802254 - HT BC, BCHA, AIO, User Guide - June 2015 - V2.00 Page 1 of 24
ZIP HydroTap G4
User Guide
®
•
Tap Operation...................(Pages 2-8)
•
LCD Screen & Menu .......(Pages 9-20)
•
Maintenance.................... (Pages 21-24)
Date of Installation............../.........../..........
Affix Model Number Label
Here
802254
BC Compact
ON - OFF
Switch

Page 2 of 24 802254 - HT BC, BCHA, AIO, User Guide - June 2015 - V2.00
The safety lock feature is provided to prevent boiling water flowing if the hot
lever is inadvertently operated.
This function can be activated and deactivated from either the Tap or from the
touch screen display (Located on the unit in the cupboard).
Safety Lock
3. Tap Safety
HydroTap Classic
To set the tap safety setting: (Classic & Elite)
1.
Press [MENU] button for main
menu.
2.
Press [Setting] button.
3.
Press [Safety] button.
4.
Press button -YES / NO to
allow or disallow the safety
setting to be changed on the tap.
Note: The Factory setting is set at YES
A
B
C
A
To activate the safety
for Classic & Elite taps
(From the tap):
After selecting to allow the safety setting
from the menu screen. Place a finger on
the safety lock, then depress the Classic
Blue/Chilled lever or touch the Elite Blue/
Chilled Button, while keeping both fingers
in position for a period of approximately
ten seconds.The Classic safety lock
indicator light will now be illuminated or
the Elite lights will flash, momentarily.
To deactivate the safety
(From the tap):
First place a finger on the safety lock,
then depress the Classic Blue/Chilled
lever or touch the Elite Blue/Chilled
Button, while keeping both fingers in
position for a period of approximately ten
seconds. The Classic safety lock indicator
light will now extinguish or the Elite lights
will flash, momentarily.
To control the safety
(From the touch screen):
(see page 20)
For Hot Isolation:
Not for HydroTap Arc/Cube, (see page 20)
Elite Tap

802254 - HT BC, BCHA, AIO, User Guide - June 2015 - V2.00 Page 3 of 24
Safety Lock
Indicator
light
Arc/Cube
Tap
3. Tap operation
To dispense boiling
water:
(With the safety OFF)
HydroTap Classic:
Depressing the Red lever allows the
dispensing of boiling water.
Pulling forward the Red lever allows the
tap to operate in a “no-touch” mode.
Water will flow from between 5 and 15
seconds (This is user adjustable).
To reset, return the handle to the “Off”
position and repeat the step. The lever
has to be manually returned to the “Off”
position.
Elite Tap:
Touching the boiling button allows the
dispensing of boiling water.
HydroTap Arc/Cube:
Tap the select button until the indicator
light turns RED.
Rotating the control, when the indicator
light is RED, allows the dispensing of
boiling water.
Press or pull lever
To dispense chilled water:
HydroTap Classic:
Depressing the “Blue” lever allows
the dispensing of chilled water.Pulling
forward the Blue lever allows the tap to
operate in a “no-touch” mode. Water will
flow from between 5 and 15 seconds
(This is user adjustable). To reset,
return the handle to the “Off” position
and repeat the step. The lever has to be
manually returned to the “Off” position.
Elite Tap:
Touching the chilled button allows the
dispensing of chilled water.
HydroTap Arc/Cube:
If showing RED, tap the select button
until the indicatorl light turns BLUE.
Rotating the control, when the indicator
light is BLUE, allows the dispensing of
chilled water.
Elite Tap
Classic
Tap

Page 4 of 24 802254 - HT BC, BCHA, AIO, User Guide - June 2015 - V2.00
3. Tap operation
Elite Tap:
The Elite tap uses touch
sensitive controls, to
dispense Boiling and
Chilled water.
When operating the tap,
ensure the touch surface
is dry as moisture may
interfere with the sensor
touch control.
The safety lock can be
controlled from either
the tap or from the touch
screen display in the
same way as the Classic
tap (See page 2)
To dispense Boiling water: (With the safety ON)
HydroTap Classic:
Depress the Red lever, while simultaneously covering the safety lock button
with a second finger. These two actions need to occur simultaneously within
2 seconds for the successful dispensing of boiling water.
Elite Tap:
Place a finger on the safety lock, then touch the boiling button, while keeping
both fingers in position.
HydroTap Arc/Cube:
Tap the select button until the indicator light turns RED. Then tap the safety
button twice until the RED light flashes (This will flash for aprox 2 seconds).
Boiling water may be dispensed by rotating the control while the RED light is
flashing.
Boiling Button
Chilled Button
Safety Lock
3. Tap functions

