Z-Wave Panic Button User Manual

Z- Wa ve® P an ic Bu tt on
User’s
M
anual
I
ntroduction
The Panic Button is a wireless switch designed to control the Panic or Scene status of other associated devices through the Z-Wave controller. After receiving the signals emitted by the Panic Button, the Z-Wave controller can then give commands or operate according to its own settings. Its great compatibility with Z-Wave products makes it suitable for smart home cloud based gateway.
The Panic Button is also a security Z-Wave device and supports the Over The Air (OTA) feature for the product’s firmware upgrade. If you want it to be a security device that use secure/encrypted message to communicate in a Z-Wave network, then a security enabled Z-Wave controller is needed.
Package C
ontents
Pani c Butto n
x 1
User Manual x 1
Command Class Z-Wave® Panic Button Command Class Supported
COMMAND_CLASS_ZWAVEPLUS_INFO_V2, COMMAND_CLASS_SUPERVISION_V1, COMMAND_CLASS_BATTERY_V1, COMMAND_CLASS_WAKE_UP_V2, COMMAND_CLASS_TRANSPORT_SERVICE_V2, COMMAND_CLASS_SECURITY_V1, COMMAND_CLASS_SECURITY_2_V1, COMMAND_CLASS_VERSION_V3, COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4 COMMAND_CLASS_ASSOCIATION_V2, COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1, COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3, COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2, COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1, COMMAND_CLASS_POWERLEVEL_V1, COMMAND_CLASS_NOTIFICATION_V8, COMMAND_CLASS_CONFIGURATION_V1,
Security
COMMAND_CLASS_ASSOCIATION_V2, COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3, COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1, COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2, COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1, COMMAND_CLASS_POWERLEVEL_V1, COMMAND_CLASS_NOTIFICATION_V8, COMMAND_CLASS_CONFIGURATION_V1, COMMAND_CLASS_BATTERY_V1, COMMAND_CLASS_WAKE_UP_V2, COMMAND_CLASS_VERSION_V3, COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
Panic Button D evice Informati on
Basic Device Class: ROUTING_SLAVE Generic Device Class: SENSOR_NOTIFICATION Specific Device Class: NOTIFICATION_SENSOR
Detailed
descrip tion of each
comman d class
COMMAND_CLASS_ZWAVEPLUS_INFO The Z-Wave Plus Info Get Command is used to get additional information of the Z-Wave Plus device in question. COMMAND_CLASS_SUPERVISION The Supervision Command Class allows a sending node to request application-level delivery confirmation from a receiving node. The delivery confirmation includes relevant application-level status information in the confirmation message. The Supervision Command Class MAY be used for solitary commands such as Set and unsolicited Report commands. The Supervision Command Class MUST NOT be used for session-like
command flows such as Get←→Report command exchanges or firmware
update. COMMAND_CLASS_BATTERY_V1 The Battery Command Class is used to request and report battery levels for a given device. COMMAND_CLASS_WAKE_UP_V2 The Wake Up Command Class version 2 enables read back of the Wake Up Interval capabilities in a node. The Z-Wave Panic Button wakes up by wake up timer or presses the physical button once, it will send Wakeup Notification Command to the node ID that requires to be reported and stay awake for 10 seconds, if no WAKE_UP_NO_MORE_INFORMATION command is received. COMMAND_CLASS_TRANSPORT_SERVICE_V2 The Transport Service Command Class supports the transfer of datagrams larger than the Z-Wave frame. COMMAND_CLASS_SECURITY_V1 The Security Command Class create the foundation for secure application communication between nodes in a Z-Wave network. The security layer provides confidentiality, authentication and replay attack robustness through AES-128. COMMAND_CLASS_SECURITY_2_V1 The Security 2 Command Class is a framework for allowing nodes to communicate securely in a Z-Wave network. The Security 2 Command Class
provides backwards compatibility to nodes implementing the Security 0 Command Class. Security 2 Command Class also defines a new encapsulation format, new Security Classes and a new KEX Scheme 1, which together offers a number of advantages over the Security 0 Command Class. Security 2 Command Class is scalable and allows more KEX Schemes, Security Classes and encapsulation formats to be introduced in the future if necessary. COMMAND_CLASS_VERSION_V3 The Version Command Class, version 3 allows supporting nodes to advertise capabilities related to the Version Command Class and optionally provide a detailed list of information regarding implementation on the Z-Wave chip.
