Zip HT2784Z8, HT4784Z8, HT4784Z6, HT4784Z4, HT4784Z10 Installation Guide

...
802253 - HydroTap BC, BCHA -AV, AIO, Installation Instructions - June 2015 - V2.01 Page 1 of 36
Zip HydroTap G4
Installation Instructions
Affix Model Number Label
Here
802253
Filtered boiling and chilled drinking water for residential use.
Page 2 of 36 802253 - HydroTap BC, BCHA-AV, AIO, Installation Instructions - June 2015 - V2.01
HydroTap Specifications
Installation check list .................................................................................................................... 3
General Product Features ............................................................................................................ 4
Important Safety Instructions .......................................................................................................5
Warnings and Regulatory Information ..........................................................................................6
Major components and Accessories ............................................................................................ 7
Technical Specification ................................................................................................................8
Before Installation and site requirements ..................................................................................... 9
Installation Instructions STEP 1 -
Measure and cut all the tap holes before fitting the taps
Section 1 - Tap Installation instructions
1.1 - HydroTap Tap Classic & Elite tap Installations ......................................................... 10-12
1.6 - HydroTap Arc/Cube tap Installations ........................................................................ 13-14
1.10 - Mixer Tap Installation .............................................................................................. 15-17
1.14 - All-In-One Tap with MAINS and VENTED Installation ............................................ 18-21
STEP 2
- Check for adequate ventilation
Section 2- Ventilation
2.1- Vent cut out details..................................................................................................... 22-24
STEP 3
- Install the Booster Heater (if required)
Section 3 - Booster heater Installation
3.1- Booster Heater specifications and Installation ........................................................... 25-27
STEP 4
- Install the undersink unit
Section 4 - Undersink unit installation
4.1- Check the external bypass valve setting ...................................................................28
4.2- Fit the mains water supply hose ................................................................................28
4.3- Model BC 160/125 and BC 160/175 .......................................................................... 29
4.4- Model AIO Mains .......................................................................................................30
4.5- Model AIO Vented ......................................................................................................31
4.6- Model 4-In-1 Vented ..................................................................................................32
STEP 5
- Commission the HydroTap
Section 5 - Commissioning
5.1- Select the Language .................................................................................................. 33
5.2- Filter Flush ................................................................................................................. 33
5.3- Flow Calibration ......................................................................................................... 33
5.4 Boiling Calibration ....................................................................................................... 34
5.5- Booster activation ......................................................................................................34
5.6- Safety Sensor Calibration .......................................................................................... 34
Trouble Shooting
Trouble Shooting Table ................................................................................................................ 35
End of life disposal ....................................................................................................................... 36
Contact details .............................................................................................................................36
Index
802253 - HydroTap BC, BCHA -AV, AIO, Installation Instructions - June 2015 - V2.01 Page 3 of 36
Before Installation:
A. Read the instructions and check if there is adequate space to mount all of the components.
B. Note: Not all fittings are supplied with the appliance kit. Isolation valves are not supplied.
C. Check the mains water pressure is between 172 - 700kPa and 200 - 700kPa when a booster and /or filter softener is fitted
D. Check the water quality to determine if extra filtration will be required. NOTE: This product must be fitted to a potable water supply
E. Check the appliance rating plate and ensure correct power is available for the appliance.
F. Check the under counter cupboard supporting the appliance is adequate for the total weight of the appliance, when full of water.
Before Commissioning:
1. Check the unit has been installed correctly.
2. Check all plumbing fittings have been tightened.
3. Ensure the outlet and vent pipes are positioned to drain correctly.
4. Ensure there is adequate ventilation.
5. Check all tubes from the undersink unit to the tap, have a constant rise and there are no sags or kinks in the hoses.
6. Check all electrical connections are correct and there are no loose wires.
Commission: (See section 5)
7. Flush the supply line before connecting.
8. Turn on the water and check for leaks.
9. Flush the filter(s).
10. Where applicable, programme the unit to suit the customer’s requirements.
Installation checklist
Page 4 of 36 802253 - HydroTap BC, BCHA-AV, AIO, Installation Instructions - June 2015 - V2.01
Thank you for purchasing a Zip HydroTap. Please read and follow these instructions carefully to ensure safe and trouble free service. If service is required, please call 1800 460 222
What is the Zip HydroTap ?
