Model Number Seal Mode Volts Phase Amps HP Hz Lbs Kg
M266/BN266 Single Auto 115 1 10.4 1/2 60 41 19
N266 Single Non 115 1 10.4 1/2 60 41 19
D266/BE266 Single Auto 230 1 5.5 1/2 60 41 19
E266 Single Non 230 1 5.5 1/2 60 41 19 H266 Single Auto 200-208 1 6.2 1/2 60 41 19
I266 Single Non 200-208 1 6.2 1/2 60 41 19
M267/BN267 Single Auto 115 1 10.4 1/2 60 47.5 22
N267 Single Non 115 1 10.4 1/2 60 47.5 22
D267/BE267 Single Auto 230 1 5.5 1/2 60 47.5 22
E267 Single Non 230 1 5.5 1/2 60 47.5 22 H267 Single Auto 200-208 1 6.2 1/2 60 47.5 22
I267 Single Non 200-208 1 6.2 1/2 60 47.5 22
M268/BN268 Single Auto 115 1 10.4 1/2 60 51 23
N268 Single Non 115 1 10.4 1/2 60 51 23
D268/BE268 Single Auto 230 1 5.5 1/2 60 51 23
E268 Single Non 230 1 5.5 1/2 60 51 23 H268 Single Auto 200-208 1 6.2 1/2 60 51 23
I268 Single Non 200-208 1 6.2 1/2 60 51 23
Model 266 features a plastic base. Models 267 and 268 feature a cast iron base. Model 267 is available with a cast iron impeller, which is standard on all 3 phase units. Model 268 includes a 2" NPT female and 3" NPT male discharge. BN and BE models include a variable level pump switch.
Additional cord lengths are available in 15' (5 m), 35' (11 m) and 50' (15 m).