
AUTOMATIC
SUBMERSIBLE UTILITY
PUMP
Zoeller® is a registered trademark of
Zoeller Co. All Rights Reserved.
MODEL #1043-0006
Español p. 9
ATTACH YOUR RECEIPT HERE
Serial Number
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 1-800-584-8089, 7:30 a.m. - 5:00 p.m., EST, Monday - Friday.
Purchase Date
SW1177 A
1

PACKAGE CONTENTS
DESCRIPTION QUANTITY
Pump 1
Adapter 1
PERFORMANCE
ITEM
NUMBER
1043-0006 1/3 3.0 2100 1800 1320 720
SAFETY INFORMATION
Please read and understand this entire manual before attempting to assemble, operate, or install
the product.
• NOTE: Pumps with the “UL” Mark and pumps with the “US” mark are tested to UL Standard
UL778. CSA certied pumps are certied to CSA Standard C22.2 No. 108. (CUS.)
DANGER
• FIRE/EXPLOSION HAZARD.
Pump only clear water. Do not pump ammable or explosive uids such as gasoline, fuel oil,
kerosene, etc. Do not use in a ammable and/or explosive atmosphere. Failure to follow these
warnings could result in death or serious injury and/or property damage.
• RISK OF ELECTRIC SHOCK.
These pumps have not been investigated for use in swimming pool areas.
• RISK OF ELECTRIC SHOCK.
Always disconnect power source before attempting to install, service, or maintain the pump.
Never handle a pump with wet hands or when standing on wet or damp surface or in water. Fatal
electrical shock could occur.
HP AMPS
GALLONS PER HOUR AT DISCHARGE HEIGHT
ABOVE PUMPING LEVEL
0 FT. 5 FT. 10 FT. 15 FT.
2

WARNING
• ELECTRICAL SHOCK ALERT.
Before installing this product, have the electrical circuit checked by an electrician to ensure proper
grounding. All electrical installations must conform to the National Electric Code and all local
codes.
• ELECTRICAL SHOCK ALERT.
Connect this product to a properly-grounded 115 volt circuit equipped with a Ground Fault Circuit
Interrupter (GFCI) device.
• ELECTRICAL SHOCK ALERT.
Do not handle pump or pump motor with wet hands or when standing on a wet or damp surface or
in water.
• ELECTRICAL SHOCK ALERT.
These pumps are supplied with a 3-prong grounded plug to help protect you against the possibility
of electrical shock. DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE GROUND PIN.
• ELECTRICAL SHOCK ALERT.
BE CERTAIN the pump power source is disconnected before installing or servicing pump.
• ELECTRICAL SHOCK ALERT.
Protect electrical cord from sharp objects, hot surfaces, oil and chemicals. Avoid kinking the cord.
Replace or repair damaged or worn cords immediately.
• CHEMICAL ALERT.
This product contains chemicals known to the state of California to cause cancer and birth defects
or other reproductive harm.
• PERSONAL INJURY ALERT.
Provide a means of pressure relief if the pump discharge can be shut off or obstructed. Pumps
operating with a closed discharge can create hot liquid, which can cause burns.
• PERSONAL INJURY ALERT.
This pump is equipped with an automatic thermal overload and can restart without warning.
CAUTION
• PERSONAL INJURY OR PRODUCT DAMAGE MAY RESULT.
Check to be sure your power source is capable of handling the voltage requirements of the motor,
as indicated on the pump name plate.
• PRODUCT DAMAGE MAY RESULT.
These pumps are not designed or intended to be used to handle sewage or efuent.
• PRODUCT DAMAGE MAY RESULT.
This pump has been evaluated for use with WATER only.
• PRODUCT DAMAGE MAY RESULT.
Maximum continuous operating water temperature for standard model pumps must not exceed
104°F (40°C).
• PRODUCT DAMAGE MAY RESULT.
Not designed for 24/7 operation. Design life is 4500 accumulated hours.
3