QUICK START GUIDE
CS and CSHA Commercial models
Note: This quick start guide must be read in conjunction with
the main installation and user manuals
• Before proceeding, read the installation and user instructions
• Check all the components are present and correct.
• Check that you have all the necessary tools
• Ensure the underbench can support the product weight when full of water,
(Check the specifications in the main book and allow an extra 4-5kg when full. )
Before installing ensure the following have been provided at
the installation site:
• Sufficient space in the cupboard to install all of the undersink units in accordance
with these Installation Instructions. Refer to technical specification for dimensions. If
required, make allowance for a booster heater. (Refer to the main book, for detailed
installation instructions).
• A potable water supply connection with isolating valve inside the cupboard within
reach of the flexible braided hose and positioned so that the connection point and the
stop cock will not be obstructed when all the undersink units are installed.
• For Zip HydroTap CS & CSHA models, a 220-240Vac, 10A GPO will be required.
NOTE: Check the cable lengths and outlet positions before proceeding.
• A potable cold water supply of between 250 - 700kPa
• Isolation valves for Hot and Cold water.
• For the CSHA model, both a hot and cold water supply will be required.
• The undersink appliances must be mounted in upright positions, with their bases
mounted horizontally, as shown in the diagrams.
IMPORTANT!
Do not proceed with the installation if these
requirements are not met.
Hole positioning: Position the tap such that it dispenses into
the sink bowl with ample clearance for a cup or tea pot. Alternatively,
the tap could be mounted away from the sink using a Zip Font,
available as an accessory.
The HydroTap Arc/Cube has a spout that may be fixed in one of 6 angular positions
(depending on the position of the rotary control) and fixed in one of two height positions.
The spout is fixed and does not swivel.
NOTE: The tube kit must be fitted after the HydroTap has been mounted on the benchtop
or sink. Refer to the tube kit assembly instructions, supplied with the tap kit.
NOTE: The plastic spring clip has two internal dimples that may be positioned in
the 6 upper or 6 lower, pre drilled holes in the spout (see diags. below )
NOTE: When determining which of the 6 holes are required for the new spout
height and orientation, check the new plastic clip position will clear the
undercut and that the wiring loom will not be pinched, when assembled.
NOTE: The clip will not fit correctly if one dimple engages before the other. Both
dimples must engage at the same time.
1 - HydroTap and Elite Tap
Black plastic
spacer
BLACK
PLASTIC
SPACER
SPIDER
CLAMP
NUT
ALL THREAD
ROD
STAINLESS
STEEL
WASHER
NOTE: feed each of the three tubes and
electrical cable evenly in between the legs of
the SPIDER CLAMP when installing.
Stainless
washer
Fit the
STAINLESS STEEL
WASHER,
SPIDER CLAMP,
AND 6mm NUT.
SPIDER
CLAMP
6mm
NUT
35mm dia hole
Sink
2 - HydroTap Arc/Cube
1.
Remove the 2 x spout locating screws and lower the spout to expose the plastic
spring clip
2.
To reposition the spout, gently spread the plastic spring clip to release the dimples
from the spout holes. When released, slide the clip on the spout so that it ends up
between the two rows of holes.
3.
Rotate the plastic clip on the spout to orient the dimples, so they are in line with the
newly selected holes.
4.
Slide the plastic clip up/down to engage with the selected holes, making sure the
two dimples engage simultaneously with the two selected holes.
5.
With the clip fitted to the newly
selected holes, carefully raise
the spout (ensure the wiring
loom is a neat fit in the undercut
and is located between the open
ends of the clip) until the clip
locating holes are in line with
the spout locating screws.
6.
Replace the 2 x locating screws.
7.
If mounting on an uneven
surface, apply a light smearing
of silicon sealant on the O ring
to ensure a watertight fit.
8.
Pass the assembly through the
35mm hole and position the tap
so it discharges into the sink.
9.
Fit the lower rubber seal to the
threaded extension.
10.
Secure the tap in position with
the metal washer and nut.
11.
Fit the tube kit, as supplied
Plastic spring clip
Dimples
Spout locating
screws (2)
Clip locating
holes (2)
Upper locating
positions
Undercut
for loom
Lower locating
positions
Plastic spring
clip
3 - Celsius Arc/Cube
Pass all the
•
hoses, tubes and
USB lead through
the 35mm hole.
• Ensure the
black rubber
seal is correctly
positioned to give
a water tight seal
• Secure the rubber
& brass washers
and large nut
from inside the
cupboard space,
as shown.
• Connect the
Hot and Cold
braided hoses
to the external
mains and hot
water supply
respectively.
• The blue and
white tubes are
connected to
the top of the
undersink unit.
(See step 6)
BENCH TOP
Ø35mm
Cut a 35mm hole in the bench / sink top.
BLACK RUBBER
BRASS
RUBBER
Washer
USB
PLUG
HOT & COLD
BRAIDED
HOSES
WASHER
BRASS
Y-PIECE
CHILLED
TUBE
SPARKLING
TUBE
Seal
NUT
JG
Apply a light smearing of silicon sealant on
the underside of the upper spacer to ensure a
watertight fi t.
