Zip Classic HydroTap G4 range, Elite HydroTap G4 range, HydroTap G4, Celsius HydroTap G4 range, Arc HydroTap G4 range Installation Instructions Manual

...
802261UK - HT G4 Residential chilled installation instructions - Sept 2016 - V2.05 Page 1 of 16
Zip HydroTap G4
Installation instructions
Affix model number label
here
802261UK
Filtered and chilled drinking water for residential kitchens.
VENTILATION IS
ESSENTIAL
SECTION 2 'VENTILATION'
READ BEFORE YOU START
!
READ
Page 2 of 16 802261UK - G4 Residential chilled installation instructions - Sept 2016 - V2.05
Tap options
The G4 series offers a range of interchangeable taps to suit the customer's needs
Classic HydroTap®G4 range
Arc / Cube HydroTap®G4 range
Elite HydroTap®G4range
These standalone taps are directly compatible with the G4 Command-CentreTM.
Celsius HydroTap®G4 range
The Celsius range offer instant boiling water together with the an integral mixer to provide mixed hot and cold water from the mains.
802261UK - HT G4 Residential chilled installation instructions - Sept 2016 - V2.05 Page 3 of 16
HydroTap®G4 specifications
Installation check list .................................................................................................................... 4
General product features ............................................................................................................. 5
Important safety instructions ........................................................................................................ 6
Warnings and regulatory information ........................................................................................... 7
Major components and accessories ............................................................................................. 8
Technical specifications ............................................................................................................... 9
Before installation and site requirements ..................................................................................... 10
Installation instructions Step 1 -
Measure and cut all the tap holes, fit the taps : Refer to 803341UK Tap installation
instructions supplied with the tap head.
Step 2
- Check for adequate ventilation.
Section 1- Ventilation.
1.1- Ventilation for all models.............................................................................................11
Step 3
- Install the Command-CentreTM.
Section 2 - Command-CentreTM installation.
2.1- HydroTap®G4 chilled models ..................................................................................... 12
2.2- HydroTap®G4 chilled and mixed hot and cold models............................................... 12
Step 4
- Commission the HydroTap®G4.
Section 3 - Commissioning.
3.1 - Select the language .................................................................................................. 14
3.2 - Filter flush ................................................................................................................. 14
3.3 - Flow calibration ......................................................................................................... 15
Trouble shooting
Trouble shooting table .................................................................................................................. 15
End of life disposal ....................................................................................................................... 15
Warranty ....................................................................................................................................... 16
Contact details ............................................................................................................................. 16
Index
Page 4 of 16 802261UK - G4 Residential chilled installation instructions - Sept 2016 - V2.05
Before installation
• Read the instructions and check if there is adequate space to install all of the components.
• Note Not all fittings are supplied with the appliance kit. Isolation valves are not supplied.
• Check the mains water pressure is within min / max requirements (see page 9).
• Note This product must be fitted to a potable water supply.
• Check the Command-CentreTM rating plate and ensure correct power is available.
• Check the under counter cupboard floor supporting the Command-CentreTM is adequate for its
total weight, when full of water.
Before commissioning
• Check the system has been installed correctly.
• Check all plumbing fittings have been tightened.
• Ensure the outlet and vent pipes are positioned to drain correctly.
• Ensure there is adequate ventilation.
• Check tubes from the Command-CentreTM to the tap have a constant rise and there are no sags or
kinks in the hoses.
• Check all electrical connections are correct and there are no loose wires.
Commissioning (see section 3)
• Flush the supply line before connecting.
• Turn on the water and check for leaks.
• Flush the filter.
• Where applicable, programme the Command-CentreTM to suit the customer’s requirements.
Installation checklist
802261UK - HT G4 Residential chilled installation instructions - Sept 2016 - V2.05 Page 5 of 16
Thank you for purchasing a Zip HydroTap®G4. Please read and follow these instructions carefully to ensure safe and trouble free operation. If help and advice is required, please call 0345 6 005 005.
What is the Zip HydroTap®G4 ?
This Zip HydroTap®G4
is an electronically controlled, filtered and chilled water drinking system for the kitchen. The HydroTap®G4 systems are under counter drinking water appliances with a dispensing tap mounted on a sink or worktop, which has been designed for residential applications. The HydroTap®G4 utilises a conventional refrigerant compressor to chill the water. This chilled model will dispense chilled water, factory set to 6-10°C. These units are NOT designed to be used as sanitary fixtures. The water filter is a disposable item which will require periodic replacement and is covered by a limited OEM warranty. It is important that the installation be undertaken safely, correctly and completely in order to utilise all the benefits that the HydroTap®G4
can provide. Each tap can be ordered with the tap head assembly for disabled
use. The disabled levers are supplied with Braille caps for the visually impaired.
General product features
Usage
The residential HydroTap®G4 range are intended solely for household use and not for commercial use.
Chilled Command-Centre
TM
ON/OFF
switch