Zip HT2784Z8, HT4784Z8, HT4784Z6, HT4784Z4, HT4784Z10 User Manual

...
802254 - HT BC, BCHA, AIO, User Guide - June 2015 - V2.00 Page 1 of 24
ZIP HydroTap G4
User Guide
®
Tap Operation...................(Pages 2-8)
LCD Screen & Menu .......(Pages 9-20)
Date of Installation............../.........../..........
Affix Model Number Label
Here
802254
BC Compact
ON - OFF Switch
Page 2 of 24 802254 - HT BC, BCHA, AIO, User Guide - June 2015 - V2.00
The safety lock feature is provided to prevent boiling water flowing if the hot lever is inadvertently operated. This function can be activated and deactivated from either the Tap or from the touch screen display (Located on the unit in the cupboard).
Safety Lock
3. Tap Safety
HydroTap Classic
To set the tap safety setting: (Classic & Elite)
1.
Press [MENU] button for main menu.
2.
Press [Setting] button.
3.
Press [Safety] button.
4.
Press button -YES / NO to allow or disallow the safety setting to be changed on the tap.
Note: The Factory setting is set at YES
A
B
C
A
To activate the safety for Classic & Elite taps
(From the tap):
After selecting to allow the safety setting from the menu screen. Place a finger on the safety lock, then depress the Classic Blue/Chilled lever or touch the Elite Blue/ Chilled Button, while keeping both fingers in position for a period of approximately ten seconds.The Classic safety lock indicator light will now be illuminated or the Elite lights will flash, momentarily.
To deactivate the safety
(From the tap):
First place a finger on the safety lock, then depress the Classic Blue/Chilled lever or touch the Elite Blue/Chilled Button, while keeping both fingers in position for a period of approximately ten seconds. The Classic safety lock indicator light will now extinguish or the Elite lights will flash, momentarily.
To control the safety
(From the touch screen):
(see page 20)
For Hot Isolation:
Not for HydroTap Arc/Cube, (see page 20)
Elite Tap
802254 - HT BC, BCHA, AIO, User Guide - June 2015 - V2.00 Page 3 of 24
Safety Lock
Indicator
light
Arc/Cube
Tap
3. Tap operation
To dispense boiling water:
(With the safety OFF)
HydroTap Classic:
Depressing the Red lever allows the dispensing of boiling water.
Pulling forward the Red lever allows the tap to operate in a “no-touch” mode.
Water will flow from between 5 and 15 seconds (This is user adjustable).
To reset, return the handle to the “Off” position and repeat the step. The lever has to be manually returned to the “Off” position.
Elite Tap:
Touching the boiling button allows the dispensing of boiling water.
HydroTap Arc/Cube:
Tap the select button until the indicator light turns RED.
Rotating the control, when the indicator light is RED, allows the dispensing of boiling water.
Press or pull lever
To dispense chilled water:
HydroTap Classic:
Depressing the “Blue” lever allows the dispensing of chilled water.Pulling forward the Blue lever allows the tap to operate in a “no-touch” mode. Water will flow from between 5 and 15 seconds (This is user adjustable). To reset, return the handle to the “Off” position and repeat the step. The lever has to be manually returned to the “Off” position.
Elite Tap:
Touching the chilled button allows the dispensing of chilled water.
HydroTap Arc/Cube:
If showing RED, tap the select button until the indicatorl light turns BLUE.
Rotating the control, when the indicator light is BLUE, allows the dispensing of chilled water.
Elite Tap
Classic
Tap
Page 4 of 24 802254 - HT BC, BCHA, AIO, User Guide - June 2015 - V2.00
3. Tap operation
Elite Tap:
The Elite tap uses touch sensitive controls, to dispense Boiling and Chilled water.
When operating the tap, ensure the touch surface is dry as moisture may interfere with the sensor touch control.
The safety lock can be controlled from either the tap or from the touch screen display in the same way as the Classic tap (See page 2)
To dispense Boiling water: (With the safety ON)
HydroTap Classic:
Depress the Red lever, while simultaneously covering the safety lock button with a second finger. These two actions need to occur simultaneously within 2 seconds for the successful dispensing of boiling water.
Elite Tap:
Place a finger on the safety lock, then touch the boiling button, while keeping both fingers in position.
HydroTap Arc/Cube:
Tap the select button until the indicator light turns RED. Then tap the safety button twice until the RED light flashes (This will flash for aprox 2 seconds). Boiling water may be dispensed by rotating the control while the RED light is flashing.
Boiling Button
Chilled Button
Safety Lock
3. Tap functions
802254 - HT BC, BCHA, AIO, User Guide - June 2015 - V2.00 Page 5 of 24
3. Tap functions
MixerTap:
Lifting the handle up will decrease the flow rate and lowering the handle will increase the flow rate. Raise the handle all the way up to turn the tap off.
