ZIMO MX697, MX695KS, MX695LS, MX695LV, MX696S Instruction Manual

...
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 1
EDITION
2011 05 01 2011 08 15
SW-Version 31 --- 2012 08 15
Including the new MX696 decoder --- 2012 11 30
SW-Version 33.0 --- 2013 04 30
with chapter about loco boards --- 2013 05 20
2014 10 12
2015 06 01 2015 07 07 2015 09 23 2018 04 20 2019 05 16
Instruction Manual
LARGE-SCALE DECODER WITH & W/O SOUND
and: Combinations of loco boards and decoder MX696KS, MX696KV
MX695KV, -KS, -LV, LS
MX696V, -S
MX697V, -S
MX699KV, -KS, -LV, -LM
1 Product - Overview .................................................................................................. 2
2 Technical Information ............................................................................................... 4
3 Installation and Wiring ............................................................................................. 5
4 Loco Adapter Boards for Large-Scale Decoder ...................................................... 12
5 Configuration ........................................................................................................ 18
5.1 Programming in “Service mode” (on the progr. track) ............................................................. 18
5.2 Programming in “Operations mode” (on-the-main) .................................................................. 18
5.3 Decoder-ID, Load-Code, Decoder-Type and SW-Version ...................................................... 19
5.4 Engine address(es) in DCC mode ........................................................................................... 19
5.5 Analog operation ...................................................................................................................... 20
5.6 Motor control and regulation .................................................................................................... 21
5.7 Acceleration and Deceleration: ................................................................................................ 24
5.8 Special Operating Mode “km/h – speed regulation ................................................................ 25
5.9 The ZIMO “signal controlled speed influence” (HLU) .............................................................. 26
5.10 “Asymmetrical DCC-Signal” stops (Lenz ABC)........................................................................ 26
5.11 DC Brake Sections (Märklin brake mode) ............................................................................... 27
5.12 Distance Controlled Stopping - Constant Stopping Distance ................................................. 27
5.13 Shunting, Half-Speed and MAN Functions .............................................................................. 28
5.14 The NMRA-DCC function mapping .......................................................................................... 29
5.15 The extended ZIMO Function mapping ................................................................................... 30
5.16 “Unilateral Light Suppression” .................................................................................................. 31
5.17 The “Swiss Mapping” (from SW version 32) ............................................................................ 32
5.18 The ZIMO “Input-Mapping“ SW versions 34 and up, also for outputs via SUSI ...................... 34
5.19 Dimming, Low beam and Direction Bits ................................................................................... 34
5.20 Flasher Effect ........................................................................................................................... 35
5.21 F1-Pulse Chains (Only for old LGB products) ......................................................................... 35
5.22 Special Effects (US and other light effects, smoke generator, uncouplers etc.) ..................... 36
5.23 Configuration of smoke generators .......................................................................................... 37
5.24 Configuration of Electric Uncouplers........................................................................................ 38
5.25 Servo Configuration ................................................................................................................. 40
6 Feedback – Bidirectional communication ............................................................... 41
7 ZIMO SOUND – Selection and Programming ......................................................... 42
7.1 The “CV #300 procedures”....................................................................................................... 43
7.2 “Incremental Programming” of sound CV’s, an alternative to “normal” programming ............. 46
7.3 The test run for determining the motor’s basic load ................................................................ 46
7.4 Basic settings independent of powertrain ................................................................................ 47
7.5 Steam engine Basic sound settings .................................................................................... 49
7.6 Steam engine Load and acceleration dependency ............................................................. 51
7.7 Diesel and Electric engines ..................................................................................................... 53
7.8 Random and Switch input sounds ........................................................................................... 56
8 CV – Summery List ................................................................................................ 57
9 Service Insructions................................................................................................. 60
ZIMO decoders contain a microprocessor with appropriate software. The software version can be read out from CV #7 and #65. The current version may not yet capable of all the functions mentioned in this manual. As with other computer programs, it is also not possible for the manufacturer to thoroughly test this software with all the possible applications. Installing new software ver­sions later can add new functions or correct recognized errors. SW updates can be done by the end user for all ZIMO decoders since production date October 2004, see chapter “Software Update”! Software updates are available at no charge if performed by the end user (except for the purchase of a programming module); Updates and/or upgrades performed by ZIMO are not consid­ered a warranty issue and are at the expense of the customer. The warranty covers hardware damage exclusively, provided such damage is not caused by the user or other equipment connected to the decoder. For update versions, see www.zimo.at.
Page 2 Large-scale Decoder & Sound Decoder MX695/6/7/9
MX695K …
Sound-Decoder (and non-sound decoder) with screw terminals
MX695KV
MX695KS
Full version: 36 Screw terminals 14 Function outputs (including headlights) 1 Special output for smoke generator fan 3 Low-voltage outputs: 5 V, 10 V, variable 4 Servo outputs (3-pin plugs: Control, ground, + 5 V) 2 Pot-meters (for volume and low voltage settings) 1 Connection for external capacitor 1 Speaker connection (4 or 8 Ohm at 10 Watt)
Reduced 28 Screw terminals (2 x 12 and 1 x 4) version: 8 Function outputs (including headlights) 1 Special smoke fan output 1 Low-voltage function output: 10 V 1 Connection for external capacitor 1 Speaker connection (4 or 8 Ohm at 10 Watt)
MX695KN
Non-Sound-Decoder with screw terminals
32 Screw terminals (1 x 8 and 2 x 12) 14 Function outputs (including headlights) 1 Special smoke fan output 3 Low-voltage outputs: 5V, 10V, variable 4 Servo outputs (3-pin plugs: control, ground, + 5 V)
MX695L …
Sound-Decoder with pin connectors
MX695LV
MX695LS
Full Version: 3 Pin connectors, 12-pins each 14 Function outputs (including headlights) 1 Special output for smoke generator fan 3 Low-voltage outputs: 5 V, 10 V, variable 4 Servo outputs (3-pin plugs: control, ground, + 5 V) 2 Potentiometers (volume, low voltage adjustment) 1 Connection for external capacitor 1 Speaker connection (4 or 8 Ohm at 10 Watt)
Reduced: 2 Pin connectors, 12-pins ea. (matching ESU-interface) Version 1 Special output for smoke generator fan 1 4-pin socket for additional connections 8 Function outputs (including headlights) 1 Low voltage output: 10 V 1 Connection for external capacitor 1 Speaker connection (4 or 8 Ohm at 10 Watt)
MX696…
Sound and NON-Sound Decoder with narrow body style
MX696V
MX696S
Full Version: 2 20-pin connectors 14 Function-outputs (including headlights) 1 Special smoke fan output 2 Low-voltage outputs: 10V and variable * 4 Servo outputs (control lines) 1 Speaker connection (4 or 8 Ohm at 10 Watt)
Reduced: 1 20-pin connector & 1 10-pin connector 1 Low-voltage function output: 10V 8 Function-outputs (including headlights) 1 Speaker connection (4 or 8 Ohm at 10 Watt)
MX696N
Non-Sound-Decoder, identical size and connections as the MX69
1 20-pin connector 8 Function outputs (including headlights) 1 Low-voltage output: 6 V (Servo supply!) 4 Servo outputs (Control lines)
1 Product - Overview
The MX695 large-scale decoder is available in 5 standard versions, 4 of them are equipped with sound. Special versions for specific high-volume applications with slightly modified features are also available (i.e. customized number of outputs for a specific project).
ZIMO decoders primarily operate in the NMRA-DCC data format with any NMRA-DCC compat­ible system, as well as the MOTOROLA protocol (MM) within Märklin systems and other MOTOROLA command stations. ZIMO decoders also operate in DC analog mode with DC power packs (including PWM) as well as AC analog (Märklin Transformers with over-voltage pulses for direction change).
In addition to the types presented below, there are also loco-board and large-scale decoder combinations available: see chapter 4
51 x 40 x 13 mm
51 x 40 x 13 mm
55 x 29 x 16 mm
*) ATTENTION: The sound decoder MX696V does not have a fixed 5V output (as does the MX695KV/MX695LV), but the variable output can be set between 5 – 6V to supply servos with power.
OR: Use the MX696KV (MX696V combined with LOKPL96KV board), which does have a fixed 5V output.
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 3
MX696K…
Narrow large-scale sound decoder with screw terminals (Decoder and loco board combinations)
MX696KV
MX696KS
MX696KS
Full Version: 30 Screw terminals 14 Function outputs (including headlights) 1 Special smoke fan output 2 Low-voltage outputs: 5 V, variable 4 Servo outputs (3-pin plugs: Control, ground, + 5 V) 1 Potentiometers (for low voltage outputs) 1 Connection for external capacitor 1 Speaker connection (4 or 8 Ohm at 10 Watt)
Reduced 20 Screw terminals Version: 8 Function outputs (including headlights) 1 Special smoke fan output 4 Servo control outputs on solder pads (no 5 V supply) 1 Connection for external capacitor 1 Speaker connection (4 or 8 Ohm at 10 Watt)
MX697
Large-scale sound decoder for US interfaces (Bachmann, Aristocraft)
MX697V
MX697S
Full Version: 2 12-pin connectors 10 Function outputs (including headlights) 1 Special smoke fan output 3 Low-voltage outputs: 5 V, 10V, variable 4 Servo outputs (3-pin plugs: Control, ground, + 5 V) 1 Connection for external capacitor 1 Speaker connection (4 or 8 Ohm at 10 Watt)
Reduced 2 12-pin connectors Version: 10 Function outputs (including headlights) 1 Special smoke fan output 1 Low-voltage output: 10V 4 Servo control outputs (no 5 V supply) 1 Connection for external capacitor 1 Speaker connection (4 or 8 Ohm at 10 Watt)
MX699K …
Large-scale sound decoder with screw terminals
MX699KV
MX699KS
Full Version: 38 Screw terminals 15 Function outputs (including headlights) 2 Special smoke fan output 3 Low-voltage outputs: 5 V,10 V, variable 1 Low-voltage switch (4 fixed values) 4 Servo outputs (3-pin plugs: Control, ground, + 5 V) 1 Speaker connection (4 or 8 Ohm, 10 Watt) 1 Connection for external volume control 3 Internal super caps (total 1F/8V) 1 Additional connection for external capacitor module
Reduced 30 Screw terminals Version: 8 Function outputs (including headlights) 1 Special smoke fan output 3 Low-voltage outputs: 5 V,10 V, variable 4 Servo control outputs on solder pads (no 5 V supply) 1 Speaker connection (4 or 8 Ohm at 10 Watt) 1 Connection for external volume control 3 Internal super caps (total 1F/8V) 1 Additional connection for external capacitor module
1
MX699L …
Large-scale sound decoder with pin connectors
MX699LV, -LM
-LM: Direct fit for the 2 x 14 – pin Märklin in­terface with extra pins on top
MX699LS
-LS: Direct fit for the 2 x 14 – pin Märklin in­terface
Full Version: 3 14-pin connectors 15 Function outputs (including headlights) 1 Special smoke fan output 3 Low-voltage outputs: 5 V,10 V, variable 1 Low-voltage switch (4 fixed values) 4 Servo outputs (3-pin plugs: Control, ground, + 5 V) 1 Speaker connection (4 or 8 Ohm, 10 Watt) 1 Connection for external volume control 3 Internal super caps (total 1F/8V) 1 Additional connection for external capacitor module
Reduced 2 14-pin connectors Version: 8 Function outputs (including headlights) 1 Special smoke fan output 3 Low-voltage outputs: 5 V,10 V, variable 4 Servo outputs (3-pin plugs: Control, ground, + 5 V) 1 Speaker connection (4 or 8 Ohm, 10 Watt) 1 Connection for external volume control 3 Internal super caps (total 1F/8V) 1 Additional connection for external capacitor module
Note to the Märklin interface: one of the female terminals on the vehicle decoder board may be used as a key to pre­vent a wrong installation and may therefore be plugged. The relevant decoder pin („Switch input 1) must be cut off in such cases. This is not done at the factory because the pin is needed for non-Märklin applications.
68 x 29 x 20 mm
See the chapter “Loco adaptor boards for large-scale decoders” for more information about these boards. 56 x 32 x 21mm
51 x 40 x 13 mm
.
.
Page 4 Large-scale Decoder & Sound Decoder MX695/6/7/9
2 Technical Information
.
Track Voltage in digital mode (DCC) ................................................................................. 10 - 30 V
(peak) in analog mode (High voltage pulse for direction reversal) ........................................ 35 V
Threshold voltages in analog mode - see below!
Maximum continuous motor output = maximum continuous total output MX695 .......................... 6 A
Maximum continuous motor output = maximum continuous total output MX696, MX697 ............. 4 A
Maximum continuous motor output = maximum continuous total output MX699 .......................... 6 A
Maximum peak current (Motor only or total) ............................................................................. 10 A
Number of function outputs ..MX695KV, MX695LV, MX695KN, MX696V ….……………...........14
MX699KV, MX699LV ................................................................... 15
MX695KS, MX695LS, MX696S, MX696N, MX699KS, MX699LS . 8
MX697V, MX697S ....................................................................... 10
Maximum continuous function output current ........................................................................... 2 A
Maximum continuous output for low-voltage functions (5 V, 10 V, adjustable) ................. each 1 A
Voltage range for adjustable low-voltage functions (MX695KV, -LV) .............................. 1.5 to 16 V
Maximum current at special output for Smoke-Ventilator (5 V - Motor) with brake function . 200 mA
Storage capacity for sound samples .................................................................................. 32 Mbit
Playback frequencies according to sound sample ...................................................... 11 or 22 kHz
Number of simultaneously playable sound channels ..................................................................... 6
Sound-amplifier output at 4 Ohm ................................................................................. Sinus 10 W
Loudspeaker impedance ........................................................ 8 Ohm, 2 x 8 Ohm parallel or 4 Ohm
Externally connectable energy storage device . ............................................. charging voltage 17 V
for standard electrolytic capacitors ...................... >= 20 V, any capacity
Gold-caps (pack with 7 pieces at 2,5 V ea. - in series) >= 17 V, max. 1 F
Rechargeable battery (only with special circuitry) .............. 14.4 V pack
Charge current for external energy storage ......................................................................... 80 mA
Analog mode (DC or AC) *) ............................................Threshold-voltage headlights ........... @ 4 V
Threshold-voltage sound ................. @ 5 V
Threshold-voltage motor .................. @ 6 V
Operating temperature ................................................................ ............................... - 20 to 100 oC
Dimensions (L x W x H including screw terminals) **) MX695-, -99KV, -KS ..... 50 x 40 x 13 mm
(L x W x H including pins)............................MX695-, -99LV ............. 50 x 40 x 13 mm
in cases of long plug-in pins for ESU-loco boards with MX695LS ...................... 50 x 40 x 20 mm
MX696 ......................... 55 x 29 x 16 mm
MX697 ......................... 56 x 32 x 21 mm
*) Actual analog-characteristics depend heavily on the type of power pack and the locomotive’s drive train (because the transformer output voltage may collapse more or less under load) **) Length given without break-away mounting brackets; these increase the length by 2 x 6 mm
RailCom is a registered trademark by Lenz Elektronik GmbH
ZIMO ELEKTRONIK Schönbrunner Straße 188, 1120 Wien, Österreich www.zimo.at office@zimo.at Tel +43 (1) 81 31 007 0
130=MX630 (Rev. 2019) 135=MX635 136=MX636 137=MX637 142=MDS442 160=MX660 182=MX682 (2019) 190=MX659 192=MX622 (Rev. 2019) 193=MX638 195=MX616 196=KISS Silberlinge 197=MX617 198=FLM_E69 199=MX600 200=MX82 201=MX620 202=MX62 203=MX63 204=MX64 205=MX64H 206=MX64D 207=MX680 208=MX690 209=MX69 210=MX640 211=MX630-P2520 212=MX632 213=MX631 214=MX642 215=MX643 216=MX647 217=MX646 218=MX630-P25K22 219=MX631-P25K22 220=MX632-P25K22 221=MX645 222=MX644 223=MX621 224=MX695-RevB 225=MX648 226=MX685 227=MX695-RevC 228=MX681 229=MX695N 230=MX696 231=MX696N 232=MX686 233=MX622 234=MX623 235=MX687 236=MX621-FLM 237=MX633 238=MX820 RevA 240=MX634 241=MX686B 242=MX820RevB 243=MX618 244=Roco NextG 245=MX697 246=MX658 247=MX688 248=MX821 249=MX648-RevC,D 250=MX699
251=Roco 2067 252=Roco ICE 253=MX649 254=MX697-RevB
OVERLOAD PROTECTION
The motor and function outputs of the ZIMO large-scale decoders are designed with large re­serve capacities and are additionally protected against over-currents and short circuits. Automat­ic shutoff will occur in case of overload followed by automatic reboot attempts (which often re­sults in flashing lights).
These safety precautions do not mean that the decoder is indestructible. Please pay attention to the following:
Faulty decoder hook-up (mixed up connection wires) and improper electric connections between the motor
terminal and chassis are not always recognized and can lead to output driver damage or even total destruction of the receiver.
Unsuitable or defective motors (e.g. with short-circuited turns or collectors) are not always recognizable by their high consumption of electricity (only peaks may register) and can lead to decoder damage, sometimes long term effects can cause output driver defects.
The decoders output drivers (for the motor and function outputs) are not only at risk through over-current but also through voltage spikes as they are delivered from the motor and other inductive consumers. Depend­ing on track voltage, such spikes can reach several hundred volts and are absorbed by special protection cir­cuits inside the decoder. The capacity and speed of such elements is limited and so unnecessarily high track voltage should not be used. Never use a higher voltage than recommended for a particular vehicle. Only in ex­ceptional cases should the ZIMO adjustable range (up to 24 V) be utilized.
THERMAL PROTECTION
All ZIMO decoders come equipped with a sensor that detects the actual temperature. Once the maximum permissible value (ca. 100 oC on the circuit board) has been reached, power to the motor will be shut off. Rapidly flashing headlights (at ca. 10 Hz) will signal that a shut-off has oc­curred. Motor operation will resume automatically after a drop in temperature of about 20 oC, typ­ically after 30 to 60 sec.
SOFTWARE UPDATE
ZIMCO decodes are designed so that software updates can be completed by the user. This re­quires a device with an update function (ZIMO decoder update module MXDECUP, or MXULF,
or “central system cab“ MX31ZL/MX32ZL, or command station MX10).The update itself is car- ried out via a USB stick (MXULF, MX31ZL, MX32ZL, MX10) or via a computer with the “ZIMO Sound Programmer” ZSP software or “ZIMO Rail Center” ZIRC software.
There is no need to remove the decoder; the locomotive does not need to be opened; it can be placed onto the update-track (connected to the update-device) without any changes and can then be updated via a USB stick or a computer.
