TURBOPOWER® OIL |
PACKAGED WATER HEATER |
|
||||||||||||||
|
|
|
NICKELSHIELD® NICKEL-PLATED STORAGE TANK |
|
|
|
||||||||||||
|
|
|
|
|
|
TANK SERIES 400 GALLONS |
|
|
|
|
|
|
|
|||||
|
|
Recovery gph |
|
|
|
Dimensions (inches) |
|
Blower |
Shipping |
|||||||||
Model |
Input |
|
Gph |
|
Motor |
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
Weight |
||||||
Number |
|
|
|
|
Btu/h |
|
#2 Oil |
|
|
|
|
|
|
|
|
Volt/Ph/ |
||
40°- 120°F |
|
40°- 140°F |
|
A |
B |
|
J |
K |
HP |
|
lbs |
|||||||
|
|
|
|
|
|
|
|
Amps |
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
250 |
N 400A-TPO |
250 |
|
200 |
199,000 |
|
1.4 |
29 |
4 |
|
17 |
|
39 |
1/3 |
|
115/1 /8 |
1700 |
|
500 |
N 400A-TPO |
500 |
|
400 |
399,000 |
|
2.8 |
29 |
5 |
|
17 |
|
39 |
1/2 |
|
115/1 /10 |
1720 |
|
750 |
N 400A-TPO |
750 |
|
600 |
600,000 |
|
4.3 |
32 |
6 |
|
17 |
|
39 |
1/2 |
|
115/1 /10 |
1800 |
|
1000 |
N 400A-TPO |
1000 |
|
800 |
800,000 |
|
5.7 |
32 |
8 |
|
17 |
|
39 |
1/2 |
|
115/1 /10 |
1840 |
|
1250 |
N 400A-TPO |
1250 |
|
1000 |
1,000,000 |
|
7.2 |
49 |
8 |
|
17 |
|
39 |
1/2 |
|
115/1 /10 |
2080 |
|
1500 |
N 400A-TPO |
1500 |
|
1200 |
1,200,000 |
|
8.6 |
49 |
8 |
|
17 |
|
39 |
1/2 |
|
115/1 /10 |
2090 |
|
2000 |
N 400A-TPO |
2000 |
|
1600 |
1,600,000 |
|
11.4 |
61 |
10 |
|
25 |
|
39 |
1-1/2 |
|
115/1 /20 |
2530 |
|
2500 |
N 400A-TPO |
2500 |
|
2000 |
2,000,000 |
|
14.3 |
61 |
10 |
|
25 |
|
39 |
1-1/2 |
|
115/1 /20 |
2550 |
|
3000 |
N 400A-TPO |
3000 |
|
2400 |
2,400,000 |
|
17.1 |
60 |
12 |
|
25 |
|
50 |
1-1/2 |
|
115/1 /20 |
2560 |
|
3500 |
N 400A-TPO |
3500 |
|
2800 |
2,800,000 |
|
20.0 |
60 |
12 |
|
25 |
|
50 |
5 |
|
230/3 /16 |
2590 |
|
4000 |
N 400A-TPO |
4000 |
|
3200 |
3,200,000 |
|
22.8 |
60 |
12 |
|
25 |
|
50 |
5 |
|
230/3 /16 |
2640 |
Recoveries based on 83% thermal efficiency. ASHRAE 90.1 compliant for efficiency and standby loss. "J" dimension is for the burner housing only.
4" x 42" Channel skids for inputs ≤ 1000 MBtu/h. 4" x 53" Channel skids for inputs > 1000 MBtu/h.
Dimensions are in inches unless otherwise specified. For standard and optional equipment, see form PV 6004.
VENTING REQUIREMENTS
-.02" TO -.06" W.C. (NEGATIVE PRESSURE)
ENTIRE VENT SYSTEM SHOULD NEVER BE SIZED BASED UPON THE VENT CONNECTION DIAMETER EXCLUSIVELY.
FOR PROPER SIZING, CONSULT VENTING SUPPLIER.
* REAR ACCESS MODULE
MODEL PREFIX |
M |
L |
STD or OPTIONAL |
|
|
|
|
250-1500 |
23" |
8" |
OPTIONAL |
|
|
|
|
2000-2500 |
23" |
18" |
STANDARD |
|
|
|
|
3000-4000 |
30" |
25" |
STANDARD |
|
|
|
|
STANDARD ELECTRICAL REQUIREMENTS
CONTROL VOLTAGE: 120V, 1Ø, 60 HZ., 2 AMPS. MOTOR VOLTAGE:
208V, 230V, AND 460V MOTORS ARE AVAILABLE BUT WILL REQUIRE A SEPARATE 120V/2 amps CONTROL CIRCUIT OR AN OPTIONAL CONTROL CIRCUIT TRANSFORMER.
PVI RESERVES THE RIGHT TO CHANGE THE DESIGN AND SPECIFICATION WITHOUT NOTICE.
PVI INDUSTRIES, LLC
FORT WORTH, TEXAS 76111
PV 5420 04/05 |
(800) 784-8326 (817) 335-9531 www.pvi.com |
Product is patented in the U.S., Canada, and Mexico. |
|
|