ZyCast digi-MOD RL-DM1102M User Manual

ZyCast
R
RL-DM1102M Single Input IR
DVB-T Encoder / Modulator
User Guide and Install Manual
Table of Contents
Radio Frequency Range
Safety Precautions ................................................................................................................................................................................2
Package Contents ...................................................................................................................................................................................
Product Description ...............................................................................................................................................................................2
............................................................................................................................................................................................
Installation .............................................................................................................................................................................................4
Hardware Installations and Connections ...............................................................................................................................................4
Connecting to the GUI Interface ............................................................................................................................................................4
IR Return Path .......................................................................................................................................................................................4
Encoder Programming and Setup via GUI Interface .............................................................................................................................5
Overview Page of digi-MOD Encoder....................................................................................................................................................5
Common Setup ...............................................................................................................................................................6
RF Setup .........................................................................................................................................................................6
Encoder Setup ..................................................................................................................................................................
.....................................................................................................................................................8
Administration .................................................................................................................................................................8
...............................................................................................................................................................9
Front Panel LCD Encoder Menu Map .....................................................................................................................................................
.....................................................................................................................................10
Installing Multiple Encoders in the Same Installation (Stacking) ...........................................................................................................0
IR Distribution ......................................................................................................................................................................................10
Notes ...................................................................................................................................................................................................13
www.digi-modbyzycast.com
RL-DM1102M User Guide and Install Manual Page 2
Safety Precautions
Package Contents
Product Description
The presence of this symbol is to alert the installer and user to the presence of uninsulated dangerous voltages within the product’s
enclosure that may be of sufcient magnitude to produce a risk of electric shock.
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS DEVICE TO RAIN OR MOISTURE. DO NOT OPEN THE UNIT. REFER SERVICING TO QUALIFIED PERSONNEL ONLY.
Do not apply power to the unit until all connections have been made, all components have been installed and all wiring has been properly terminated.
Do not terminate, change or uninstall any wiring without rst disconnecting the unit’s power adapter from the device.
This device is supplied with the appropriately rated power supply. The use of any other power supply could cause damage and
invalidate the manufacturer’s warranty.
Do not connect the power cord to the device if the power cord is damaged.
Do not cut the power cord.
Do not plug the power cord into an AC outlet until all cables and connections to the device have been properly connected.
• The device should be installed in an environment consistent with its operating temperature specications. Placement next to
heating devices and ducts is to be avoided as doing so may cause damage. The device should not be placed in areas of high humidity.
Do not cover any of the device’s ventilation openings.
If the device has been in a cold environment allow it to warm to room temperature for at least 2 hours before connecting to an
AC outlet.
This package contains:
One RL-DM1102M Encoder / Modulator
One power adaptor
• One installation / conguration manual
Inspect the package before starting installation to ensure there is no damage and all supplied contents are present. Contact your distributor or dealer should the device be damaged or package contents are incomplete.
resi-linx digi-MOD Series Encoder/ Modulators provides a DVB-T output stream - making it ideal for any RF Network.
Front panel LCD Display for easy installation
LCN MODE
Composite, Component, and S-Video inputs
MPEG2 Video Output
RJ45 for web management
Selectable Constellation
85dB Output
Silent Operation
Compact Design
IR Return Path
RL-DM1102M User Guide and Install Manual Page 3
Specication
VIDEO INPUTS (VIDEO BY PRIORITY)
Component YPrPb (RCA)
Composite CVBS (RCA)
S-Video S-Video
AUDIO INPUTS
Audio Inputs L/R (RCA)
VIDEO ENCODER
Mode MPEG-2
Video Resolutions 576i, 480p, 480i
AUDIO ENCODER
Audio Compression MPEG-1 Layer II
RF DVB-T SUPPORT
Frequency Channel Plan
RF Channel Output 1 RF Output
Constellation 64QAM (16QAM)
Bandwidth 7 MHz
RF Level Output 85dB
MER >32dB Typical
FEC 1/2, 2/3, 3/4, 5/6, 7/8
Guard Interval 1/4, 1/8, 1/16, 1/32
OFDM 8K (2K)
Attenuation 1-20dB (1dB steps)
RF Output "F" - Female 75 ohm
MANAGEMENT / CONTROL
Front Panel LCD Control Full Support (Up/Doen/OK Buttons)
GUI IE9, Firefox, Chrome, Safari
Password Protected Front Panel, GUI
RL-DM1102M User Guide and Install Manual Page 4
System Installer must adhere to Article 820-40 of the NEC that provides guidelines for proper grounding and species that the cable ground shall be connected to the grounding system of the building, as close to the point of cable entry as possible.
