Zip Autoboil 325051, Autoboil 340052, Autoboil 325052, Autoboil 313051, Autoboil 340051 Installation And Operating Instructions Manual

...
805194 09.17 1.02 Page 1 of 24
Zip Autoboil
315052 Zip Autoboil 15 Litre White
313051 Zip Autoboil 15 Litre Stainless Steel
325052 Zip Autoboil 25 Litre White
325051 Zip Autoboil 25 Litre Stainless Steel
340052 Zip Autoboil 40 Litre White
340051 Zip Autoboil 40 Litre Stainless Steel
Installation and Operating Instructions
Contents
Read These Warnings First ..............................................................................................................................................................3
Installation Requirements ...............................................................................................................................................................3
Installation Procedures ....................................................................................................................................................................4
Step 1 – Positioning ................................................................................................................................................. 4
Step 2 – Fastening .................................................................................................................................................... 4
Step 3 – Connecting ................................................................................................................................................5
3.1 Plumbing ................................................................................................................................................. 5
3.2 Venting ....................................................................................................................................................5
3.3 Electrical ..................................................................................................................................................6
Step 4 – Installing Tap ............................................................................................................................................6
Step 5 – Commissioning - Filter Flush & Calibrate ......................................................................................7
Menu Operation .................................................................................................................................................................................9
Wall Mounting Template Dimensions .....................................................................................................................................17
Spare Parts ............................................................................................................................................................................................ 18
Exploded View Diagram .................................................................................................................................................................. 19
Problem Solving .................................................................................................................................................................................20
Fault Codes Table ..............................................................................................................................................................................21
Earthing Continuity Verification ................................................................................................................................................... 21
Operating Procedures ...................................................................................................................................................................... 22
Filter Replacement ............................................................................................................................................................................22
Cleaning ................................................................................................................................................................................................23
End of Life Disposal ........................................................................................................................................................................... 23
Contact Details ....................................................................................................................................................................................24
Note:
All plumbing must comply with the relevant parts of AS/NZS 3500
All electrical must comply with the relevant parts of AS/NZS 60335/3000
This appliance is not intended for use by per­sons (including children) with reduced physical, sensory or mental capabilities, or lack of expe­rience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for their safety. For products sold in Europe, this appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand
the hazards involved. Children should be super­vised to ensure that they do not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
This appliance is intended to be used in house­hold and similar applications such as
- Sta kitchen areas in shops, o ces and other working environments;
- Farm houses and by clients in hotels, motels and other residential type environments;
- Bed and breakfast type environments;
- Catering and similar non-retail applications.
805194 09.17 1.02 Page 3 of 24
Read These Warnings First
Please read all installation requirements, installation procedures and precautions before installing any Zip Autoboil instant boiling water heater.
Never attempt to install any Zip Autoboil instant boiling water heater without reading all of the applicable instructions.
In some hard water areas where mineral scale accumulation in the boiling chamber of the Zip Autoboil may become a problem, consideration should be given to the maintenance required. A suitable form of water treatment may be necessary.
The cold water supply to this appliance must be potable and fall within your local authority’s guidelines.
All plumbing connections must be made in accordance with local regulations.
The Zip Autoboil instant boiling water heater is not intended for use by young children or infirm people without supervision.
Young children should be prevented from having access to ensure that they are not able to use or play with the heater.
This appliance must be earthed. If the power supply cord is damaged it must be replaced by a Zip authorised agent or a qualified electrician.
Do not remove the cover of the heater under any circumstances without first isolating the heater from the power supply.
Do not use strong, corrosive or abrasive cleaners to clean the case of the heater.
Frost protection: If this heater is located where ambient air temperature could fall below 5ºC when the heater is not in use, do not turn off the appliance electrically. This safeguide does not offer the same protection to the connecting pipework and fittings.
The ambient temperatures this unit must operate within is 5ºC ­50ºC.
This heater is intended only for indoor use and should never be installed outdoors or be exposed to the elements of nature.
