1.1 INTRODUCTION
First of all, thank you for purchasing S1M series redundant power supply.
The S1M series is a N+1 hot-swappable / hot-pluggable redundant power supply. It consists of,
The total output is up to your power’s requirements, you can figure out the total Power’s consumption and check over the specification, the you can find out the correct configuration.
It delivers full safety redundant (hot-swappable) function and provides the hot-pluggable feature. In other words, it can offer a more reliable and safer, easy install / maintain operation in the power energy supply to your system.
Its major function is to deliver the full power and the mean time these power modules can mutually backup once one of the power modules is defective.
It provides a warning subsystem, include LED display, buzzer alarm, TTL signal etc., at the same time, it also indicates the status of the power system.
When all the power modules are at normal condition, it balances the load share and results the power system increase reliability.
To really discover the power and ease in using the product, we recommend that you read through this manual carefully.
1.2 PACKING
Your S1M package should consist of the followings:
(A) S1M series x 1 (B) Accessory pack x 1 (C) Product Manual x 1
1.3 MODEL DESINGATION
Model number identification
X X Y Z X – X XXX X X X 1 2 3 4 5 6 7 8 9 10
1st --- Category
X --- blank AC input ( AC – DC )
D -48Vdc input B -24Vdc input
2nd --- Serial ID
X --- R redundant 1 + 1
M redundant N + 1
3rd --- for # U use
Y --- 1 for 1U use
2 for 2U use
4th --- PM or Customer specify
5th --- # of power module in N+1 system
X --- 1 single
2 1+1 power system 3 2+1 power system 4 3+1 power system
6th --- # of the channel
X --- 2 5V, 12V ( Disk Array )
4 5V, 12V, -5V, -12V ( AT ) 5 5V, 12V, 3.3V, 5Vsb, -12V ( ATX / EPS ) 6 5V, 12V, 3.3V, 5Vsb, -5V, -12V ( ATX / EPS )
7th --- # of total wattages
XXX --- 460 AXX --- 10XX BXX --- 11XX CXX --- 12XX
………
8th --- attribute
X --- P w/ PFC
F w/ EMI filter
9th --- chassis type
X --- H horizontal type
V vertical type M horizontal + vertical type
10th --- Use FAN type
X --- 3 use 3.8CM type
4 use 4CM type 6 use 6CM type 8 use 8CM type
1.4 FEATURES
S1M
N+1, Hot-swap, Hot-plug, AC input min redundant power system
l Low profile power module for building to the requirement l N+1 power system design l Current sharing design l Remote sensing design l 5 channels ( 5/12/-12/3.3/5Vsb ) 350W / 460W / 500W power module outputs l Active power factor correction (PFC) built-in l Universal AC power input l Warning methods---LED, buzzer. TTL signal l UL, UL+C, TUV, CB approved l Meet FCC class B, CISPR 22 class B l Truly redundant feature design l Debounce power disturbance keep from shut-down / reset l Isolated fence in power housing meets the safety regulation l Double protection on OCP & OVP l I2C function (optional)
1.5 DRAWING
1.6 SPECIFICATIONS
INPUT CHARACTERISTICS: S1M-6460P
l VOLTAGE: 90~264VAC FULL RANGE l FREQUENCY:47~63HZ l INPUT CURRENT: 4A ( RMS ) FOR 230VAC
8A ( RMS ) FOR 115VAC
l INRUSH CURRENT : 60 A MAX.FOR 115 VAC PER MODULE
80 A MAX. FOR 230 VAC PER MODULE
OUTPUT CHARACTERISTICS:
OUTPUT
VOLTAGE
OUTPUT CURRENT REGULATION OUTPUT
RIPPLE & NOISE
MIN. [A] MAX. [A] LOAD LINE
+5V 1 32
+12V 2 32 ±
-12V 0 1
±5%
+3.3V 1 30
+5VSB 0.1 2.0
±
±
±
5%
5%
5%
5%
±
±
±
±
±
1%
1%
1%
1%
1%
REMARKS: 1.TOTAL CURRENT OF +5V AND +3.3V NOT EXCEED 50A
2.TOTAL OUTPUT POWER NOT EXCEED 440W
SPECIFICATION:
MAX. [P-P]
70mV
120mV
120mV
70mV
70mV
l TEMPERATURE RANGE: OPERATING 0 --- 40,STORAGE -20 --- 70 l HOLD UP TIME: 1.6 ms MINIMUM AT FULL LOAD & 90VAC INPUT VOLTAGE l DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 MINUTE
INPUT TO FRAME GROUND 1500 VAC FOR 1 MINUTE
l EFFICIENCY: 67% TYPICAL, AT FULL LOAD l POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms l OVER LOAD PROTECTION: 110~160% MAX
. OVER VOLTAGE PROTECTION: +5V à 5.7V ~ 6.5V, +3.3V à3.9V~4.7V,+12V à 13.3V ~ 14.3V . OVER CURRENT PROTECTION
l EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B l SAFETY: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950 l REMOTE ON / OFF CONTROL l FAULTY ALARM METHODS:LED, BUZZER, TTL SIGNAL l MEET IEC-1000-3-2 CLASS D ( ACTIVE PFC) l HOT-SWAPPABLE/HOT PLUGGABLE REDUNDANCY FUNCTION l REMOTE SENSING DESIGN l ISOLATION:BUILT-IN THE POWER MODULE l COOLING: TWO 40x40x28mm DC FANS l AC INLET IN EACH MODULE l DIMENSION:247.9x106x40(D*W*H)mm