
1330 |
72 N 125A-G |
864 |
691 |
720,000 |
6.5 |
12 |
|
1 |
|
87 |
1430 |
80 N 125A-G |
960 |
768 |
800,000 |
7.0 |
12 |
|
1 1/4 |
|
87 |
1490 |
c Recoveries based on 80% thermal efficiency. ASHRAE 90.1 compliant for efficiency and standby loss.
*The information presented is for natural gas 0.6 S.G. – For operation with propane (LP gas), consult the factory.
*For operation outside this range, consult the factory. Dimensions are in inches unless otherwise notes.
For standard and optional equipment, see form #PV 6070.
STANDARD GAS PRESSURE REQUIREMENTS:
SEE TABLE FOR MINIMUM PRESSURE BY MODEL NUMBER.
MAXIMUM STATIC INLET GAS PRESSURE: 14 W.C.
FOR GAS PRESSURES OUTSIDE OF THIS RANGE,
CONTACT YOUR PVI REPRESENTATIVE.
ELECTRICAL REQUIREMENTS:
CONTROL VOLTAGE: 115V, 1Ø, 60 HZ., 2 AMPS
VENTING REQUIREMENTS:
TYPE B VENTING.
ENTIRE VENT SYSTEM SHOULD NEVER BE SIZED BASED UPON THE VENT CONNECTION DIAMETER EXCLUSIVELY.
CHECK NATIONAL FUEL GAS CODE UNDER "ATMOSPHERIC."
PVI RESERVES THE RIGHT TO CHANGE THE DESIGN AND SPECIFICATION WITHOUT NOTICE.
Product is patented in the U.S., Canada, and Mexico.
|
PVI INDUSTRIES, LLC |
|
|
|
|
PV 5369 07/04 |
FORT WORTH, TEXAS 76111 |
|
|
|
|
(800) 784-8326 • www.pvi.com |
|
|
|
|
|
|
|
|
|