Zip 04052 Zip Autoboil 40 Litre White, 11051 Zip Autoboil 15 Litre Stainless Steel, 11052 Zip Autoboil 15 Litre White, 04051 Zip Autoboil 40 Litre Stainless Steel, 12052 Zip Autoboil 25 Litre White Installation & Operating Instructions Manual

...
Zip Autoboil - Installation & Operating Instructions - 81439 - May 2012 v1.02 Page 1 of 12
Installation and Operating Instructions
Zip Autoboil
Instant boiling water
11052 Zip Autoboil 15 Litre White
11051 Zip Autoboil 15 Litre Stainless Steel
12052 Zip Autoboil 25 Litre White
12051 Zip Autoboil 25 Litre Stainless Steel
04052 Zip Autoboil 40 Litre White
04051 Zip Autoboil 40 Litre Stainless Steel
Intentionally left blank.
Zip Autoboil - Installation & Operating Instructions - 81439 - May 2012 v1.02 Page 3 of 12
Contents
Read These Warnings First . . . . . . . . . . . . . . 4
Installation Requirements . . . . . . . . . . . . . . . 4
Installation Procedures . . . . . . . . . . . . . . . . . 5
Step 1 – Positioning. . . . . . . . 5
Step 2 – Fastening. . . . . . . . . 5
Step 3 – Connecting . . . . . . . 6
a) Plumbing . . . . . . . .6
b) Venting. . . . . . . . . .6
c ) Electrical . . . . . . . .6
Step 4 – Assembling . . . . . . . 6
Step 5 – Commissioning . . . . 6
Wall Mounting Template Dimensions . . . . . . 7
Problem Solving. . . . . . . . . . . . . . . . . . . . . . . 8
Earthing Continuity Verification . . . . . . . . . . . 8
Operating Procedures . . . . . . . . . . . . . . . . . . 9
End of life disposal . . . . . . . . . . . . . . . . . . . . 9
Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Contact Details . . . . . . . . . . . . . . . . . . . . . . . 12
Read These Warnings First
Please read all installation requirements, installation procedures and precautions before installing any Zip Autoboil instant boiling water heater.
Never attempt to install any Zip Autoboil instant boiling water heater without reading all of the applicable instructions.
In some hard water areas where mineral scale accumulation in the boiling chamber of the Zip Autoboil may become a problem, consideration should be given to the maintenance required. A suitable form of water treatment may be necessary.
The cold water supply to this appliance must be portable and fall within your local authority’s guidelines.
All plumbing connections must be made in accordance with local regulations.
The Zip Autoboil instant boiling water heater is not intended for use by young children or infirm people without supervision.
Young children should be prevented from having access to ensure that they are not able to use or play with the heater.
If the installation site is located more than 1000 metres above sea level, the installer should contact a Zip authorised agent for high altitude settings.
This appliance must be earthed. If the power supply cord is damaged it must be replaced by a Zip authorised agent or a qualified electrician.
Do not remove the cover of the heater under any circumstances without first isolating the heater from the power supply.
Do not use strong, corrosive or abrasive cleaners to clean the case of the heater.
Frost protection: If this heater is located where ambient air temperature could fall below 5ºC when the heater is not in use, do not turn off the appliance electrically. This safeguard does not offer the same protection to the connecting pipework and fittings.
The ambient temperatures this unit should operate with is 5ºC - 50ºC.
This heater is intended only for indoor use and should never be installed outdoors or be exposed to the elements of nature.
This unit must not be positioned in an area that may be cleaned by a water jet. This unit must not be cleaned by a water jet.
Before installing, ensure that the following are available:
a) Sufficient space to position the heater so there is at least 150 mm clearance above the
heater for service access, 65 mm to its left and 20 mm to its right – the tap outlet usually should be positioned at least 200 mm above a draining board or drip tray.
b) Standard local requirement power cable positioned as shown on the paper mounting
template for connection from the rear of the heater to the terminal block within the heater, OR a standard power outlet that will adequately cater for the unit’s power needs on the wall within 1500 mm of the heater. For units with 3.6 Kw element (25 ltr) or multi element units (40 ltr) an isolating switch in the fixed wiring and attached to a secure surface is required. This switch must provide all-pole disconnection and a contact seperation of at least 3 mm installed in accordance with wiring rules.
c) Cold water supply with a minimum working pressure of 100 kPa and a maximum
working pressure of 700 kPa connected via an isolation valve.