Note: Locomotive accessories that are directly connected to a track (not controlled by the decoder) may inter­fere with the update; in that case the locomotive will have to be opened and removed from the track.
The decoder type can be read out in CV #250
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 5
3 Installation and Wiring of the MX695 - MX699
Page 6 Large-scale Decoder & Sound Decoder MX695/6/7/9
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 7
MX697
Page 8 Large-scale Decoder & Sound Decoder MX695/6/7/9
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 9
The following connection diagrams are based on the MX699.
The connections on the MX696 and MX697 are placed differently, but functionally similar
3.1 Tracks and motor(s)
The loco must provide enough space inside, so the decoder can be mounted without exerting me­chanical stress.
All direct connections that are present in the original wiring con­figuration between the power pick-ups (wheels and wipers) and the motor must be insulated.
The same is important for the headlights and other additional accessories, which must be com­pletely insulated.
Tracks (wheels, wipers) and mo­tor are connected to the corre­sponding positions on the screw terminals (pins) according to the picture. The second connection points (only partly available) can, but do not have to, be used addi­tionally.
Generally, all DC motors used in model railways can be used. In case, there is more than one motor in the loco, those are connected in parallel and com-
bined with each other to the decoder. A parallel connection like this ensures an automatic alignment, provided it is an identical motor- and transmission arrangement. The MX699 usu­ally is always strong enough to handle two or more motors.
See configuration (CVs) for motor regulation!
The connection pins for tracks and motor are available twice on the decoder, to enable send­ing the full voltage through the relatively thin cables. For a use of up to 2 A, it is, however, sufficient to use only one pin.
3.2 Speaker, cam sensor and volume regulation
All 4 Ohm or 8 Ohm speakers can be used, or even some speakers connected in paral­lel, so there is a total impedance of not more than 4 Ohm.
The sound amplifier of the MX699 works with 10.8V and therefore presents a sinus power of 12 Watt onto a 4 Ohm speaker; onto an 8 Ohm correspondingly less, i.e. about 5 Watt.
In case, tweeters are used, they are con­nected in parallel to the main speaker via a frequency crossover (e.g.: a capacitor of 10 μF).
Attention: for speakers with lower specifica­tions the volume has to be adjusted to the processable track power.
A cam sensor (to synchronize steam chuffs with wheel rotation) is usually not neces­sary, because the software-provided “virtual cam sensor” is sufficient.
In case there is a real cam sensor, a mechanical contact or a photo transistor, as well as a
Hall sensor can be connected to the switch input “IN3”. The corresponding element has to
produce a low-resistance (i.e. <10K) connection between switch input and GROUND in the desired rotation-dependent cycle.
The volume can be controlled alternatively or additionally to the CV-configuration (see CV #266) via the connections to an external regulator in the loco.
ONLY MX695: If such a regulator is used (100K, preferably logarithmic), the regulator on
the PCB shall be set to the highest possible volume (left limit stop), unless it is used to limit the maximum volume to protect a lower-power speaker.
Note to the decoder MX696, MX697, MX699:
These large-scale decoders (i.e. all except the MX695) do NOT have a volume regulator on the PCB. Nevertheless, external volume control units (potentiometers, 10K for MX697, 5K for MX699) can be connected. This is NOT possible with MX696!
Page 10 Large-scale Decoder & Sound Decoder MX695/6/7/9
3.3 Consumers and low voltage outputs
“Consumers” (or function elements) is all equipment connected to the function outputs Flf,
Flr, FO1-FO13. Mostly, this is lighting equipment (light bulbs and LEDs), but also positioning magnets, small motors, relays, etc.
Each consumer (light bulbs, groups of light bulbs or other) is always connected to the corre­sponding function output (negative) and to one of the up to 4 positive poles (positive):
- Positive pole - full track voltage: the directly commutated driving voltage; depending on the stabilization of the digital command station and track voltage, this is relatively unstable, i.e. oscillates with the driving voltage.
- Low voltage - 10V: this is the voltage mostly used within the decoder to produce sound. AT- TENTION: too much or volatile consumption by the consumers at the 10 V source can impair the sound quality. A short circuit on the 10 V output can damage the decoder. Therefore, on­ly use it, if there is no other possibility (i.e. the adjustable low-voltage output is already in use).
- Low-voltage - 5 V: this voltage is provided for servos and consumers, e.g. also for common 5 V light bulbs.
Only in V-types!
- the adjustable (= variable) low-voltage: via a coding switch on the decoder PCB, which leads to the space between FO12 and FO13, the low-voltage can be adjusted in the following steps: 1.5 V, 6.5 V, 10V, 15V.
Only in V-types!
NOTE: Rather use a low-voltage source than reducing the voltage per software (dimming with CV #60), because dimming uses PWM reduction (full voltage impulses with a corre­sponding duty cycle), which can damage light bulbs (not LEDs).
See chapters concerning decoder configuration (CVs) for function mapping, function ef­fects, electrical couplers (systems by Krois, Heyn), etc.
Note to decoders MX696:
The MX696 does NOT have the (definite) 5 V low-voltage. If needed (e.g. for servos) the ad­justable low-voltage (only MX696V) has to be used.
Note to decoders MX696N (non-sound version):
Those provide a 6 V low voltage output (instead of the 10 V low voltage of the sound decod­ers). Due to this, servos can be supplied directly by the decoder.
3.4 Special connections for smoke-fans
Those outputs are used to control fan motors of clocked smoke generators, as they are used in many modern locos.
The special feature of these outputs (in contrast to the “normal” function outputs) is the
possibility to brake the motor. This inhibits the motor from rotating after a current impulse, whereby the steam-clocking gets stronger and more accentuated. The outputs are de­signed for a 5 V motor and for a load capacity of up to 100 mA continuous current (the start-up current may be higher).
The decoders MX695, MX696 and MX697 only have one fan output.
3.5 Servos
The MX699 provides 4 connections for common servos, which can be used for couplers, pantographs and other mechanical equipment.
ATTENTION: Servos of different manu­facturers all have three wires, but the or­der and colors of the wires differ.
See chapter concerning decoder con­figuration regarding allocation and setting of the servos.
5V supply for servos is only available in V-types. The control wires on the other hand can be used in all types of the MX695; if needed, the 5 V supply has to be provided externally.
The 5 V supply for servos is only availa­ble in the MX695KV, MX695LV and other V – type models! The control wires though are usable with all sound decoder versions; if necessary, use an external 5V power source to power the servo.
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 11
the Goldcap module GOLMRUND, often used as stay-alive capacitor it consists of 7 Goldcaps, i.e. 7 x 1F, in total 140000 μF / 17.5 V.
3.6 Switch inputs
Additionally to the switch input “IN 3” (see chapter 3.2, speaker and cam sensor) there are 3 further inputs (“IN 1”, “IN 2” and “IN 4”). These can be used to connect reed contacts to trig-
ger sounds, etc. Electrically, those switch inputs behave very similar. See chapter concerning decoder configuration (CVs), especially regarding sound.
3.7 External stay-alive capacitor
A stay-alive capacitor (a bigger electrolytic capacitor, a “Goldcap”, etc. or a bat­tery)
- improves the driving behavior on dirty tracks (or wheels),
- reduces flickering lights caused by interrupted contact (e.g. frogs),
- Prevents the train from getting stuck when driving slowly, especially in combination with the ZIMO software fea­ture “prevent stopping on tracks without current” *),
- compensates energy loss produced by RailCom and HLU cut-outs and the corre­sponding motor sound, additionally improves the quality of the RailCom signal.
*) In case, the current supply is interrupted (due to dirty rails or frogs), the decoder auto­matically provides enough energy to move the train forward, even if it was currently in a braking procedure and was supposed to stop. The train is stopped as soon as the wheel­track-contact is reestablished. After the train stopped, the decoder tests again for track power (if there is none, the engine moves the train a little forward until power is restored).
Generally, the efficiency of energy storage modules increases with the capacity; starting with
1000 μF (μF = Micro Farad) you can see an effect, about 100,000 μF are recommended for
large-scale locos, as far as there is enough space in the loco. Goldcap modules with a capacity of 1 F do have a bigger effect. Too big capacities have the disadvantage of very long charging times; this is why ZIMO recommends not more than 0.5 F for Goldcap modules (related to full voltage of about 15 V to 25 V from a series connection of 6-10 elements with 2.5 V each; a single Goldcap therefore has a capacity of up to about 3 F.
Proper preparations in ZIMO large-scale locos (capacitor+ connection) ensure that external capaci­tors do not cause problems when programming decoders or updating the software (referring to ZIMO loco number recognition via RailCom).
The charging current for the stay-alive capacitor on the positive connection is about 100 mA, i.e. fully charging a 10,000 μF capacitor takes about 5 seconds, a 0.5 F Goldcap takes about 3 minutes.
The ZIMO Goldcap mostly used is the GOLMRUND (and the GOLMLANG), which consists of 7 Goldcaps, 1F / 2.5 V each, ergo 140.000 μF / 17.5 V in total. The capacitor+ connection on the decoder ensures that the charging voltage does not get too high.
Using a battery instead of a capacitor can only be recommended for experts (engineering spe­cialists); it is very important that the battery is completely discharged after taking the loco off the supply of the tracks. Tip: a relay, supplied by the running voltage, with a capacitor hold cir­cuit, which interrupts the connection to the battery after about 1 minute of lost supply.
Note to decoders MX699:
Contrary to other types, the MX699 also have an internal stay-alive capacitor, which consists of 3 Supercaps in series, each with 3 F / 2.7 V, i.e. 1 F and 8 V in total. This capacitor ensures securely passing parts without current, possibly with reduced speed. The sound supply is guaranteed by transforming 8 V to 10 V, so the sound is fully preserved.
Nevertheless, it may be useful to connect an external stay-alive capacitor, like a GOLMRUND, because it is charged to higher voltage (17.5 V instead of 8 V). This provides more voltage and energy for motor and functions.
3.8 SUSI interface
The “SUSI” interface was developed by Fa. Dietz and
defines the connection of additional modules to the decoder. Usually these are sound modules, which are used in combination with non-sound decoders, i.e. MX695KN and MX696N.
Additional to the sound modules, the market also pro­vides digital couplers with a SUSI interface. Some lo­cos have PCBs for pantographs with SUSI interface integrated, wherefore they can use the interface on the decoder.
Furthermore, the SUSI interface is used for loading a sound project or update fast (with the decoder updat­ing and testing device MXULF/A); however, this uses faster communication instead of the SUSI protocol.
Page 12 Large-scale Decoder & Sound Decoder MX695/6/7/9
68 x 26 x 6 mm
4 Loco Adapter Boards for Large-Scale Decoder
Locomotive adapter boards serve as an "intermediate part" between the engine and the decoder, to facilitate the decoder installation and connection to the various loco components. It also allows for an easy exchange of the decoder when necessary. Additionally, some loco boards also offer a low voltage output (i.e. for servos).
Note: Adapter boards for ZIMO large-scale decoders DO NOT contain an additional synchronous rectifier to increase power, as do the boards for “small” decoders (for N, HO etc., see operating manual for MX618, MX621...MX648 decoder). This would be redundant due to the very strong
and low-loss synchronous rectifier already present in large-scale decoders. Because of the very different needs, there are a relatively large number of types or versions of
these locomotive boards available. In addition to the standard types described below, special de­signs are also manufactured (for a minimum-order quantity of about 50, mostly for vehicle manu­facturers) that are based on the standard printed circuit boards, but with different or differently ar­ranged connectors.
Loco boards LOKPL95BS, -BV with solder pads, designed for the large-scale decoders MX695LS and MX695LV
The wires from the locomotive (motor, track, lights, speakers...) are soldered directly to the solder pads and an appropriate decoder is plugged into these boards. Depending on the type of the lo­co board (-BS or BV), these are either simple circuit boards (no other electronic components on the board) or a board with "additional benefits" (in this case a voltage regulator for low voltages, which is often useful to have):
LOKPL95BS LOKPL95BV circuit board with solder pads, with additional variable low voltage
usabilty of upper connector row (Adjustable from 1.5 V to track voltage), depends on the decoder type otherwise identical plugged in
Loco board LOKPL95BV with decoder MX695 plugged in
NOTE: The servo connections are NOT accessible on the loco board. They are therefore directly plugged in to the decod­er (at the 3-pin sockets of the MX695).
Special applications may also contain servo connectors on the loco board (i.e. with special board layouts that have enough room on the underside).
Loco boards LOKPL96... designed for large-scale decoders MX696S and MX696V
The large-scale decoder family MX696 differs from the MX695 by their narrow designs (29 mm instead of 40 mm). The slightly lower rating (4 A instead of 6 A) is not all that significant, but the MX696 is not equipped as well with low voltage outputs as the MX695, in particular the 5 V – supply is lacking. The loco boards LOKPL96.V therefore offer a 5 V source (and the complete servo connectors), but no variable low-voltage as the ...PL95.
Connection diagram for loco boards
LOKPL96BS (Solder pads)
and LOKPL96BV LOKPL96LS (Plug-in) and LOKPL96LV LOKPL96KS (Screw terminals) and LOKPL96KV
LOKPL96BS LOKPL96BV
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 13
circuit board with solder pads, with additional 5 V low voltage usability of upper connector row (for servos), otherwise depends on the decoder identical type plugged in
LOKPL96LS LOKPL96LV Circuit board with with additional 5 V low voltage (for servos),
10-pin plugs, complete servo connections, usability of upper connector row and third 10-pin plug (angled) depends on the decoder type plugged in
This version (-LS) is designed to combine This version (-LV) is designed to combine with the MX696S decoder: with the MX696V decoder. The angled pins (at the back for the higher FO’s and in the front for servo’s) must be bent or cut off if space is limited.
The 10-pin plugs can be connected with the locomotive using cable and crimp sockets (also available from ZIMO). The 3-pin servo connectors accept the typical servo plugs (se­quence: GROUND - 5V - control).
Suitable for LGB locos with 10-pin "DCC interface", which has the exact mirror image of the LOKPL96LS (or LV) board’s left connector. The connecting cable is therefore particularly easy to produce.
LOKPL96KS LOKPL96KV
Circuit board with with additional 5 V low voltage (for servos), 10-pin screw terminals, complete servo connections, usability of upper connector row and a third row of screw terminals depends on the decoder type plugged in
This version (-KS) is designed to combine This version (-KV) is designed to with the MX696S decoder. combine with the MX696V decoder. The angled servo pins must be bent or cut off if space is limited.
Sold as a single decoder type -
Combinations of loco board and decoder
Particularly useful combinations of loco board and decoder are treated as separate decoder types (with their own names, part numbers and prices): this is especially true for
LOKPL96KS + MX696S = MX696KS
This decoder combination is similar to the type MX695KS in terms of functions and connectivy (Screw terminals) but is much narrower (29 instead of 40 mm).
LOKPL96KV + MX696V = MX696KV
This decoder combination is similar to the type MX695KV in terms of functions and connectivy (Screw terminals) but is much narrower (29 instead of 40 mm).mm).
Combination LOKPL96KV + MX696V = MX696KV
Page 14 Large-scale Decoder & Sound Decoder MX695/6/7/9
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 15
Page 16 Large-scale Decoder & Sound Decoder MX695/6/7/9
Special loco board LOKPLSHMAL as carrier of the large-scale decoders MX696S or MX696V
This board is a special development for the “HSB Mallet 995901” engine from TrainLine, but can
also be used by other engine manufacturers, workshops as well as private model railroaders.
100 x 56 x 20 mm
Loco board LOKPLSHMAL
with plugged-in decoder MX696S
Connection diagram for loco board LOKPLSHMAL
NOTES for LOCO-CONVERSION (using the example of the Train Line HSB Mallet 995 901):
The original board in the vehicle is removed and replaced by the Zimo "Special Loco board" (with inserted decoder MX696S). The Zimo loco board has the same connectors (but no connection for a potentiometer) and also the same holes for the mounting screws as the Train Line original board. The plugs are labeled on the Zimo loco board the same as the original board, i.e. J1, J2, J3, etc. The exchange of the loco board is therefore very easy. It is recommended to first mark the cables - at least the two-pole – in order to make the correct connections on the Zimo loco board ... It makes sense to previously remove the decoder (for better accessibility of the loco board connectors) and to plug it back in after finishing the installation of the loco board.
The ZIMO loco board, in contrast to the TrainLine original board, offers a connection (double screw terminal in the lower right corner) for an energy storage device: preferably a ZIMO gold cap module GOLMRUND or GOLMLANG.
Additionally: connections for uncouplers (for servos or Massoth uncouplers). The conversion of the "analog version" ("A-Lok" that comes without a decoder, but does have a
loco board and connection board installed, which both have to be removed) is the same as for the "digital" version ("D-Lok" which includes a factory-installed decoder); they differ mainly with respect to the smoke generator. It is therefore necessary to place the 6 jumpers on the loco board accordingly; ideally BEFORE the installation – the loco board, as delivered, is set for the “analog version” (”A-Lok”).
The decoder offered for the HSB Mallet already contains a particularly high quality sound project from Heinz Däppen and is optimized for this model. The decoder is also provided with a valid load code to facilitate possible future firmware upgrades or an improved version of the sound project. The “ZIMO & Däppen” sound offers a number of advantages for this vehicle, compared to the manufacturer’s original digital version: prototypical chuff beats (not exaggeratedly hard), cylinder typical “load sounds”, Mallet-typical sound even in the lower speed range, sound of aux­iliary units from the actual locomotive. More info ... in special document "Upgrading Notes"
The upgraded locomotive: Goldcap-Module on the left, decoder on the right.
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 17
Loco board LOKPL99 with solder pads, for large-scale decoders MX699LS and MX699LV
When installing these loco boards, all wires (track, motor, speaker, bulbs...) are soldered to the loco board and after that, the approrpiate decoder is plugged in.
Connection diagram for loco board LOKPL99 (with solder pads)
62 x 40 x 10 mm
WILL BE ADDED LATER
NOTE: The servos are connected directly to the decoder MX695. For this reason, the loco board has special cut-outs
LOKPL99
WILL BE ADDED LATER
WILL BE ADDED LATER
Loco board LOKPL99 with decoder MX699LS or –LV plugged in
Page 18 Large-scale Decoder & Sound Decoder MX695/6/7/9
CV
Designation
Range
Default
Description
#144
Programming and
Update Lock
Note: The programming
lock has no effect on
CV #144, which is
therefore always ac-
cessible for unlocking.
Bits 6, 7
0
or
255
= 0: Update and programming lock not active Bit 6 = 1: No programming possible in service mode:
protection against unintentional program­ ming.
Note: Programming in “Operations Mode“ is not locked because any such programming only applies to the active loco address and re programming the wrong locomotive is there­ fore not possible.