This unit must not be positioned in an area that may be cleaned by a water jet. This unit must not be cleaned by a water jet.
Before installing, ensure that the following are available:
a) Sufficient space to position the heater so there is at least 100 mm
clearance above the heater for service access, 150 mm to its right and 80 mm to its left – the tap outlet must be positioned at least 300 mm above a draining board or drip tray.
b) The unit is typically connected to 220-240/415V power to the
terminal block within the heater through the rear panel (use the paper mounting template as a guide). The connecting cable must be sufficient power rating for the heater, see table on the left for information. The user accessible wall-mounted power switch must be installed in accordance with wiring rules. It shall provide
Installation Requirements
Model Element Power Connections
15L 1 x 2.4kW
Use single phases power connec­tion. May also be wired to a 15A or 10A GPO respec­tively
25L 1 x 3.6kW
40L 2 x 3kW
2 phases or the same phase applied to the two live connections
- 6kW
all-pole disconnection with a switch contact separation of at least 3 mm (see step 3.3 on page 6).
c) Cold water supply with a minimum working pressure of 70 kPa
and a maximum working pressure of 700 kPa connected via an isolation valve.
d) Outlet drainage to a sink draining board or to a drip tray.
e) Access to drainage from a vent situated at the base of the
heater.
f) If the water pressure is likely to exceed 700 kPa, a 350 kPa
pressure reducing valve must be installed in the cold water supply line.
f) In all installation instances the walls of the heater must be
vertical and the base horizontal, there can be no exceptions to this rule.
Refer to the mounting-hole template on page 19.
Read the installation and operating instructions completely.
Decide whether to install with concealed or exposed plumbing and/ or electrical connections. Concealed connections are preferred for superior appearance.
Step 1 – Positioning
Position the heater so the tap will drain on to a draining board or drip tray.
Position the base of the tap to be not less than 300 mm above the draining board (height should be increased only if essential for filling larger vessels).
Provide clearance for service access of not less than 100 mm top, 150 mm to its right and 80 mm to its left.
Mark corner positions for the heater on the wall so as to position the paper mounting-hole template.
Step 2 – Fastening
Position mounting-hole template on wall and drill holes where shown.
Installation Procedures
COLD INLET
VENT
OUTLET
INLET
POSITION
VENT
POSITION
Approximate Weight When Filled
100 mm minimum clearance
80 mm minimum clearance from left edge to wall
300 mm
150 mm
15 Litre models 34.5 kg
25 Litre models 47 kg
40 Litre models 71 kg
Installation Requirements
805194 09.17 1.02 Page 5 of 24
Concealed
Vent
Concealed
Inlet
45 mm
Remove cover fastening screws from heater and lift whole cover off heater.
Install plumbing and wiring and prepare pipe ends and wiring ends as shown.
Screw heater chassis to the wall using screws or bolts suited to the wall.
Screws or bolts must be capable of supporting the heater weight when filled.
Step 3 – Connecting
THE FOLLOWING PROCEDURE IS TO BE DONE BY AN AUTHORISED INSTALLER ONLY.
3.1 Plumbing
For exposed plumbing connection, connect the cold water inlet pipe from the base of the heater directly to the 12.7 mm compression fittings.
For concealed plumbing connections, connect the cold water pipe through the rear of the chassis using a 12.7 mm capillary elbow (# 63 Swivel Elbows).
Cold water pipes must be flushed before connection to the inlet. Any clogging due to sediment or fines will adversely affect the operation of the heater.
It is recommended that the heater be installed with a stop cock which allows it to be isolated from the mains supply for servicing.
Water pressure requirements:
Minimum - 70 kPa maximum - 700 kPa.
3.2 Venting
A vent at the base of the heater must be plumbed to a safe visible location as, under certain conditions, it may discharge cold or boiling water and/ or steam.
For exposed vent plumbing, connect vent outlet from the base of heater to a 12.7 mm pipe which has a continuous fall, is no more than 3 metres long, has no more than 3 right angle bends, and visibly discharges to a waste water drain.
