NOTICE TO INSTALLER: Instructions must remain with installation.
Product information presented here re fl ects con di tions at time of publication. Consult factory re gard ing dis crep an cies or in con sis ten cies.
P.O. BOX 16347 • Louisville, KY 40256-0347
3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624
SECTION: 6.10.079
FM1613
0609
Supersedes
0409
visit our web site:
www.zoeller.com
MODELS 580 & 585
BATTERY BACKUP PEDESTAL SUMP PUMP
1. Inspect your pump. Occasionally, products are dam aged during shipment. If the unit or any of the parts are dam aged, contact your dealer before us ing.
2. Read all the installation instructions regarding in stall ing and start up. Retain for future ref er ence.
SEE BELOW FOR LIST OF WARNINGS
1. Testing for Ground. As a safe ty mea sure each elec tri cal outlet should be checked for ground using an Underwriters Laboratory list ed cir cuit ana lyzer, which will indicate if the power, neu tral and ground wires are correctly con nected to your out let. If they are not, call a qualifi ed licensed electrician.
2. For your pro tec tion always dis con nect the pow er supply from its power source before handling the com po nents of your DC back up pump or the pri ma ry pump.
3. Installation and checking of elec tri cal cir cuits and hard ware should be per formed by a qualifi ed, li censed electrician.
4. All elec tri cal and safety codes must be fol lowed in ad di tion to the National Electrical Code and all applicable local codes.
5. It is the owner’s responsibility to check the bat tery
and bat tery connection at least once a month. Bat-
ter ies con tain acid and cau tion must be taken when han dling.
6. Risk of electric shock - These pumps have not been investigated for use in swimming pool areas.
7. According to the state of California (Prop 65), this product contains chemicals known to the state of California to cause cancer and birth defects or other reproductive harm.
P/N 011952
SEE BELOW FOR LIST OF CAUTIONS
1. Make sure there is a properly ground ed 115V re cep tacle avail­ able. Do not use primary pump cir cuit. The location must be within
6' of the control box and battery. The power supply for your DC control system plugs directly into the 115V outlet. DO NOT USE
AN EX TEN SION CORD.
2. Make sure the 115V electrical supply circuit is equipped with fuses or circuit breakers of prop er capacity.
3. DC emergency pumps are de signed for han dling clear water. Do not use in septic tanks to pump ef fl u ent or sew age pits to pump sewage.
4. Repair and service of your DC backup sys tem should be per formed by an authorized service station.
© Copyright 2009 Zoeller Co. All rights reserved.
5. The installation of DC automatic back up pumps re quires the use of a variable level fl oat switch for operation. It is the responsibility of the installing party, to ensure that the teth ered fl oat switch will not hang up on the pump ap pa ra tus or pit pe cu li ari ties and is secured so the pump will turn “on” and “off”. It is recommended that the pit be 18" in diameter or larger to ac com mo date both a pri ma ry and a DC backup pump.
REFER TO WARRANTY ON PAGE 2.
Limited Warranty
Manufacturer warrants, to the purchaser and subsequent owner dur­ing the warranty period, every new product to be free from defects in material and workmanship under normal use and service, when properly used and maintained, for a period of one year from date of purchase by the end user, or 18 months from date of original manu­facture of the product, whichever comes fi rst. Parts that fail within the warranty period, one year from date of purchase by the end user, or 18 months from the date of original manufacture of the product, whichever comes fi rst, that inspections determine to be defective in material or workmanship, will be repaired, replaced or remanufactured at Manufacturer's option, provided however, that by so doing we will not be obligated to replace an entire assembly, the entire mechanism or the complete unit. No allowance will be made for shipping charges, damages, labor or other charges that may occur due to product failure, repair or replacement.
This warranty does not apply to and there shall be no warranty for any material or product that has been disassembled without prior ap­proval of Manufacturer, subjected to misuse, misapplication, neglect, alteration, accident or act of God; that has not been installed, operated or maintained in accordance with Manufacturer's installation instruc­tions; that has been exposed to outside substances including but not limited to the following: sand, gravel, cement, mud, tar, hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents, etc.), or other abrasive or corrosive substances, wash towels or feminine sanitary products,
etc. in all pumping applications. The warranty set out in the paragraph above is in lieu of all other warranties expressed or implied; and we do not authorize any representative or other person to assume for us any other liability in connection with our products.
Contact Manufacturer at, 3649 Cane Run Road, Lou is ville, Ken tucky 40211, Attention: Cus tom er Ser vice De part ment to obtain any need ed repair or re place ment of part(s) or additional in for ma tion pertaining to our warranty.