UNPACKING AND INSPECTION
Each unit is shipped factory tested. Ensure all items are removed from the container prior to discarding any packing material.
Thoroughly inspect the unit for shipping damage with particular attention to connectors and controls. If there is any sign of damage to the unit or damaged or loose connectors contact your distributor immediately. Do not put the equipment into service if there is any indication of defect or damage.
It is highly recommended that quality cables and connectors be used for all video and audio source connections.
1. The unit comes with Component, Composite and S-Video inputs. Component Video Cable, connect the Y (Green), Pb (Blue),
and Pr (Red) video source cable to the unit’s Component input ports. If using a Composite Video source, use a cable with RCA connectors to connect the video source (e.g., CATV, DVD, VCR, Camera) to the unit’s CVBS port. If using a S-Video source, use an S-Video cable to connect the video source to the units S-Video port.
2. Audio inputs: Connect A/V audio input (Left / Right Audio) use RCA cables to connect the audio source to the red / white
AUDIO L and AUDIO R INPUT jacks.
3. Be sure the video and audio connections for each source are consistent with the unit’s inputs.
4. Use a quality 75Ω coaxial cable with “F” connectors from the unit’s RF OUT socket to the distribution system (combiner or
reverse splitter) or directly to a television.
5. Connect the included power adaptor to the unit’s POWER socket.
6. Connect the power adaptor to an appropriately rated AC power outlet.
To setup and program the Encoder you can use the GUI interface or the LCD Front Panel.
1. Connect an Ethernet cable directly (no Cross Over cable required) to the Web Management Port on the rear panel of the
encoder or connect the Ethernet cable to an Ethernet switch. Connect an Ethernet Cable to your PC.
2. Using a Windows-based PC Select Windows Icon
3. Go to My Computer
4. Select Network
5. Allow UPnP to locate and list the device(s) in the right panel
6. Right Click and Select “View device Webpage”.
Installation
Hardware Installations and Connections
DEVICE Programming and Setup
Connecting to the GUI Interface
NOTE:
For Setup Using Front Panel LCD: Go to page 10 in this manual.
IR Return Path
1. Connect IR emitters RL-IR700/800 to the output on the rear of the RL-DM1102M Modulator. Place the other end of the emitter on your AV device near the IR pick up.
2. Connect the RF Output from the RL-DM1102M to the Modulator Input on the RF Distribution Module RL-RF380. Alternatively
connect the RF Output to an existing distribution system or driectly to a television set.
NOTE: When Remote Power Switch is ON - the RL-RF380 should not have a Power Supply connected.
RL-DM1102M User Guide and Install Manual Page 5
After connecting the device to the “Web Management” port located on the rear of the device and locating the device via the
‘Network’ tool in ‘My Computer’
STEP 1: Right Click and Select “View device Webpage”.
Overview status of the Encoder when fully functioning.
STEP 2: Login Select Common Setup
Once the Common Setup Tab is selected you will be prompted to enter the user name and password for device:
STEP 3: Common Setup Tab
Common Setup: Use the Common Setup Page to set the Output channel, Attenuation, LCN Mode, and Device Address.
Encoder Programming and Setup via GUI Interface
Overview page of resi-linx digi-MOD
Default User Name: admin Default Password: Admin123
RL-DM1102M User Guide and Install Manual Page 6
STEP 4: Local Save
Once all parameters are set you are required to do a Local Save.
Notes on Changes: Changes made to an individual setup tab may require the installer to perform a Local Save AND Upload and Reboot to the device if you are only making changes to one parameter to the encoder.
Example: Installer is required to change only the output channel for the device (No other changes to the device are not required). Once the channel has been changed, the installer is required to perform
1. Local Save and
2. Upload and Reboot.
STEP 5: RF Setup
Use the RF Setup Page to setup the RF Output.
STEP 6: Local Save
Once all parameters are set you are required to do a Local Save.