Alternatively attach a tun dish to the wall as shown and plumb away to waste.
Note: when routing the plumbing for the vent / tundish installed and mains inletline, ensure you do not obstruct filter access for filter replacement.
Visible Tundish
Vent line
Installation Procedures
Warning: If pressure is likely to exceed 700 kPa, a pressure limiting valve must be installed in the cold water supply line. Zip recommends a valve rated at 350 kPa for this application.
3.3 Electrical
Warning: Do not turn on the power until instructed. Water must first be available from the tap outlet to prevent damage.
All wiring must be performed by a qualified electrician.
For concealed electrical connections, connect a power cable from the rear of the heater to the terminal block within the heater as shown, refer to diagrams Fig.1 and Fig.2.
For surface mount installations run the power cable through the cable entry gland at the bottom of the unit to the terminal block within the heater. Ensure the cable is firmly secured.
Thread Tape
2. Ensure su cient thread tape is applied to the thread.
1. Fit the cover to the unit and  x with screws top and bottom.
3. Turn the tap fully clockwise onto the outlet tube until it touches the lock nut and is in an upright position.
4. Use the spanner supplied to tighten the lock nut anti-clockwise.
Lock nut
Step 4 – Installing Tap
Neutral
Earth
Live
Electrical connection for units with 1 element (15L & 25L).
Neutral
Earth
Live Phase 1
Live Phase 2
Electrical connection for units with 2 elements (40L models).
Installation Procedures
Fig.1
Fig.2
805194 09.17 1.02 Page 7 of 24
Installation Procedures
Step 5 – Commissioning - Filter Flush & Calibrate
Warning: Do not turn on the power until instructed. Water must first be available from the tap outlet to prevent damage.
Filter Flush
1) Ensure filter flush valve lever is rotated to down
position, see Fig.3.
2) Turn on the mains water. Allow at least 5 litres of water
to flush through the filter. Make sure there is water flowing from the vent outlet (i.e. the valve setting is correct). Water should not flow into the tank.
3) Once the filter flush is complete, rotate the valve lever
180 (either way) to the “FILTERED” position (Fig.4).
Filling Tank
1) Depress the lever as shown in Fig.4.
2) Open the tap (push the lever backwards) into the locked
open position (Fig.4) and allow the tank to fill until water flows from the tap outlet.
3) Once the water is available from the tap, turn off the
mains water and close the tap outlet.
4) Turn on the power to the unit (water must be in the
tank).
5) Touch the white circle next to the left of the [Tick]
to “Continue”
For screen operation, see the section on “Menu Operation”.
6) Boiling Calibration will commence. It will take several
minutes for the water to boil.
Fig.3
Fig.4
Depress
Inlet water
temp
15°C 10°C
15 Litre models 40 min 43 min
25 Litre models 47 min 50 min
40 Litre models 60 min 64 min
Calibrating Completed
7) When it completes (as prompted), turn on the mains water
supply.
8) Select
to
Continue
9) The home screen will be shown (see section 2.1).
10) The tank will fill and heat. It will take the initial times shown in
the table to reach the final state.
Installation Procedures
805194 09.17 1.02 Page 9 of 24
The Autoboil uses a display and button menu system for setup and operation adjustment.
The display does not have a touch screen feature. The side buttons are used to navigate, perform selections and modify values.
The icon changes according to the button action. A button has no function when no icon is shown.
Menu Operation
1.Understanding Icons and Buttons
Move to the next item able to be highlighted.
Move to the previous item able to be
highlighted.
Confirm menu selection.
Move to the previous menu.
Perform one of 3 functions:
1. Move to the menu titled by the highlighted item.
2. Select the currently highlighted item to adjust it.
3. Confirm the value of a selected item.
Increment the item selected.
Decrement the item selected.
2.Home Screen Content
2.1 Normal Mode
Button 2 shows faults information. Refer to Fault Codes Table for fault information. Button 3 shows more information about the  lter life.