When the handle is moved towards the BLUE mark, the temperature is decreased and when moved towards the RED mark, the temperature is increased. The final temperature will depend on the temperature of the incoming cold water.
On powerup, wait 30secs. for the unit to calibrate before selecting either the Boiling (RED) with safety, or Chilled (BLUE) water mode, by tapping the select button. The Arc/Cube control may be rotated in a forward or reverse direction to dispense Boiling or Chilled water.
The rotary control is spring loaded in the anticlockwise direction and when released, will return to the OFF position. When rotated clockwise the tap operates in a “Pot fill” mode. Water will flow from between 5 and 15 seconds (This is user adjustable). To reset, return the handle to the “Off” position and repeat the step. The lever has to be manually returned to the “Off” position. After selecting Boiling mode, the light on top of the rotary control will flash for 2 seconds, during which time you may dispense water. When the rotary control is returned to the Off position the light will continue to flash for an additional 3 seconds, allowing you to dispense more water. When unattended, the control light will automatically default to the Chilled (BLUE) mode after 30 seconds.
Rotary control
Select Button
Safety Lock
HydroTap Arc/Cube:
Page 6 of 24 802254 - HT BC, BCHA, AIO, User Guide - June 2015 - V2.00
All-In-One Tap:
The top of the All-In-One tap is operated the same as a Classic HydroTap. The two levers are used for dispensing boiling and chilled water. The safety button operating in the same way as on the HydroTap.
The Mixer tap lever is operated as a classic ‘Flick Mixer’. The hot side is marked with a red mark and the cold side with a blue mark, for dispensing cold to warm water.
Lifting the handle up will decrease the flow rate and lowering the handle will increase the flow rate. Lift the handle all the way up to turn the tap off.
When the handle is moved towards the blue mark, the temperature is decreased and when moved towards the red mark, the temperature is increased. The final temperature will be dependant on the temperature of the incoming cold water.
For convenience, the spout may be swivelled, left or right through 120°.
Light intensity varies from site to site, therefore it is recommended that a re-calibration be performed at the time of the installation. All direct natural sun light must be shaded from the HydroTap, during the calibration. This can be achieved by closing any nearby curtains, blinds, etc. or by shading the tap with a dark cloth.
Safety Sensor Calibration (lever models)
Pull both levers forward
Safety sensor
3. Tap functions
1.
With the unit in Normal operating mode and with the safety enabled
2.
Turn the power OFF
3.
Pull both tap levers to the forward position
4.
Turn ON the power
5.
The unit will calibrate the safety switch
6.
Return the levers to the neutral position.
7.
To check the calibration, dispense Boiling water, in normal light conditions with the safety enabled.
802254 - HT BC, BCHA, AIO, User Guide - June 2015 - V2.00 Page 7 of 24
Tap lights
Warning: (All)
Flashing warning light:
When the indicator light flashes fast and continuous, a system fault has occurred. Check for details on the faults screen. If unable to rectify, call a qualified service agent.
Filter light
Blue Chilled Water Light:
(Not available on Elite)
On all the time:
This indicates that the temperature of the chilled water is within the set temperature range.
Flashing slowly:
This indicates that the chilled water is not within the set temperature range. While flashing, water may be dispensed, but not at the set temperature. When the chilled water is at the set temperature, the light will stop flashing. This may take several minutes. During heavy usage, the temperature may rise out of the normal range.
Blue LightsRed Lights
Red Boiling Water Light:
(All)
On all the time:
This indicates that the boiling water is ready.
Flashing slowly:
This indicates that the boiling water is below the desired temperature. Wait for the light to stop flashing before dispensing water. The flashing light will typically occur after switching on, or coming out of sleep mode.
Filter LightRed Light
Elite Tap
Classic
Tap
Page 8 of 24 802254 - HT BC, BCHA, AIO, User Guide - June 2015 - V2.00
Filter light:
Classic & Elite
Filter Light Off:
This indicates the filter is operating within its normal specified lifespan.
Filter Change light flashing slowly:
The light will flash slowly when the filter is due for replacement and the LCD will show “Filter Change”. Refer to “Replacing the filter” in section ‘C’ of this document.
Filter Light
Filter light
Filter Lights
HydroTap Arc/Cube:
Flashing filter lights:
All three tap lights (Safety; Select and Indicator light) will flash every 10 seconds, indicating a Filter change is required.
Safety Light
Indicator
light
Select light
Elite Tap
Classic
Tap
Turn filter light OFF: (All models)
Refer to “Filter Reset” in section ‘C’ of this document.
Loading...
+ 16 hidden pages