Introduction: The multiple award-winning F8 LED Fresnel platform
from Zylight is the next generation of Fresnel lights. The F8-200 boasts
a high CRI (color rendering index) and a quality of light matched only
by traditional sunlight and incandescent bulbs, while using a fraction of
the energy. The F8-200 LED Fresnel is part of Zylight’s pursuit of high
quality, affordable, intelligent xtures. The unit can be controlled
manually, wirelessly or via DMX controller.
Every F8-200 LED Fresnel has been thoroughly tested and has been
shipped in optimal operating condition. Carefully check the shipping
carton for damage that may have occurred during shipping. If the
carton appears to be damaged, carefully inspect your xture for any
damage and be sure all accessories necessary to operate the unit have
arrived intact. If damage has been found or parts are missing, please
contact our customer support number for further instructions. Do not
return this unit to your dealer without rst contacting customer
support.
Your F8 includes the following items:
• One – F8 4-way barn door
• One - Yoke bar with 5/8” baby pin adapter
• One - Yoke adjustment knob
• One – Slotted thumbscrew
• Two - 1/4" x .69" OD nylon washers (g 1)
• Three - 1/2" x .75" OD nylon washers (g 2)
• One - Serrated #10/M5 x .36" OD, .02" Stainless Washer (g 3)
• One - Worldwide AC adapter
• One - AC adapter hanging pouch (for light stand use)
• One - Barn door safety cable
• One – F8 User Guide
• One - Zylight F8-200 LED light head
Page 1
g 2g 3g 1
10718 McCune Avenue
Los Angeles, CA 90034
info@zylight.com
www.zylight.com
Optional Accessories:
# 26-02012- F8 Chimera Kit # 19-02028- F8 Egg Crate (50 deg.)
# 26-02036- F8-200 Batt. Module (Gold Mt) # 26-02037- F8-200 Batt. Module (V-Mt)
# 26-02019- DMX Interface Box # 19-02041- F8 Handle Kit
# 19-01012- F8 Snoot (Black) # 19-01013- F8 Snoot (White)
# 19-02039- F8 Single Head Case # 19-02040- F8 Dual Head Case
# 26-02044- IP65 AC Supply Kit # 26-02014- F8 Pole Yoke Mount
Customer Support: Zylight provides a customer support line, to
provide set up help and to answer any question should you encounter
problems during your set-up or initial operation. You may also visit us
on the web at www.zylight.com for any comments or suggestions.
Service Hours are Monday through Friday 9:00 a.m. to 5:00 p.m.
Eastern Standard Time.
Caution! There are no user serviceable parts inside this unit. Do not
attempt any repairs yourself; doing so will void your manufacturer's
warranty. In the unlikely event your unit may require service please
contact Zylight customer support.
PLEASE recycle the shipping carton whenever possible.
General Instructions
To optimize the performance of this product, please read these
operating instructions carefully to familiarize yourself with the basic
operations of this unit. These instructions contain important safety
information regarding the use and maintenance of this unit. Please
keep this manual with the unit for future reference.
Warranty Registration
The F8-200 Fresnel carries a two year limited warranty. Please go to
www.zylight.com/product-registration to register your product and
validate your purchase. All returned service items whether under
warranty or not, must be freight pre-paid and accompany a return
merchandise authorization (R.A.) number. The R.A. number must be
Page 2
clearly written on the outside of the return package. A brief description
of the problem as well as the R.A. number must also be written down
on a piece of paper included in the shipping carton. If the unit is under
warranty, you must provide a copy of your proof of purchase invoice.
You may obtain an R.A. number by contacting our customer support
team through our customer support number. All packages returned to
the service department not displaying a R.A. number on the outside of
the package will be returned to the shipper.
Safety Precautions
Ultraviolet Radiation Warning
The F8-B (blacklight) xture contains a high
intensity LED ultraviolet emitter which is
concentrated with a Fresnel lens. When this
xture is used in accordance with the
manufacturers operating instructions, no hazards
exist to most people standing within the beam of the xture. However,
individuals suffering from a range of sunlight exposure disorders,
aphakic and pseudophakic, or those individuals receiving
photosensitive medication may receive discomfort if exposed to
ultraviolet light. For reective, not direct use. Avoid frequent or lengthy
exposure. Exposure can cause eye and skin injury and allergic
reactions. Repeated exposure may cause chronic sun damage and
skin cancer. Do not look directly into the xture while in operation.
Wear protective eyewear. Failure to use protective eyewear may result
in severe burns or long-term injury to the eyes.
(F8-B Only):
IP Rating (All F8s):
The F8-200 is rated IP54 for weather resistance, including the silent
operation fan located on the back of the xture. Ingress of dust is not
entirely prevented, but it will not interfere with satisfactory operation.
Splashing water or light rain or snow will also have no harmful effect.
While the F8-200 is protected against light moisture and dust
exposure, the standard AC power supply is not. (If you require AC
power in wet or damp conditions, use the optional ange mounted
IP65 rated supply.) Please protect the instrument when shooting in
extreme conditions and note that the instrument is not rated to be
submerged in water, or exposed to prolonged periods of moisture.