The Zip HydroTaps are electronically controlled, filtered, Boiling water and Chilled water drinking systems for kitchens and tea rooms. The HydroTap units are under bench drinking water appliances with a dispensing tap mounted on a sink or bench, which has been designed for residential applications. These units utilise a conventional refrigerant compressor to chill the water and an immersion heating element to boil the water. These units dispense boiling water (factory set to 98°C) and chilled water (factory set to 6-10°C). These units are NOT designed to be used for sanitary fixtures. The Boiling water units are fitted with a tap mounted, child safety lock. In addition, there are various energy saving options accessible via the main menu. Each unit is equipped with a self-calibrating program which caters for altitude adjustment. The water filter is a disposable item which will require periodic replacement and is covered by a limited OEM warranty. It is important that the Installation be done safely, correctly and completely, in order to utilise all the benefits the HydroTap can provide. The Classic and All-In-One taps may be ordered with the Tap Head Assembly for Disabled use. The disabled levers are supplied with Braille caps for the visually impaired.
General Product Features
Usage:
The Zip HydroTap is intended for use in residential household and similar applications such as, Rural and urban residential Kitchens, Hotels, Motels, Bed and Breakfast and other residential type environments.
ON-OFF Switch
Command centre
Din plug
(for accessories)
802253 - HydroTap BC, BCHA -AV, AIO, Installation Instructions - June 2015 - V2.01 Page 5 of 36
Important Safety Instructions
This manual contains important safety, Installation instructions for the Zip HydroTap G4.
Safety
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
For products sold in Europe, this appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Refrigerant
The Zip HydroTap unit contains R134A refrigerant under pressure. Maintenance of the refrigeration unit must be carried out by an accredited service provider or qualified refrigeration technician.
Qualifications
If the power cable is damaged it must be repaired only by a qualified technician. To avoid hazards, all Installation procedures must be carried out by a suitably qualified tradesperson. The power cable and power outlet must be in a safe visible position for connection.
Venting
Sometimes steam and / or condensed droplets may discharge through a vent outlet at the tap. If the tap is not installed using the Font pedestal, ensure the tap body is located so the tap outlet safely dispenses into the sink bowl area.
Lifting
Take care when lifting the Zip HydroTap unit. Some units may exceed safe lifting limits. If you feel this is beyond your personal capabilities, please seek assistance with the lift. The weights of the units are marked on the packaging. Do not lift the unit by the front cover or any connections at the top rear of the unit. Refer to section 1.2 technical specification for the weight of your product.
Airflow
The ambient operating temperatures, when installed in a cupboard, must be between 5ºC - 35ºC. The system will operate satisfactorily only if the recommended air gaps of 50mm on each side are provided. If a vent kit is supplied it must be fitted. See section 2 for correct installation details.
Altitude
Water boils at varying temperatures at different altitudes. Your HydroTap adjusts for this during startup calibration and will recalibrate itself on a regular basis.
Frost Protection
If this appliance is located where the ambient air temperature could fall below 5ºC when the heater is not in use, do not turn off the appliance electrically. This safeguard does not offer the same protection to the connecting pipework and fittings.
exposed to the elements of nature. This unit must not be positioned i
Page 6 of 36 802253 - HydroTap BC, BCHA-AV, AIO, Installation Instructions - June 2015 - V2.01
Important Safety Instructions
WARNINGS
1.
The Zip HydroTap unit must be earthed. The resistance of the earth connection from each exposed metal part must be less than 1 ohm.
2.
All Installation and service work must be completed by trained and suitably qualified Tradespeople. Faulty operation due to unqualified persons working on this product, or any other Zip product may void warranty coverage.
3.
All Plumbing must comply with AS/NZS3500.
4.
All Electrical must comply with AS/NZS3000
5.
All Plumbing and Electrical connections must be made in accordance with local regulations.
6.
This HydroTap product is rated for 230V 50Hz AC operation.
7.
Undersink units must never be located near, or cleaned with water jets.
8.
Zip HydroTaps are not to be exposed to the elements of nature
9.
Due to the process of continuous improvement, Zip Heaters reserves the right to change details mentioned in this manual, without notice.
Positioning
It is important to ensure the undersink unit is positioned in an accessible area close to the floor level. The unit must have it’s base mounted in a horizontal position with all inlets and outlets facing up. The Tap must be located above the undersink unit. See section 1 for details.x
802253 - HydroTap BC, BCHA -AV, AIO, Installation Instructions - June 2015 - V2.01 Page 7 of 36
Major components and accessories
Parts supplied Description
1 x Tap option with
hoses
(Classic tap shown)
1 x HydroTap
Undersink Unit with
air and water filters
1 x Mains water
connection hose
Vent Kit
1 x Inlet vent
1 x Outletvent
9 x Screws
1 off
HydroTap Booster
Heater & hoses.
