Read These Warnings First
Finished height will vary due to adjustable feet (Chillmaster only). The average height for the centre line of the plumbing services is 790 mm.
Place the unit on a level floor and screw the feet in or out as appropriate to make the unit level and steady (Chillmaster only), see Fig.1.
Leave at least a 50 mm gap between the sides of the unit and any walls, to allow air flow through the vents.
The rear of the unit can be flush mounted against the surface of a wall if the plumbing permits.
Connect only to cold water 10-38°C with a pressure range of 70 kPa - 700 kPa.
• Please read all installation requirements, installation procedures and precautions before installing any Zip Chillmaster/Sitemaster/Economaster.
• Never attempt to install any Zip Chillmaster/Sitemaster/Economaster without reading all of the applicable instructions.
• All electrical connections must comply with current wiring rules.
• These appliances ares not intended for use by persons (Including Children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliances by a person responsible for their safety.
• Children should be supervised to ensure they do not play with the appliances
• This appliance must be earthed.
• If the power supply cord is damaged it must be replaced by a Zip Service Provider or a qualified electrician.
• The power cord and GPO must be in a safe and accessible position after installation
• Do not remove the cover of the appliance under any circumstances without first isolating the appliance from the power supply.
• The units are for indoor use only and must not be exposed to the elements of nature.
• These units must not be positioned in an area that may be cleaned by a water jet and must not be cleaned by a water jet.
Chillmaster only
Installation Instructions
Fig.1
105
170
81507 - Zip Freestanding Chilled Water Systems - Installation & Operating Instructions - April 2015 v2.03 Page 3 of 8
Zip Sitemaster and Economaster
It is the installers responsibility to ensure the installation complies with AS/NZS3500.1, AS/NZS3500.2, AS/NZS3500.4.1, AS/NZS3500.4.2 and local water authority regulations.
Minimum operating pressure is 172 kPa. Where pressure may exceed 700 kPa, a pressure limiting valve must be installed.
No valves are supplied with the product. All necessary valves must be supplied separately by the installer.
Connect a cold water supply to the half inch BSP female inlet at the back of the chiller where shown in the diagram on page 3.
Connect a drain to the 40mm PVC female outlet at the back.
Purge the air from the unit when the plumbing connections are complete, by turning ‘on’ the water supply, and pressing the button on the bubbler, until the water flows through without spluttering. Check connections for leaks and repair any found.
Zip Chillmaster
Connect a cold water supply to the half inch BSP female inlet at the back of the chiller where shown in the diagram.
Connect a drain to the 40 mm PVC female outlet at the back.
Alternatively, there are pre-punched holes in the base of the Chillmaster for bottom access to plumbing services.
All valves necessary for use with the Chillmaster are already fitted within the unit. This appliance incorporates backflow protection complying with AS3500.1. No further backflow protection is required for connection to the water supply. A special surge protection system is totally self contained within the Chillmaster, to protect it from damage.
DO NOT ADJUST, ALTER OR REMOVE THE VALVE ASSEMBLY.
Purge the air from the unit when the plumbing connections are complete by turning ‘ON’ the water supply and pressing the button on the bubbler until the water flows through without spluttering.
Electrical
A 1.8m flexible cable and 240v 50 Hz 3 pin plug are fitted. Run the cable out of harm’s way and plug it into a standard power point.
Do not turn the power point ‘on’ until the unit is purged.
Installation Instructions continued
Operating Procedures
Fig.2
Operating the Bubbler (All models)
Chilled water is obtained momentarily by pressing the bubbler button, see Fig.2.
The water is chilled by a refrigeration unit fitted within the cabinet stand, under the basin.