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4】 【
COMMAND _CLASS_ASSOC IATION_V2
The Association Command Class is used to manage associations to NodeID destinations. A NodeID destination may be a simple device or the Root Device of a Multi Channel device.
COMMAND _CLASS_MULTI _CHANNEL_ASSOC IATION_V3
The Multi Channel Association Command Class is used to manage associations to Multi Channel End Point destinations as well as to NodeID destinations. COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 The Association Group Information (AGI) Command Class allows a node to advertise the capabilities of each association group supported by a given application resource. Controllers and installer tools SHOULD use AGI information to support controller-assisted button-to-button association and GUI-based drag-and-drop association in a plug-and-play fashion. Centralized gateway-based deployments may create a single association from the lifeline association group to a central management application.
Group
Name
Description
1
"Lifeline"
Lifeline group, association with 5 nodes.
2
Basic set
ON/OFF group, association with 5 nodes.
When the key is press and hold the button more than 1.5 seconds, a BASIC_SET command will sent On(0xFF) or Off(0x00) to the nodes of Grouping 2.The Basic Command Class support Version 2. COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 Manufacturer Specific Command Class, version 2 adds a set of commands to communicate unique identification, e.g. the serial number, of the product. Commands not mentioned here remains unchanged as specified for Manufacturer Specific Command Class, Version 2. COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 The Device Reset Locally Command Class is used to notify central controllers that a Z-Wave device is resetting its network specific parameters. COMMAND_CLASS_POWERLEVEL_V1 The Powerlevel Command Class defines RF transmit power controlling Commands useful when installing or testing a network. The Commands makes it possible for supporting controllers to set/get the RF transmit power level of a node and test specific links between nodes with a specific RF transmit power level. COMMAND_CLASS_NOTIFICATION_V8 The Notification Command Class is used to advertise events or states, such as movement detection, door open/close or system failure. The Notification Command Class supersedes the Alarm Command Class.
Notification Type
Notification events
0x07 (Home Security) 0x00 (Previous event clear)
0x08 (Button detected)
COMMAND_CLASS_CONFIGURATION_V1 The Configuration Command Class allows product specific configuration parameters to be changed. One example could be the default dimming rate of a light dimmer. This class is used for setting certain vendor specific configuration variables.
ID
Name
Size
Range
Default value
Description
1
LED Light up Time
1
1~100, 127 127
1~100:LED light up 1 ~ 100 Seconds. 127:always on
2
Buzzer beep times
1
0, 1~100, 127
127
0 : Disable 1~100: Sound 1~100 beeps (0.5s on, 0.5s off) 127: Continue beep till cancel trigger
Product Overview
LED Indicator
LED Signal
Status
OFF
No Power/paired and ready to be triggered (with battery)
Solid Red
Device had been triggered
Red blink three times at one blink per second
Inclusion successful/Exclusion successful/Parameter successfully set
Red blink two times at one blink per second
Device had been deactivated and back to standby mode
Red blinks at one blink
Low battery
per three seconds
Red blinks for 30 seconds at one blink per two seconds
The device is in unpaired mode and waiting to be inclusion
Solid Red for 5 seconds
The device is in paired mode when insert batteries
Button Function
Function
Operation
Inclusion
Push the button three times in 1.5 seconds. When inclusion successful, the LED will be RED blink three times.
Exclusion
Push the button three times in 1.5 seconds. When exclusion successful, the LED will be RED blink three times. And the LED will be
red blinking for 30 seconds at one blink per two seconds. The device is now waiting to inclusion.