Always use your best judgment and protect the instrument from
sustained moisture exposure.
Page 3
Safety Precautions Cont.
The F8-200 is equipped with a temperature sensor and fan control. In
the unlikely event that the fan malfunctions or the xture operates at
too high a temperature, the xture will put itself into a safe mode and
limit the light output. At rst, the xture will drop its maximum power
to 80% of full output. The display will ash a warning for
“TEMPERATURE” to let the operator know it is running at reduced
power. If the temperature continues to be out of range, the unit will
continue to protect itself and operate at 50% of maximum output and
display a “TEMPERATURE” mode warning. All of these extreme use
case power reductions are rare. The light will return to normal
operation when cool and power cycled. The unit can and will operate
at 50% power without the assistance of a fan. In the unlikely event the
temperature reaches a critical state, the xture will turn itself off. “FAN
FAULT” will display in the unlikely event of a fan obstruction or failure.
Please refer any error codes to Zylight’s service department.
• To reduce the risk of electrical shock or re, do not submerge this xture in water.
• Do not spill large amounts of water or other liquids into or on to your xture.
• Do not attempt to operate this unit if the power cord has been frayed or broken. Do not
attempt to remove or break off the ground prong from the electrical cord. This prong is
used to reduce the risk of electrical shock and re in case of an internal short.
• Disconnect from main power before making any type of connection.
• Do not remove the lens under any conditions. There are no user serviceable parts inside.
• Never operate this xture if the Fresnel lens is removed.
• Never plug this unit into a dimmer pack.
• Always be sure to mount this xture in an area that will allow proper ventilation. Allow at
least 6" (15cm) between this device and a wall.
• Do not attempt to operate this xture if it becomes damaged.
• During long periods of non-use, disconnect the xture's main power.
• Always mount this xture in safe and stable matter. Always use a safety cable as part of
a secure installation. This includes securing the barn doors with a safety cable.
• Power-supply cords should be routed so that they are not likely to
be walked on or pinched by items placed upon or against them,
paying particular attention to the point they exit from the xture.
• Cleaning: The xture should be cleaned only as recommended by the manufacturer. See
page 10 for cleaning details.
• Heat: The instrument should be situated away from heat sources such as radiators, heat
registers, stoves, or other appliance (including ampliers) that produce heat.
• The xture should be serviced by qualied service personnel when:
A. The power-supply cord or the plug has been damaged.
B. Objects have fallen, or liquid has been spilled into the instrument.
C. The instrument has been submerged in water.
D. The standard AC power supply has been exposed to water, prolonged weather, or
dampness.
E. The instrument does not appear to operate normally or exhibits a marked change in
performance.
Page 4
First Set Up – Assembly Instructions
To optimize the correct performance of your xture, please follow these simple
assembly instructions, and refer to this manual if you ever need to reattach the
yoke assembly to your xture.
In some instances, the yoke assembly will be shipped separated from your
xture. There are several nylon washers that are be used to correctly space the
metal parts from one another. This will also allow the F8-200 to be adjusted and
tightened with only one lock point on the left or right side of the yoke. Proper
installation of the washers on the pivot points and the lock points are essential
to maintain the correct operation of the xture.
The lock point (yoke knob) can be mounted on the left or right side of the
instrument, although it is recommended in most common set ups to keep the
lock point on the right side of the xture (righty tighty). To install the yoke, lay
the instrument on top of a protected surface. Layout your components to
mimic the conguration shown in Figure 1. The side with the thumbscrew
should have the Serrated # 10/M5 x .36 OD, stainless washer and two of the
1/2" x .75 nylon washers. The side with the knob lock should have one 1/2" x
.75 nylon washer and the two 1⁄4” x .69 nylon washers. First place a 1/2" x .75
nylon washer around each side of the pivot located on each of the yoke ears
(Fig 2).
Next, set the yoke orientation to “lean forward.” You will notice that the base of
the yoke has been shaped so when the yoke mount is vertical in a stand or
perpendicular to the ground, the yoke will sit at an angle towards the front of
the light. This is so the xture can be pointed further down towards your
subject when placed on a stand (Fig 3).
Install the center of the yoke and capture each side of the pivot point screws.
You may need to gently stretch the yoke to engage the pivot point screws. Slide
the small serrated stainless washer onto the slotted thumbscrew (Fig 4). Note
the slight bend in the washer’s prole. The outer edge should touch the
thumbscrew (convex side), while the center points towards the pivot point
(concave side). Then take the third 1⁄ 2” x .75 nylon washer and install on the
top of the yoke on the side that will have the thumbscrew (Fig 5). Install the
slotted thumbscrew into the pivot point, being sure to properly capturing the
nylon washer. Tighten the thumbscrew with a coin or other device only nger
tight. (Fig 6). Now ip the instrument to the other yoke point. Slide a 1⁄4” x .69
nylon washer under the yoke at the lock point where the threaded hole will
accept the 1⁄4-20“ yoke knob (Fig 7). Place the other 1⁄4” x .69 nylon washer
onto the yoke knob and tighten into the threaded hole, being sure to capture
the nylon washer below (Fig 8). This completes the proper installation of the
yoke assembly to the F8-200.