Zip Hydroboil 303552, Hydroboil 310552, Hydroboil 307552, Hydroboil 315552, Hydroboil 305552 Installation Instructions & User Manual

...
1
Installation instructions & user manual
804545UK V2.03 Aug 2018 - Zip Hydroboil
Technical support
Tel: 0345 6 005 005 Email: service@zipindustries.co.uk w ww.zipwater.co.uk
Installation instructions & user manual
Zip Hydroboil
On wall boiling water.
Model number:
301552, 303552, 305552, 307552, 310552, 315552, 325552, 340552
02
Installation instructions & user manual
804545UK V2.03 Aug 2018 - Zip Hydroboil
Technical support
Tel: 0345 6 005 005 Email: service@zipindustries.co.uk w ww.zipwater.co.uk
Table of contents
Intended Use ................................................................................................................................ 2
Warnings and precautions ........................................................................................................... 3
Before installation ......................................................................................................................... 4
Technical specification ................................................................................................................. 5
Installation instructions
Before you begin ............................................................................................................... 6
Step 1 - Position the Hydroboil
Positioning ......................................................................................................................... 6
Step 2
- Fasten to the wall
Fastening .......................................................................................................................... 6
Step 3
- Connection and venting
Plumbing connections ....................................................................................................... 8
Venting .............................................................................................................................. 8
Electrical connections ....................................................................................................... 9
Step 4
- Assembly
Assembly ........................................................................................................................... 10
Step 5
- Commission the Hydroboil
Earth continuity verification ................................................................................................. 11
Turn the mains power and water on .................................................................................... 11
Trouble shooting
Trouble shooting table .................................................................................................................. 12
Operation
Operation ..................................................................................................................................... 12
Appendix
Mounting templates ...................................................................................................................... 13
Spare parts ................................................................................................................................... 15
End of life disposal ....................................................................................................................... 19
Cleaning ....................................................................................................................................... 19
Contact details ............................................................................................................................. 20
Intended use
This appliance is intended to be used in commercial applications such as:
• Staff kitchens, shops, offices and other working environments.
• Small hotels and bed and breakfast type environments.
• Catering and similar non-retail applications.
For list of models falling within the scope of this manual, please refer to the Technical specication table, page 5.
03
Installation instructions & user manual
804545UK V2.03 Aug 2018 - Zip Hydroboil
Technical support
Tel: 0345 6 005 005 Email: service@zipindustries.co.uk w ww.zipwater.co.uk
WARNINGS AND PRECAUTIONS
!
This manual contains important safety and installation instructions for the Zip Hydroboil. Please read all warnings, installation requirements and installation instructions before installing any Zip Hydroboil. This system must be installed in accordance with water supply byelaws, current IEE regulations and relevant local authority byelaws.
Warnings
The Zip Hydroboil must be earthed. The resistance of the earth connection from each exposed metal part must be less than 1Ω.
All installation and service work must be completed by trained and suitably qualified tradespeople. Faulty operation due to unqualified persons working on this product, or any other Zip product may void warranty coverage.
• Never attempt to install a Zip Hydroboil instant boiling water heater without reading all of the applicable instructions.
• Do not remove the cover of the Hydroboil under any circumstances without first isolating it from the power supply.
• In hard water areas mineral scale accumulation in the boiling chamber of the Zip Hydroboil may become a problem, consideration should be given to the maintenance required. A suitable form of water treatment may be necessary.
• The Zip Hydroboil instant boiling water heater is not intended for use by young children or infirm people without supervision.
• Young children should be prevented from having access to ensure that they are not able to use or play with the Hydroboil.
• Do not use strong, corrosive or abrasive cleaners to clean the case of the Hydroboil.
• The ambient temperatures this Hydroboil must operate within is 5ºC - 50ºC.
• The Hydroboil is intended only for indoor use and should never be installed outdoors or be exposed to the elements of nature.
• This Hydroboil must not be positioned in an area that may be cleaned by a water jet. The Hydroboil must not be cleaned by a water jet.
As the installer, it is your responsibility to supply (if necessary) and install all valves as required by local regulations and relevant standards.
The Hydroboil is rated for 230V 50Hz AC operation.
Due to the process of continuous improvement, Zip reserves the right to change details mentioned in this manual, without notice.
Visit www.zipwater.co.uk to ensure you have the latest copy of this document.
04
Installation instructions & user manual
804545UK V2.03 Aug 2018 - Zip Hydroboil
Technical support
Tel: 0345 6 005 005 Email: service@zipindustries.co.uk w ww.zipwater.co.uk
WARNINGS AND PRECAUTIONS
Safety
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. For products sold in Europe, this appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children should be supervised to ensure that they do not play with the appliance. Cleaning and user maintenance shall not be made by children. This appliance is intended to be used in commercial applications.
Qualifications
If the power cable is damaged it must be repaired only by a qualified technician. To avoid hazards, all installation procedures must be carried out by a suitably qualified tradesperson.
Venting
Occasionally steam and / or boiling water may discharge through a vent outlet or the tap. Ensure the tap body is located so the tap outlet safely dispenses into the drip tray or sink bowl area, and that the vent is plumbed to a safe location, see page 8.
Lifting
Take care when lifting. The Hydroboil may exceed safe lifting limits. If you feel this is beyond your personal capabilities, please seek assistance with the lift. Do not lift the Hydroboil by the tap, fascia or any of its connections. Refer to the Technical specification, page 5 for the weight of the product.