Using to navigate to the  lter life settings menu.
Button 4 will show more information about the sleep mode settings.
Using to navigate to the sleep mode settings menu.
Filter Indication:
Days remaining of  lter life.
Shown red,  lter needs replacement.
Sleep Mode Indication:
Unit will enter sleep mode at the time shown.
Unit will enter sleep mode when it is dark.
All sleep saving modes are disabled.
2.2 Sleep Mode
Trigger Indication:
Unit will exit sleep mode at the time shown.
Unit will exit sleep mode when ambient light returns to normal (bright room).
Menu Operation
Fault Indication:
There are no current faults.
Shown red, there are current faults.
To see fault, press button 2 and refer to fault codes table at the back of this book.
805194 09.17 1.02 Page 11 of 24
3. Settings Menu
Select on the home screen to navigate to the main menu.
Choose
Settings
and select
Choose an option and select
2.3 Sleep Override Mode
Awake time remaining:
Unit will return back to sleep mode after this time.
Main Menu Settings Menu
Menu Operation
3.1 Settings - Date/Time
From the settings menu choose
Settings
and select
g
Navigating using and
Perform a selection or confirm an adjusted value using
Adjust the date/time values using and
Note: Time can be in 12hr or 24hr mode.
To set up time choose a selection, then
Adjust value by using
and then to con rm. Follow similar steps to set up date.
From the settings menu choose
Settings
and select
g
, and to adjust boiling
point.
Confirm using
and return to the previous
menu.
3.2 Settings - Temperature
Note: Setting high temperatures may require boiling calibration to prevent excessive steam release or high energy usage (see section 4.2).
3.3 Settings - Sleep Modes
From the settings menu choose
Sleep Modes
and select
g
Choose
Sleep Trigger
and select , and to select the trigger for the unit to enter its sleep mode. Con rm using
and return to the previous
menu.
Disabled
the unit will not enter its sleep mode.
the unit will use the on/o timer settings to enter and exit its sleep mode.
the unit will enter its sleep mode when darkness is detect­ed and will exit its sleep mode when the ambient light returns to a normal level (bright room).
Timer
Ambient Light
Choose
Sleep Action
and select and to select the heating mode action when the unit is in its sleep mode. Con rm using and return to the previous menu.
3.3.2 Sleep Action
3.3.1 Sleep Trigger
Menu Operation
805194 09.17 1.02 Page 13 of 24
68°C
While the unit is in its sleep mode the set point of the water will be reduced to 68°C.
While the unit is in its sleep mode no heating of the water will occur.
O
Choose
Sleep Action
and select and to select the trigger for the unit to enter its sleep mode.
Con rm using
and return to the previous
menu.
Everyday
Adjust on/o timer settings for all 7 days simultaneously.
Adjust on/o timer settings for all 5 weekdays simultaneously.
Adjust on/o timer settings for the 2 weekend days simultane­ously.
Adjust on/o timer settings for the 7 days separately.
Weekdays
Weekends
Individual Days
3.3.3 Timer Settings
Individual Days Settings
Choose item and adjust value, then
to confirm.
3.4 Settings - Filter
From the settings menu choose
Filter
and select
3.4.1 Internal / External Filters
Choose
Internal
or
External
and select
Choose one of the following options and select
Note: There is a similar set of menus for both internal and external  lters.
Menu Operation
Saving changes
to exit the timer settings menu. A confirmation menu will be shown.
Choose
Continue
to save changes and
to confirm. Choose
Cancel
to
discard changes and
to confirm.
This allows modi cation of  lter life and usage parameters.
Filter Life – Options are:
Disabled (no  lter replacement reminder will be
shown on home screen)
1-14 months (Default 12 months)
Filter Usage – Automatically increments daily. This is reset to “0 Days” when a  lter reset is performed. Can be adjusted if a partially used  lter is inserted.
The days remaining of the  lter shown on this menu and on the home screen are based on these 2 parameters.