(supplied with
BCHAV & 4-IN-1
models)
1 x Restrictaflow
valve and Tee piece
for Mixer taps and
select models
1 x User guide and
1 x Quick start guide
1 x Mixer Tap for 4-In-1 and select models (with hoses)
(ARC tap shown)
Guide
Accessories Description
HydroTap Booster
Water System with
connection hoses
Font Kit for
Arc & Cube Models
Font Kit for Classic &
Elite Models
Replacement Filter
Disabled lever Kit
4-In-1 Upgrade Kit
Page 8 of 36 802253 - HydroTap BC, BCHA-AV, AIO, Installation Instructions - June 2015 - V2.01
Technical Specifications
** Add an extra 5 kg when full of water
GPO's Required
Power Rating (kW)
Boost Rating (kW)
Unit Dimensions W x D x H (mm)
with air duct
**Dry
Weight
(KG)
Boiling Chilled
BC 1x10A 1.55 N/A 280 x 470 x 335 24
4 in 1
BCHA 2x10A 1.55 2.2 280 x 470 x 335 24
All in One
BCHA-A 1x10A 1.55 N/A 280 x 470 x 335 24 BCHA-AV 2x10A 1.55 2.2 280 x 470 x 335 24
Models
BC Boiling and Chilled
BCHA 4 in 1
A All in One - Mains
AV All in One - Vented
D Disabled lever controls (optional accessory)
802253 - HydroTap BC, BCHA -AV, AIO, Installation Instructions - June 2015 - V2.01 Page 9 of 36
Before Installation
Before installing ensure that the following have been provided at the Installation site:
Review all the technical specifications.
Ensure the underbench can support the product weight when full of water, (allow an extra 5 kg when full. )
Sufficient space in the cupboard to install all of the undersink units in accordance with these Installation Instructions. Refer to technical specification for dimensions. Make allowance for a booster heater and / or water softener if required. Refer to section 3 & 4, for Installation instructions.
For BC HydroTaps & BCHA-A (Mains) models, a 220-240Vac, 10A GPO will be required. For BCHA 4-In-1 & BCHA-AV (Vented) models, two 220-240Vac, 10A GPOs will be required. (One GPO is for the Zip HydroTap and the other for the Booster heater).
Note: Check all cable and hose lengths against inlet /outlet positions before pro­ceeding (See section 4 for general layout).
A potable water supply connection with isolating valve inside the cupboard within reach of the braided hoses and positioned so that the connection point and the stop cock will not be obstructed when the undersink units are installed.
For the mains pressure All-IN-ONE, an external hot and cold water supply will be required.
If an external filtration or water softening device is required, then it is important to allow extra space for these items.
A cold water supply with a minimum working pressure of 172kPa (200kPa when a booster and /or filter softener is fitted) and a maximum working pressure of 700kPa connected via an isolation valve.
The appliance must be placed with it’s base in a horizontal position.
IMPORTANT!
Do not proceed with the Installation if these requirements are not met.
Special Tools Required:
In addition to normal tools, the following will be required:
For the standard and Mixer taps:
35mm diameter sheet metal hole punch for sink tops. (Not supplied)
35mm diameter hole saw for timber bench tops. (Not supplied)
Nut runner tube spanner (supplied) for fixing tap assembly.
For the All-In-One tap:
50mm diameter sheet metal hole punch for sink tops. (Not supplied)
50mm diameter hole saw for timber bench tops. (Not supplied)
Nut runner tube spanner (supplied) for fixing tap assembly.
Page 10 of 36 802253 - HydroTap BC, BCHA-AV, AIO, Installation Instructions - June 2015 - V2.01
Hole positioning:
Position the tap such that it dispenses into the sink bowl with ample clearance for a cup or tea pot. Alternatively, the tap could be mounted away from the sink using a Zip Font, available as an accessory.
Section 1
Tap Installation
** Check bowl depth and adjust accordingly
TAP Recommended dispensing distance **
Elite 116 mm HydroTap Classic 116 mm HydroTap Arc/Cube 171 - 174 mm (Extended) All-In-One 211 mm Mixer - Arc neck 231 mm Mixer - Classic 270 mm Mixer - Cube neck 310 mm
116
BC HydroTap
Single Bowl
For Elite,Classic and Arc/Cube 35mm hole
For A-I-O 50mm and Mixer taps 35mm hole
Double Bowl
802253 - HydroTap BC, BCHA -AV, AIO, Installation Instructions - June 2015 - V2.01 Page 11 of 36
Apply a light smearing of silicon sealant on the underside of the spacer to ensure a watertight fit.
1.2
Cut a 35mm hole in the bench / sink top.
BENCH TOP
1.1
Ø35mm
ALL THREAD
ROD
STAINLESS
STEEL
SPACER
SPIDER
CLAMP
NUT
BLACK PLASTIC
SPACER
Tap assembly exploded view and kitchen layout side view.
470mm
335mm
HydroTap & Elite Installation
Min 300mm
HydroTap Classic
EliteTap