DATA1
DATA0
GND
+12V
LED
BEEP
IWD1
+12V
BEEP
GLED
RLED
IWD0
GND
WD 0
WD 1
DATA0
GND
DATA1
Access Control
IWD1
+12V
BEEP
GLED
RLED
IWD0
GND
WD 0
WD 1
1 2 3 4
ON
KE
1 2 3 4
ON
KE
6.Wiegand Output
7.Wiegand Input
8.Other Functions:
9. Communication
10.Cautions:
!
Warning: No operating with power on!
1 2 3
ON
4
Port 4 is to set the state of terminal
ON
The device supports standard Wiegand 26 output, as a
reader device it has a very good compatibility.
extender in long distance or interference environment).
(2) To keep the stability of Wiegand signal, connect the device and the Access Control or reader in same ‘GND’ in any case.
(1) Please keep the distance between the device and Access Control or reader less than 90 meters(Please use Wiegand signal
Reset button
(1) Manual Reset:
other restart it.abnormality, you can use ‘Reset’ function to
Front
Bottom
with than 2mm).a sharp tool(the tip diameter less
Remove the black rubber cap, then stick the Reset button hole
/
*
-
7
8
9
Num
Lock
+
6
5
4
1
2
3
0
.
Enter
Ins
Del
End
PgDn
Home
PgUp
Bottom
Keyboard
Figure(8-2)
Connector
(2)External USB Keyboard (Refer to your own keyboard):
The device supports external keyboard to offer more flexible
Figure(8-1)
Connect to Access Control
Connect to Keyboard
If the device does not work properly because of misoperation or
convenient to enroll users, remove users, recovery factory
settings, set the keyboard password and so on. The operation
operations. The keyboard need to purchase separately. It’s
please refer to the user manual.
485A
485B
485A 485B
RS485 BUS
(3)Recovery Factory Settings:
IP address, RS485 address, etc. More information please refers to the user manual.
Back
485A 485B 485A 485B
RS485 Converter
Press the tamper switch three times after the alarm being triggered 30 seconds but no more than 60 seconds.
You can use the tamper switch ( As figure (8-3)) factory setting, such as device number, system password,to recovery
Tamper Switch
Figure (8-3) Figure (9-1)
Notes: The user data won’t be cleared.
Terminal PC Serial Ports
485A RS485 +
485B RS485 -
There’re two modes that the PC software communicate and exchange information
with the device: RS485 and TCP/IP, they all support remote control.
(1) RS485 Mode:
Please use specified RS485 wire, RS485 active converter and bus-type wiring.
(I) To prevent the interference, the last device in the RS485 bus connect a 120 Euro resistor. That is turning the switch ‘4’
(terminal resistor switch) to ‘ON’.
(II) The RS485 device No. is shown in PC software. You can change it as follows. (The default switch state is‘OFF’ ) .
Machine No.
No.1
No.2
No.3
No.4
No.5
No.6
No.7
Switch State
Port 1
Port 2
Port 3
'ON'
'ON'
'ON'
The printing number is the device
port number. Port 1, 2, 3 is to set
RS485 address (device number).
No.3 machine’s slide switch
(2) TCP/IP Mode:
(I) Crossover cable: The device and PC directly. As fconnected igure (9-2).
(II) Straight cable: The device and PC connected to LAN/WAN through switch/Lanswitch. As figure (9-3).
IP Address: 192.168.1.201
Subnet Mask: 255.255.255.0
IP Address: 192.168.1.124
Subnet Mask: 255.255.255.0
Switch/Lanswitch
PC
…
Figure (9-2)
Figure (9-3)
PC
(2)We recommend the 3A/12V DC Power supply. Please contact our technical staff for details.
(5)Please connect the ‘GND’ before all the other wiring especially under the environment with much electrostatic.
( )3 Please read carefully the terminal description and wiring by rule strictly. Any damage caused by improper
(4)Keep the exposed part of wire less than 5mm, to avoid unexpected connection.
(6)Do not change the cable type because of long distance between the power and the device. Pay attention to the distance
voltage decay when the power cableyou choose .
(1)Power cable is connected after all the other wiring. If the device is working abnormally, please shut down the power
first, then make the necessary check . Kindly reminds you that any hot-line work may damage the device, and it
operations will not under warranty.
is not included in the warranty.
The symbol ‘ ‘ means turning the switch to ‘ON’ position.
resistor.
The device has the function of Wiegand signal input. It supports
to connect with an independent reader. They are installed each
side of the door, to control the lock and access together.
Enlargement of slide switch