This action will reset the  lter usage counter. A re­minder is shown to  ush the new  lter before doing this (see page 21 - Filter Replacement). Select
to continue after  ushing.
Choose
Continue
and select to
reset the  lter usage counter.
The log shows the dates that the  lter usage counter was reset and the “days used” before the reset was performed.
Use
and to scroll through the log history.
3.4.2 Filter Life / Usage
3.4.3 Replace Filter
3.4.2 Filter Log
Select on the home screen to navigate to the main menu.
Choose
Install
and select
4. Install Menu
Menu Operation
805194 09.17 1.02 Page 15 of 24
4.1 Install - Light Calibration
From the install menu choose
Continue
and select
Before continuing ensure the unit is in its normal typical light environment and the front panel is not covered.
Select to perform the calibration. It will com­plete after 6 seconds.
Select
to continue.
4.2 Install - Boiling Calibration
This automatically corrects for boiling point differences at each installation site. The unit was calibrated by the installer at installation; however the installation environment may have changed requiring recalibration of the boiling point.
Incorrect boiling calibration points may cause excessive steam vent releases, or increased energy usage.
From the install menu choose
Continue
and select
The unit will heat the water for boiling calibration. This may take several minutes depending on the initial water temperature. When it completes the screen will automatically return to the install screen.
4.3 Install - Power Cycle
From the install menu choose
Power Cycle
and select
This will turn the unit brie y o then on (restart). All custom settings will be retained.
Choose
Continue
and select to
perform the power cycle.
Menu Operation
5.1 Info - Product
From the install menu choose
Product
5.2 Info - Current Fault
From the info menu choose
Current Fault
6. Service Menu
Note: The service menu is used by technicians only for diagnostic purposes.
Menu Operation
5. Info Menu
Select on the home screen to navigate to the main menu.
Choose
Info
and select
Choose value then select
805194 09.17 1.02 Page 17 of 24
Wall Mounting Template Dimensions
573.00 (10lt, 15lt)
753.00 (25lt)
813.00 (40lt)
40.00
41.00 (10lt, 15lt, 25lt, 40lt)
62.00 (10lt, 15lt, 25lt, 40lt)
84.00 (10lt, 15lt, 25lt, 40lt)
COLD INLET VENT
25.00
333.00
(10lt, 15lt, 25lt)
591.00
(10lt, 15lt)
External Plumbing
Electrical Wiring
Internal Plumbing
499.00
(40lt)
39.50
(10lt, 15lt, 25lt, 40lt)
459.50
(40lt)
145.00
(10lt, 15lt, 25lt)
458.00
(40lt)
10.00
(10lt, 15lt, 25lt, 40lt)
60.00
(10lt, 15lt, 25lt, 40lt)
21.00
(10lt, 15lt, 25lt, 40lt)
103.00
(10lt, 15lt, 25lt, 40lt)
41.00
(10lt, 15lt, 25lt, 40lt)
771.00
(25lt)
334.50
(10lt, 15lt, 25lt)
374.00
(10lt, 15lt, 25lt)
Wall template for 15 litre, 25 litre & 40 litre models.