Bit 7 = 1: Software updates via MXDECUP, MX31ZL or other means are locked.
#112
Special ZIMO configu-
ration bits
0 - 255
4 =
00000100
That is
Bit 1 = 0 (normal)
Bit 1 = 0: Normal “service mode“ acknowledgement; i.e. motor and headlights are pulsed. = 1: High frequency pulses instead of normal acknowledgments from motor and headlights.
Bit 2 = 0: loco number recognition off etc,
CV
Designation
Range
Default
Description
#28
RailCom
Configuration
0 - 3
3
Bit 0 - RailCom Channel 1 (broadcast) 0 = off 1 = on
Bit 1 - RailCom Channel 2 (Data) 0 = off 1 = on
#29
Base Configuration
Configuration data
0 - 63
14 =
0000 1110
That is
Bit 3 = 1
(“RailCom“
is on)
Bit 0 – train direction 0 = normal, 1 = reversed
Bit 1 - number of speed steps 0 = 14, 1 = 28
Bit 2 – DC operations (analog mode) 0 = disabled 1 = enabled
Bit 3 - RailCom (bi-directional communication) 0 = off 1 = on
Bit 4 – individual speed table 0 = off, CV #2, 5 and 6 are active. 1 = on, according to CV ‘s #67 – 9494
Bit 5 – Decoder address (DCC) 0 = primary address as per CV # 1 1 = ext. address as per CV’s #17+18
5 Configuring the MX695 - MX699
ZIMO decoders can be programmed in
- “Service Mode” (on the programming track) for assigning a new address or reading and writing CV content, or in
- “Operations Mode” (a.k.a. “Programming on the main” or “PoM”), which is done on the main track; programming CV’s “on the main” is always possible in operations mode. However,
an acknowledgement of successful programming steps or when reading out CV’s is only pos-
sible with a DCC system capable of “RailCom”.
5.1 “Service mode” programming (on the programming track)
Before programming is possible, it must be unlocked with
CV #144 = 0 or = 128 (the latter allows programming but prevents decoder updating).
This (CV #144 = 0) is normally the default setting, but the programming lock is activated in many sound projects to prevent accidental changes. It is therefore recommended to check that CV, es­pecially when attempted programming has already failed.
Successful programming steps as well as CV read-outs on the programming track are acknowl­edged by decoder-generated power pulses, by briefly turning on the motor and/or headlights. If the motor and/or headlights do not draw power (i.e. they are not connected) or don’t draw enough power, acknowledgments for successful programming or CV read-outs are not possible.
To make acknowledgments possible in such cases activate CV #112 bit 1, which enables the de­coder to use an alternate acknowledgment by sending high frequency pulses from the motor end stage. Whether this method is successful though depends on the DCC system used.
Attention: The CV values of a sound decoder in the delivery state do NOT correspond with the default values in the following chapters, but rather the initial values of the loaded sound project! This applies most often to CV #29 – analog operation is usually turned off (Bit 3 = 0); CV #29 = 14 turns this on if desired. CV #144 – the update lock may be activated (Bit 7 = 1), sometimes even the programming lock (Bit 6 = 1); before updating or programming a decoder, set this CV to CV #144 = 0. CV #3, 4 – acceleration and deceleration CV’s are often set to higher values (i.e. 12). CV #33 and following – the functions are often mapped to a specific loco model. …and of course the sound CV’s (from CV #265) and (less frequently) all other CV’s.
5.2 “Operations mode” programming (on-the-main)
Programming in “Operations mode”, otherwise known as Programming-on-the-main” = PoM
“Programming-on-the-fly”.
According to the current NMRA DCC standards it should only be possible to program and read CV’s on the main track, but not assign new vehicle addresses. However, certain DCC systems (among them ZIMO beginning with the system generation MX10/MX32) will allow addresses to be modified on the main track with the help of bidirectional communication.
All ZIMO decoders are equipped with bidirectional communication (“RailCom”) and can there­fore (with a corresponding DCC system such as ZIMO MX31ZL and all devices of the new MX10/MX32 generation) read, program and acknowledge successful CV programming steps in operations mode (on the main track). This requires RailCom to be activated, which is the case if the following CV’s are set as:
CV #29, Bit 3 = 1 AND CV #28 = 3
This is usually the default setting, but in certain sound projects or OEM CV sets it may be turned off by default and must first be turned on again.
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 19
CV
Designation
Range
Default
Description
#250, #251, #252, #253
Decoder-ID
also contains
Decoder type in
CV #250
(see chapter 1, “Product Overview” for decoder type code)
read only
-
The decoder ID (serial number) is automatically en­tered during production: the first byte (CV #250) de­notes the decoder type; the three other bytes contain the serial number.
The decoder ID is primarily used for automatic ad­dress assignment when an engine is placed on the layout track (future function) as well is in conjunction
with the “load code” for “coded” sound projects (see
CV #260 – 263)
#260, #261, #262, #263
Load-code
for
"coded” sound projects
-
-
New ZIMO sound decoders can be ordered for a
small fee with the “load code” pre-installed, which en- titles the user to install “coded” sound projects of a
selected sound “bundle”. The load code can also be bought and installed at a
later date: see www.zimo.at or ZIRC.
#8
Manufacturer ID
and
HARD RESET
with CV #8 = “8“
or CV #8 = 0
or
ACTIVATION
of special CV sets
Read only
Reading out the decoder
always shows
“145”, which
is ZIMO’s
assigned
number.
For pseudo
programming
see the
description
on the right.
145
( = ZIMO)
Reading out this CV always result in “145” (”10010001”), the number issued for ZIMO by the
NMRA. This CV is also used to execute various resets with
the help of Pseudo-Programming.
Pseudo-Programming means that the entered value is not real­ly stored, but rather used to start a defined action.
CV #8 = “8” HARD RESET (NMRA standard); all CV’s reset to the last active CV set (incl. sound pro- ject), or the default values as listed in this CV table if no such set was active before.
CV #8 = “9”  HARD RESET to old LGB-MZS system (14 speed steps, pulse chain commands).
Further options: see chapter “CV Sets”!
#7
SW version number
Also see CV #65 for
sub-version number
and
special programming
procedures with
“Lokmaus-2” and other
“low level” systems
Read only
For pseudo
programming
see the
description on the right
-
This CV holds the main number of the currently load­ed decoder software (firmware).
It is also used via “pseudo programming“ to program decoders with DCC systems of limited numbers range (typ. example: old Lokmaus):
Ones digit = 1: Subsequent programming value + 100 = 2: ... + 200 Tens digit = 1: Subsequent CV number + 100 = 2: … + 200 etc. = 9: … + 900 Hundreds digit = 0: Revaluation applies only once = 1: … until power-off
#65
SW sub-version num.
See also CV #7 for
main version number
Read only
-
This CV indicates a possible sub-version number of a main version noted in CV #7.
The entire SW version number is thus composed of CV #7 and #65 (i.e. 28.15).
CV
Designation
Range
Default
Description
#1
Short address
DCC:
1 - 127
MM:
1 - 80
3
The “short” (1-byte) loco address (DCC,MM) In the case of DCC: The address in CV #1 is only valid if CV #29, Bit 5 = 0. Otherwise, if CV #29 Bit 5 = 1, the long address in CV
#17 + #18 applies.
#17
+
#18
Extended Address
128
-
10239
0
The long DCC address applies to addresses >127. It is only active if CV #29 Bit 5 = 1.
#29
Base Configuration
0 - 63
14 =
0000 1110
with
Bit 5 = 0
(for short address)
Bit 0 – Train direction: 0 = normal, 1 = reversed
Bit 1 - Number of speed steps: 0 = 14, 1 = 28
Bit 2 – DC operation (analog mode) 0 = disabled 1 = enabled
Bit 3 - RailCom (bi-directional communication“) 0 = deactivated 1 = activated
Bit 4 – Individual speed table 0 = off, CV #2, 5 and 6 are active. 1 = on, according to CV ‘s #67 – 9494
Bit 5 - Decoder address selection: 0 = short address as per CV #1 1 = long address as per CV #17+18
5.3 Decoder-ID, Load-Code, Decoder-Type and SW-Version
5.4 Engine address(es) in DCC mode
Decoders are usually delivered with default address 3 (CV #1 = 3), for the DCC as well as MM protocol. All aspects of operations are possible with this address but it is recommended to change to a different address as soon as possible.
The address space required for DCC exceeds the range of a single CV, up to 10239 in fact. Addresses higher than 127 are stored in CV #17 and #18. Bit 5 in CV #29 is used to select be­tween the short address in CV #1 and the long address in CV’s #17/18.
Most digital systems (with the possible exception of very old or simple products) automat-
ically calculate the value for the CV’s involved and also set Bit 5 in CV #29 to the proper
value when writing the address, so that the user does not have to deal with the necessary coding.
Page 20 Large-scale Decoder & Sound Decoder MX695/6/7/9
CV
Designation
Range
Default
Description
#19
Consist address
0 - 127
0
A consist address common for 2 or more engines can be entered in this CV to each loco of the same consist.
If CV #19 > 0: Speed and direction is governed by this consist address (not the individual address in CV #1 or #17+18); functions are controlled by either the consist address or individual address, see CV’s #21 + 22.
Bit 7 = 1: Driving direction reversed
#20
Extended consist ad-
dress
From SW version 36.6
0 - 255
0
The value of CV20 multiplied with 100 added together with the value of CV 19 which result is the address at consist. e.g. CV20= 12, CV19=34 is address. 1234 CV20=100, CV19=00 is address 10000
#21
Consist Functions
F1 - F8
0 - 255
0
Functions selected with this CV will be controlled by the consist address.
Bit 0 = 0: F1 controlled by individual address = 1: …. by consist address
Bit 1 = 0: F2 controlled by individual address = 1: …. by consist address
………. F3, F4, F5, F6, F7
Bit 7 = 0: F8 controlled by individual address = 1: …. by consist address
,
#22
Consist Functions
F9 – F27
and
headlight control
0 - 191
0
Select whether headlights and/or functions F9 – F12 are controlled via consist address or single address.
Bit 0 = 0: F0 (forw.) controlled by individual address = 1: …. by consist address
Bit 1 = 0: F0 (rev.) controlled by individual address = 1: …. by consist address
Bit 2 = 0: F9 controlled by individual address = 1: …. by consist address
Bit 3 = 0: F10 controlled by individual address = 1: …. by consist address
Bit 4 = 0: F11 controlled by individual address = 1: …. by consist address
Bit 5 = 0: F12 controlled by individual address = 1: …. by consist address Bit 7 = 1: F13 – F27 (all !) …. by consist address
CV
Designation
Range
Default
Description
#13
Analog Functions
F1-F8
0 - 255
0
Defines function outputs that should be “ON” in analog mode.
Bit 0 = 0: F1 is OFF in analog mode = 1: …ON in analog mode
Bit 1 = 0: F2 is OFF in analog mode
Bit 1 = 1: …ON in analog mode ………..F3, F4, F5, F6, F7
Bit 7 = 0: F8 is OFF in analog mode Bit 7 = 1: …ON in analog mode
#14
Analog functions
F9 – F12,
Analog momentum
and
Regulated Analog
0 - 255
64
(Bit 6 = 1)
Defines function outputs that should be “ON” in analog mode.
Bit 0 = 0: F0 (forw) is OFF in analog mode = 1: …ON in analog mode
Bit 1 = 0: F0 (rev) is OFF in analog mode Bit 1 = 1: …ON in analog mode
Bit 2 = 0: F9 is OFF in analog mode Bit 2 = 1: …ON in analog mode
------------F10, F11 Bit 5 = 0: F12 is OFF in analog mode
Bit 5 = 1: …ON in analog mode Bit 6 = 0: Analog operation with acceleration and
deceleration according to CV #3 and #4. Bit 6 = 1: Analog operation without acceleration and deceleration according to CV #3 and #4.
Decoder-controlled consisting (a.k.a. "advanced consisting”)
The combined operation of two or more locomotives (consisting) can be organized by
- the DCC system (common practice with ZIMO systems, without changing any decoder CV’s) or
- by programming the following decoder CV’s individually, which can also be managed by some
DCC systems (often the case with American made systems). This chapter covers only the latter; the decoder controlled consisting!
5.5 Analog operation
All ZIMO decoders are capable of operating in DC analog on conventional layouts (with DC power packs, including PWM throttles) as well as in AC analog (Marklin transformers with high voltage pulse for direction change).
To allow analog operation
CV #29, Bit 2 = 1
must be set. This is usually the case by default (CV #29 = 14, which includes Bit 2 = 1), but ana­log operation may be turned off in many sound projects (sound decoders). Check this CV first to
ensure that the analog mode is enabled if the engine won’t run on an analog layout. It is rec­ommended to set CV #29, Bit 2 = 0 when operating in a DCC environment only!
The new large scale decoders (MX695/6/7) are very well designed for analog operation because they can turn on lights, sound and the motor at a very low track voltage, by "raising” the track
voltage internally to a certain degree. See the chapter titled “Technical Data”. This effect is
achieved by applying stepped threshold voltages that is, the headlights will come on first, the sound at a slightly higher voltage and only after that will the motor start.
The actual behavior during analog operation however, is strongly influenced by the locomotive controller (power pack). Especially in conjunction with a weak transformer, it is easy possible that the track voltage collapses when the decoder (motor) starts to draw power which, in the worst case, may lead to intermittent performance. There are a number of adjustment possibili­ties for analog operations where motor control and function outputs are concerned; these CV’s can of course be read-out or programmed only with a DCC system or other programming de­vices.
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 21
CV
Designation
Range
Default
Description
Bit 7 = 0: unregulated DC operation = 1: regulated DC operation
,
#29
Base Configuration
0 - 3
0
Bit 0 – Train direction: 0 = normal, 1 = reversed
Bit 1 - Number of speed steps: 0 = 14, 1 = 28
Bit 2 – DC operation (analog mode) 0 = disabled 1 = enabled
Bit 3 - RailCom (bi-directional communication“) 0 = deactivated 1 = activated
Bit 4 – Individual speed table 0 = off, CV #2, 5 and 6 are active. 1 = on, according to CV ‘s #67 – 9494
Bit 5 - Decoder address selection: 0 = short address as per CV #1 1 = long address as per CV #17+18
CV
Designation
Range
Default
Description
#2
Vstart
(Lowest speed)
three step curve if
CV #29, Bit 4 = 0
1 - 255
1
Internal speed step (1 … 255) applied as lowest external speed step (= speed step 1)
(applies to 14, 28, or 128 speed step modes) = 1: lowest possible speed
#5
Vhigh
(Maximum speed) three step curve if
CV #29, Bit 4 = 0
0 - 255
1
equivalent
255
Internal speed step (1 … 255) applied as highest external speed step (14, 25 or 128,
depending on the speed step mode selected in CV # 29, Bit 1)
= 1 (same as 255): fastest top speed possible.
#6
Vmid
(Medium speed)
1,
¼ to ½
of the
value in
CV #5
1
(= @ 1/3
of
top speed)
Internal speed step (1 … 255) applied as medium external speed step (that is, speed step 7,
14 or 63 depending on the speed step mode selected in CV #29, Bit 1)
1" = default curve (Medium speed is set to one third of top speed. I.e., if CV #5 = 255 the curve is the same as if CV #6 would be programmed to 85).
The speed curve resulting from CV #2, 5 and 6 is au­tomatically smoothed out.
#29
Basic Configuration
Configuration data
0 - 63
14 =
0000 1110
Bit 2 = 0
(three step
speed curve)
Bit 0 - Train direction: 0 = normal, 1 = reversed
Bit 1 - Number of speed steps: 0 = 14, 1 = 28/128
Bit 2 - DC operation (analog): 0 = disabled 1 = enabled
Bit 3 - RailCom (“bidirectional communication“) 0 = deactivated 1 = activated
Bit 4 - Individual speed table: 0 = off, CV # 2, 5 and 6 are active. 1 = on, according to CV ‘s # 67 – 94
Bit 5 - Decoder address: 0 = primary address as per CV #1 1 = ext. address as per CV #17+18
#67 .…..
#94
Individual Speed
Curve,
if CV #29, Bit 4 = 1
0 - 255
*)
User programmable speed table.
Each CV corresponds to one of the 28 external speed
steps that can be “mapped” to internal steps (1 – 255).
*) The 28-point default curve is also bent in the lower
speed range.
#66 #95
Directional Speed
Trimming
0 - 255 0 - 255 0 0
Speed step multiplication by “n/128” (n = trim value) for forward (CV # 66) or reverse direction (# 95).
Note: Actual decoder settings may differ from the default values if a sound project is on the decoder; in par­ticular, the motor regulation (CV #14, Bit 7) is often enabled. The regulation only works well with power packs that apply “clean” DC voltage (i.e. with an LGB 50 080); otherwise it is better to turn the motor regula­tion off.
5.6 Motor control and regulation
The Speed Curve
There are two ways of programming the speed curve:
CV #29, Bit 4 = 0: three-step curve (defined by 3 CV’s)
... = 1: 28-step curve (defined by 28 CV’s)
Three-step curve: the lowest, highest and medium speed is defined by the Configuration Vari­ables #2 (Vstart), #5 (Vhigh) and #6 (Vmid). This is a simple way to quickly establish a speed range and its curvature.
The three-step curve is usually sufficient.
28 – step curve (a.k.a. free programmable speed curve): with the help of CV’s #67 - 94, all 28 external speed steps can be freely assigned to the 128 internal speed steps. These 28 CV’s apply to all speed step modes (14, 28 and 128). If 128 external speed steps are used, the de­coder adds the missing intermediate values by interpolation.
Reference Voltage for motor control
CV # 57 specifies the voltage, which is used as a base for motor regulation. For example: if
14V is selected (CV value: 140) the decoder tries to send the exact fraction of this voltage, given by the speed regulator position, to the motor regardless of the voltage level at the track. As a result the speed remains constant even if the track voltage fluctuates, provided the track voltage (more precisely, the rectified and processed voltage inside the decoder, which is about 2V lower) doesn’t fall below the absolute reference voltage.
Page 22 Large-scale Decoder & Sound Decoder MX695/6/7/9
CV
Designation
Range
Default
Description
#57
Voltage Reference
0 - 255
0
Absolute voltage in tenth of a volt applied to the mo­tor at full speed (max. throttle setting).
Example: A system without stabilized track voltage is set to 22V at idle but drops to 16V under load: A good setting would be CV #57 = 140…150.
CV #57 = 0: automatically adjusts to the track volt­age; only useful with stabilized track voltage.
