Zooper EC-EX10 Installation Manual

EC-EX10
5. Engineer’s Keypad
An engineer’s keypad can be plugged onto this connector to allow programming and testing of the system.
Eclipse Zone & Output Expander
Installation Instructions
1. Introduction
The EC-EX10 is supplied in a stylish plastic enclosure and is connected to the 4-wire control panel network to provide an additional 10 zones and 10 outputs. A set of connections for a loudspeaker is also provided.
2. PCB Layout & Connections
The figure below shows the PCB layout for the EC-EX10:
1
11
3
2
4 5
6
6. Programmable Outputs
These terminals provide programmable switched -ve driven outputs. OP1 to OP8 are low current 100mA and suitable for driving light load like relays and LED’s. OP9 and OP10 are high current 1Amp and can used for driving heavier loads.
An additional power supply maybe required in order to
supply adequate power to drive the devices connected to the Programmable Outputs.
7. Auxiliary 12V
These terminals provide auxiliary power for powering detection device and device connected to the programmable outputs.
8. Loudspeaker Output
These terminals provide a set of connections for a 16 loudspeaker for generation of exit, entry and alarm tones.
9. Onboard Piezo Sounder
The piezo sounder generates low level alarm, fault and system tones. The engineer can also make the sounder “Beep” the address from “View Zone Status” menu.
10. Address Selector
Each expander must be assigned a different address using the address selector. Move the jumper to the required position 1, 2, 3 or 4.
11. Zone Inputs
These terminals provide the zone inputs for detection devices. Both the zone type and the wiring configuration are programmable by the control panel. Please refer to the control panel installation manual. The power for detection devices should be taken from the auxiliary 12V terminals.
7
3. Installation
7
11
10
1. Network In
These four connections must be connected to the control panel network, or the “Network Out” of another EC-EX10.
2. Lid Tamper
The lid tamper detection switch. The tamper protection can be disabled at the control panel, please refer to the control panel installation manual.
3. Status Indicator
This LED indicates the status of the system. When lit red it indicates an alarm, green indicates it is healthy. The indicator will also flash the expander address when the system is in engineer’s mode.
4. Network Out
These four connections should be used to connect other devices that are down stream from the expander.
P0030-LI-01.00 1
8
9
Please follow the installation sequence below:
1. Remove the screw cap by using a large flat blade screw driver, then undo the cover screw using a suitable pozi-drive screwdriver and remove the cover.
2. Position the expander in the require position and mark the four securing holes in each corner.
3. Drill and plug the holes then secure the expander with suitable fixings.
4. Route the network, zone and output cables into the housing through the cable entries provided.
5. Connect the detection devices to the Zone Inputs and Auxiliary 12V.
6. Connect the network cable to the Network In terminals and Network Out (if you connecting other devices from the expander).
7. If required, connect the switched output loads between the Programmable Outputs and Auxiliary 12V (+).
8. If required, connect a 16 loudspeaker to the Loudspeaker Output terminals.
9. Set the Address Selector to the required position.
10. Apply power to system and confirm the new expander is being recognised by the control panel. See “Confirm Devices” in the control panel installation manual.
11. Test the operation of the zones, outputs and loudspeaker, and then finally replace cover.
4. Network Wiring
Zone & Output Expander
Address = 1
IN OUT
12V
0V
RD
12V
0V
RD
Control Panel
RD
Network
Disconnect +12V
Remote keypads and expanders are all connected to the same network terminals located at the bottom left hand corner of the control panel and may be connected serially (daisy chain), in parallel (star) or any combination of the two.
Network Voltage Drop
When devices are on long cable runs or the current being drawn from the network is high, the voltage at the expander or keypad will drop due to the impedance of the cable. There are several ways to reduce the level of voltage drop in a network:
f Use thicker lower resistance cable. Standard 7/0.2 alarm
cable has a resistance of 8 per 100m
f Double up on the power connections – this will require
using a 6 or 8-core cable rather than a 4-core cable
f Install a power supply to power the device locally
12V Power
Supply
0V
12V
Zone & Output Expander
Address = 2
IN OUT
12V
0V
RD
12V
0V
RD
To additional devices
6. Standards
Safety
Conforms to European Union (EU) Low Voltage Directive (LVD) 2006/95/EC.
EMC
Conforms to European Union (EU) Electro-Magnetic Compatibility (EMC) Directive 2004/108/EC.
Security
Conforms to EN 50131-1 and EN 50131-3 Grade 2, Environmental Class IV.
Installing a Power Supply
When a power supply is installed, the 0V connections on the power supply must be connected through to 0V on the control panel and the +12V connection between the control panel or previous device must be disconnected, see figure above.
5. Specifications
Electrical
Voltage: 10 - 16VDC. Current: 40mA Zone Inputs: 10 fully programmable Outputs: OP1-8: 100mA; OP9-10: 1Amp Loudspeaker: Minimum load of 16 Auxiliary 12V: Protected by 1Amp electronic fuse (PTC)
Environmental
Operating Temp.: -25°C to +55°C (-13°F to +131°F). Storage Temp.: -25°C to +60°C (-13°F to +140°F). Max. Humidity: 95% non-condensing. EMC: Residential, commercial and light
industrial.
Do not throw away the product with the
normal household waste at the end of its life, but hand it in at an official collection point for recycling.
The CE mark indicates that the EC-EX10 complies with the European requirements for safety, health, environment and customer protection.
7. Warranty
Zeta Alarm Systems by GLT Exports Ltd products are carefully designed to provide reliable problem-free operation. Product quality is carefully controlled during all manufacturing processes. The EC-EX10 is covered against defects in material or faulty workmanship for a period of 2 years from the date of purchase. Due to our policy of continuous product improvement, Zeta Alarm Systems by GLT Exports Ltd reserves the right to change specification without prior notice.
As the EC-EX10 is not a complete intruder alarm systems, but only part of it, Zeta Alarm Systems by GLT Exports Ltd does not accept responsibility or liability for any damages whatsoever based on any claim that the unit failed to function correctly.
Technical Support
Email: support@zetaalarmsystems.com
Physical
Dimensions: 136.0mm x 174.0mm x 35.0mm. Packed Weight: 350g.