Spare Parts
Item Kit Number Description
1 93118 Elbow Stem 1/4"
2 94457 Cistern Lid EB & AB
3 94495 Grommet
4 94456 Cistern Gasket
5 94455 Ball Valve Assy
6 94454 Cistern
7 94458 Overload
8 90100
Grommet Cistern to
Tank
9 94460 Seal Transfer Tube
10 90494
Metering Tube 2.4kW
Element 15lt
10 90527
Metering Tube 3.6kW
Element 25lt
10 90526
Metering Tube 2 x
3.0kW Element 40lt
11 94609 4 Pole Contactor 40lt
11 90174 3 Pole Contactor 25lt
12 94610 PCB Heatsink Assy
13 94491 Filter Flush Valve
14 94611 Ribbon Cable
15 94459 Side Release Plug
16 94492
Filter Head Kit (no
bracket)
17 94612 Mains Inlet Assy
18 93704 0.2 mic Zip Filter Size 2
19 94613 Steam Sensor NTC
Item Kit Number Description
20 90501 Tap Top Assy 21 93730 Flow Insert 22 94478 Tap Body 23 94448 Tap Lock Nut 24 94447 Escutcheon 25 94479 AB Fascia & PCB Assy 26 91440 Hot Tank NTC 27 90492 Drain Cap & Seal Kit 28 90491 Cleaning Hole Cover Kit 29 94614 2.4kW Element 15lt 29 94615 3.6kW Element 25lt 29 94616 3.0kW Element 40lt
29 94617 3.6kW/380 Element 25lt
29 94618 3.0kW/415 Element 40lt
30 94471 Cistern Gasket Kit 31 94472 Cistern Assy 32 94470 Tap Assy 33 94619 Vent Bush Assy 34 94620 Tank Assy 40lt 34 94621 Tank Assy 25lt 34 94622 Tank Assy 15lt 35 94623 Tap Outlet Assy
36 94624 Loom PCB to Overload
37 94625
Loom Contactor to
Overload
38 94626 Loom PCB to Terminal
805194 09.17 1.02 Page 19 of 24
Exploded View Diagram































Problem Solving
Symptom Possible Cause Solution
Fails to dispense water.
Incorrect filter flush valve setting.
Incorrect filter insertion.
Water isolating valve turned off.
Blocked filter, blocked meter tube,
blocked strainer, jammed ball
valve assembly.
Check filter flush valve position
(see Step 5, page 7).
Check filter is inserted correctly
(see page 21).
Check water supply valve.
Contact Zip authorised agent.
Water not boiling.
Incorrect temperature setting.
Incorrect sleep mode setting.
No power.
Faulty thermostat, faulty element,
faulty cutout.
Check temperature setting
(see section 3.2).
Check sleep mode settings (see
section 3.3) or reset settings from
service menu.
Check power supply.
Contact Zip authorised agent.
Runs out of boiling water and
fails to refill.
Outlet tap drips.
Overflow from vent.
Excessive steam from vent.
Power “on” but no heat.
Overload repeatedly tripping
with excessive steam.
Overload repeatedly tripping
without
excessive steam.
Requires boiling calibration.
Incorrect filter flush valve setting.
Incorrect filter insertion.
Internal adjustment.
Perform boiling calibration
(see section 4.2).
Check filter flush valve position
(see Step 7, page 8).
Check filter is inserted correctly
(see page 21).
Contact Zip authorised agent.
Sleep/Wakes incorrectly when
room is light/dark.
Requires light calibration.
Incorrect sleep modes settings.
Perform light calibration
(see section 4.1).
Check sleep mode settings (see
section 3.3) or reset settings from
service menu.
805194 09.17 1.02 Page 21 of 24
Warning: this appliance must be earthed.
Following remedial service the earthing continuity of the heater must be checked by a qualified technician using an appliance tester, or continuity tester of accuracy Class 5 or better. Class 5 denotes an accuracy of 5% full scale deflection.
1. Isolate power supply.
2. Set meter to 0 ohm with leads connected together.
3. Connect one test lead to the earth pin on the three pin plug.
4. Connect the other test lead to a bare patch of metal (preferably on the edge) of the top of the cover, then to the front cover of the unit, and then to the tap.
Warning- the water may be boiling - show extra care.
5. Test that in every instance the electrical resistance does not exceed 1 ohm.
Earthing Continuity Verification
If required, an earth continuity test can be performed by testing between the earth pin on the products lead and a exposed piece of metal on the case and the tap body.
Error Code Error meaning Solutions
0 Boiling sensor is open circuit Call Zip Service
1 Boiling sensor has a short circuit Call Zip Service
2 Steam Sensor is open circuit Call Zip Service
3 Steam sensor has a short circuit Call Zip Service
4 Calibration error !! Call Zip Service
5
Boiling calibration error, insu cient steam temperature when boiling sensor registered over 90°c
Call Zip Service
6
Max temp error. The maximum temperature reached is lower than 92°c during the calibration process.