CV
Designation
Range
Default
Description
#9
Motor control
frequency
and
EMF sampling rate
(Algorithm)
55
high fre-
quency, medium
scanning
rate
algorithm
01 - 99
high fre-
quency
with
modified
EMF
scanning
rate
algorithm
255-176
low fre­quency
55
high fre-
quency,
medium
scanning
rate
algorithm
= 55: Default motor control with high frequency (20/40kHz), medium EMF sampling rate that automat­ically adjusts between 200Hz (low speed) and 50Hz and medium EMF sampling time.
<> 55: Modification of automatic adjustments with: tens digit for sampling rate and ones digit for sampling time.
Tens digit 1 - 4: Lower sampling rate than default (less noise!)
Tens digit 6 - 9: Higher sampling rate than default (to combat jerky movements!) Ones digit 1 – 4: Shorter EMF sampling time (good for coreless motors, less noise, more power)
Ones digit 5 - 9: Longer EMF sampling time (may be needed for 3-pole motors or similar).
Typical test values against jerky driving: CV #9 = 55 (default) 83, 85, 87, ... CV #9 = 55 (default) 44, 33, 22, …
= 255 - 178: Low frequency (for old motors only!) –
PWM according to formula (131+ mantissa*4) *2exp. Bit 0-4 is “mantissa”; Bit 5-7 is “exp”. Motor frequency is the reciprocal of the PWM. Examples: #9 = 255: frequency at 30 Hz, #9 = 208: frequency at 80 Hz, #9 = 192: frequency at 120 Hz.
#112
Special ZIMO
Configuration bits
0 - 255
4 =
00000100
Bit 5 = 0
(20 kHz)
Bit 1 = 0: Normal acknowledgement. = 1: High frequency acknowledgement
Bit 2 = 0: Loco number recognition OFF = 1: ZIMO loco number recognition ON
Bit 3 = 0: 12-Function Mode = 1: 8-Function Mode
Bit 4 = 0: Pulse chain recognition OFF = 1: Pulse chain recognition (for old LGB)
Bit 5 = 0: 20 kHz motor control frequency = 1: 40 kHz motor control frequency
Bit 6 = 0: normal (also see CV #29) = 1: „Märklin brake mode
#56
P- and I- Value
for
BEMF motor regulation
55
medium
PID
setting
01 - 199
modified
settings
55
= 55: Default setting using medium PID parameters. = 0 - 99: Modified settings for “normal” DC motors
(Bühler etc.). = 100 - 199: Modified settings for coreless motors (Faulhaber, Maxon etc.)
Tens digit 1 - 4: Lower proportional value than default Tens digit 6 - 9: Higher proportional value than default Ones digit 1 - 4: Lower integral than default Ones digit 6 - 9: Higher integral than default Typical test values against jerky driving:
CV #56 = 55 (default) 33, 77, 73, 71...
The default value “0” in CV #57 selects the “relative reference”, which automatically adjusts the
reference voltage to the available track voltage. This setting is only useful though if the system can keep the track voltage constant at all times (stabilized track output) and the resistance along the track kept to a minimum. All ZIMO systems keep the track voltage stable even older systems, but not every system from other manufacturers do, especially the relatively cheap systems built before 2005. It is not recommended to set CV #57 to “0” with systems that don’t keep track volt- age stabilized. Instead set this CV about 2V below track voltage (i.e. 140 for 16V).
CV #57 can also be used as an alternative to CV #5 (top speed), which has the advantage that
the full resolution of the 255 speed steps remains available.
Tweaking the motor regulation
The motor’s performance, especially at crawling speeds (should be a smooth as possible), can be fine-tuned with the following CV’s:
CV #9 – Motor control frequency and EMF sampling rate
The motor is controlled by pulse with modulation that can take place at either low or high fre­quency.
Low frequency (30 – 159Hz) is only useful for very few locomotives with very old motors (i.e. AC motors with field coils instead of permanent magnets). High frequency (20 kHz by default, up to 40 kHz as per CV #112) on the other hand is quiet and easy on the motor.
Power to the motor is interrupted periodically (50 – 200 times/sec.), even when operating at high frequency, in order to determine the current speed by measuring back-EMF (voltage gen­erated by the motor). The more frequent this interruption takes place (sampling rate), the better the load compensation performs; but that also causes power loss and increased noise. By de­fault, the sampling frequency varies automatically between 200Hz at low speed and 50 Hz at maximum speed.
CV #9 allows the adjustment of the sampling frequency as well as the sampling time. The de­fault value of 55 represents a medium setting.
CV # 56 – The PID regulation
The motor regulation can be tailored to motor type, vehicle weight and so on, by using different
Proportional-Integral-Differential values. In reality however, changing the differential value can
be omitted.
CV #56 allows the proportional value (tens digit) as well as the integral value (ones digit) to be set individually. The default value of 55 represents a medium setting, at which a certain auto­mated fine-tuning is performed by the decoder software.
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 23
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
0 20 40 60 80 100 150 200 252
D
e
f
a
u
l
t
-
R
e
g
e
l
u
n
g
s
k
e
n
n
l
i
n
i
e
C
V
#
5
8
=
2
5
5
,
C
V
#
1
0
u
n
d
#
1
1
3
=
0
v
o
l
l
e
A
u
s
r
e
g
l
u
n
g
b
e
i
L
a
n
g
s
a
m
f
a
h
r
t
,
a
b
s
i
n
k
e
n
d
b
i
s
0
b
e
i
v
o
l
l
e
r
F
a
h
r
t
.
Regleungseinfluß
Int. Fahrstufe
K
e
n
n
l
i
n
i
e
d
e
s
R
e
g
e
l
u
n
g
s
e
i
n
f
l
u
s
s
e
s
C
V
#
5
8
=
1
8
0
,
C
V
#
1
0
u
n
d
#
1
1
3
=
0
r
e
d
u
z
i
e
r
t
e
A
u
s
r
e
g
l
u
n
g
i
n
a
l
l
e
n
G
e
s
c
h
w
i
n
d
i
g
k
e
i
t
s
b
e
r
e
i
c
h
e
n
.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
0 20 40 60 80 100 150 200 25 2
D
e
f
a
u
l
t
-
R
e
g e
l
u
n
g
s
k
e n
n
l
i
n
i
e
R
e
g
e
l
u
n
g
s
k
e
n
n
l
i
n
i
e
C
V
#
1
0
=
1
2
6
,
C
V
#
1
1
3
=
2
0
0
,
v
e
r
s
t
ä
r
k
t
e
A
u
s
r
e
g
l
u
n
g
i
m
m
i
t
t
l
e
r
e
n
G
e
s
c
h
w
i
n
-
d
i
g
k
e
i
t
s
b
e
r
e
i
c
h
.
Vehicle, Type of Motor
CV #9
CV #56
Remarks
LGB-Loco with Bühler-motor(s)
(55)
(55)
The default settings are usually sufficient for good vehicle performance.
Loco with Faulhaber motor (Maxon)
12
111
Relatively rare and short EMF sampling times, “soft regulation, special Fauhaber procedure, quiet!
Märklin Gauge 1 (i.e. V100)
65
12
Slightly above average EMF sampling times, but al­so “soft” regulation.
PIKO VT98 (light construction)
91
91
High sampling rate (but short EMF sampling times), high P-value (but not I-value).
PIKO Taurus (relatively heavy)
64
63
Marginally higher sampling rate and P-value (be­tween LGB and PIKO VT98).
DEMKO Herkules, O-scale
71
141
Higher sampling rate, otherwise typical for Faulha­ber.
CV
Designation
Range
Default
Description
#58
BEMF intensity
0 - 255
255
Intensity of back-EMF for lowest speed step.
If required, an “intensity curve” can be defined for the
medium speed using CV #10, 58 and 113. EXAMPLES: CV # 58 = 0: no back-EMF
CV # 58 = 150: medium compensation CV # 58 = 255: maximum compensation
#10
EMF Feedback Cutoff
This CV is seldom used
0 - 252
0
Assigns an internal speed step where back EMF in­tensity is reduced to the level defined in CV #113. CV #10, #58 and #113 together define a back-EMF curve. = 0: default curve is valid (as in CV #58).
#113
BEMF reduction
This CV is seldom used
0 - 255
0
The BEMF intensity is reduced to this value at the speed step defined in CV #10. CV #113 together with CV’s #58 and #10 form a 3­point BEMF curve. = 0: actual cutoff at speed step in CV #10. Usually CV #10 is also set to 0.
#147 #148 #149 #150
Experimental CV’s
for test purposes,
to find out whether
certain automatic
settings have a nega-
tive effect on motor
regulation.
Using these
experimental CV’s will
deactivate the automat-
ic settings.
CV’s #147 – 149 will likely be removed again from the decoder SW at
some time.
0 0 0 0
--- CV #147 Sampling time --­Useful initial value: 20; Too small a value leads to jerky behavior. Too large a value leads to poor low speed control.
0 = automatic control (CV #147 has no effect)
--- CV #148 D-Value --­Useful initial value: 20; Too small a value leads to poor regulation (regulates too little, too slow, engine jerks (rather slowly). Too large a value leads to over compensation, the engine runs rough/vibrates.
0 = automatic control (CV #148 has no effect)
--- CV #149 P-Value --­0 = automatic control (CV #149 has no effect) 1 = P-Value is fixed as per CV #56 (tens digit)
--- CV #150 Load compensation at top speed --­Load compensation at top speed is normally always
0. This can be changed with CV #150. Example: CV #58 = 200, CV #10 = 100, CV #113 = 80 und CV #150 = 40 --> Result: Regulation at speed step 1 is 200 (of 255, almost 100%), at speed step 100 it is 80 (@1/3
rd
of 255), at speed step 252
(full speed) it is 200 (of 255, almost fully regulated).
We kindly ask for your cooperation. Please send us your test results!
Fine-tuning suggestions (if default settings are not satisfactory):
Tips on how to proceed in finding the optimal CV #56 settings:
Start with an initial setting of CV #56 = 11; Run the engine at low speed while holding it back with one hand. The motor regulation should compensate for the higher load within half a sec­ond. If it takes longer than that, increase the ones digit gradually: CV #56 = 12, 13, 14...
With the locomotive still running at a low speed, increase the tens digit in CV #56 one step at the time. For example: (if the test above resulted in CV #56 = 13) start increasing the tens digit CV #56 = 23, 33 ,43… As soon as jerky driving is detected, revert back to the previous digit this would be the final setting.
Load Compensation, Compensation Curve and Experimental CV’s
The goal of load compensation, at least in theory, is to keep the speed constant in all circum­stances (only limited by available power). In reality though, a certain reduction in compensation is quite often preferred.
100% load compensation is useful within the low speed range to successfully prevent engine stalls or run-away under light load. Load compensation should be reduced as speed increases, so that at full speed the motor actually receives full power. Also, a slight grade-dependent speed change is often considered more prototypical.
Locomotives operated in consists should never run at 100% load compensation in any part of the speed range, because it causes the locomotives to fight each other and could even lead to derailments.
The overall intensity of load compensation can be defined with CV # 58 from no
compensation (value 0) to full compensa­tion (value 255). Useful values range from 100 to 200.
For a more precise or more complete load compensation over the full speed range use CV #10 and CV #113 together with CV #58 to define a 3-point curve.
Page 24 Large-scale Decoder & Sound Decoder MX695/6/7/9
CV
Designation
Range
Default
Description
#151
Motor Brake
0 - 9
0
= 0: Brake not active
= 1 … 9: The motor brake is gradually actuated (over a period of 1, 2 … 8 seconds, up to full braking pow-
er by shorting both motor end stages) if the target speed is not held (not slowing down), even though the motor is no longer energized.
The higher the value, the faster and harder the brake is being applied.
Tens digit: 1-9: Reduction of the motor regulation if consist-key is active. The values 1-9 reduce the con­trol to 10%-90% of the value set in CV #58.
CV
Designation
Range
Default
Description
#3
Acceleration Rate
0 - 255
(2)
The value multiplied by 0.9 equals’ acceleration time in seconds from stop to full speed.
The effective default value for sound decoders is usu­ally not the value given here, but is determined by the loaded sound project.
#4
Deceleration Rate
0 - 255
(1)
The value multiplied by 0.9 equals’ deceleration time in seconds from full speed to a complete stop.
The effective default value for sound decoders is usu­ally not the value given here, but is determined by the loaded sound project.
#23
Acceleration
Trimming
0 - 255
0
To temporarily adapt the acceleration rate to a new load or when used in a consist. Bit 0 - 6: entered value increases or decreases acceleration time in CV #3.
Bit 7 = 0: adds above value to CV #3. = 1: subtracts above value from CV #3.
#24
Deceleration
Trimming
0 - 255
0
To temporarily adapt the deceleration rate to a new load or when used in a consist. Bit 0 - 6: entered value increases or decreases deceleration time in CV #4.
Bit 7 = 0: adds above value to CV #4. = 1: subtracts above value from CV #4.
#121
Exponential
Acceleration
0 - 99
0
Acceleration time (momentum) can be stretched in the lower speed range:
Tens digit: Percentage of speed range to be included (0 to 90%). Ones digit: Exponential curve (0 to 9).
EXAMPLE: CV #121 = 11, 23 or 25 are typical initial test values.
#122
Exponential
Deceleration
0 - 99
0
Deceleration time (momentum) can be stretched in the lower speed range:
Tens digit: Percentage of speed range to be included (0 to 90%). Ones digit: Exponential curve (0 to 9).
EXAMPLE: CV #122 = 11, 23 or 25 are typical initial test values.
#123
Adaptive
Acceleration and De-
celeration
0 - 99
0
Raising or lowering the speed to the next internal step occurs only if the preceding step is nearly reached. The tolerance for reaching the preceding step can be defined by this CV (the smaller this value the smooth­er the acceleration/deceleration)
Value = 0: no adaptive acceleration or deceleration Tens digit: 0 - 9 for acceleration
Ones digit: 0 - 9 for deceleration = 11: strongest effect; sometimes makes the start im-
possible (engine won’t move)
#394
Bit 4: Quicker accel-
eration
From SW-Version
0 - 255
-
Bit 0 = 1: Light flashes at switch gear sound.
Bit 4 = 1: Quicker acceleration with sound playing back heavy load when speed regulator is moved
The Motor Brake
This brake is useful for vehicles without worm gears to prevent them from rolling away on inclines, picking
up speed on declines as well as to prevent a heavy train from pushing a standing engine downhill.
5.7 Acceleration and Deceleration:
The basic acceleration and deceleration times (momentum) are set with
CV’s #3 and #4
according to the relevant NMRA standard, which demands a linear progression (the time be­tween speed step changes remains constant over the whole speed range). For simple smooth drivability use values 3 or higher but for really slow starts and stops start with a value of 5. Values over 30 are rarely practical!
A sound project in sound decoders always comes with different values in CV’s #3 and #4 (as well
as many other CV’s) than what is listed in the CV charts. Often the sound can only be played
back correctly in conjunction with the acceleration times provided by the sound project (or certain
minimum values), so the sound project’s default values should therefore not be changed too
much. Acceleration and deceleration behavior, especially starting and stopping, can be further im-
proved by the “exponential” and “adaptive” acceleration/deceleration features (CV’s #121, 122
and 123). To eliminate a start-up jolt after changing the direction, caused by gear backlash in gearboxes,
use CV #146: Some free play between gears of a drivetrain is essential to prevent them from binding. This creates backlash and may be more severe on some engines than on others, especially when fitted with a worm gear or an excessively worn gearbox. Excessive backlash leads to a peculiar behavior especially after changing the direction: When
the motor starts turning in the opposite direction it doesn’t move the engine right away because
it has to eliminate the backlash first. And to make matters worse, the motor starts to accelerate already during this phase. When the engine finally starts moving, the motor’s speed has ex- ceeded the normal start-up rpm, which results in an unpleasant jolt. This can be avoided with the help of CV #146.
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 25
CV
Designation
Range
Default
Description
33.25
rapidly to full speed.
Bit 5 = 1: Overlapping of chuff beats
#309
Brake key
From SW-Version
33.25
0 - 28
0
The key defined here starts a braking the engine ac­cording to the brake time defined in CV #349 (the normal – higher – deceleration time in CV #4 is being ignored.
#349
Deceleration time for
brake key
From SW-Version
33.25
0 - 255
0
For the desired effect to work, the normal deceleration time in CV #4 must be set to a very high value (i.e.
50…250) and the deceleration time in CV #349 to a rather low value (i.e. 5…20).
Moving the speed regulator to 0 with these settings simulates a coasting effect while pressing the brake key brings to engine to a rapid stop.
#146
Compensation for
gear backlash
during direction chang-
es in order to reduce
start-up jolts
0 - 255
0
= 1 to 255: the motor spins at minimum rpm (accord­ing to CV #2) for a specific time and only starts to ac­celerate after this time has elapsed. This CV will only be executed after a direction change.
How much time is required to overcome the backlash depends on various circumstances and can only be determined by trial and error. Typical values are:
= 100: the motor turns about 1 revolution or a maximum of 1 second at the minimum speed.
= 50: about ½ a turn or max. ½ second. = 200: about 2 turns or max. 2 seconds.
Important: The minimum speed must be set correctly, so that the motor actually turns at the speed step de­fined as the lowest step in CV #2. Also, CV #146 is only useful if the load regulation is set to maximum or at least close to it (i.e. CV #58 = 200 – 255).
CV
Designation
Range
Default
Description
#135
km/h –
speed regulation
activating, control and
range definition
2 - 20
0
= 0: km/h – regulation turned off; the “normal” speed regulation is in effect.
“Pseudo-Programming” („Pseudo“ = programmed val­ue is not being stored):
CV #135 = 1 Initiates a calibration run (see above) Continue with “normal“ programming of CV #135 (pro-
grammed value will be stored): = 10: each step (1 to 126) represents
1 km/h: that is step 1 = 1 km/h,
A CALIBRATION RUN must be performed with each engine:
First, we need to determine the calibration distance: a section of track that measures 100 scale meters (plus the necessary acceleration and deceleration distances before and after), of course without inclines, tight radii and other obstacles; for example, for HO (1:87) 115cm; for G-scale (1:22.5) 4.5m. Mark the start and end points of the calibration section.
Step 1. Set the engine on the track, with the proper travel direction selected, about 1 to 2 me-
ters (3 – 6 ft) before the start marker and the function F0 (headlights) turned off. Ac­celeration times (in CV #3 of the decoder as well as settings in the cab) should be set to 0 or a very small value.
Step 2. Start the calibration mode by programming CV #135 = 1 (operations mode program-
ming). This is a pseudo-programming because the value of 1 does not replace the val­ue already stored in CV #135.
Step 3. Set the speed regulator to a medium speed position (1/3 to ½ of full speed); the loco
accelerates towards the start marker.
Step 4. As the engine passes the start marker, turn on the function F0 (headlights); turn F0
off again when passing by the end marker. This ends the calibration run and the loco may be stopped.
