First of all, thank you for purchasing MyWx series redundant power supply.
The MyWx series is a N+1 hot-swappable / hot-pluggable redundant power supply. It
consists of,
The total output is up to your power’s requirements, you can figure out the total
Power’s consumption and check over the specification, the you can find out the
correct configuration.
It delivers full safety redundant (hot-swappable) function and provides the
hot-pluggable feature. In other words, it can offer a more reliable and safer, easy
install / maintain operation in the power energy supply to your system.
Its major function is to deliver the full power and the mean time these power modules
can mutually backup once one of the power modules is defective.
It provides a warning subsystem, include LED display, buzzer alarm, TTL signal etc.,
at the same time, it also indicates the status of the power system.
When all the power modules are at normal condition, it balances the load share and
results the power system increase reliability.
To really discover the power and ease in using the product, we recommend that
you read through this manual carefully.
1.2 PACKING
Your MyWx package should consist of the followings:
(A) MyWx series x 1
(B) Accessory pack x 1
(C) Product Manual x 1
1.3 MODEL DESINGATION
Model number identification
X X Y Z X – X XXX X X X
1 2 3 4 5 6 7 8 9 10
1st --- Category
X --- blank AC input ( AC – DC )
D -48Vdc input
B -24Vdc input
2nd --- Serial ID
X --- R redundant 1 + 1
M redundant N + 1
3rd --- for # U use
Y --- 1 for 1U use
2 for 2U use
4th --- PM or Customer specify
5th --- # of power module in N+1 system
X --- 1 single
2 1+1 power system
3 2+1 power system
4 3+1 power system
MyWx
N+1,Hot-swap, Hot-plug, AC input mini redundant power system
l Low profile power module for building to the requirement
l N+1 power system design
l Current sharing design
l Remote sensing design
l 5 channels ( 5/12/-12/3.3/5Vsb ) 600W power module outputs
l 6 channels ( 5/12/-5/-12/3.3/5Vsb ) 500W/550W/950W/1350W/1800W power
module outputs
l Active power factor correction (PFC) built-in
l Universal AC power input
l Warning methods---LED, buzzer. TTL signal
l UL, UL+C, TUV, CB approved
l Meet FCC class B, CISPR 22 class B
l Truly redundant feature design
l Debounce power disturbance keep from shut-down / reset
l Isolated fence in power housing meets the safety regulation
l Double protection on OCP & OVP
l I2C function (optional)
1.5 DRAWING
1.6 SPECIFICATIONS
INPUT CHARACTERISTICS: M1W-6500P
l VOLTAGE: 100V ~ 240VAC (WITH ± 10% TOLERANCE)
l FREQUENCY: 47Hz ~ 63Hz
l INPUT CURRENT: 8.0-4.0A MAX AT ANY LOW/HIGH INPUT VOLTAGE
l INRUSH CURRENT: 60/100A @ 115/230VAC (25℃)
l POWER FACTOR CORRECTION: 95% @ 110V, FULL LOAD
OUTPUT CHARACTERISTICS:
OUTPUT
OUTPUT CURRENT REGULATION OUTPUT
VOLTAGE
MIN. [A] MAX. [A] LOAD LINE
±
5%
6%
5V 3.5 30 ±
12V 2.0 32
-5V 0.05 0.7 +5%, -10%
-12V 0.05 0.7 +5%, -10%
3.3V 1.0 24
±
5%
+5VSB 0.1 2.0 +5%, -6%
REMARKS:
1. THE OUTPUT POWER OF 5V & 3.3V MAX: 40A
2. TOTAL OUTPUT MAX: 500W
SPECIFICATION:
l TEMPERATURE RANGE: OPERATING: 0℃ --- 40℃
50mV
±
50mV
±
50mV
±
50mV
±
50mV
±
50mV
±
RIPPLE & NOISE
MAX. [P-P]
70mV
120mV
120mV
120mV
70mV
70mV
STORAGE: -20℃ --- 80℃
l HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
l DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 SECOND
INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND
l EFFICIENCY: 65% TYPICAL AT 115VAC FULL LOAD
l POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
l OVER POWER PROTECTION: 110% ~ 180%
OVER VOLTAGE PROTECTION: +5V à 5.7V ~ 6.5V, 3.3V à 3.9V ~ 4.7V
+12V à 13.3V ~ 14.3V
OVER CURRENT PROTECTION: 110% ~ 180%
l SHORT CIRCUIT PROTECTION: +5V, -5V, +12V, -12V, +3.3V
l EMI NOISE FILTER: FCC CLASS A, CISPR22 CLASS A
l SAFETY: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950
l REMOTE ON / OFF CONTROL
THE UNIT SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE /
ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STANDBY),
AS LOGIC LEVEL IS LOW, OUTPUTS VOLTAGE WERE ENABLE,
AS LOGIC LEVEL IS HIGH, OUTPUTS VOLTAGE WERE DISABLE.