804051 - CS. Quick Start Guide - Sept 2016 - v3.01
= =
max 43
314.00
12.00
12.00
285.00
12.00
5
326.00
A
A - KICKBOARD CUT-OUT
1.Drill 4 pilot holes Ø12 in corners
2.Finish cut-out using Jigsaw
and Keyhole or Wall Board saw
B - CABINET FLOOR
CUT-OUT
1.Drill two pilot holes Ø12
2.Finish cut-out using Jigsaw
C - CABINET FLOOR
CUT-OUT
1.Drill 4 pilot holes
Ø12 in corners
2.Finish cut-out using Jigsaw
and Keyhole or Wall Board saw
ATTENTION:
Insure that: Cut outs 'A' and 'B' are on opposite side of cabinet.
Cut out 'C' is straight behind'A'
60.00
B
C
12.00
45.00
284
4 - 2.640 KG - CO2 Cyl.
7 - Commissioning
This cylinder must be installed in an open plan area or in an enclosed room, with a
volume no less than 50m
3
. See details on the gas bottle and in the MSDS sheet for
a complete list of warnings.
1- After removing all packing material, mark out the cradle location, and fit it on a
suitable wall, within 1 metre of the unit. Make sure the gas bottle, regulator and
cradle assembly can comfortably fit, with sufficient clearances, before securing the
cradle inside the cupboard. Due to regulatory requirements the gas bottle must be
stored securely and in an upright position. Secure the bottle with the hook-andloopstraps provided.
2- After unpacking, fit the regulator to the gas bottle. Ensure the plastic seal is
fitted securely inside the large chrome nut, before attaching to the gas bottle.
If the plastic seal is not an easy fit over the spigot, soak it in hot water, before
re-applying. Do not force the seal to fit. Turn the regulator OFF by rotating the
regulator knob, all the way out, in an anti-clockwise direction.
NOTE: Two plastic seals are supplied with a new regulator. Only one is required,
the other is supplied as a spare part.
3- Connect the braided gas hose to the top of the underbench unit via the John
Guest fitting marked ‘Gas IN’ Then connect the threaded end to the regulator (Do
not lose the small sealing olive). When commissioning, turn the gas ON by rotating
the valve on top of the cylinder, anti-clockwise. Then adjust the outlet pressure, by
rotating the regulator knob in a clockwise direction, to between 2.7- 3.0 bar (green
zone)
NOTE:
The arrow should sit in the green zone of the regulator gauge; it should not
fall in the red or yellow sections.
4 -When commissioning, use soapy water to perform a leak test. Apply the soapy
water to the two gas connections using a sponge or brush. If any bubbles appear
and grow, there is a gas leak at the connection. Clean away the soapy residue
and tighten or refit the leaking connection. Make sure the gas is turned off when
tightening or refitting the leaking connection.
Fit the gas bottle into the cradle and secure with the Hook-and-loopstrap. Ensure
the bottle is in an upright position.
NOTE:
Care must be taken when working with high pressure carbon dioxide,
and in no case should the normal operating pressure of between 2.7- 3.0 bar be
exceeded.
5 - Ventilation
Cut out arrangement for
Chilled Sparkling models
with venting via a left hand
appliance duct.
C
louvre
(Option 1)
B
A
Typical airflow for sparkling models when no kickboard venting is possible
Front inlet vent
Cool Air IN
Min
100mm
Door outlet
Allow sufficient side clearance for cut out
Maintain 100mm clearance between &
cut outs
Side outlet vent (Option 2)
C
A B
Warm Air OUT
Note: For alternative options, refer to section 2 of the main instructions
6 - HydroTap Unit
Note: Remove all caps from the top of the undersink unit and Install the mains water
braided hoses to the undersink unit before locating the unit in place..
Commissioning the HydroTap
Turn on the water and gas to check for any leaks before turning on the power.
The system will promp you to select a language before continuing with the filter flush
procedure
CO2 Purge:
1.
Press the [START] button to
commence the purging process.
2.
Purge for 5 seconds and ensure all
water has stopped flowing through
Filter Flush:
Have a 10L bucket or similar container (not
supplied) at the ready to hold a quantity of
water that will be ejected while the Filter
Flush Mode is in operation. Open the filter
access door on the front of the HydroTap
and the filter cartridge will be exposed.
Located to the rear RHS of the cartridge is a
flush line, approx 600mm long and the flush
line stop cock. Place the valve end of the
flush line into the 10L bucket or container.
1.
Turn the stop cock ON
2.
Press [Start] button to start filter flush.
3.
Allow at least 10 litres of water to flush
through the filter.
4.
Once the filter flush is finished, Turn the stop
cock OFF then press [Stop] to end filter flush
mode.
the tap. (You will hear the CO
escaping from the tap).
3.
Press the [Stop] button.
4.
Press [Next] for the filter flush
screen
OPEN Position
ON
Stop cock
operation
OFF
CLOSED Position
2
gas
Min. 450mm
For positioning of cutout C use the template
marked on the cardboard carton
804051 - CS. Quick Start Guide - Sept 2016 - v3.01
Typical BCS cut out for
R/H vented models
GAS IN
BRAIDED
CO2
IN
Insulate the
Blue and
the White
tubes after
Trimming to
OUTLET
Note:
length
BLUE
WHITE
SPARKLING
OUTLET
USBCHILLED
POWER
CORD
Note:
- Mains hose length is 750mm
- Plug and Cord length is 1800mm
Position the under sink unit close
to the outlet tap, within reach of the
hose and cord lengths supplied
MAINS
IN