Step 5. CV #136 can now be read out for checking purposes. The calibration “result” stored in
that CV doesn’t mean very much by itself. If however, several calibration runs are per­formed, the value in CV #136 should approximately be the same every time, even if the traveling speed was different.
Note: The actual acceleration and deceleration rates for HLU brake sections (ZIMO signal controlled speed influence) are also determined by CV #49 and #50.
The momentum (acceleration and deceleration rates) according to CV #3 and #4 refers to the 255 internal steps which are spaced equally from 0 to full speed. The selected speed table, whether 3­step or 28-step, does not influence the momentum behavior.
The momentum CANNOT be changed by bending the speed curve in the speed tables, but is very much possible with the “exponential acceleration/deceleration” in CV #121 and #122.
5.8 Special Operating Mode “km/h – speed regulation
The km/h (Kilometer per hour) speed regulation is an alternative method of driving with proto­typical speeds in all operating situations: the cab’s speed steps (1 to 126 in the so-called “128 speed step mode”) will be directly interpreted as km/h. However, ZIMO decoders do not simply convert the speed steps to a km/h scale but rather en­sure that the desired speed is held, by recalculating the already traveled distance and auto­matically make the necessary adjustments.
Momentum – explained in more detail:
Km/h Speed Regulation in Operation:
CV # 135 controls the selection between “normal” or km/h operation: CV # 135 = 0: The engine is controlled in “normal” mode; a possible km/h calibration run per-
formed earlier has no effect but the calibration results remain stored in CV #136. CV #135 = 10, 20 or 5: each external speed step (1 to 126) becomes
1 km/h, 2 km/h or 0.5 km/h: see CV table below! The speed regulation in km/h is not just useful for direct throttle control, but also for speed lim-
its through the “signal controlled speed influence” (CV’s 51 – 55). The values entered to those CV’s are also being interpreted in km/h.
Page 26 Large-scale Decoder & Sound Decoder MX695/6/7/9
step 2 = 2 km/h, step 3 = 3 km/h… = 20: each step represents 2 km/h;
step 1 = 2 km/h, step 2 = 4 km/h, last step 126 = 253 km/h.
= 5: each step represents .5 km/h; step 1 = .5 km/h, step 2 = 1 km/h, last step 126 = 63 km/h.
#136
Km/h –
Speed regulation -
Control number
read-out
or
speed setting confir-
mation
Calibration
run
or
RailCOm
read-out
factor
Read
value
128
A numeric value can be read-out after a successful calibration run, which was used to calculate the speed. It should remain unchanged (or vary only slightly) even after multiple calibration runs.
or correction factor for speed confirmation via RailCom
or other method of bidirectional communication.
CV
Designation
Range
Default
Description
CV
Designation
Range
Default
Description
#49
Signal controlled
(HLU)
acceleration
0 - 255
0
Entered value multiplied by .4 equals acceleration
time in seconds from stop to full speed
when:
“ZIMO signal controlled speed influence” with ZIMO
MX9 track section module or successor
or
“asymmetrical DCC signal” method (Lenz ABC) is
employed
#50
Signal controlled
(HLU)
deceleration
0 - 255
0
Entered value multiplied by .4 equals deceleration time in seconds from full speed to complete stop when:
“ZIMO signal controlled speed influence” with ZIMO MX9 track section module or successor or
“asymmetrical DCC signal” method (Lenz ABC) is
employed
#51 #52 #53 #54 #55
Signal dependent
(HLU) speed limits
#52 for “U”, #54 for “L”, #51, 53, 55 for intermediate steps
0 - 255
20 40 (U) 70 110 (L) 180
ZIMO “signal controlled speed influence” method
(HLU) using MX9 or successor: Defines the internal speed steps for each of the 5
speed limits generated via HLU.
#59
Signal dependent
reaction time
0 - 255
5
ZIMO signal controlled speed influence (HLU) with ZIMO MX9 track section module or future module
or
when using the “asymmetrical DCC signal” stopping
method (Lenz ABC): Time in tenth of a second until the locomotive starts to
accelerate after receiving a higher signal controlled speed limit command.
Mph (miles per hour) instead of km/h:
Extending the calibration distance accordingly results in a mph speed regulation!
5.9 The ZIMO signal controlled speed influence (HLU)
ZIMO digital systems offer a second level of communication for transmitting data to vehicles in
specific track sections. The most common application for this is the “signal controlled speed in- fluence” for stopping trains and applying speed limits in 5 stages, with data sent to the track
sections as needed in the form of HLU cut-outs prepared by MX9 track section modules or its successors. This feature only operates within ZIMO systems.
If the “signal controlled speed influence” is being used (only possible within a ZIMO system), the speed limits “U” and “L” (and the intermediate steps if needed) can be set with configura- tion variables CV’s #51 to #55 as well as acceleration and deceleration values (momentum)
with CV #49 and #50. Please note that the signal controlled acceleration and deceleration times in CV #49 and #50
are always added to the times and curves programmed to CV #3, 4, 121, 122 etc. Signal con­trolled accelerations and decelerations compared to cab controlled momentum can therefore only progress either at the same rate (if CV #49 and #50 is not used) or slower (if CV #49 and/or #50 contain a value of >0), but never faster.
In order to have a properly functioning train control system using the signal controlled speed influence, it is important that all tracks are laid out correctly, especially the stopping and pre­braking/deceleration sections of the track. Please consult the MX9 instruction manual.
It is of utmost importance for a flawlessly working train control system using the signal con­trolled speed influence that the stop and related brake section lengths are arranged properly and consistently everywhere on the layout. Please consult the MX9 instruction manual.
The deceleration (often CV #52 for “U” limit) and brake (CV #4 and #50) characteristics should
be set so that all locos come to a complete stop within about 2/3 of the stop section, which in large-scale is typically 2’ - 2 ½’ before the end of a stop section. Setting the loco up to stop precisely within the last inch of a stop section is not recommended.
5.10 “Asymmetrical DCC-Signal” stops (Lenz ABC)
The “asymmetrical DCC signal” is an alternative method for stopping trains at a “red” signal. A simple circuit made up of 4 or 5 commercially available diodes is all that is required.
Usually 3 - 5 diodes in series plus one
Schottky diode in parallel in opposite direction is connected to the stop sec-
tion. The different voltage drops across the diodes results in an asymmetry of about 1 to 2V. The direction in which the diodes are mounted determines the po­larity of the asymmetry and with it the driving direction a signal stop is initiated.
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 27
CV
Designation
Range
Default
Description
#27
Position dependent
stops
with asymmetrical DCC
signal
(Lenz “ABC” method)
0, 1, 2, 3
0
Bit 0 = 1: Stops are initiated if voltage in right rail is higher than left rail (in direction of travel). This setting, CV #27 = 1, IS THE COMMON APPLICTION for this feature (provided the decoder is wired to the rail correctly).
Bit 1 = 1: Stops are initiated if voltage in left rail is higher than right rail (in direction of travel).
Stopping is directional if only one of the two bits is set (not both). Traveling in the opposite direction will have no effect. Use the other bit In case the train stops in the wrong direction!
Bit 0 and Bit 1 = 1 (CV #27 = 3): Stops in both directions, regardless of rail polarity.
#134
Asymmetrical
threshold
for stopping with
asymmetrical
DCC signal
(Lenz ABC method)
1 - 14, 101 - 114,
201 - 214
=
0,1 - 1,4 V
106
Hundredths digit: Sensitivity adjustment, changes the speed with which the asymmetry is being recognized.
= 0: fast recognition (but higher risk of errors, i.e. unreliable stopping).
= 1: normal recognition (approx. 0.5 sec), fairly reliable (default).
= 2: slow recognition (approx. 1 sec), very reliable
Tens and ones digit: Asymmetrical threshold in tenths of a volt. The voltage difference between the two half waves of the DCC signal defines the minimum re­quired to be recognized as asymmetrical that starts the intended effect (usually braking and stopping of a train).
= 106 (Default) therefore means 0.6 V. This value has proven itself to be appropriate under normal condi­tions; by using 4 diodes to generate the asymmetry.
#142
High-speed correction
for the ABC
asymmetrical stop
method
0 - 255
12
A delayed recognition (see CV #134), but also unreli­able electrical contact between rails and wheels, have a larger effect on a stop point at higher speeds than at lower speeds. This effect is corrected with CV #142.
= 12: Default. This setting usually works fine if CV #134 is also set to default.
CV
Designation
Range
Default
Description
#29, #124, #112
Single Bits in each of
these CV’s are
responsible for the
correct reaction to the DC and Märklin brake
sections.
-
-
When using track-polarity dependent DC brake sections set
CV #29, Bit 2 = “0” and CV 124, Bit 5 = “1”! For polarity independent DC braking (Märklin brake
sections) set CV #29, Bit 2 = “0” and CV 124, Bit 5 = “1” and
additionally CV #112, Bit 6 = “1”!
CV
Designation
Range
Default
Description
#140
Distance controlled
stopping
(constant stopping dis-
tance)
Select a braking
method
and braking process
0 - 255
0
Activates distance controlled stopping as per CV #141 instead of time-constant braking according to CV #4.
= 1: automatic stops with ZIMO HLU (signal controlled speed influence) or ABC (asymmetrical DCC signal).
= 2: manual stops using the cab. = 3: automatic and manual stops. The start of braking is delayed in all cases above (= 1,
2 or 3) when the train travels at less than full speed, to prevent unnecessary long “creeping” (recommend­ed). On the other hand:
= 11, 12, 13 same meaning as above, but braking always starts immediately after entering the brake
The asymmetrical DCC signal stop mode needs to be activated in the decoder with CV #27. Normally Bit 0 is set, that is CV #27 = 1, which results in the same directional control as the “Gold” decoder from Lenz.
The asymmetrical threshold (0.4V by default) can be modified with CV #134 if necessary (i.e. if the DCC signal of a given command station is already offset to begin with). At the time of this
writing, the “asymmetrical DCC signal” has not been standardized and many DCC systems
pay no attention to this feature.
NOTE: ZIMO decoders do not support the usual ABC slow speed step as used by Lenz (with Lenz-Module BM2 for instance).
5.11 DC Brake Sections (Märklin brake mode)
These are the “classic” methods of automated layout control or stopping at a “red” signal. The required settings for ZIMO decoders are spread over several CV’s.
5.12 Distance Controlled Stopping -
Constant Stopping Distance
After the type of constant stopping method has been selected with CV #140 (= 1, 2, 3,
11, 12, 13), the stopping distance will be kept as close as possible to the one defined in
CV #141,
independent of the speed at the start of the braking procedure. This method is especially suitable in connection with automated stops in front of a red signal
(CV #140 = 1 or 11) with the help of the ZIMO HLU signal controlled speed influence or the Lenz ABC asymmetrical DCC-signal (see above).
Although of lesser practical value, distance controlled stopping for manual driving can also be activated (by programming CV #140 with appropriate values of 2, 3, 12, or 13), which is exe­cuted whenever the speed is set to 0 (by the cab, throttle, computer...).
Page 28 Large-scale Decoder & Sound Decoder MX695/6/7/9
section.
#141
Distance controlled
stopping
(constant stopping dis-
tance)
Setting the distance
0 - 255
0
This CV defines the “constant stopping” distance. The
right value for the existing stop sections has to be de­termined by trial.
Use these figures as a starting point: CV #141 = 255 is about 500m (500 yards) for a real train or 6m (18 ft) in HO. CV #141=50 about 100 m (100 yards) for a real train or 1.2m in H0 (4 ft.). Use the appropriate scale factor for other scales.
#142
High-speed compen-
sation
using the ABC method
0 - 255
12
A delayed recognition (see CV #134), but also unreli­able electrical contact between rails and wheels, have a larger effect on a stop point at higher speeds than at lower speeds. This effect is corrected with CV #142.
= 12: Default. This setting usually works fine if CV #134 is also set to default.
#143
compensation us-
ing the HLU method
0 - 255
0
The HLU method is more reliable than the ABC meth­od; no recognition delay is usually required in CV #134; this CV can remain at default value 0.
CV
Designation
Range
Default
Description
#124
Shunting key
functions:
Low gear
and
Momentum reduction
or deactivation
NOTE:
Further selection for
shunting keys in
CV’s #155, 156
Bits
0 - 4, 6
0
Select a function key for LOW GEAR ACTIVATION:
Bit 4 = 1 (and Bit 3 = 0): F3 as half-speed key Bit 3 = 1 (and Bit 4 = 0): F7 as half-speed key
Select a function key for MOMENTUM DEACTIVATION:
Bit 2 = 0 (and Bit 6 = 0): “MN” key for deactivation, Bit 2 = 1 (and Bit 6 = 0): F4 key for deactivation Bit 6 = 1 (Bit 2 is irrelevant): F3 for deactivation.
Effect of above key (MN, F3 or F4) on MOMENTUM:
Bit 1, 0 = 00: no effect on momentum = 01: removes momentum of CV #121 + #122 = 10: CV #3 + #4 reduced to ¼. = 11: removes all momentum above.
EXAMPLES: F3 for half speed-key: CV #124 = 16. F3 for half speed-key and F4 to remove momentum
completely: Bits 0, 1, 2 & 4 = 1; that is CV #124 =23. F3 for half-speed key and removing momentum:
“Distance controlled stopping“, when activated, is exclusively applied to decelera- tions leading to a full stop, but not to speed reductions without stopping (these are still handled by CV #4). Neither is there any influence to acceleration events.
The traveled distance is constantly being recalculated in order to get as close as possible to the desired stop point. The deceleration rate within distance controlled stopping is always ap­plied exponentially, that is the deceleration rate is high in the top speed range followed by gen­tle braking until the train comes to a full stop; which in this case is not governed by CV #122! The application of CV #121 for exponential acceleration however remains unchanged.
5.13 Shunting, Half-Speed and MAN Functions
On the one hand, defining the different Configuration Variables (#3, 4, 121, 122 and 123) of­fers prototypical acceleration and deceleration behavior, but is on the other hand often obstruc­tive for quick and easy shunting.
This is why the momentum can temporarily be reduced or eliminated altogether with a function key of your choice. Also, during shunting maneuvers it is sometimes helpful to cut the speed range of the throttle in half.
The distance controlled stopping can take place in two possible ways; see diagram below: The first is the recommended method (CV #140 = 1, 2 ,3), where a train entering at less than full speed continues at the same speed for some time before it starts braking at a “normal” decel­eration rate (same rate as would be applied at full speed).
In the second method (CV #140 = 11, 12, 13), the train immediately starts braking when enter­ing the stop section, even when entering at a lower speed, which may lead to an un­prototypical behavior. It may however be useful to use this method if used together with de­coders from other manufacturers that do not have the capability mentioned above, in order to harmonize the brake sequences. The second method may also be the preferred method if distance controlled stopping is used manually (CV #140 = 2 or 12), so that the train reacts immediately to speed changes from the throttle.
First method for a constant stopping distance
Second method for a constant stopping distance
For historical reasons, the assignments of these "shunting-key functions" are summarized in
CV #124, which is associated with restrictions and also relatively confusing.
From today’s perspective, CV's #155, #156 and #157 are the preferred CV’s for these set- tings, where function keys can be selected in a systematic and unlimited manner for each of the shunting and MAN functions. However, Bits 0 and 1 in CV #124 still need to be set for the desired momentum deactivation effect, even if the relevant keys are defined with CV’s #155 -
157.
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 29
Bit 5
DC stopping
Bits 0, 1, 4 &6 = 1; that is CV #124 = 83.
Bit 5 = 1: ”DC stopping“
#155
Half-speed key
selection
0 - 28
0
Expanding on the settings of CV #124; if another key is required than F3 or F7:
CV #155: Defines a function key for half-speed activa­tion (= top speed cut in half).
If a key is assigned through CV #155, a possible as­signment through CV #124 is void.
CV #155 = 0 doesn’t mean that the F0 key is assigned
but rather that the setting in CV #124 is active.
#156
Momentum-
deactivation key
selection
0 - 28
0
Expanding on the settings of CV #124; if another key than F3, F4 or MAN is required for momentum deacti­vation:
CV #156: Defines the function key that deactivates or reduces the acceleration and deceleration times in CV’s #3, 4, 121 and 122.
Whether the momentum is deactivated or reduced and by how much is still defined in CV #124:
CV #124, Bit 1, 0: = 00: no effect on momentum = 01: removes momentum of CV #121 + #122 = 10: CV #3 + #4 reduced to ¼. = 11: removes all momentum.
In order to deactivate all momentum, CV #124 is typically set to a value of 3 (the value may be different if other Bits in CV #124 are also set).
A possible key assignment for momentum deactivation in CV #124 remains inactive if CV #156 > 0.
#157
Selects a function
key for the MAN
function
Only needed for non-
ZIMO
cabs that don’t have
the MN key.
0 - 28
0
The MAN function (or MAN key on ZIMO cabs) was originally designed for ZIMO applications only, in order to cancel stop and speed limit commands applied by the signal controlled speed influence system (HLU).
This function was expanded in later software versions
to include “asymmetrical DCC signal stops” (Lenz
ABC). If ZIMO decoders are used with non-ZIMO systems, a
function key can now be assigned with CV #157 to cancel a signal controlled speed limit or stop com­mand.
Function
key
Numerical
Key
on
ZIMO
throttle
CV
Additional
Function Outputs
for Models
MX695KV, MX695LV
Function Outputs
of all MX695
Models
FO12
FO11
FO10
FO9
FO8
FO7
FO6
FO5
FO4
FO3
FO2
FO1
rear light
front
light
F0
1 (L) forward
# 33 7 6
5
4 3 2 1 0
F0
1 (L) reverse
# 34 7 6
5
4 3 2
1
0
F1 2 # 35 7 6
5
4 3 2 1 0
F2 3 # 36 7 6
5
4
3 2 1 0 F3 4 # 37 7 6 5 4 3
2
1 0
F4 5 # 38 7 6 5 4 3
2
1 0
F5 6 # 39 7 6 5 4 3
2
1 0
F6 7 # 40 7 6 5
4 3 2
1 0
F7 8 # 41 7 6 5 4 3 2 1 0
F8 9 # 42 7 6 5 4
3 2 1 0
F9 0 # 43 7 6 5 4 3 2 1 0
F10
1
# 44 7 6
5 4 3 2 1 0
F11
2
# 45 7 6 5 4 3 2 1 0
F12
3
# 46
7 6 5 4 3 2 1 0
5.14 The NMRA-DCC function mapping
ZIMO large-scale decoders have 8 or 14 function outputs (FO). The loads connected to these outputs (head lights, smoke generators, etc.) are turned on or off using the function keys on the cab (throttle). Which function key controls which function output can be specified with the NMRA function mapping
CV‘s #33 to #46
Unfortunately, this function mapping also has its limitations (only one 8-Bit register is available for each function, which leaves only 8 outputs to select from) and the headlight is the only function that can switch with direction.
