Zoo Med Micro Clean 304 Filter User Manual

Aquarium mini-filter
Mini-filtre pour aquarium
Kleinfilter für Aquarien
Mini-filtro per acquari
Mini filtro para aquarios
Item# MC-10
SPARES RECHANGES ERSATZTEILE RICAMBI RECAMBIOS
50Hz 60Hz
PMC-12
PMC-14
FIG. 2FIG. 1
FIG. 3
FIG. 4
ENGLISH
SAFETY WARNINGS
Always disconnect all electrical appliances from the power
before placing your hands in the water.
The line cord cannot be replaced or repaired. Should the cord
become damaged the appliance must be discarded.
This unit is intended for indoor use only. This unit must not be used in swimming pools or bathrooms. This appliance has been designed for use in fluids up to 95°F
(35°C.)
For UK only
Check that the voltage shown on the label of the unit
corresponds to the voltage of the mains supply.
Connect the unit only to power supplies with residual current
circuit breaker (RCCD) with sensitivity of 30 mA.
The leads of this unit must be connected as follows: Blue or Black to Neutral or Black-coloured terminal; Brown to Live or Red­coloured terminal. This unit is fitted with a BS1363 13A plug. Should the fuse need to be replaced, a 3A ASTA approved BS1362 must be used. If your socket is not suitable for the plug then plug must be removed and an appropriate one fitted. Warning: Proper care must be taken in discarding a plug which has been removed by cutting the cable.
INSTALLATION
Mount the suction cups on the filter (fig. 1). Choose an appropriate position for good water circulation. Clean the surface from algae etc. and firmly press the filter against it. The water outlet can be extended if desired by adding a length of pipe.
ADJUSTING THE FLOW
Rotate the control valve toward min. or max. indicator (fig.
2) as necessary.
MAINTENANCE
Periodically clean the filter, the rotor and the pump chamber to remove any debris which could block the unit (fig.3-4). It is recommended to replace the filter cartridge after 3 or 4 rinsings or when it appears to be damaged to ensure maximum efficiency. The motor is fully encapsulated and self protected against overheating and needs no particular care. If the filter fails to work, first check the electrical supply, connections, circuit breaker etc. for failures. If these are all right, the pump needs cleaning.
CLEANING
Prior to any work, disconnect all electrical equipment from mains. Remove the filter from the motor housing and pull off the rotor from its location (fig. 3). Wash all components with the help of a non metallic brush. Lime-scale can be removed by leaving the parts immersed in vinegar or lemon juice for few hours. Open the bottom of the filter, take out the sponge and rinse it under luke-warm water (fig. 4).
WARRANTY
This unit has been manufactured according to IEC EN 60 335-2-41 safety standards, and with the highest quality materials and accuracy.
This product is guaranteed against manufactured defect for 12 months from date of purchase. In the unlikely event of a fault, the unit should be returned to Zoo Med within one year of purchase, together with the sales receipt. It is important that the unit should not have been tampered with.
Please note, the guarantee is not valid if the defects are caused by tampering, negligence, misuse or non observing the safety warnings. No responsibility is assumed for indirect damage that may result from the use of this appliance.
Loading...