QUICK START GUIDE - (B & BA Res models)
Note: This quick start guide must be read in conjunction with the main installation and user instructions
Before installing ensure that the following have been provided at the Installation site:
•Review all the technical specifications.
•Ensure the underbench can support the product weight when full of water, (allow an extra 3-4kg when full. )
•Sufficient space in the cupboard to install all of the undersink units in accordance with these Installation Instructions. Refer to technical specification for dimensions. Make allowance for a booster heater and / or water softener if required. Refer to section 3 & 4, for Installation instructions.
•For Zip HydroTap B & BA models, a 220-240Vac, 10A GPO will be required. For Zip HydroTap BHA & BAHA models, two 220-240Vac, 10A GPOs will be required. (One GPO is for the Zip HydroTap and the other for the Booster heater).
NOTE: Check all cable and hose lengths against inlet /outlet positions before proceeding (See section 5 for general layout).
•A potable water supply connection with isolating valve inside the cupboard within reach of the braided hoses and positioned so that the connection point and the stop cock will not be obstructed when the undersink units are installed.
•If an external filtration or water softening device is required, then it is
important to allow extra space for these items.
•A cold water supply with a minimum working pressure of 172kPa (200kPa when a booster is fitted) and a maximum working pressure of 700kPa connected via an isolation valve.
•The appliance must be placed with it’s base in a horizontal position.
IMPORTANT! Do not proceed with the Installation if these requirements are not met.
Parts Supplied |
Description |
Parts Supplied |
Description |
1 off Hydrotap Tap and hoses
|
|
1 off |
1 off |
|
HydroTap |
|
Booster heater |
|
Undersink Unit |
|
|
|
and hoses |
|
with water filter |
|
|
|
(Supplied with |
|
|
|
|
|
|
BCHAV model) |
|
|
|
1 x Restrictaflow |
|
1 x Mixer tap for |
valve and Tee |
|
|
|
3-in-1 and 4-in-1 |
|
piece for Mixer |
|
|
|
models (with |
|
Taps and select |
|
|
|
hoses) |
|
models |
|
|
|
|
|
|
|
|
1 off Mains water |
|
1 x User guide and |
|
||
|
1 x Quick start |
|
connection hose |
|
|
|
guide |
|
|
|
STEP 1- Prepare and fit the Taps
|
|
Black plastic |
|
|
|
|
spacer |
|
|
|
ALL THREAD |
Stainless |
|
|
|
ROD |
|
||
|
washer |
|
||
|
|
|
||
|
|
|
SPIDER |
|
|
STAINLESS |
Fit the |
CLAMP |
|
BLACK |
STAINLESS STEEL |
|
||
STEEL |
|
|||
PLASTIC |
WASHER, |
6mm |
||
WASHER |
||||
SPACER |
SPIDER CLAMP, |
|||
NUT |
||||
|
||||
|
|
AND 6mm NUT. |
||
|
|
|
||
SPIDER |
|
|
|
|
CLAMP |
|
NOTE: feed each of the three tubes and |
||
|
|
|||
NUT |
|
electrical cable evenly in between the legs of |
||
|
the SPIDER CLAMP when installing. |
|||
|
|
|||
|
|
35mm dia hole |
|
|
Hole positioning: Position the tap such that it dispenses into |
|
|||
the sink bowl with ample clearance for a cup or tea pot. Alternatively, |
|
|||
the tap could be mounted away from the sink using a Zip Font, |
Sink |
|||
available as an accessory. |
|
|||
|
|
|||
Apply a light smearing of silicon sealant |
|
|
||
on the underside of the upper spacer to |
|
|
||
ensure a watertight fi t. |
|
|
For HydroTap & Mixer taps
cut a 35mm hole in the bench or sink top.
BENCH TOP
Ø35mm
•Fit the O-ring into the recess on the underside of the Mixer tap. (Note: If mounting on an uneven surface, a light smear of silicone on the seal ring will ensure a water tight seal)
•Affix the three hoses to the tap, noting their colour coding.
•Pass all hoses through the 35mm hole and position the tap so that it discharges into the sink.
•Fit the lower rubber seal to the threaded extension.
•Secure the tap in position with the metal washer and Nut.
O-RING
LOWER
RUBBER
WASHER
WASHER
NUT
Red band
Mixer Out
White Hose
External
Mains
Blue band
Mixer IN
Arc/Cube (If required)
NOTE: The tube kit must be fitted after the HydroTap has been mounted on the benchtop or sink. Refer to the tube kit assembly instructions, supplied with the tap kit.
1.Remove the 2 x spout locating screws and lower the spout to expose the plastic spring clip
NOTE: The plastic spring clip has two internal dimples that may be positioned in the 6 upper or 6 lower, pre drilled holes in the spout (see diags. below & Figs. 1.7 & 1.8)
2.To reposition the spout, gently spread the plastic spring clip to release the dimples from the spout holes. When released, slide the clip on the spout so that it ends up between the two rows of holes.
3.Rotate the plastic clip on the spout to orient the dimples, so they are in line with the newly selected holes.
NOTE: When determining which of the 6 holes are required for the new spout height and orientation, check the new plastic clip position will clear the undercut and that the wiring loom will not be pinched, when assembled.
4.Slide the plastic clip up/down to engage with the selected holes, making sure the two dimples engage simultaneously with the two selected holes.
NOTE: The clip will not fit correctly if one dimple engages before the other. Both dimples must engage at the same time.
5.With the clip fitted to the newly selected holes, carefully raise the spout (ensure
the wiring loom is a neat fit in the undercut and is located between the open ends of the clip) until the clip locating holes are in line with the spout locating screws.
6.Replace the 2 x locating screws.
7.If mounting on an uneven surface, apply a light smearing of silicon sealant on the O ring to ensure a watertight fit. (See fig. 1.9)
8.Pass the assembly through the 35mm hole and position the tap so it discharges into the sink.
9.Fit the lower rubber seal to the threaded extension.
10.Secure the tap in position with the metal washer and nut.
11.Fit the tube kit, as supplied.
Plastic spring clip
Spout locating screws (2)
Clip locating holes (2)
Undercut for loom
Lower locating positions
Plastic spring clip
Upper locating positions
Dimples
NOTE: the spout is fixed and does not swivel
All-In-One Tap (If required)
For All-In-One taps cut a 50mm hole in the bench or sink top.
Bench top
50mm
Note: make sure the tap location will allow the nozzle to drain into the sink.
802259 - B, BA, BHA, BAHA, Quick Start Guide - July 2015 - V2.00