Check your height above sea level. Call Zip Service.
7
Over temp error. A constant temperature over 103°C has been reached during the calibration process.
Make sure there is an airgap in the vent line. Call Zip service.
8
Calibration error, water temperature is falling or constant when maximum element power is applied.
When water runs from the outlet tap turn water supply o to unit. Restart calibration.
Fault Codes Table
1. Turn the  lter anti-clockwise.
NOTE: For safe operation, the filter cartridge should be replaced every 6-12 months, or earlier if you notice a persistent reduction in water pressure from the appliance or an unpleasant taste or odour in the water.
To Replace Filter:
• Turn the filter anti-clockwise (fig.1) and pull the cartridge down (fig.2). Have an absorbent cloth ready as a small amount of water will be released as the filter is removed. The cartridge should release from the filter head.
• Replace with a new filter by gently pushing up, engaging the key and turning the filter clockwise until the filter clicks or locks into place.
• Perform filter flush by following the filter flush steps on page 7 (Step 7 - Commissioning).
• Go to [Replace Filter] screen to
reset the  lter usage counter. Follow the instructions on page 14 (3.4.3 Replace Filter) section for details of menu operation.
Warning! Not changing filtration cartridges when required, may cause the water to become biologically unsafe.
If the Zip Autoboil is switched off for a long period of time (e.g. More than a weekend), run water through the outlet for at least 5 minutes before consumption.
Filter Replacement
Fig.1
2. Remove the  lter by gently pulling down.
Fig.2
Operating Procedures
Tap Operation
Boiling water
Zip Autoboil is fitted with a two-way tap for filtered instant boiling water.
For instant boiling water, gently pull the top of the tap forward.
Boiling water will flow until the tap handle is released.
This operation gives fingertip flow control for safe filling of cups and mugs.
To fill larger vessels such as teapots and saucepans, rotate the tap 180 degrees and depress it until it locks into a horizontal position.
Boiling water will flow until the tap is returned to its normal vertical position. This operation allows the vessel to be filled without holding your hand where it may be affected by steam.
805194 09.17 1.02 Page 23 of 24
End of life disposal
In order to help preserve our environment we ask that you dispose of this product correctly. Please contact your local city council for collection centre details.
Cleaning
Cleaning Case
Do not use strong, corrosive, spray or abrasive cleaners. Clean the case with a soft cloth or sponge and mild soapy water.
Dispose of the filter cartridge responsibly.
Use only Zip Filter in this product to ensure effective filtration and operation. Replacement filter cartridges can be obtained through plumbing suppliers or directly from Zip.
Filter replacement instructions are included with the filter cartridge spare part kits.
Filter Replacement
Contact Details
This user manual has been written according to application firmware version 1.2. Please check the following website for the latest user manual: https://www.zipwater.com/
Head Office
Zip Heaters (Aust) Pty. Ltd. ABN 46 000 578 727 67-77 Allingham Street Condell Park NSW 2200 Postal: Locked Bag 80 Bankstown 1885 Australia
Website: www.zipwater.com Telephone (02) 9796 3100 Free Call 1 800 638 633
As Zip policy is one of continuous product improvement, changes to speci cations may be made without prior notice. Images in this booklet have been modi ed and may not be true representations of the  nished goods.
The standard cup referred to in this publication is 167 ml (6  oz).
 © 2017 Zip Heaters (AUST) Pty. Ltd. All Rights Reserved.
The terms “Zip”, “Autoboil”, “Power-Pulse”, “GlobalPlus”, “MicroPurity” are trade­marks of Zip Heaters (AUST) Pty Ltd.
Products described in this publication are manufactured under one or more pat­ents and further patent applications are pending.
One or more products described in this publication are also registered designs of Zip Heaters (AUST) Pty Ltd.
Loading...