Zinwave 302-0007 Users Manual

Zinwave 3000
Distributed Antenna System
User Guide
3000_DAS_UG_v1.10
© Zinwave Ltd. 2008
No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Zinwave Ltd. as governed by United Kingdom and international copyright laws.

Edition

Issue 3000_DAS_UG_v1.10, October 2008

Warranty

The material contained in this document is provided “as is,” and is subject to being changed, without notice, in future editions. Further, to the maximum extent permitted by applicable law, Zinwave disclaims all warranties, either express or implied, with regard to this manual and any information contained herein, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Zinwave shall not be liable for errors or for incidental or consequential damages in connection with the furnishing, use, or performance of this document or of any information contained herein. Should Zinwave and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms, the warranty terms in the separate agreement shall control.

Technology licenses

The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license.

Trademark acknowledgements

Pentium ® is a registered trademark of Intel Corporation. Adobe ® is a trademark of Adobe Systems Incorporated. Windows XP, Windows 2000, and Windows 98 are U.S. registered trademarks of Microsoft Corporation. Macintosh is a trademark of Apple Computer. Linux is a trademark of Linus Torvalds. All other trademarks are the property of their respective holders.

About this guide

This guide contains hardware installation and software configuration & operating instructions for the Zinwave 3000 Distributed Antenna System (DAS).
Warning : A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met.
Caution: A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met.
2 Zinwave 3000 DAS User Guide

Safety notices

Cautions and warnings

Caution: This unit is fitted with a 5A 20x5mm anti-surge ceramic fuse (RC). For continued protection against risk of fire, replace only with same type and rating of fuse. Keep all product information for future reference.
Warning : High voltages exist inside the product; Do not remove the lid or base: No user serviceable parts inside.
Warning : If this product is not used as specified, the protection provided by the equipment could be impaired. This product must be used in a normal condition (in which all means for protection is intact) only. No operator serviceable parts are inside this system. Refer servicing to an authorized Zinwave Ltd service centre. To prevent electrical shock, do not remove the covers.

Notes

Read this User Manual and follow all operating and safety instructions.
Position the power cord to avoid possible damage; do not overload wall outlets.
Do not place this product on or near a direct heat source, and avoid placing objects on
the terminal.
Do not operate this device near water or in a wet location.
Use only a damp cloth for cleaning. Do not use liquid or aerosol cleaners. Disconnect
the power before cleaning.
Installation of the 3000 DAS system must be contracted to a suitably trained and
competent professional installer.

Declaration of Conformity

Hereby, Zinwave Ltd, declares that this Distributed Antenna System is in compliance
with the essential requirements and other relevant provisions of Directive 1999/5/EC.
Zinwave Ltd, vakuuttaa täten että Distributed Antenna System tyyppinen laite on
direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen.
Hierbij verklaart Zinwave Ltd, dat het toestel Distributed Antenna System in
overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG
Bij deze verklaart Zinwave Ltd, dat deze Distributed Antenna System voldoet aan de
essentiële eisen en aan de overige relevante bepalingen van Richtlijn 1999/5/EC.
Par la présente, Zinwave Ltd, déclare que ce Distributed Antenna System est conforme
aux exigences essentielles et aux autres dispositions de la directive 1999/5/CE qui lui sont applicables
Härmed intygar Zinwave Ltd, att denna Distributed Antenna System står I
överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG.
Undertegnede Zinwave Ltd, erklærer herved, at følgende udstyr Distributed Antenna
System overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF
3
Hiermit erklärt Zinwave Ltd., dass sich dieser Distributed Antenna System in
Übereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten Vorschriften der Richtlinie 1999/5/EG befindet
ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ Zinwave Ltd, ΔΗΛΩΝΕΙ ΟΤΙ Distributed Antenna System
ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥ ΣΙ ΩΔ ΕΙ Σ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙ ΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗ ΓΙΑΣ 1999/5/ΕΚ
Con la presente Zinwave Ltd, dichiara che questo Distributed Antenna System è
conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE.
Por medio de la presente Zinwave Ltd, declara que el Distributed Antenna System
cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE
Zinwave Ltd, declara que este Distributed Antenna System está conforme com os
requisitos essenciais e outras disposições da Directiva 1999/5/CE.

Optical Remote Unit interference

Warning : This is a class A product (as defined in EN 55022). In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures.

