User Guide

Tap Operation..................

(Pages 3-5)

LCD Screen & Menu .......

(Pages 6-19)

Maintenance....................

(Pages 20-23)

Contact & Details............

(Page

24)

Date of Installation.............

/.........

/.........

ARC CUBE

Affix Model Number Label

Here 802698

802698 - G4 User Guide - 09.16 - v2.02

Page 1 of 24

NOTES

Page 2 of 24

802698 - G4 User Guide - 09.16 - v2.02

Tap operation - Chilled Sparkling

Turning the rotary control allows the dispensing of either Chilled Sparkling or Chilled water. For your convenience, the rotary control is spring loaded, so when released, will return automatically to the OFF position

To dispense Sparkling water: (Model CSHA)

Turn the rotary control forward as shown

Rotate for Sparkling water

Tap operation - Chilled water

To dispense Chilled water: (Model CHA)

Turn the rotary control in reverse as shown

Rotate for Chilled water

802698 - G4 User Guide - 09.16 - v2.02

Page 3 of 24

Tap operation - Boiling water

To dispense Boiling water: with the safety ON.

Tapping the illuminated RED safety button twice, with one finger, will cause the safety red light to flash for a few seconds. While flashing, turn the rotary control (as shown) to dispense boiling water.

(See section G for safety settings)

Rotate for Boiling water

Safety

To dispense Boiling water: with the safety OFF.

When the RED safety light is OFF, turn the rotary control (as shown) to dispense boiling water.

Tap operation - Mixer

The Mixer tap lever is operated as a conventional ‘Flick Mixer’. The hot side is marked with a red stripe and the cold side with a blue stripe, for dispensing cold to warm water.

Lifting the handle up will decrease the flow rate and lowering the handle will increase the flow rate. Lift the handle all the way up to turn the tap off.

When the handle is moved towards the blue mark, the temperature is decreased and when moved towards the red mark, the temperature is increased. The final temperature will be dependant on the temperature of the incoming cold water.

The spout may be swivelled, left or right, through 170° for convenience.

Vent

Boiling models

Page 4 of 24

802698 - G4 User Guide - 09.16 - v2.02

Filter Warning and Reset

Temperature Warning Light:

The warning light will flash slowly for 1 sec On and 3 secs OFF whenever the water is not at the temperature set point. The tap may be operated, but the water may not be at the desired temperature . The slow flashing light will turn off once the water reaches the set point. The set point temperature is user adjustable (See section G).

Filter Warning Light:

As a reminder that the filter requires changing, the warning light will flash quickly every 10 secs. (See section on filter maintenance.)

Filter Reset:

The warning light will need to be reset after the filter has been changed. (See section C)

Fault Warning Lights:

If there is a fault with the system, both the safety light and the warning light will flash for 1/2 sec ON and 1/2 sec OFF until the fault is rectified.

(See section B) or call an authorised service man.

Warning light

Safety light

Sleep mode (Boiling models)

In SLEEP MODE the unit will Go to “Sleep” after 2 hrs of inactivity, after which, the home screen status window will show “Sleep Mode”.

The sleep mode may be activated from the settings menu. (See section G).

To wake from sleep mode, first tap the safety twice and then turn the rotary control.

802698 - G4 User Guide - 09.16 - v2.02

Page 5 of 24

3LCD Screen

The Zip HydroTap G4 Celsius introduces a ‘TOUCH’ screen for easy setup and operation adjustment.

Safety lock Icon

Sleep Mode Icon

Energy Mode Icon

BHA window

Set boiling water temperature

Filter usage

**Status window

CHA window

Set chilled water temp.

Date and Time

CSHA window

Other possible messages in status window:

Status**

Information

Notes

System Fault

Product has one or more system

Refer to section B

 

faults

 

Change Filter

External/Internal filter needs to be

Refer to section C

 

replaced

 

NOTE: As an energy saving feature, the home screen will turn OFF After 5 minutes of non use. Touching the darkened LCD panel will reactivate the home screen.

Page 6 of 24

802698 - G4 User Guide - 09.16 - v2.02

3LCD Screen Menu

Main Menu

 

Sub Menu

 

Sub Menu Options

Section

 

 

 

 

 

 

 

 

Language

English

 

 

 

A

German

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Product Info

Product serial no.

B

 

 

System Faults

Information

Lists

 

 

 

Event Log

 

 

 

 

 

 

 

 

 

 

 

 

 

Filter Flush

Reset options

C

Installation

Filter Reset

Calibration options

 

 

 

 

 

 

 

 

Service

 

Password protected

 

 

 

D

 

 

 

 

 

 

 

Security

Enable Password

Set Password

E

Change Password

 

 

 

 

 

 

 

 

 

 

Communication

Remote Monitor

Wifi

Options

F

Remote Control

Wifi

Options

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12hr/24hr Mode

 

 

Date/Time

Hot/Cold Setpoint

 

 

Temperature

Filter Life (Litres)

 

Settings

Filter

Filter Life (Months)

G

Energy Modes

Sleep Mode Options

 

 

 

Safety

Safety Lock

 

 

Dispense Times

Hot/Cold

 

 

 

 

 

Dispensing

 

802698 - G4 User Guide - 09.16 - v2.02

Page 7 of 24

Zip MT3787Z1-91295, MT2787Z2-91295, MT2786Z2, MT2786Z3, MT2787Z1 User Manual

LCD Screen operation - Section A A Set Language

1. Press [MENU] for main menu.

2. Press [Language] button.

3. Select the preferred language

4. Press [<=] button for the previous menu

LCD Screen operation - Section B B System Information

In this section, you can find your product serial number , check system fault messages or view the event logs of your product.

1. Press the [MENU] button for main menu.

2. Press the [Info] button to view the product serial number and other key information

1. Press [Product Info] to view the product serial no.

2. Press [<=] button for the previous menu or press [Home] button to return to the home screen.

1. Press [System Faults] to check the fault information;

2. Press [<=] button for the previous menu or press

[Home] button to return to the home screen.

Press [Filtert Log] to view the system’s filter log.

1. Press [<=] button for the previous menu or press

[Home] button to return to the home screen.

Page 8 of 24

802698 - G4 User Guide - 09.16 - v2.02

Loading...
+ 16 hidden pages