RL-DM1102M User Guide and Install Manual Page 7
STEP 7: Encoder Setup
STEP 8: Local Save Encoder tab
Once all parameters are set you are required to do a Local Save on Encoder Tab where changes were performed
Note: Local Save function will indicate the local change made
Upload and Reboot after all changes have been made and a Local Save performed
IMPORTANT NOTE:
Ensure all Encoder changes have been locally saved before performing Step 9.
STEP 9: Upload and Reboot
Once you have set all the encoder settings and performed a Local Save for each encoder
Select “Upload and Reboot” after you have saved all your Local changes on each Tab. This function will upload and save all
parameters set in the Common, RF, and Encoder sections of the device.
We highly recommend you save your encoder conguration les. See Administration tab for how to back you device settings.
RL-DM1102M User Guide and Install Manual Page 8
STEP 10: Network Conguration Tab
Use the Network Setup Tab to congure the device’s IP address, Subnet Mask, Gateway, Enable/Disable DHCP, and set Host
Name.
STEP 11: Save Network Conguration
Save Cong: Once all parameters are set you are required to select Save Cong.
This function will reboot and save the changes setting for the Network Conguration.
STEP 12: Administration
NOTE:
Only the Network Conguration
changes will be saved.
ADMINISTRATION PAGE FUNCTIONS ACTIONS
Reboot Reboot device. All unsaved settings will be lost.
Reset to Default Reset all settings back to original factory settings
Backup Download all settings of device
Upload Upload a saved cong le
New Password Create and save new password for GUI
RL-DM1102M User Guide and Install Manual Page 9
IMPORTANT NOTE:
We highly recommend you save your encoder
conguration les. Simply Click the “Backup” button and the cong les will be saved to your computer.
NOTE:
When setting a new password you must use the ‘Submit’ button.
To upload a conguration le- simply click “Choose File” then locate the le you want to upload. Click “Upload” to install the conguration les. This function is helpful to the installer when
installing a large number of encoders in a single system.
Saving your conguration les
STEP 13: If required, change GUI Password and Submit.
This password is for access to the GUI only. The LCD front Panel Password will not be changed and is set to prevent unauthorized users access to your device.
Front Panel LCD Encoder Menu Map
COMMON SETUP
Output Channel
Attenuation
LCN Mode
Device Address
Default Conguration
Back to Main
RF SETUP
Select RF
Constellation
FEC
Guard Interval
OFDM
Cell ID
TS ID
Network ID
Org Network ID
Network Name
Back to Main
ENCODER SETUP
Video Format
Video Input
Program Num
Channel Name
Provider Name
LCN
Aspect Ratio
Brightness
Contrast
Saturation
Hue
Back to Main
NETWORK SETUP
Reset Network DHCP, IP address, Subnet Mask, Gateway
Back to Main
EXIT
RL-DM1102M User Guide and Install Manual Page 10
Modulator Conguration via Front Panel LCD
Once the encoder is powered up it will go through its initial booting process. Once the unit has completed its initial “Booting” up
process the LCD will display IN-1..., Bit Rate information, Channel-1...., and other information in the LCD Display Window. When
visible the unit is ready for programming or operation.
Main Menu – To access the Main Menu rst enter the password by pressing the OK button. Use the Scroll Up/Down buttons to enter the password. Once the password is entered press the OK button again and the LCD Screen will display “Main Menu Common Setup”.
Password – Use the Scroll Up/Down buttons to enter the password. Password is 0000. Press the OK button for each number
to enter the password. Press OK again after the display shows …...
COMMON SETUP MENU
Output Channel – Use the Scroll Up/Down button to change the output channel. Use the Scroll Up/Down buttons to select the desired output channel. Once the desired output channel is selected press the OK button to set the channel. The LCD Display
will show both the channel number and the frequency number of the output channel (example: 21 480.5000MHz).
Attenuation – Use the Scroll Up/Down button to select Attenuation. Press the OK button to enter the Attenuation menu. Use the
Scroll/Up down button to select the desired attenuation in 1dB increments from 0 to minus 20 dB. Once the desired attenuation level is found press the OK button to set.
LCN – Use the Scroll Up/Down button to select LCN MODE. Press the OK button to enter the LCN menu. Menu options are APN, NORDIG, ITC, and EACEM. Factory default: APN. Use the Scroll Up/Down button to select the desired LCN and press he OK button to set.