The black dots in the table above indicate the default settings at the time of delivery, where each function key corresponds to the same numbered function output. Therefore the following values were written to the configuration variables: CV # 33 = 1 CV # 34 = 2 CV # 35 = 4 CV # 36 = 8 CV # 37 = 2 CV # 38 = 4 CV # 39 = 8 CV # 40 = 16 CV # 41 = 4 etc.
Page 30 Large-scale Decoder & Sound Decoder MX695/6/7/9
F2 3 # 36
7 6
5 4 3 2 1
0
F3 4 # 37
7 6 5 4 3 2 1 0
F4 5 # 38
7
6 5 4 3 2 1 0
F0
1 (L) for
# 33
7 6 5 7 6 5 7 6 5
7 6 5
7 6 5
4 3 2 1 0
F0
1 (L) rev
# 34 7 6
5
4 3 2
1
0
F1 2 # 35 7 6
5
4 3 2 1 0
F2 3 # 36 7 6
5
4
3 2 1
0
F3 4 # 37 7 6
5
4
3
2 1 0
F4 5 # 38 7 6
5
4 3 2 1 0
F5 6 # 39
7
6
5
4 3 2 1 0
F6 7 # 40
7 6 5
4 3 2 1 0
F7 8 # 41 7 6
5
4 3 2 1 0
F8 9 # 42 7 6
5
4 3 2 1 0
EXAMPLE of a function mapping modification: The F2 key (ZIMO #3 key) should switch in ad­dition to output FO2 also output FO4. Moreover, F3 and F4 should NOT switch FO3 and FO4 but rather FO7 and FO8 (this could be couplers, for example). New values are to be entered into the relevant configuration variables as follows:
CV # 36=40 CV # 37 = 32 CV # 38 = 64
5.15 The modified NMRA Function mapping
Since the original NMRA function mapping does not allow for some desirable configurations, an extension is offered by ZIMO decoders, which is described on the following pages. Most of these options are related to the special ZIMO
CV #61
Note: Some of the CV #61 variations (1, 2, 3…) have been replaced over the years by other more practical applications.
Programming
CV #61 = 97 offers an Alternative “function mapping” without left shifts:
CV #61 = 97 abolishes the left shift of higher CV’s (#37 and up, according to the original
NMRA function mapping), which allows higher function keys to be mapped with lower function outputs (i.e. Function output 1 (FO1) cannot be mapped with function key F4 using the NMRA function mapping, but is possible with the ZIMO extended mapping).
FO6 FO5 FO4 FO3 FO2 FO1 Rear Front
Light Light
NOTE: The earlier options CV #61 = 1, 2, 11…15 as well as CV #61 = 98 were dis- continued with SW-Version 34 and replaced with the “Swiss Mapping“ (see next chapter).
Tip: Directions dependent taillights with special effect CV’s:
With the NMRA function mapping it is only possible to have function F0 directional and was in­tended for the headlights, so they automatically switch between “front” and “rear” when chang­ing direction. All other functions are controlled independent of direction.
The special effect CV’s #125 … 132, #259 and #160 (see chapter “Special function output ef- fects”), each assigned to a function output (up to FO8), make it possible to have more direction dependent functions. To utilize the directional capabilities of these CV’s use only the direction-
al Bits (0 or 1) without the actual effect Bits. Example 1: A couple of red taillights are connected to function outputs FO1 and FO2 (front
and rear of engine). Both are to be actuated with F1 but should also change with direction. This requires the following CV settings:
CV #35 = 12 (Bit 2 for FO1 and Bit 3 for FO2), as well as CV #127 = 1 (for FO1) and CV #128 = 2 (for FO2).
Therefore FO1 is only activated in forward direction and FO2 only in reverse, and only if the function is turned ON with the function key F1.
Example 2: Contrary to example 1 where the red taillights were switched independent from the white headlights, in this example the headlights and taillights are switched ON/OFF together at the proper end of the locomotive with F0 or F1 (depending on which end the loco is coupled to the train).
This can be done as follows: Connect: White front headlights connected to function output “front headlights” Red front taillights to function output FO2 White rear headlights to function output FO1 Red rear taillights to function output “rear headlights” (!).
CV #33 = 1 and CV #34 = 8 front white headlights on F0forw and front red taillights on F0rev! CV #35 = 6 (both white headlights as well as red taillights in the rear on F1!)
CV #126 = 1 / CV #127 = 2 (Direction dependence for rear white and red lights by means of “Special Effects” CV).
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 31
CV
Designation
Range
Default
Description
#107
Light suppression
(i.e. front headlights AND additionally de­fined function output)
at
cab side 1 (front)
0 - 255
0
The value of this CV is calculated as follows:
The number of a function output (FO1…FO28) x 32 + number of a function key (F1, F2…F28)
= Value of CV #107
Function Key: The key (F1…F28) which should turn off
ALL lights on the cab side 1 (front side) AND Function Output: i.e. taillights on the same side.
#108
Cab side 2 (rear)
0 - 255
0
Same as CV #107 but for other locomotive side.
#109
Additional FU-output, cab side 1
1 - 6
0
Fu-output turns off together with CV #107.
#110
Additional FU-output, cab side 2
1 - 6
0
Fu-output turns off together with CV #108.
5.16 “Unilateral Light Suppression”
This new feature (since SW version 30.7, expanded in 33.18), asked for by many users, makes it possible to switch off all lighting on one side of a locomotive with the push of one function key (usually on the “train side”, i.e. where cars are coupled to the locomotive).
Page 32 Large-scale Decoder & Sound Decoder MX695/6/7/9
CV
Designation
Range
Default
Description
#430
Swiss Mapping Group 1
“F-Key”
0 - 28,
29 (for F0)
0
The key defined here switches the function outputs listed under
A1 (forward or reverse) or A2 (forward or reverse) ON or OFF. 1 – 28 for function keys F1 – F28, F29 is for F0.
#431
Swiss Mapping Group 1
“M-Key”.
or
Special high-beam
setting
(from SW version 34)
Bit 0 - 6:
0 - 28,
29 (for F0)
and
Bit 7
or 255
0
The “normal function mapping” for the “M-key” de­fined here will be deactivated (that is the relevant outputs such as the headlights for example) when the “F-key” is switched on.
Bit 7 = 1: additionally, the outputs listed under A1 and A2 should only switch ON if the F and M key is ON.
= 157: is an often used value for CV #431, because F0 (= 29) is usually selected as the “M-key” with Bit 7 = 1. F0 then acts as a general ON/OFF key.
= 255 (Special high-beam setting!): the Fu-Outputs
defined in the following four CVs are switched to full intensity, provided that they are controlled via the "normal function mapping", and dimmed with CV # 60; this function is used, for example, to switch the headlights of a Swiss locomotive to high-beam, with­out switching the white taillight to high-beam. Depending on CV #399 setting (see also below): Switches to high-beam only when speed is higher than value given in this CV (in 255 speed steps).
#432
Swiss Mapping Group 1
“A1” forward
1 - 12
14 (FO0f)
15 (FO0r)
0
Function output to be turned ON in forward direction under the conditions set out for the “F” and “M” keys.
#433
Swiss Mapping Group 1
1 - 12
14 (FO0f)
0
Additional function output to be switched ON in for­ward direction under the conditions set out for the “F”
“A1” forward
15 (FO0r)
and “M” keys.
#434
Swiss Mapping Group 1
“A2” reverse
1 - 12
14 (FO0f)
15 (FO0r)
0
Function output to be turned ON in reverse direction
under the conditions set out for the “F” and “M”
keys..
#435
Swiss Mapping Group 1
“A2” reverse
1 - 12
14 (FO0f)
15 (FO0r)
0
Additional function output to be switched ON in re­verse direction under the conditions set out for the “F” and “M” keys.
#436 -
441
. . . Group 2.
. . .
0
All 6 CV’s of Group 2 are defined the same way is the 6 CV’s in group 1.
#442 -
447
. . . Group 3.
. . .
0
All 6 CV’s of Group 2 are defined the same way is the 6 CV’s in group 1.
#448 -
453
. . . Group 4.
. . .
0
. . .
#454 -
459
. . . Group 5.
. . .
0
. . .
#460 -
465
. . . Group 6.
. . .
0
. . .
#466 -
471
. . . Group 7.
. . .
0
. . .
#472 -
477
. . . Group 8.
. . .
0
. . .
#478 -
483
. . . Group 9.
. . .
0
. . .
#484 -
489
. . . Group 10
. . .
0
. . .
#490 -
495
. . . Group 11.
. . .
0
. . . (Groups 11, 12, 13 with SW version 34 or higher)
#496 -
501
. . . Group 12.
. . .
0
. . .
#502 -
507
. . . Group 13.
. . .
0
. . .
#399
Speed dependent
headlights
(Rule 17)
0 - 255
0
In conjunction with the “Swiss Mapping’s” special setting “high-beam”, see CV #431 = 255; applies to
each of the 13 CV groups (CV #437, 443..): High-beam only turns on when the speed exceeds the value in this CV; based on the decoder internal 255 speed steps. EXAMPLE: = 0: High-beam at any speed (incl. stand-still), con­trolled only by the F-key (i.e. as per CV #430). =1: High-beam only while driving (OFF at stand-still), provided the defined F-key is ON. = 128: Switches to high-beam when reaching medi­um speed.
5.17 The “Swiss Mapping” (from SW version 32)
The “Swiss mapping” is a function mapping that allows the loco lighting to be operated as is required by Swiss locomotives, which is of course also useful for locos of other countries.
The purpose of the "Swiss mapping" is to switch the various states of the locomotive lighting with different function keys, i.e. for situations like driving a single locomotive, cars coupled on driver’s cab 1, or at the driver's cab 2, push-pull, shunting, etc.
Using this relatively complex method is of course only worthwhile if the vehicle is equipped with many independently connected lights (or LED’s) and the decoder offers as many function outputs, at least 6. ZIMO decoders offer indeed between 6 and 10 function outputs (with the exception of a few miniature decoders), large-scale decoders even more.
The desired lighting states are defined by a total of 13 CV groups, each group containing 6 CV’s (= 78 CV’s; CV #430 - #507). The principle is simple in itself, in that the first CV of each group contains the number (1 to 28) for a function key F1...F28, and the other CVs define which function outputs are to be switched on when pressing this key, each dependent on the direction of travel.
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 33
#33 = 133
#34 = 42
#430 = 15
#431 = 157
#432 = 14
#433 = 1
#434 = 15
#435 = 1
#436 = 15
#437 = 157
#438 = 2 .
#439 = 0
#440 = 2 .
#441 = 0
#442 = 16
#443 = 157
#444 = 14
#445 = 1
#446 = 2 .
#447 = 4
#448 = 17
#449 = 157
#450 = 5
#451 = 6
#452 = 15
#453 = 2
#454 = 18
#455 = 157
#456 = 6
#457 = 0
#458 = 4
#459 = 0
#460 = 19
#461 = 157
#462 = 2
#463 = 0
#464 = 1
#465 = 0
#466 = 20
#467 = 157
#468 = 0
#469 = 0
#470 = 0
#471 = 0
Functions, Keys
Outputs
Front
Rear
F0, forward
(Cab 1 forward)
Lfor FO1 FO6
Locomotive only
F0, reverse
(Cab 2 forward)
Lrev FO2 FO4
Locomotive only
F0 + F15,
forward
(Cab 1 forward)
Lfor FO1 FO2
Train, cars coupled at cab 2, standard train without pilot car.
F0 + F15,
reverse
(Cab 2 forward)
Lrev FO1 FO2
Train, cars coupled at cab 1, standard train without pilot car.
F0 + F16,
forward
(Cab 1 forward)
Lvor FO1
Train, cars coupled at cab 2, standard train with pilot car or first engine in a double header.
F0 + F16,
reverse
(Cab 2 forward)
FO3 FO4
Loco pushing, cars coupled to cab 2, with pilot car or first engine in a double header. (prototypical since 2000)
F0 + F17,
reverse
(Cab 1 forward)
Lrev FO2
Loco pulling, cars coupled to cab 1, train with pilot car or first eingine in a double header.
F0 + F17,
forward
(Cab 1 forward)
FO5 FO6
Loco pushing, cars coupled to cab 1, with pilot car (prototypical since 2000).
F0 + F18,
forward,
(Cab 1 forward)
FO6
Loco pushing, cars coupled to cab 1, with pilot car or last engine in a double header. (prototypical up to 2000)
F0 + F18,
reverse
(Cab 2 forward)
FO4
Loco pushing, cars coupled to cab 2, with pilot car or last engine in a double header. (prototypical up to 2000)
F0 + F19,
forward
(Cab 1 forward)
FO2
Loco pulling as last engine in consist, cars coupled to cab 2.
F0 + F19,
reverse
(Cab 2 forward)
FO1
Loco pulling as last engine in consist, cars coupled to cab 1.
F0 + F20,
forward/reverse
---
Engins(s) inside a consist
Front
Rear
Lfor
Lrev
FO1
FO2
FO3
FO4
FO5
FO6
The application of the “Swiss Mapping” is shown here with
the example of an SBB Re422 engine.
The function outputs together with the connected lights or groups of lights are shown here as they exist in a typical SBB (Swiss) electric locomotive.
The task of the “Swiss Mapping”, with the help of the function keys
F0 (General ON/OFF), and
F15, F16, F17, F18, F19 and F20,
is to correctly switch the lighs in all possible operating conditions (of course in both directions).
This results in the table on the right,  for which the Swiss Mapping CV’s are configured as follows:
Explanation: The normal NMRA function mapping in CV #33 and CV #34 (front and rear headlight) deter-
mines the lighting in case where F0 is ON and function keys F15 – F20 are OFF: CV #33 = 133 (= Lfor, FO1, FO6) and CV #34 = 42 (= Lrev, FO2, FO4).
The following CV groups (1. Group: CV #430 – 435, 2. Group: CV #436 – 441 etc.), each
group shown on one line, contain the “F-key” F15, F16, F17, F18, F19, F20 in the first CV of each row. Following that (in each group) are the CV’s for the “M-key” and function outputs to
be switched.
Note that there are two groups for F15 (CV #430… and #436…) because 3 function otuputs
are switched simultanesouly but only 2 can be entered per group (A1,A2 for each direction);
one group is sufficient for all other “F-Keys”. All “M-Keys” (the second CV in each group) are set to “157”; this means that “F0” and the con-
dition (of Bit 7) must be met and results in the outputs listed only be turned ON if the F and M key is ON.
The third to sixth CV’s in each group contain the numbers of the function outputs to be actuat- ed (where the headlights are coded with “14” and “15”, for all other outputs just use the digit in FO1, FO2…).
Page 34 Large-scale Decoder & Sound Decoder MX695/6/7/9
CV
Designation
Range
Default
Description
#400
Input-Mapping
for internal
F0
that is, which function
key switches the inter-
nal function F0?
0, 1 - 28, 29 30 – 187.
254, 255
0
= 0: Key F0 (that is, F0 received from the DCC-packet) is
forwarded to the internal (decoder) F0 (1:1).
= 1: Key F1 forwarded to the internal F0. ….. = 28: Key F28 forwarded to the internal F0. = 29: Key F0 forwarded to the internal F0. = 30: Key F1 to F0, only in forward direction.
….. = 57: Key F28 to F0, only in forward direction. = 58: Key F0 to F0, only in forward direction.
= 59: Taste F1 to F0, only in reverse direction. ….. = 86: Key F28 to F0, only in reverse direction. = 87: Key F0 to F0, only in reverse direction.
= 101: Key F1-inverted to internal F0 ….. = 187: Key F0- inverted from int. F0, in reverse dir. = 254: Directions Bit to internal F0, in forward dir. = 255: Directions Bit to internal F0, in reverse dir.
#401
-
#428
Input-Mapping
for internal
F1 … F28
0,
1 - 28,
29,
30 - 255
0
Same as input mapping above, but: CV #401 = 0: Key F1 to internal F1
= 1: Key F1 to internal F1 and so on.
CV
Designation
Range
Default
Description
#60
Reduced function
output voltage
(Dimming).
Affects all
function outputs.
0 - 255
0
Reduction of effective voltage on the function out­puts per PWM (pulse width modulation); Useful to dim headlights for instance
EXAMPLE VALUES: CV # 60 = 0: (equivalent to 255) full voltage
CV # 60 = 170 2/3 of brightness CV # 60 = 204: 80% brightness
#114
Dim mask 1
=
Excludes certain func­tion outputs from dim-
ming per
CV # 60
For higher function
outputs go to
CV #152
Bits
0 - 7
0
Enter function outputs that are not to be dimmed as per CV #60. These outputs will receive the full volt­age from the pin they are connected to that is, either full track voltage or low voltage from a low-voltage pin.
Bit 0 - front headlight, Bit 1 - rear headlight, Bit 2 - function output FO1, Bit 3 - FO2, Bit 4 - function output FO3, Bit 5 - FO4 Bit 6 - function output FO5, Bit 7 - FO6 Respective Bit = 0: Output will be dimmed to the value defined in CV #60.
Respective Bit = 1: Output will not be dimmed. EXAMPLE:
CV #114 = 60: FO1, FO2, FO3 and FO4 will not be dimmed; front and rear headlights will be dimmed according to CV #60.
#152
Dim Mask 2
(Excludes specific func-
tion outputs from dim-
ming as per CV #60)
Continuation of
CV #114
and
FO3, FO4 as direction
bit mapping
Bits
0 - 5
and
Bit 6,
Bit 7
0
0
… Continuation of CV #114. Bit 0 - function output FO7,
Bit 1 - function output FO8, Bit 2 - function output FO9, Bit 3 - function output FO10, Bit 4 - function output FO11, Bit 5 - function output FO12.
Bit 6 = 0: „normal“ = 1: Direction bit mapped to FO3 and FO4 that is, FO3 is switched on when driving in reverse and FO4 when driving forward (normal mapping for FO3 and FO4 is invalid when this Bit is set).
Bit 7 = 1: “Direction bit” for FO9 active in Fwd direc.
5.18 The ZIMO Input-Mapping“
SW versions 34 and up, also for outputs via SUSI
The NMRA function mapping limitations (only 8 functions to select from per function key) can be overcome with the ZIMO “input mapping”. In addition, the function keys (= external functions) can quickly be adapted to the wishes of the operator and that for both, function outputs and sound functions, without the need of changing internally mapped functions and especially
without changes to the sound projects: CV’s #400 … 428
to a low-voltage function output). Of course, this kind of voltage reduction is also interesting because it is easy to change at any time by changing the value in CV #60.