Reset
Push the button three times in 1.5 seconds and hold the third push for 10 seconds till the LED is red blinking. When reset is successful, the device is set to factory default and now waiting to inclusion Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Trigger
Push and hold the button more than 1.5 seconds.
Deactivate
When the device is triggered, push and hold the button more than 6 seconds. The buzzer will mute and the LED will be red blinking two times.
Specification
Z-Wave®
Panic Button
Specification
RF Protocol
Z-Wave Plus (S2)
Power Source
DC 3V, AAA batteries x 2
Z-Wave Frequency
EU:868.42 MHz US:916.00 MHz JP: 922.5 MHz
Data Rate
9.6kbps /40kbps/100kbps
Operation Range
100 feet (About 30M )
LED Indicator
RED
Button
X 1 (Inclus ion/Exclusion/Trigger/Re set)
Waterproof Level
IPX4
Operation Temperature
-10~40
Regulatory Approvals
CE / FCC/TELEC / Z- Wave® Plus
Dimensions (L*W*H)
80 x 80 x 40.5 mm
Regulatory Compliance
CE Caution
Electromagnetic compatibility and Radio spectrum Matters (ERM); Short
Range Devices (SRD); Radio equipment to be used in the 25 MHz to 1,000
MHz frequency range with power levels ranging up to 500 mW; Part 2:
Harmonized EN covering essential requirements under article 3.2 of the
R&TTE Directive.
FCC Caution
This device complies with Part 15 of the FCC rules standard. Operation is
subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including
interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party
responsible for compliance cou ld void the authority to operate equipment.
This device and its antenna must not be c o-located or operating in
conjunction with any other antenna or transmitter. This equipment complies
with FCC radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with minimum distance
20cm between the radiator & your body. This equipment has been tested
and found to comply with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to p rovide reasonable
protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Button
LED Indicator
WEEE Information
For EU (European Union) member users: According to the WEEE (Waste
electrical and electronic equipment) Directive, d o not dispose of this product
as household waste or commercial waste. Waste electrical and electronic
equipment should be a ppropriately collected and recycled as required by
practices established for your country.
For information on recycling of t his product, please contact your local
authorities, your household waste disposal servi ce or the shop where you
purchased the product
Z-Wave Plus
This product can be included and operated in any Z-Wave network with other
Z-Wave certified devices from other manufacturers and/or other applications.
All non-battery operated nodes within the network will act as repeaters
regardless of vendor to increase reliability of the network.
This device must be used in conjunction with a Security Enabled Z-Wave
Controller in order to fully utilize all implemented functions.
This device is a security enabled Z-Wave Plus product that is able to use
encrypted Z-Wave Plus messages to communicate to other s ecurity enabled
Z-Wave Plus products. Note: A "Security Enable Z-Wave Controller" must be
used in order to fully utilize this function.
Security S2
Security S2 is supported with the Authenticated and UnAuthenticated levels
of security. The Authenticated level requires the user to enter the PIN code
or QR code printed on the box. The U nAuthenticated level does not require
the PIN code. Both security levels will encrypt nearly all communication using
AES-128 encryption to ensure reliable and secure communication.
SmartStart
SmartStart enabled products can be added into a Z-Wave network by
scanning the Z-Wave QR Code present on the product with a controller
providing SmartStart inclusion. No further action is required and the
SmartStart product will be added automat ically within 10 minutes of being
switched on in the network vicinity. The pin code is printed on the back of
device along with the QR code. Simply enter the PI N code or scan the Q R
code with a compatible device. Each QR code is unique for every device.
SmartStart uses the latest Security S2 encryption technology for all radio
communication. It is completely backwards compatible with non-SmartStart
systems if your home automation system doesn’t support it yet.
About Pin code or QR code example:
Please save the QR code or PIN code carefully. If both the DSK representation on the product and any DSK provided in the product packaging were to fade, rub off, or be lost, the device would not be able to be added to a Z-Wave network.
Loading...