Device Address – Use the Scroll Up/Down button to select Device Address. Press the OK button to enter the Device Address menu. Use the Scroll Up/Down to select the Desired Address ranging from 1 to 255 then press OK to set. A unique device address is required if setting up more than 1 encoder per site. This allows the user to distinguish each device.
Default Conguration –To reset the Encoder/Modulator back to the factory default select the Default Conguration Menu. Press OK to enter the Default Conguration Menu. Using the Up/Down button select YES to reset all programmed settings back
to the factory default setting. Factory Default: NO.
Caution: Once the “YES” button is pressed the unit will automatically reset to the factory default settings. All settings or changes to the encoder/modulator will be lost.
Back to Main – Select Back to Main to escape the Common Setup Menu.
RF SETUP MENU
Select RF – Press the OK button to enter the Select RF menu. Use the Scroll Up/Down button to Select the RF section of the Encoder.
Constellation – Use the Scroll Up/Down button to select Constellation. Press the OK button to enter the Constellation menu. Select the desired Constellation / QAM setting then press the OK button to set.
FEC – Use the Scroll Up/Down button to select the FEC menu. Press the OK button to enter the FEC menu. Use the Scroll Up/ Down button to select the desired FEC setting and press the OK button to set.
Guard Interval – Use the Scroll Up/Down button to select Guard Interval. Press the OK button to enter the Guard Interval menu. Use the Scroll Up/Down button to select the desired Guard Interval and press the OK button to set.
OFDM – Use the Scroll Up/Down button to select the OFDM menu. Press the OK button to enter the OFDM menu. Use the Scroll Up/Down to select the OFDM 2K or 8K. Press OK to set.
CELL ID – Use the Scroll Up/Down button to select CELL ID. Press the OK button to enter the CELL ID menu. Use the Scroll Up/Down button to select the desired CELL ID ranging from 0 to 65535 then press the OK button to set. Factory default is 0.
TS ID – Use the Scroll Up/Down button to select TS ID. Press the OK button to enter the TS ID menu. Use the Scroll Up/Down button to select the desired Stream ID ranging from 0 to 65535 then press the OK button to set.
Network ID – Use the Scroll Up/Down button to select Network ID. Press the OK button to enter the Network ID menu. Use the Scroll Up/Down button to select the desired Network ID ranging from 0 to 65535 then press the OK button to set.
ORG Network ID – Use the Scroll Up/Down button to select ORG Network ID. Press the OK button to enter the ORG Network ID menu. Use the Scroll Up/Down button to select the desired ID ranging from 0 to 65535 then press the OK button to set.
Network Name – Use the Scroll Up/Down button to select Network Name. Press the OK button to enter the Network Name menu. Use the Scroll Up/Down buttonto select the rst character for the desired Network Name then press the OK button to set.
Repeat the process for each character in the desired Network Name. A Network Name can consist up to 16 characters.
Back to Main – Select Back to Main to escape the RF Setup Menu.
RL-DM1102M User Guide and Install Manual Page 11
ENCODER SETUP MENU
Select Encoder – Use the OK button to enter the Select Encoder Menu.
Video Format – Use the Scroll Up/Down button to select Video Format. Press the OK button to enter the Video Format menu.
Use the Scroll Up/Down button to select the Video Input option: Auto, Composite (CVBS), Component, S-Video. Factory default: CVBS. Press the OK button to set.
Program Num – Use the Scroll Up/Down button to set 1 Program Num(Number). Press the OK button to enter the Program Num menu. Use the Scroll Up/Down to select the Program Num ranging from 1 to 65535 then press OK to set.
Channel Name – Use the Scroll Up/Down button to select Channel Name. Press the OK button to enter the Channel Name menu. Use the Scroll Up/Down menu to select the rst character of the desired Channel Name then press the OK button to
set. Repeat the process until the Channel Name is completed. The Channel Name can be 7 characters long. Factory Default: CHANNEL-1.
Provider Name – Use the Scroll Up/Down button to select Provider Name. Press the OK button to enter the Provider Name menu. Use the Scroll Up/Down menu to select the rst character of the desired Provider Name then press the OK button to set.
