This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference,
ferring to the enclosed module. The label should use wording such as “Contains
904 RFID/2 LEGIC 13.56MHz proximity R/W modules
Output for TMC PROX & TRAX
Output Assignment for TMC MAX
p/n 904.205.15 - Magstripe output or TTL serial module
p/n 904.206.15 - RS232 or Wiegand or buffered Clock &
Data module.
LEGIC SC2560 based proximity read-write interface for ISO15693 & ISO14443A tags
Transponder types
Interface
Reading range
Visual indication
Power supply
Dimensions
Temperature range
Interface Cable
LEGIC prime (13.56MHz proprietary), advant (ISO15693 and ISO14443A)
Electrical: According to model p/n and pins.
Data format: According to configuration pins.
About 4 cm with ISO cards.
Don’t mount the reader directly on metal surface.
Two LEDs (Red and Green) driven by connecting Yellow and Grey wires to GND.
p/n 904.205.15: 5 Vdc. (+/-10%), 150mA typical.
p/n 904.206.15: 5 to 18 Vdc, 150mA typical.
101 x 44 x 23 mm (outline)
-25° to +60°C.
300 cm, PVC, 10 wires (904.205.15) or 12 wires, no connector (904.206.15).
WARNING: connect first GND blue wire, then other connections, leaving Vdc last one.
Configuration Pins
Output Format ↓
Serial/RS232
Magstripe – Clk&Data
Wiegand
(904.206.15 only)
Brown
TO GND
GreyPink BluRed Green (x)
19200,N,8: TO GND
38400,N,8: OPEN
OPEN TO GND OPEN TO GND
OPEN OPEN TO GND TO GND
904.205.15 904.206.15
Via della Filanda, 22 - 40133 Bologna -
Tel:+39 051 3519311 -
2Color wires - 904.206.15 only
OPEN (RXD)
Data transmission
Readers are preprogrammed for automatic retrieving and
transmission of any of a few common known segments data,
or (if known segments are missing) of the UID code always
present in all cards. UID is output in Magstripe emulation as
binary conversion to a string of 20 decimal figures (10 figures
for each 4Bytes/32bits group). Note: The preprogrammed
logical output, is not proper for the Wiegand output. Proper
logical output format, in general, can be reprogrammed with
the TMC LEGIC configuration utility or CSW2000 program by
LEGIC.
WARNING: Make all the connections before applying the
power supply to the reader. Never connect the configuration
pins (Brown, GreyPink or BluRed) to the Vdc.
The TTL output version only is supplied with a 8-pin
MOLEX connector. It is factory configured for using (as a
magnetic emulation reader) with TMC 914.003.20 HotMAX
boards. Connection to PROX (and TRAX) terminals is also
possible changing the pins order and reducing the
connector as shown in the rightmost table.
Note: to modify the pin connections or change the
connector size, just press a little with a screwdriver into the
corresponding rectangular hole and pull the wire at the
same time.
Then re-insert it in the required position.
Blue
Red
Green
White
Pink
RXD
TXD
serial TTL
Clock Data0 / Clock
Black
Yellow
Gray
Violet
1 Blue GND
2 Red Power 5 Vdc
3 Pink Clock Output
4
5 White Data Output
6
7 Yellow GREEN LED
8 Gray RED LED
GREEN LED
RED LED OFF =
Reserved for FW upgrades – do not connect.
Power 5 (+/-0.5) Vdc
serial TTL
/ Data TXD -
Data1 / Data
and (2) this device must accept any interference. Changes or modifications not expressly approved by the party responsible for compliance could void the
INSTRUCTIONS FOR FCC ID LABELING
Module type: transmitter 90401-15
FCC-ID: SYL90401-15
This intends to inform you how to specify the FCC ID of our transmitter module 90401-15 on your final product. Based on the Public Notice from FCC, the
product into which our transmitter module is installed must display a label re
transmitter module FCC ID: SYL90401-15” or “Contains FCC ID: SYL90401-15”, any similar wording with the same meaning may be used.
user's authority to operate the equipment.
GND
RXD -
OFF
=
OPEN
OPEN
5 Red Power 5Vdc
4 Blue GND
3 White Data Output
2 Pink Clock Output
1
(n.c.)
RS232 (x)
RS232
, ON =
, ON =
1 2 3 4 5 6 7 8
TOGND
TOGND
This device only conforms to
all the standards of the CE
mark if the installation and
user instructions contained in
this document are followed
correctly.
904 RFID2 LEGIC Shortform-ENG-16.doc p.n.19040222