FCC compliance and interference statements

Hub. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
1) This device must accept any interference and
2) This device must accept any interference received including interference that may cause undesired operation
Changes or modifications not expressly approved by Zinwave Ltd. could void the user’s authority to operate the equipment.
Remote Unit. This device complies with Part 22, Part 24, Part 27 and Part 90 of the FCC rules. Changes or modifications not expressly approved by Zinwave Ltd. could void the user’s authority to operate the equipment. For a list of services, please contact Zinwave.
Remote Units with FCC ID:UPO302-0007 only supports services in the following bands of operation:
406.1 – 454.0 MHz
456.0 – 512.0 MHz
698.0 – 824.0 MHz
851.0 – 869.0 MHz
869.0 – 894.0 MHz
928.0 – 929.0 MHz
931.0 – 935.0 MHz
935.0 – 940.0 MHz
1930.0 – 1990.0 MHz
2110.0 – 2155.0 MHz
4 Zinwave 3000 DAS User Guide

Rack mount instructions

Caution: Double Pole/Neutral Fusing.
Elevated Operating Ambient – If installed in a closed or multi-unit rack assembly, the
operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturers. 3000 DAS Primary and Secondary Hubs have a Tma of 45°C.
Reduced Air Flow – Installation of the equipment in a rack should be such that the
amount of air flow required for safe operation of the equipment is not compromised.
Mechanical Loading – Mounting of the equipment in the rack should be such that a
hazardous condition is not achieved due to uneven mechanical loading.
Circuit Overloading – Consideration should be given to the connection of the equipment
to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
Reliable Earthing – Reliable earthing of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips).
Disconnect Device – The socket outlet shall be installed near the equipment, be easily
accessible and will act as the disconnect for the Hub.
Keep these Instructions in a safe place.
5

General safety considerations

The installation of electrical supplies in support of Zinwave 3000 DAS products shall be in accordance with national and local regulations.
Other aspects of the installation of Zinwave 3000 DAS products and interconnecting cabling shall be in accordance with the following standards:
EN 50174 series: Information technology – Cabling installation
IEC 60825-2: Safety of laser products – Part 2: Safety of optical fibre communication
systems (OFCS)
This equipment complies with 21CFR1040 - Performance Standards For Light-Emitting
Products (FDA).

RF exposure

Warning : This equipment complies with FCC radiation exposure limits set forth for an occupational/ controlled environment. This equipment should be operated with a minimum distance of 20cm between radiator and your body.

Optical Safety Precautions

Do not remove the Fibre Port dust covers unless the port is in use. Do not stare
directly into a Fibre Port.
Cover any unconnected fibre ends with an approved cap.
Do not stare with unprotected eyes at any broken ends of the fibre.
Use only approved methods for cleaning optical fibre connectors.
Do not make any unauthorized modifications to this fibre optical system.
No warning signs are required as it is a Class 1 hazard.
Use Class 1 test equipment.
Warning : Use of controls or adjustments or performance of procedures other than those
specified herein may result in hazardous radiation exposure.
6 Zinwave 3000 DAS User Guide

Installation, use and storage

The Zinwave 3000 DAS is designed to operate in conditions conformant with Pollution Degree 2 as defined in IEC 60950 (the normal environmental class for offices).
The installation of sub-assemblies into the main units of the Zinwave 3000 DAS shall only be undertaken if precautions required by IEC/TS 61340-5-1 have been taken.
This covers the installation of Zinwave Optical Link modules into the Zinwave 3000 DAS Hub Unit.
Warning : CLASS I PLUGGABLE EQUIPMENT TYPE A as defined in IEC 60950. This equipment is intended for connection to other equipment or a network, relies on connection to protective earth and must be connected to an earthed mains socket-outlet. Country specific warnings: Finland "Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan" Norway “Apparatet må tilkoples jordet stikkontakt” Sweden "Apparaten skall anslutas till jordat uttag"
Caution: Unit operating voltage is factory set at either 120V or 230V and cannot be changed by an operator. Check which variant is supplied and only operate at the rated voltage.

Signal and input power

Caution: The input power to the 3000 DAS Hub Unit should not exceed +10dBm. Power levels greater than +25dBm will damage the unit
Caution: The input power to the Zinwave Remote Unit should not exceed -10dBm. Power levels greater than 0dBm will damage the unit
Caution: The total broadband composite output power is limited to +18dBm in Europe and +20dBm in the USA and Canada. The maximum allowed EIRP in the USA & Canada is +28dBm which corresponds to an antenna gain of 8dBi. Contact Zinwave for the maximum output power in other regions.
Caution: The maximum allowed antenna gain when operating in Europe in the 2.4GHz ISM band shall be +2dBi. Contact Zinwave for further information regarding use of the ISM band in other regions.
7
8 Zinwave 3000 DAS User Guide

Table of Contents

Safety notices 3 General safety considera tio n s 6 Optical Safety Precautions 6 Installation, use and storage 7 Signal and input power 7
1 System Description . . . . . . . . . . . . . . . . . . . . . . . 11
1.1 Key features 12
1.2 Multimode fibre technology 12
1.3 System architecture 12
2 Hardware Installation . . . . . . . . . . . . . . . . . . . . . 13
2.1 Overview 14
2.2 Installing the Primary Hub 16
2.3 Installing the Secondary Hub 18
2.4 Installing Remote Units and A n ten n as 19
2.5 Making the signal connections 21
2.6 Connecting service inputs 22
3 Configuration and Control . . . . . . . . . . . . . . . . . 23
3.1 Overview 24
3.2 Before you start 24
3.3 Initial Hub configuratio n 25
3.4 Detailed Hub configuration 28
Zinwave 3000 DAS User Guide 9
10 Zinwave 3000 DAS User Guide
Loading...
+ 22 hidden pages