802254 - HT BC, BCHA, AIO, User Guide - June 2015 - V2.00 Page 5 of 24
3. Tap functions
MixerTap:
Lifting the handle up will
decrease the flow rate and
lowering the handle will
increase the flow rate. Raise
the handle all the way up to
turn the tap off.
When the handle is moved
towards the BLUE mark, the
temperature is decreased
and when moved towards the
RED mark, the temperature
is increased. The final
temperature will depend
on the temperature of the
incoming cold water.
On powerup, wait 30secs. for
the unit to calibrate before
selecting either the Boiling
(RED) with safety, or Chilled
(BLUE) water mode, by
tapping the select button.
The Arc/Cube control may be
rotated in a forward or reverse
direction to dispense Boiling
or Chilled water.
The rotary control is spring
loaded in the anticlockwise
direction and when released,
will return to the OFF position.
When rotated clockwise the
tap operates in a “Pot fill”
mode. Water will flow from
between 5 and 15 seconds
(This is user adjustable). To
reset, return the handle to
the “Off” position and repeat
the step. The lever has to be
manually returned to the “Off” position.
After selecting Boiling mode, the light on top of the rotary control will
flash for 2 seconds, during which time you may dispense water. When
the rotary control is returned to the Off position the light will continue to
flash for an additional 3 seconds, allowing you to dispense more water.
When unattended, the control light will automatically default to the Chilled
(BLUE) mode after 30 seconds.
Rotary control
Select Button
Safety Lock
HydroTap Arc/Cube:

Page 6 of 24 802254 - HT BC, BCHA, AIO, User Guide - June 2015 - V2.00
All-In-One Tap:
The top of the All-In-One tap is operated the same as a Classic HydroTap.
The two levers are used for
dispensing boiling and chilled
water. The safety button operating
in the same way as on the
HydroTap.
The Mixer tap lever is operated
as a classic ‘Flick Mixer’. The hot
side is marked with a red mark
and the cold side with a blue
mark, for dispensing cold to warm
water.
Lifting the handle up will decrease
the flow rate and lowering the
handle will increase the flow rate.
Lift the handle all the way up to
turn the tap off.
When the handle is moved
towards the blue mark, the temperature is decreased and when moved
towards the red mark, the temperature is increased. The final temperature
will be dependant on the temperature of the incoming cold water.
For convenience, the spout may be swivelled, left or right through 120°.
Light intensity varies from site to site, therefore it is recommended that a
re-calibration be performed at the time of the installation.
All direct natural sun light must be shaded from the HydroTap, during the
calibration. This can be achieved by closing any nearby curtains, blinds, etc.
or by shading the tap with a dark cloth.
Safety Sensor Calibration (lever models)
Pull both levers forward
Safety
sensor
3. Tap functions
1.
With the unit in Normal operating mode
and with the safety enabled
2.
Turn the power OFF
3.
Pull both tap levers to the forward
position
4.
Turn ON the power
5.
The unit will calibrate the safety switch
6.
Return the levers to the neutral
position.
7.
To check the calibration, dispense Boiling water, in normal light
conditions with the safety enabled.

802254 - HT BC, BCHA, AIO, User Guide - June 2015 - V2.00 Page 7 of 24
Tap lights
Warning: (All)
Flashing warning light:
When the indicator light flashes fast and
continuous, a system fault has occurred.
Check for details on the faults screen. If
unable to rectify, call a qualified service
agent.
Filter light
Blue Chilled Water Light:
(Not available on Elite)
On all the time:
This indicates that the temperature of the
chilled water is within the set temperature
range.
Flashing slowly:
This indicates that the chilled water is not within
the set temperature range. While flashing,
water may be dispensed, but not at the set
temperature. When the chilled water is at the
set temperature, the light will stop flashing. This
may take several minutes.
During heavy usage, the temperature may rise
out of the normal range.
Blue LightsRed Lights
Red Boiling Water Light:
(All)
On all the time:
This indicates that the boiling water is ready.
Flashing slowly:
This indicates that the boiling water is below
the desired temperature.
Wait for the light to stop flashing before
dispensing water. The flashing light will typically
occur after switching on, or coming out of sleep
mode.
Filter LightRed Light
Elite Tap
Classic
Tap

Page 8 of 24 802254 - HT BC, BCHA, AIO, User Guide - June 2015 - V2.00
Filter light:
Classic & Elite
Filter Light Off:
This indicates the filter is operating within its
normal specified lifespan.
Filter Change light flashing slowly:
The light will flash slowly when the filter is due
for replacement and the LCD will show “Filter
Change”. Refer to “Replacing the filter” in
section ‘C’ of this document.
Filter Light
Filter light
Filter Lights
HydroTap Arc/Cube:
Flashing filter lights:
All three tap lights (Safety; Select and
Indicator light) will flash every
10 seconds, indicating a Filter change
is required.
Safety Light
Indicator
light
Select light
Elite Tap
Classic
Tap
Turn filter light OFF:
(All models)
Refer to “Filter Reset” in section ‘C’
of this document.