l 3.3V / 5V REMOTE SENSING
l COOLING: ONE 38mm DC FAN
l DIMENSION: 265.3 (D) x 98.4 (W) x 40 (H) mm
INPUT CHARACTERISTICS: M1W3-6500P
l VOLTAGE: 100V ~ 240VAC
l FREQUENCY: 47Hz ~ 63Hz
l INPUT CURRENT: 20-10A MAX AT ANY LOW/HIGH INPUT VOLTAGE
l INRUSH CURRENT: 60/100A @ 115/230VAC (25℃)
l POWER FACTOR CORRECTION: 95% @ 110V, FULL LOAD
OUTPUT CHARACTERISTICS:
OUTPUT
VOLTAGE
OUTPUT CURRENT REGULATION OUTPUT
MIN. [A] MAX. [A] LOAD LINE
RIPPLE & NOISE
MAX. [P-P]
5V 3.5 30 ± 5% ± 50mV 70mV
12V 2.0 32 ± 6% ± 50mV 120mV
-5V 0.05 0.7 +5%, -10% ± 50mV 120mV
-12V 0.1 0.7 +5%, -10% ± 50mV 120mV
3.3V 1.0 24 ± 5% ± 50mV 70mV
+5VSB 0.1 2.0 +5%, -6% ± 50mV 70mV
REMARKS:
1. THE OUTPUT POWER OF 5V & 3.3V MAX: 40A
2. EACH POWER MODULE OUTPUT MAX: 500W
3. TOTAL OUTPUT POWER MAX: 500W
4. 2 MODULE AND PLUS 1 DUMMY
SPECIFICATION:
l TEMPERATURE RANGE: OPERATING: 0℃ --- 40℃
STORAGE: -20℃ --- 80℃
l HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
l DIELECTRIC WITHSTAND: INPUT / OUTPUT 3000 VAC FOR 1 SECOND
INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND
l EFFICIENCY: 67% TYPICAL AT 115VAC FULL LOAD
l POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
l OVER POWER PROTECTION: 110% ~ 180%
OVER VOLTAGE PROTECTION: +5V à 5.7V ~ 6.5V, 3.3V à 3.9V ~ 4.7V
+12V à 13.3V ~ 14.3V
OVER CURRENT PROTECTION: 110% ~ 180%
l SHORT CIRCUIT PROTECTION: +5V, -5V, +12V, -12V, +3.3V
l EMI NOISE FILTER: FCC CLASS A, CISPR22 CLASS A
l SAFETY: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950
l REMOTE ON / OFF CONTROL
THE UNIT SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE /
ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STANDBY),
AS LOGIC LEVEL IS LOW, OUTPUTS VOLTAGE WERE ENABLE,
AS LOGIC LEVEL IS HIGH, OUTPUTS VOLTAGE WERE DISABL
l 3.3V REMOTE SENSING
l DIMENSION: 330 (D) x 383 (W) x 43 (H) mm
INPUT CHARACTERISTICS: M1W3-6950P
l VOLTAGE: 100V ~ 240VAC
l FREQUENCY: 47Hz ~ 63Hz
l INPUT CURRENT: 20-10A MAX AT ANY LOW/HIGH INPUT VOLTAGE
l INRUSH CURRENT: 60/100A @ 115/230VAC (25℃)
l POWER FACTOR CORRECTION: 95% @ 110V, FULL LOAD
OUTPUT CHARACTERISTICS:
OUTPUT
VOLTAGE
OUTPUT CURRENT REGULATION OUTPUT
MIN. [A] MAX. [A] LOAD LINE
RIPPLE & NOISE
MAX. [P-P]
5V 6.0 56 ± 5% ± 50mV 70mV
12V 6.0 60 ± 6% ± 50mV 120mV
-5V 0.2 1.2 +5%, -10% ± 50mV 120mV
-12V 0.2 1.2 +5%, -10% ± 50mV 120mV
3.3V 3.5 44 ± 5% ± 50mV 70mV
+5VSB 0.4 3.5 +5%, -6% ± 50mV 70mV
REMARKS:
5. THE OUTPUT POWER MODULE OF 5V & 3.3V MAX: 40A
2. EACH POWER MODULE OUTPUT MAX: 500W
3. TOTAL OUTPUT POWER MAX: 950W
SPECIFICATION:
l TEMPERATURE RANGE: OPERATING: 0℃ --- 40℃
STORAGE: -20℃ --- 80℃
l HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
l DIELECTRIC WITHSTAND: INPUT / OUTPUT 3000 VAC FOR 1 SECOND
INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND
l EFFICIENCY: 67% TYPICAL AT 115VAC FULL LOAD
l POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
l OVER POWER PROTECTION: 110% ~ 180%
OVER VOLTAGE PROTECTION: +5V à 5.7V ~ 6.5V, 3.3V à 3.9V ~ 4.7V
+12V à 13.3V ~ 14.3V
OVER CURRENT PROTECTION: 110% ~ 180%
l SHORT CIRCUIT PROTECTION: +5V, -5V, +12V, -12V, +3.3V
l EMI NOISE FILTER: FCC CLASS A, CISPR22 CLASS A
l SAFETY: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950
l REMOTE ON / OFF CONTROL
THE UNIT SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE /
ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STANDBY),
AS LOGIC LEVEL IS LOW, OUTPUTS VOLTAGE WERE ENABLE,
AS LOGIC LEVEL IS HIGH, OUTPUTS VOLTAGE WERE DISABL
l 3.3V REMOTE SENSING
l DIMENSION: 330 (D) x 383 (W) x 43 (H) mm
INPUT CHARACTERISTICS: M1W3-6D50P
l VOLTAGE: 100V ~ 240VAC
l FREQUENCY: 47Hz ~ 63Hz
l INPUT CURRENT: 20-10A MAX AT ANY LOW/HIGH INPUT VOLTAGE
l INRUSH CURRENT: 60/100A @ 115/230VAC (25℃)
l POWER FACTOR CORRECTION: 95% @ 110V, FULL LOAD
OUTPUT CHARACTERISTICS:
OUTPUT
VOLTAGE
OUTPUT CURRENT REGULATION OUTPUT
MIN. [A] MAX. [A] LOAD LINE
RIPPLE & NOISE
MAX. [P-P]
5V 6.0 84.5 ± 5% ± 50mV 70mV
12V 6.0 90 ± 6% ± 50mV 120mV
-5V 0.2 1.2 +5%, -10% ± 50mV 120mV
-12V 0.2 1.2 +5%, -10% ± 50mV 120mV
3.3V 3.5 67.5 ± 5% ± 50mV 70mV
+5VSB 0.4 3.5 +5%, -6% ± 50mV 70mV
REMARKS:
6. THE OUTPUT POWER MODULE OF 5V & 3.3V MAX: 40A
2. EACH POWER MODULE OUTPUT MAX: 500W
3. TOTAL OUTPUT POWER MAX: 1350W
SPECIFICATION:
l TEMPERATURE RANGE: OPERATING: 0℃ --- 40℃
STORAGE: -20℃ --- 80℃
l HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
l DIELECTRIC WITHSTAND: INPUT / OUTPUT 3000 VAC FOR 1 SECOND
INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND
l EFFICIENCY: 67% TYPICAL AT 115VAC FULL LOAD
l POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
l OVER POWER PROTECTION: 110% ~ 180%
OVER VOLTAGE PROTECTION: +5V à 5.7V ~ 6.5V, 3.3V à 3.9V ~ 4.7V
+12V à 13.3V ~ 14.3V
OVER CURRENT PROTECTION: 110% ~ 180%
l SHORT CIRCUIT PROTECTION: +5V, -5V, +12V, -12V, +3.3V
l EMI NOISE FILTER: FCC CLASS A, CISPR22 CLASS A
l SAFETY: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950
l REMOTE ON / OFF CONTROL
THE UNIT SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE /
ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STANDBY),
AS LOGIC LEVEL IS LOW, OUTPUTS VOLTAGE WERE ENABLE,
AS LOGIC LEVEL IS HIGH, OUTPUTS VOLTAGE WERE DISABL
l 3.3V REMOTE SENSING
l DIMENSION: 330 (D) x 383 (W) x 43 (H) mm