Repeat the process until the Provider Name is completed.. The Provider Name can be 16 characters long.
LCN – Use the Scroll Up/Down button to set LCN. Press the OK button to enter The Source ID menu. Use the Scroll Up/Down to set the Source ID. Range: 1 to 999. Press OK to set.
Aspect Ratio – Use the Scroll Up/Down button to select Aspect Ratio. Press the OK button to enter the Aspect Ratio menu.
Use the Scroll Up/Down button to select the desired Aspect Ratio option of 4:3 or 16:9 then press the OK button to set. Factory
default: 4:3.
Brightness – Use the Scroll Up/Down button to select Brightness. Press the OK button to enter the Brightness menu. Use the Scroll Up/Down button to select the desired Brightness value (0 to 255) and press the OK button to set. Factory default: 128.
Contrast – Use the Scroll Up/Down button to select Contrast. Press the OK button to enter the Contrast menu. Use the Scroll Up/Down button to select the desired Contrast value (0 to 255) and press the OK button to set. Factory default: 128.
Saturation – Use the Scroll Up/Down button to select Saturation. Press the OK button to enter the Saturation menu. Use the Scroll Up/Down button to select the desired Saturation value (0 to 255) and press the OK button to set. Factory default: 128.
Hue – Use the Scroll Up/Down button to select Hue. Press the OK button to enter the Hue menu. Use the Scroll Up/Down button to select the desired Hue value (0 to 255) and press the OK button to set. Factory default: 128.
Back to Main – Select Back to Main to escape the Encoder Setup Menu
NETWORK SETUP: DHCP / IP Address / Subnet Mask / Gateway
Reset Network – Select Reset Network from the Network Setup to Reset the Network settings.
Back to Main – Select Back to Main to escape the Encoder Setup Menu.
ITEM VALUE
Password
Serial Number
Installation Date
Purchase Date
Video Input 1
RL-DM1102M User Guide and Install Manual Page 12
The following changes are required when using multiple modulators in the same installation (stacking) -
• Output channel - Default is 39 UHF (606.5 MHz). If the modulators are on the same output channel as another
modulator or FTA channel the TV will not scan the channel in. Place all modulators on available channels between 6 to 12 VHF and 28 to 51 UHF (including adjacent channels - 38, 39, 40, etc.)
Note - if you plan on using channel 52 to 69 be aware of LTE transmissions as they may interfere with each other. We
recommend installing a lter.
• LCN (Logic Channel Number) - default 101. If TV tuner receives two or more LCN’s on the same number, including
FTA channels - the TV will automatically place the LCN on a free range. In Australia this is 350 and up. Suggest to go 101, 102, 103, etc.
Channel Name - default “CHANNEL-1” this is necessary but recommended for clients to be able to identify
channels. For example “APPLE-TV”, “FOXTEL”, “DVD”, etc.
• TS ID (Transport Stream) - Default can vary per product. You will need to adjust the TS ID # on each additional
modulator up one number per modulator. For example if default is “TS ID #1” - leave on “TS ID #1”, place 2nd modulator on “TS ID #2”, 3rd on “TS ID #3”, etc. If the TS ID is the same number the TV tuner will not scan both
channels in.
• Program Number - Default can vary per product. You may need to adjust each additional modulator Program
Number up one number per modulator. For example, if default is “Program Number - 1” - leave on “Program Number
- #1”, place 2nd modulator on “Program Number - #2”, 3rd on “Program Number - #3”, etc. If the Program Number is
the same number the TV tuner will not scan both channels in.
Note - most TVs do not have an issue with this setting but we recommend changing it just in case.
Installing Multiple Encoders in the Same Installation (Stacking)
Please refer to RL-RF380 & RL-RF210 for IR Distribution setup and conguration.
IR Distribution
RL-DM1102M User Guide and Install Manual Page 13
Notes
RL-DM1102M User Guide and Install Manual Page 14
Notes
RL-DM1102M User Guide and Install Manual Page 15
Notes
www.digi-modbyzycast.com
WARRANTY digi-MOD states that the warrant that the customer can rely on is that provided by the manufacturer. In the event of any warranty claim please contact your place of purchase and it will be forwarded it to the manufacturer. The manufacturer will then determine the extent of their liability.
Loading...