ATTENTION: Bulbs with voltage ratings as low as 12V can be dimmed with this PWM dimming
function without damage even if track voltages are considerably higher; but not bulbs rated be-
low that such as 5V or 1.2V bulbs. These must be connected to one of the decoder’s low-voltage supply pins instead of a “normal” positive pin (see chapter “Installation and Wiring”).
LED’s, on the other hand, always require a series resistor; if however, the resistor is designed to
operate at 5 V, the PWM dimming is also sufficient at a track voltage of 25V (in this case the set­ting would be CV #60 = 50, so a reduction by one fifth, 1/5th).
CV #60 affects all function outputs but specific outputs can be excluded from the dimming function using the dim mask CV’s (see table).
5.19 Dimming, Low beam and Direction Bits
Some things connected to function outputs may not always be operated with full track voltage, as is the case for example with 18V bulbs and a track voltage of 24V (quite common on large scale model railroads). Other times you simply want to reduce the brightness of the headlights.
The best solution in such cases is to connect the positive side of such devices to the low volt­age supply of the decoder (see chapter “Installation and wiring”). These outputs are fully stabi­lized so the voltage does not fluctuate with changes in track voltage.
Alternatively or in addition to this, the PWM voltage reduction is also available with
which defines the PWM duty cycle (Pulse With Modulation; the dimming is not only effective when a consumer is connected to the positive terminal with full track voltage, but also relative
CV #60,
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 35
CV
Designation
Range
Default
Description
#119
Low beam mask for F6
=
Output assignment for
(example) low/high
beam headlights
ATTENTION:
Certain settings in
CV #154 (Special out-
put configurations)
change the meaning of
CV’s #119 and #120
and therefore will no
longer be a low-beam
mask.
Bits
0 - 7
0
Selected outputs will dim, according to the dim value in CV #60, when the F6 key is actuated.
Typical application: Low/high beam Bit 0 - front headlight,
Bit 1 - rear headlight, Bit 2 - function output FO1, Bit 3 - function output FO2, Bit 4 - function output FO3, Bit 5 - function output FO4.
Respective Bit = 0: Output will not be dimmed, Respective Bit = 1: Output will be dimmed with F6 to value defined in CV #60.
Bit 7 = 0: normal action of F6. = 1: inverted action of F6.
EXAMPLE: CV #119 = 131: Function key F6 toggles headlights between low and high beam.
#120
Low beam mask for F7
Bits 0 - 7
Same as CV #119 but with F7 as low beam key.
CV
Designation
Range
Default
Description
#115
Uncoupler control
or
Second dim value
0 - 9
0
Only active if “uncoupler” function is selected (val- ue 48) in CV #125 …132, 159 or 160:
Tens digit = 0: when used for dimming applications Ones digit (0 to 9): PWM – voltage reduction
(0 to 90%)
#127
­#132 #159 #160
Effects on FO1, FO2,
FO3, FO4, FO5, FO6
on FO7, FO8
0 0
Value = 48 for dimming application #127 FO1 #128 FO2
#129 FO3 #130 FO4 #131 FO5 #132 FO6
#159 FO7 #160 FO8
CV
Designation
Range
Default
Description
#117
Flasher functions
Outputs are assigned
in
CV #118.
0 - 99
0
Duty cycle for flasher function: Tens digit = ON time / Ones digit = OFF time
(0 = 100msec, 1 = 200msec…..9 = 1 sec) Example: CV #117 = 55: Flashes evenly at 1 a second inter-
val.
#118
Flashing-Mask
=
Defines which outputs
operate as flashers.
Rhythm is defined in
CV #117
Bits
0 - 7
0
Selected function outputs will flash when turned ON. Bit 0 - front headlights
Bit 1 - rear headlights Bit 2 - function output FO1, Bit 3 - …FO2 Bit 4 - …FO3, Bit 5 - function output FO4.
Respective Bit = 0: No flasher Respective Bit = 1: Output flashes when turned ON.
Bit 6 = 1: FO2 flashes inverse! Bit 7 = 1: FO4 flashes inverse! (for alternate flashing, i.e. wig-wag)
EXAMPLE: CV #118 = 12: FO1 and FO2 are defined as flash-
ers. CV #118 = 168: Alternate flashing of FO2 and FO4, if both are switched on.
CV
Designation
Range
Default
Description
#112
Special ZIMO
configuration Bits
0 - 255
4 =
00000100
(i.e. Bits 4
and
7 = 0)
….
Bit 3 = 0: 12-Function mode = 1: 8-Function mode
Bit 4 = 0: Pulse chain recognition OFF = 1: Pulse chain recognition ON (use with old LGB systems)
Bit 7 = 0: No pulse chain generation = 1: Generates pulse chain commands for LGB sound modules.
Low/high beam with the help of the low beam mask
One of the function keys F6 (CV #119) or F7 (CV #120) can be defined as a low beam key. Selected function outputs can be dimmed as required with the function turned ON or OFF (in-
verted action with Bit 7).
A “second dim value” with the help of the uncoupler CV
If more function outputs need to be dimmed than CV #60 allows or if some function outputs re­quire a different voltage and the uncoupler function is not needed on the same vehicle then
CV #115
can be used for an alternative low voltage supply. The respective function outputs must be de­fined as “uncoupler output” in the corresponding CV’s #125…#132, #159 and #160 (see “Special effects for function outputs).
5.20 Flasher Effect
Flashing is actually a light effect just like all the others which are summarized in the CV’s start­ing with #125; but for historical reasons, CV’s #117 and #118 are used.
5.21 F1-Pulse Chains (Only for old LGB products)
NOTE: Dimming can also be achieved with the help of CV’s #137, 138 & 139 (see chapter 3.23)
Page 36 Large-scale Decoder & Sound Decoder MX695/6/7/9
CV
Designation
Range
Default
Description
#1251
Special effects
American lighting ef-
fects as well as others
such as uncoupler,
smoke generator and
more
on
function output F0
(front headlight)
Effects can be further
adjusted and modified
with
CV’s #62 - 64
and
CV #115, #116
(for uncoupler).
0
Bits 1, 0 = 00: bidirectional (active in both directions) = 01: only active in forward direction = 10: only active in reverse direction
ATTENTION in case of CV #125 and #126: change
CV’s #33, 34.... if direction is wrong!
Bits 7, 6, 5, 4, 3, 2 = Effect-Code
EXAMPLES
You want : Program CV #125 to: Mars
light forward only - 00000101 = 5 Gyralite independent of direction - 00011100 = 28 Ditch type 1 left, only forward - 00100101 = 37
Uncoupler - 00110000 = 48 Soft start of output - 00110100 = 52 Automatic stop light - 00111000 = 56
Automatic cab light OFF - 00111100 = 60 Auto. smoke OFF after 5 min – 01000000 = 64 Auto. smoke OFF after 10 min – 01000100 = 68 Speed/load depen. smoke - 01001000 = 72 Speed/load depen. diesel smoke - 01010000 = 80
#126
Special effects for
rear headlight
(default F0 reverse)
0
See CV #125 for details. #125 Front headlight #126 Rear headlight
#127
-
#132
Special effects for
FO1, FO2, FO3,
FO4, FO5, FO6
0
see CV #125 for details #127 FA1 #128 FA2
#129 FA3 #130 FA4 #131 FA5 #132 FA6
#159,
#160
Special effects for
FO7, FO8
0
see CV #125 for details #159 FA7 #160 FA8
#62
Effects modifications
0 - 9
0
Change of minimum dimming value
#63
Light effects modifica-
tion
or
Stop light OFF delay
0 - 99
0 - 255
51
Tens digit: sets cycle time (0 - 9, default 5), or start­up time during “soft start” with 001101 (0 - 0,9s)
Ones digit: extends OFF time For stop light OFF delay (001110xx in CV #125, 126
or 127): Time in tenths of a second the stop lights remain ON after the street car comes to a full stop (range: 0 – 25 sec.).
#64
Effects modifications
0 - 9
5
Ditch light off time modification
#64
Effects modifications
0 - 9
0
Bit 7 - 4: define a ditch light-key (function key+1)*16 consequent: 0=F2, 1=F0, 2=F1,.. 15=F14 Bit 3 - 0: Ditch light OFF time modification [s]
#393
ZIMO-Config. 5
0 – 255
0
Bit 0 = 1: activate ditch light if bell is played Bit 1 = 1: activate ditch light if horn is played
1
5.22 Special Effects for Function Outputs
(US and other light effects, smoke generator, uncouplers etc.)
Special effects can be assigned to a total of 10 function outputs with
CV’s #125, #126, #127 … #132, #159, #160
for F0fr., F0rear. FO1 ...... FO6 , FO7 , FO8
The values that can be programmed into the effect CV’s consist of
the 6-bit - effects code and the 2-bit - directions code
Bits 1,0 = 00: bidirectional (active in both directions) = 01: active in forward direction only (+ 1) = 10: active in reverse direction only (+ 2)
Bits 7 ... 2 = 000000xx No effect, except for direction = (0), 1, 2 (bidirectional, forward, reverse)
= 010110xx Slow fade in/out of a function output; useful for various = 88, 89, 90
The effect CV’s are also suitable without using a special effect (with effect code 000000), for
CV #127 = 1, CV #128 = 2, CV #35 = 12 (FO1, FO2 operate directional, ON/OFF with F1 key).
= 000001xx Mars light + direction = 4, 5, 6 (bidirectional, forward, reverse) = 000010xx Random Flicker + direction = 8, 9, 10 (ditto, ditto, ditto) = 000011xx Flashing headlight + direction = 12, 13, 14 = 000100xx Single puls strobe + direction = 16, 17, 18 = 000101xx Double puls strobe + direction = 20, 21, 22 = 000110xx Rotary beacon simul + direction = 24, 25, 26 = 000111xx Gyralite + direction = 28, 29, 30 = 001000xx Ditch light type 1, right + direction = 32, 33, 34 = 001001xx Ditch light type 1, left + direction = 36, 37, 38 = 001010xx Ditch light type 2, right + direction = 40, 41, 42 = 001011xx Ditch light type 2, left. + direction = 44, 45, 46 = 001100xx Uncoupler as defined in CV #115, = 48, 49, 50 automatic disengagement in CV #116 = 001101xx “Soft start” = slow power-up of function output = 52, 53, 54 = 001110xx Automatic stoplights for street cars, = 56, 57, 58 stoplight-off delay, see CV #63. = 001111xx Function output turns itself off at speed >0 = 60, 61, 62 (i.e. turns off cab light when driving). = 010000xx Function output turns itself off after 5 minutes = 64, 65, 66 (i.e. to protect smoke generators form overheating). = 010001xx as above, but automatic shut-off occurs after 10 min. = 68, 69, 70 = 010010xx Speed or last dependent smoke generation. = 72, 73, 75 for steam engines as per CV’s #137 - 139 (I.e. preheating during standstill, heavy smoke at high speed or under heavy load.) Smoke turns off as per CV #353; function key has to be pressed to reactivate smoke. = 010100xx Driving state-dependent smoke generation for diesel engines = 80, 81, 82 as per CV#137-139 (preheating during standstill, heavy smoke during motor start-up sound and during acceleration Synchronized control of fan connected to the fan output. Smoke turns off as per CV #353; function key has to be pressed to reactivate smoke.
lighting effects or motorized equipment (i.e. fan, snow blower). (SW version
Dimming time is set with CV’s #190 and 191. 33.10 and up)
direction dependent function outputs.
EXAMPLE:
type. The “ditch lights” only function, if the Bits in CV # 33 and # 34 are configured (the definition in CV # 125 - 128 is not sufficient, but additionally re- quired). Example: If ditch lights are defined for FA1 and FA2 , the Bits 2, 3 in CVs # 33, 34 must be on (e.g. CV # 33 = 00001101, CV # 34 =
00001110).
Special tip for ditch lights: Those are only active if the headlights (F0) are turned on as well as function F2; this is equivalent to the American proto-
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 37
#190
Fade-in time for
88, 89, 90 effect
with SW version 33.10
or higher
(Correction in regards to value 0
with version 34)
0 - 255
0
= 0: illegal value for SW version 33; later 0 sec. = 1: 1 sec fade-in time = (i.e.) 5: @ 4 sec = 255: @ 320 sec
ATTENTION: Above values are valid for a “cycle time” 5 (i.e. CV #63 = 50 … 59). About 1/6 of the
time with cycle time 0; double time with cycle time 9.
#191
Fade-out time for
88, 89, 90 effect
with SW version 33.10
or higher
(Correction in regards to value 0
with version 34)
0 - 255
0
= 0: illegal value for SW version 33; later 0 sec. = 1: 1 sec fade-out time = (i.e.) 5: @ 4 sec = 255: @ 320 sec
ATTENTION: Above values are valid for a “cycle time” 5 (i.e. CV #63 = 50 … 59). About 1/6 of the
time with cycle time 0; double time with cycle time 9.
#353
Automatic
smoke generator
shut-down
0 - 255
=
0 - 106 min
0
For special effect codes “010010xx” or “010100xx”
(smoke generator): Overheat protection: turns OFF after ½ min to about 2 hours.
= 0: Won’t turn off automatically. = 1 … 255: Switches off autom. after 25 sec./unit.
CV
Designation
Range
Default
Description
#137 #138 #139
Characteristics for smoke generators
connected to FO’s 1-6
PWM at stand still
PWM at cruising
PWM during acceleration
0 - 255 0 - 255 0 - 255
0 0 0
The values in CV #137 – 139 define a smoke char­acteristic for the function outputs (FO1, FO2, FO3, FO4, FO5 or FO6; referred to below as FOx), pro­vided a “smoke function” for a diesel or steam en­gine (value 72 or 80) has been selected in the asso­ciated CV #127 – 132:
CV #137: PWM of FOx at standstill CV #138: PWM of FOx at cruising speed CV #139: PWM of FOx at acceleration (PWM = Pulse With Modulation)
CV
Designation
Range
Default
Description
#137 #138 #139
Definition of smoke
generator characteristic,
connected to FO1 – 6.
PWM at stand still PWM at steady speed PWM during accelera-
tion
0 - 255 0 - 255 0 - 255
0 0 0
Provided a “smoke function” for a diesel or steam en­gine (value 72 or 80) has been selected in the associ­ated CV #127 – 132:
With the three values in CV #137 – 139 a smoke char-
acteristic for the function outputs (FO1…FO8; referred
to below as FOx) is defined and at the same time also – IMPORTANT – the maximum permissible voltage!
CV #137: PWM of FOx at standstill CV #138: PWM of FOx at cruising speed CV #139: PWM of FOx at acceleration (PWM = Pulse With Modulation)
#351
Exhaust fan speed at
cruising speed
For DIESEL engines
1 - 255
128
The fan speed is adjusted by PWM; the value in CV #351 defines the effect at steady speed.
= 128: Fan is driven at half the voltage at cruising speed.
#352
Exhaust fan speed at
motor starts and during
acceleration
For DIESEL engines
1 - 255
255
The exhaust fan is set to a higher speed (usually top speed) for generating the typical exhaust puff during motor starts as well during hard accelertions.
= 255: Fan receives maximum voltage at start-up or accelerations.
#353
Automatic smoke
generator shutdown
For STEAM and
DIESEL engines
0 – 255
=
0 - 106
min.
0
If a smoke generator is controlled by one of the effects
“010010xx“ or „010100xx“ in CV’s #127 to 132 (for one
of the function outputs FO1 to FO6), the output turns itself off automatically after the time defined in this CV, in order to protect the generator against overheat­ing.
= 0: no automated turn-off = 1 to 255: automatic turn-off after 25sec/unit, which
offers a maximum time of about 6300sec = 105min.
#355
Exhaust fan speed at
stand-still
1 – 255
0
Supplement to the settings in CV #133 and the effects with code “72” (steam engines) or “80” (diesel en-
CV #137 = 70 .. 90: little smoke at standstill. CV #138 = 200: The smoke intensity is increased to about 80% of its maximum capacity begin­ ning with speed step 1 (at very low speed), which produces relative heavy smoke. CV #139 = 255: The smoke generator is driven to its maximum under heavy acceleration, which results in thick smoke.
Synchronized steam chuffs or typical diesel smoke (with exhaust fan):
With the built-in fan, synchronized steam chuffs or driving-state dependent diesel smoke can be generated without adding additional electronic components.
The heating element of the smoke generator is connected – as in the example above with the
“Seuthe” generator on FO1…FO8 and configured with the appropriate CV for the desired ef- fect (i.e. “72” for steam or “80” for diesel).
The fan is connected to the “fan output” of the large-scale decoder; see chapter “Installation and wiring”, section “Special Connection for Smoke Fan”).
5.23 Configuration of smoke generators
Smoke generators without fan (Example: „Seuthe“ 18 V):
In addition to a simple ON/OFF function via a function output of your choice, the smoke intensi­ty can also be programmed to change between standstill, cruising and acceleration.
This requires the smoke generator to be connected to one of the function outputs FO1… FO8
(FO7 and F8 only with SW version 34 or higher) and the selected output must be programmed for
the desired effect with the associated “effect CV” (with CV #127 for FO1, CV #128 for FO2 etc.); in this case for load dependent smoke of steam engines (effect code “72”) or load de-
pendent smoke of diesels (effect code “80”). The smoke generator characteristic is defined by CV #137, 138 and 139 and must be pro­grammed with appropriate values otherwise the smoke generator will not produce any smoke.
EXAMPLE: - Typical characteristic for a track voltage set around 20V with above smoke generator:
Page 38 Large-scale Decoder & Sound Decoder MX695/6/7/9
For STEAM and
DIESEL engines
gines), where the fan is only set-up for chuff beats or during start-ups and cruising speeds.
With CV # 355, however, the fan speed is adjusted at a standstill, so that even in this state smoke is dis­charged (to a lesser extent).
CV
Designation
Range
Default
Description
#115
Uncoupler control
“Pull-in” time
and
“hold” voltage
or use
CV # 115
for an alternative second
dim value
(dimming 0-90% using
ones digit; tens digit must
be 0)
0 - 99
0
The uncoupler function is only active if “uncoupler” is selected (value 48) in one of the CV’s #125…132:
Tens digit (0 – 9): Time in seconds the coupler re­ceives full voltage (pull-in time):
Value: 0 1 2 3 4 5 6 7 8 9
seconds: 0 0,1 0,2 0,4 0,8 1 2 3 4 5
Ones digit (0 to 9): hold-in power in percent of track voltage, 0 - 90%. Applied after the pull-in time elapsed (necessary for ROCO coupler, not needed for KROIS coupler).
#116
Automatic disengage-
ment during uncoupling
0 - 99,
0 - 199
0
Tens digit (0 – 9): Length of time the loco should move away (disengage) from the train; coding as in CV #115.