MANUFACTURER EXPRESSLY DIS CLAIMS LI A BIL I TY FOR SPE­ CIAL, CON SE QUEN TIAL OR IN CI DEN TAL DAM AG ES OR BREACH OF EX PRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED WAR RAN TY OF FIT NESS FOR A PAR TIC U LAR PUR POSE AND OF MER CHANT ABIL I TY SHALL BE LIM IT ED TO THE DU RA TION OF THE EX PRESSED WAR RAN TY.
Some states do not allow limitations on the duration of an implied warranty, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or con se quen tial dam ag es, so the above lim i ta tion or exclusion may not apply to you.
This warranty gives you specifi c legal rights and you may also have other rights which vary from state to state.
Note: The purchase of an Note: Three year limited warranty valid only when a complete system is purchased and used as a backup to a primary dewatering system. A
complete system includes a Model 580 or 585 Aquanot® Pump, Monitor/Charger, and an Aquanot Battery.
Aquanot® Battery from Zoeller Pump Company will extend the Limited Warranty to three years from date of installation.
Carbon Monoxide Detectors
Whether you have an Aquanot® Battery Backup Sump Pump System, or a competitive brand, all batteries give off gaseous by-products when
charging. Some of these by-products can produce a rotten egg odor. Also, some of these by-products can cause a CO detector to falsely activate. In order to help prevent false activation, Zoeller recommends moving the battery as far apart from the CO detector as possible or, if necessary, vent the battery to the exterior. Zoeller provides the previous statements only as guidelines to help prevent false activation of the CO detector. In no way are they meant to supersede the instructions that accompany the detector nor do they supersede advice from the CO detector manufacturer.
If the audible alarm associated with your CO detector is activated, we recommend the following actions:
1) Take immediate action for personal safety as recommended in the CO detector literature.
2) Contact the appropriate agency to determine if the CO is being produced by your furnace, water heater, or any other device which uses natural gas.
3) If you are certain that no CO is being produced, then a charging battery may be producing gaseous by-products which are causing the CO detector to activate. Contact the manufacturer of the CO detector, and ask for recommendations as to what can be done to prevent the alarm activation.
© Copyright 2009 Zoeller Co. All rights reserved.
2
Ten Helpful Hints For Easy Installation
1. Remove all debris from pit before installation.
2. Use a deep cycle battery only. Refer to battery de scrip ­tions on page 6.
3. Be sure the pump is on a fi rm, level surface.
4. Install a serviceable check valve in the discharge line.
6. The battery & charger should be placed on a shelf.
7. Check fl oat On/Off levels per STEP 2 of instructions.
8. Apply grease to the Positive and Negative terminals of the battery to prevent corrosion.
9. Check the battery water level once a month and add distilled water as necessary.
5. Test the unit immediately after installation. Refer to STEP 6.
Do’s And Don’t’s For Installing A Unit
1. DO read all installation material with the pump and charger.
2. DO inspect unit for any visible damage caused by ship­ping. Contact dealer if unit appears to be damaged.
3. DO clean all debris from the pit.
4. DO always disconnect pump from power source before han dling. DO always connect to a separately protected and prop er ly grounded ground fault protected circuit. DO NOT ever cut, splice or damage power cord. DO
Performance Characteristics
10. Obtain model number, date code and in stal la tion in­ struc tions be fore calling factory.
NOT carry or lift pump by its power cord. DO NOT use an extension cord with the Aquanot®. DO NOT lengthen battery/pump leads.
5. DO install union check valve (see step 3) in the dis­ charge line. DO NOT use a dis charge pipe smaller than the rec om mend ed pump discharge sizes.
6. DO test pump immediately after installation to be sure that the system is working properly.
7. DO review all applicable local and national codes and verify that the installation conforms to each of them.
METERS
FEET
8
25
20
6
15
4
10
TOTAL DYNAMIC HEAD
2
5
0
GALLONS LITERS
PUMP PERFORMANCE CURVE
MODEL 580/585
5 101520253035
80
0
604020 100 120
FLOW PER MINUTE
140
580
40 5045
160 180
585
55
200
011922
TOTAL DYNAMIC HEAD/FLOW
PER MINUTE
EFFLUENT AND DEWATERING
MODEL
Feet
Meters Gal. Liters
5 1.5 49 186 10 3.0 36 136 15 4.6 25 95 Shut-off Head:
MODEL
Feet
Meters
5
1.5 10 15 Shut-off Head:
3.0
4.6
Note: Aquanot® II (Model 585) data was de vel oped with the charger supplying DC power to the pump.
© Copyright 2009 Zoeller Co. All rights reserved.
3
585
20 ft.(6.1m)
580
Liters
Gal.
44 167 31
117
13
17 ft.(5.2m)
49
Loading...