Positioning
It is important to ensure the Hydroboil is positioned in an accessible area. The Hydroboil must have it’s base mounted in a horizontal position.
!
!
Before installation
Before installation ensure that provision has been made for the following
Review of all the technical specifications.
Ensure the mounting wall can support the product weight when full of water (See Technical specification, page 5).
Sufficient space to install the Hydroboil and other components in accordance with these installation instructions.
• Position the heater so there is at least 150 mm clearance above the heater for service access, 65 mm to its left and 20 mm to its right – the tap nozzle is usually positioned nominally 360 mm above a draining board, drip tray or sink bowl area.
For under 3kW rated models Zip Hydroboil models user easy accessible 1 x 230V AC 13A double pole isolation switch, or socket ( correctly rated for the appliance) is required. For 5.6kW rated models connect via a separate 230V AC ring main rated at no less that 32A isolated by a user easy accessible double pole isolation switch.
The Hydroboil must be connected in accordance with IEE regulations. See
05
Installation instructions & user manual
804545UK V2.03 Aug 2018 - Zip Hydroboil
Technical support
Tel: 0345 6 005 005 Email: service@zipindustries.co.uk w ww.zipwater.co.uk
Before installation
Technical specification, page 5 for power ratings.
Note Check cable and plumbing against inlet /outlet positions before proceeding.
A wholesome water supply connection with isolating valve within reach of the Hydroboil and positioned so that the stop cock will not be obstructed when the Hydroboil is installed.
• Vent / outlet drainage to a draining board, drip tray or sink bowl area
.
A wholesome cold water supply with a minimum working pressure of: (see Technical specification, below min. / max. water supply pressure).
A 0.35 MPa (3.5 bar) pressure limiting valve supplied must be fitted if the incoming mains water pressure is likely to exceed 0.5 MPa (5.0 bar).
The Hydroboil must be placed with its base in a horizontal position.
IMPORTANT!
Do not proceed with the installation if these requirements are not met.
Technical specification
Product
code
Tank
size
(litres)
Heat up
time
(Inlet
15°C)
Heat up
time (Inlet 10°C)
Rated voltage and
power
Dimensions
(mm)
W x D x H
Filled
weight(Kg)
301552 1.5 10mins 11mins 220-240V, 50Hz, 1400W 289 x 180 x 335 10.0
303552 3.0 16mins 17mins 220-240V, 50Hz, 1400W 289 x 180 x 431 12.5
305552 5.0 16mins 17mins 220-240V, 50Hz, 2200W 318 x 198 x 465 16.5
307552 7.5 23mins 23mins 220-240V, 50Hz, 2200W 318 x 198 x 578 20.5
310552 10.0 38mins 40mins 220-240V, 50Hz, 2800W 390 x 244 x 600 29.5
315552 15.0 40mins 43mins 220-240V~, 50Hz, 2800W 390 x 299 x 600 34.5
325552 25.0 47mins 50mins 220-240V~, 50Hz, 2800W 390 x 299 x 780 47.0
340552 40.0 60mins 64mins 380-415V, 2N~, 50Hz, 5600W 515 x 284 x 840 71.0
Min / Max water supply pressure
Hydroboil.........................................0.07 MPa (0.7 bar) - 0.5 MPa (5.0 bar)
WARNING ! If the incoming mains water pressure is likely to exceed 0.5 MPa (5.0 bar), a 0.35 MPa (3.5 bar) pressure limiting valve must be installed in the cold water supply line.
Note Optional Water Block is recommended to be fitted in the water supply line to minimise the potential damage in the event of leakage, call Zip on 0345 6 005 005.
!
06
Installation instructions & user manual
804545UK V2.03 Aug 2018 - Zip Hydroboil
Technical support
Tel: 0345 6 005 005 Email: service@zipindustries.co.uk w ww.zipwater.co.uk
Installation instructions
Before You Begin
Locate the paper mounting-hole template packed with the Hydroboil. (Also see pages 13, 14).
Read the installation and operating instructions completely.
Decide whether to install with concealed or exposed plumbing connections.
Concealed connections are preferred for superior appearance.
Step 1 – Positioning
Position the Hydroboil so the spout will drain onto a draining board or drip tray.
Position the base of the tap nozzle to be not less than 280mm (nominally 360mm) above the draining board (height should be increased only if essential for filling larger vessels).
Provide clearance for service access of not less than 150mm top, 65 mm left, 20mm right.
Mark corner positions for the Hydroboil on the wall in order to position the paper mounting-hole template.
Step 2 – Fastening
Position mounting-hole template on wall and drill holes where shown.
Drill holes for water inlet and vent outlet if rear access is intended.
Install plumbing and wiring and prepare pipe ends as shown adjacent & on page 8.
Remove cover fastening screws from Hydroboil and lift off cover.
Screw Hydroboil chassis to the wall using screws or bolts suited to the wall, (supplied).
Fasteners must be able to support the product weight when full, (see Technical specification, page 5).
45mm
Elbow
Inlet clearance
Cold
inlet
Vent
outlet
Inlet
position
Vent
position
3 to 7.5 litre models
Strain relief bush (cable gland)
Terminal block
Escutcheon
Tap nut
Tap
Concealed access