Ones digit (0 – 9) x 4 = Internal speed step applied for disengagement (Momentum per CV #3 etc.)
Hundredths digit = 0: No unloading. = 1: Coupler unloading: engine moves toward train in order to relieve coupler ten­sion, before uncoupling and disengaging from the
5.24 Configuration of Electric Uncouplers
“System KROIS” and “System ROCO”
When one or two of the function outputs FO1…FO6 (but not FO7 or FO8) are assigned to the
Example - The following CV’s must (should) be programmed as follows: “Old” design of the “ZIMO TR92-101” (recognizable by the brass mounting brackets):
CV #137, #138, #139 = 60, 90, 120 respectively: (IMPORTANT) The heating element of the USA Trains
smoke generator is designed for maximum 9V, which requires that the voltage of that function output is limited. This is done with suitable values in CV #137, 138 and 139. The above values can be ad­justed to some extent according to need and track voltage.
CV #353 = …i.e. 10: shuts the smoke generator off automatically to prevent overheating (In this example
10”: after 250 seconds).
CV #351, 352 = ...only for diesel engines when effect code “80” is selected in the applicable CV for
FO1…FO6. This defines the fan speed (PWM-voltage) for start-up (default: maximum smoke) and cruising (default: medium smoke); see CV table.
CV #355 = ... for steam and diesel engines. Defines the fan speed (PWM-voltage) at standstill (usually for
very little smoke output).
“ZIMO TR92-101” design after September 2015 (without brass mounting brackets):
If the heating element is connected to 24V (Common positive) and function output (FO1…FO8): CV #137, #138, #139 = 50, 75, 110 respectively: (IMPORTANT) The heating element of the smoke generator
(with the ZIMO added 15 Ohm resistor) is suitable for about 10V maximum, so the voltage has to be
limited in all cases through PWM (Pulse With Modulation) with a CV #139 value of “110” and for the other CV’s correspondingly lower values (about 40% and 60%, which can of course be varied indi-
vidually).
If the heating element is connected to 18V (Common positive with track voltage of 18V or adjustable low-
voltage output set to 18 – 19V) and function output (FO1…FO8 as ground):
CV #137, #138, #139 = 65, 100, 150 respectively: (IMPORTANT) The values are set a little higher than in the
example above (about 25% higher, since the available 18V is 25% lower than 25V).
All other CV’s are the same as in the example for the “old” design; listed here again for the sake of complete-
ness:
CV #353 = …i.e. 10: shuts the smoke generator off automatically to prevent overheating (In this example
“10”: after 250 seconds).
CV #351, 352 = ...only for diesel engines when effect code “80” is selected in the applicable CV for
FO1…FO6. This defines the fan speed (PWM-voltage) for start-up (default: maximum smoke) and
cruising (default: medium smoke); see CV table.
CV #355 = ... for steam and diesel engines. Defines the fan speed (PWM-voltage) at standstill (usually for
very little smoke output).
uncoupler function (CV #127 for FO1 etc.), the control of the couplers as well as the entire un­coupling process is defined by the settings in
CV #115 and CV #116.
These CV’s limit the pull-in time (to prevent overheating), define a hold-in voltage if required (i.e. System “Roco”) as well as the automated coupler unloading and train disengagement.
It is recommended to use the following settings for the Krois system: CV #115 = 60, 70 or 80; these settings will limit the pull-in time (full track power) to 2, 3 or 4 seconds respectively. A hold-in voltage is not required for the Krois coupler and the ones digit can therefore remain at 0.
Notes to automated uncoupling (a.k.a. “Coupler waltz)
- The automatic train disengagement is active if the tens digit in CV #116 is other than 0; if desired with prior coupler unloading (when CV #116 > 100).
- The automatic train disengagement (or the preceding coupler unloading) is started at the same time the coupler is activated, but only if the train is standing still (speed 0); if the train is still moving, the uncoupling, unloading and disengagement procedure won’t start until the train comes to a full stop.
- The procedure terminates when the “temporary” function key is released (or pressed again if in latched mode), or when the predetermined times (CV #115 for the coupler, CV #116 for the disengagement) have expired.
- The uncoupling and disengagement process is aborted immediately if the speed regulator is operated at the same time.
- The driving direction for the train disengagement is always according to the cab setting; directional settings
in the “special effects” definition for uncoupling (Bits 0 and 1 of CV #127, CV #128 etc.) will not be applied.
Wires: blue (Fan positive, 5 – 6 V, to fan output)
yellow: (Fan ground) red: (Heating element positive) green: (to FO1…FO8)
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 39
train. Example: CV #116 = 61: Loco uncouples and drives away
from train for 2 seconds at speed step 4. CV #116 = 155: Loco pushes against train first to un­load couplers, uncouples and then drives away from the train for 1 second at speed step 20.
The “Massoth – Coupler“ (since Fall 2012)
This coupler comes with a 3 stranded color coded connecting wire: Red: Connect to a “common positive” pin with full track power Brown: Connect to any function output Black: Connect to a “GROUND” pin The hook of the Massoth coupler is moved by a motor and does not require a time limit as
does the Krois coupler for example, and therefore does not need to be programmed with an “uncoupler” function effect nor does it need to be protected with a maximum ON-time through CV #115.
There are however two reasons to use the “uncoupler” function effect anyway (value “48”, see description about “System Krois” above):
- To protect the coupler hook from possible damage if inadvertently left in the low position while driving
- If the “coupler waltz” is to be used: in this case, in addition to the effect (“48”) assignment for the function output concerned, CV #115 also needs to be set (because the default
value "0" would mean a time limit of 0 sec (i.e., set it to "50" for a 5-second time limit or = "99" for 9 seconds with 90% hold voltage; (90% (“9”) when the time limit is to be avoided altogether) as well as CV #116 for the desired requirements (see above).
Page 40 Large-scale Decoder & Sound Decoder MX695/6/7/9
CV
Designation
Range
Default
Description
#161
Servo outputs:
Protocol
and alternative
use of
servo outputs 3 & 4
as SUSI
0 - 3
0
Note:
CV #161
must be
set to “2”
for
Smart Servo RC-1!
0
Bit 0 = 0: Servo protocol with positive pulses. = 1: Servo protocol with negative pulses.
Bit 1 = 0: Control wire only active during movement = 1: … always active (consumes power, vibrates at times but holds position even under mechanical load) – this setting is also required for SmartServo RC-1 (with memory wire)! Bit 2 = 0: For two-key operation, with center position (as per CV #181/182) when both function keys are OFF = 1: For two-key operation (as per CV #181/182), where the servo runs only as long as function keys are active.
Bit 3 = 1: Servo outputs 3 and 4 are used for SUSI Data and SUSI clock (only for decoders that actually have 4 servo outputs).
#162
Servo 1 - Left stop
0 - 255
49
= 1 ms
pulse
Defines the servo’s left stop position. “Left” may become
the right stop, depending on values used.
#163
Servo 1 - Right stop
0 - 255
205
Defines the servo’s right stop position.
#164
Servo 1 - Center
position
0 - 255
127
Defines a center position, if three positions are used.
#165
Servo 1 - Rotating
speed
0 - 255
30
= 3 sec
Rotating speed; Time between defined end stops in tenths of a second (total range of 25 sec, default 3 sec.).
#166
- 169 #170
- 173 #174
- 177
As above but for
Servo 2
Servo 3
Servo 4
#166 left stop, #167 right stop, #168 center position, #169 rotating speed.
#170 left stop, #171 right stop, #172 center position, #173 rotating speed.
#174 left stop, #175 right stop, #176 center position, #177 rotating speed.
#181 #182 #183 #184
Servo 1 Servo 2 Servo 3 Servo 4
Function
assignment
0 - 28
90 - 93
101-114
0 0 0 0
= 0: Servo not in operation = 1: Single-key operation with F1
= 2: Single-key operation with F2 and so on to = 28: Single-key operation with F28
= 90: Servo action depends on loco direction: forward = servo left; reverse = servo right
= 91: Servo action depends on loco stop and direction: turns right when stopped and direction is forward, oth­erwise turns left.
= 92: Servo action depends on loco stop and direction: turns right when stopped and direction is reverse, oth­erwise turns left.
= 93: Servo action depends on loco movement: turns right when loco stopped, left when loco moving; direc­tion makes no difference.
= 101: Two-key operation F1 + F2 = 102: Two-key operation F2 + F3 and so on to =127: Two-key operation F27 + F28
= 111: Two-key operation F11 + F12 = 112: Two-key operation F3 + F6 = 113: Two-key operation F4 + F7 = 114: Two-key operation F5 + F8
(Two-key mode as defined with CV #161, Bit 2)
#185
Special assignment
for
live steam engines
0
= 1: Steam engine operated with single servo; speed and direction controlled with speed regulator, stop is in center position. = 2: Servo 1 proportional, on speed regulator, Servo 2 for direction. = 3: as in 2, but: direction-servo is automatically in “neutral” if speed is 0 and F1 = ON; If speed step > 0: direction-servo is engaged.
NOTE to CV #185 = 2 or 3: Servo 1 is adjustable with CV #162, #163 (end stops); with appropriate values the direction can be reversed as well.
Servo 2 is adjustable with CV #166, #167.
5.25 Servo Configuration
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 41
CV
Designation
Range
Default
Description
#28
RailCom Configuration
0 - 3
3
Bit 0 - RailCom Channel 1 (Broadcast) 0 = OFF 1 = ON
Bit 1 - RailCom Channel 2 (Data) 0 = OFF 1 = ON
#29
Grundeinstellungen
Configuration data
0 - 63
14 =
0000 1110
Which is Bit 3 = 1
(“RailCom“
turned on)
Bit 0 - Train direction: 0 = normal, 1 = reversed
Bit 1 - Number of speed steps: 0 = 14, 1 = 28
Bit 2 - DC operation (analog): 0 = off 1 = on
Bit 3 - RailCom (“bidirectional communication“) 0 = deactivated 1 = activated
Bit 4 - Individual speed table: 0 = off, CV # 2, 5, 6, are active. 1 = on, according to CV ‘s # 67 – 94
Bit 5 - Decoder address: 0 = primary address as per CV #1 1 = ext. address as per CV #17+18
#136
Setting the feedback
speed
RailCom
display
factor
128
Correction factor for the speed feedback via RailCom
or (see section 5.8) A value can be read out here after a calibration run
has been performed.
#158
Several special bits +
RailCom variants
0 - 127
4
Bit 0, Bit 1, Bit 6 various special sound settings
Bit 2 = 0: RailCom speed (kph) – feedback using the “old” method (for MX31ZL ! Id 4)
= 1: RailCom speed (kph) – feedback using the new STANDARDIZED method (Id 7).
6 Feedback – Bidirectional communication
All ZIMO decoder types have been equipped with a type of feedback ever since DCC was formed, which has always been a major difference to competitors’ products:
- the ZIMO loco number identification is part of ZIMO DCC decoders since 1997
and as far back as 1990 with ZIMO’s own data format (which is no longer in use today). It can only be used with ZIMO DCC systems (MX1…MX10, MX31ZL, MX32ZL…) and together
with ZIMO track section modules (MX9 and successors): After receiving DCC packets, the decoder sends acknowledgment pulses which will be utilized to identify and locate the de­coder in the respective section of track.
- all ZIMO decoders are ready for the “bidirectional communication” ac­cording to “RailCom” since 2004; it is opertional in newer decoders
such as the MX695, MX696… series from the beginning (basic functions, ongoing expansion with future software updates).
“Bidirectional” means that the information transfer within the DCC protocol is not only flowing towards the decoder but also in the opposite direction; that is, not just driving, function and switch commands are be­ing sent to decoders but also messages such as acknowledgements, actual speed as well as other status information and CV read-outs are being received from decoders.
The functioning principle of RailCom is based on the introduction of short cut-outs (max. 500 micro sec­onds) by the command station to the otherwise continuously sent DCC signal. These cut-outs provide the time and opportunity for the decoders to send a few bytes of data to locally mounted detectors.
The relevant CV’s for RailCom configuration:
With the help of bidirectional communication according to RailCom
decoders will acknowledge received commands -
- which increases operational reliability and the bandwidth of DCC systems because already acknowledged commands don’t need to be sent repeatedly;
current decoder data is sent to the command station (“global detector”) -
- e.g. “real” (measured) train speed, motor load, routing and position codes, “fuel reserves”, current CV values on demand from decoders is sent to the command station or more precisely, to a global detector in the command station;
decoder addresses are recognized by “local” detectors -
- the actual loco positions are determined by local detectors connected to individual track sec-
tions (integrated in future MX9 track section modules), which has been possible with ZIMO’s
own loco number recognition for a long time, even without bidirectional communication. RailCom will be further developed over the coming years and new applications added which of
course requires new software updates in decoders and other equipment. ZIMO decoders as of 2009 are able to send their own loco address from an isolated section of track (with a so called broadcast method, very fast, although only for one loco inside that section), send CV content on demand along with some decoder data such as actual speed in kph, load and decoder temperature.
On the system side, only one third party product has been available from the beginning – the
address display LRC120, which is a “local” RailCom detector displaying the loco address of
one track section. In 2007, the ZIMO MX31ZL came to market as the first command station with an integrated “global” RailCom detector.
In 2014 (4. Quarter), ZIMO will deliver the new MX10 command stations with integrated detec­tors for RailCom. The MX32 cab (released early in 2011) uses feedback functions from the start (speed indicator, CV-reading), but until the appearance of the MX10 it is accessible only in connection with the MX31ZL.
RailCom in ZIMO Decoders is activated with
CV #29, Bit 3 = 1 AND CV #28 = 3
These are usually the default settings on a new decoder, but RailCom is turned off by default
in many sound projects or OEM CV sets and must therefore be activated first with above CV’s
(see table above).
ATTENTION (if the actual speed is not displayed): see CV #158, Bit 2 (in table above).
“RailCom“ is a registered trademark of Lenz Elektronik GmbH.
Page 42 Large-scale Decoder & Sound Decoder MX695/6/7/9
CV
Designation
Range
Default
Description
#265
Loco type selection
1 2
101 102
1 or 101
Steam =
1
Diesel =
101
= 0, 100, 200: Reserved for future applications = 1, 2 … 32: Select among various steam sounds stored
in the decoder, i.e. for loco BR01, BR28, BR50, etc... Chuff sounds as well as other sounds (whistle, compressor, bell…) will be matched.
= 101, 102 … 132: Select among various diesel engines (if several diesel sounds are in the collection).
7 ZIMO SOUND – Selection and Programming
Sound projects, Sound Collections, free and fee-based projects etc.
Specialties of the ZIMO sound organization over the traditional offerings from other manufac­turers.
Each sound decoder requires a sound project in the decoder’s flash memory. The
sound project is basically a file, composed of the sound samples of a real locomotive (or sev­eral locomotives in the case of the "Sound Collection", see below), as well as playback instruc­tions (in the form of schedules, dependencies on operating condition, speed, acceleration, pitch, etc.) and assignments (to function keys, random generators, switch inputs, etc.).
Each ZIMO decoder comes loaded with a sound project (usually a “sound collection”, see
below). Different ZIMO sound projects for installation by the user can be downloaded from the ZIMO sound database at www.zimo.at in the form of “Ready to use” projects (.zpp file) and often, in addition to that, as “Full featured” projects (.zip file):
The “Ready to use” project is a .zpp file and can be uploaded to the decoder by the user with the help of decoder update modules such as the MXDECUP, MXULF, MX31ZL or MX10 command station. The file is placed on an USB stick and the stick plugged into the USB host socket of the mentioned modules or sent from a computer (connected to the USB client socket with the software ZSP or ZIRC installed on the PC) to the decoder. After the sound is uploaded to the decoder, many assignments and settings can be changed to suit individual tastes (even though it is a "ready-to-use" project), using the procedures and CV’s described in the decoder manual.
The “Full featured” project on the other hand is downloaded as a .zip file from the sound database; it cannot be uploaded to the decoder directly but can be unzipped and edited with the help of the “ZIMO sound program” ZSP. Assignments and settings can be determined within ZSP and it is also possible to remove sound samples for external processing or ex­change them with others; it is therefore possible to create your own or highly indiviualized sound projects. The result is again a .zpp file that can be uploaded to the decoder.
ZIMO sound decoders come preferably with a “Sound collection”; this is a special type
of a sound project: sound samples and CV parameters for several engines (i.e. for 5 engines)
are stored in the decoder’s memory. The preferred sound for a given locomotive can be se­lected with the cab (no need to load a different sound sample from the computer).
The user is free to change acoustics of a locomotive to his/her own taste by combining, for ex­ample, a chuff sound from 5 different chuff samples and one or several whistles (selection is made using the “CV #300 procedure); other sounds are selected the same way, such as bells, compressors, steam shovels, oil burners, break squeals etc.
Note: Even normal sound projects ("normal" = for a specific locomotive) comprise the charac­teristics of a "sound collection", by containing several whistles for example from which one can be selected using the “CV #300 procedure”.
Among the sound projects available from the ZIMO sound database it must be distin-
guished between the
- “Free D’load” (= no charge) sound projects, often produced by ZIMO and the
- “Coded” (= purchased) sound projects, from external sound providers.
The "Coded sound projects" are contributed by external ZIMO partners (= providers, for exam­ple by Heinz Däppen for the Rhaetian Railway and American steam locomotives), who get re­imbursed by the sale of "load codes". These fee-based projects can be downloaded for free from the ZIMO Sound Database, but can only be used in "coded" decoders, i.e. those in which the appropriate "load code" has been programmed beforehand. “Encoded decoders"
can be purchased with the “load code” pre-installed (subject to a charge, see price list) or the load code is purchased later and entered to the appropriate decoder CV’s (# 260, 261, 262,
263). The "load code", which authorizes the use of sound projects of a specific sound supplier (i.e. the sound projects of Heinz Däppen) applies to one specific decoder which is identified by its decoder ID (CV 250, 251, 252, 253).
In addition to the "Free D'load" and "Coded" projects, both of which are ready for download
on the ZIMOSound Database (see above), there are also the
- “Preloaded” sound projects; these are available exclusively as pre-programmed decoders
and this in turn often only installed in new locomotives. “Preloaded” sound decoders are not
usually provided by Zimo, but by model railroad manufacturers and distributors, who are also re­sponsible for setting the prices. These sound projects are merely listed in the ZIMO Sound Da­tabase as reference.
Decoders with sound collection – Selecting a loco type using CV #265
i.e.the “European steam/diesel collection”:
Operating the sound decoder for the first time with “Euro steam/diesel” sound collection:
As delivered, the decoder comes with a typical engine sound activated and function-sounds al-
located to function keys:
Function F8 – Sound ON/OFF
sounds played back with a function key remain active regardless whether F8 is on or off (a separate function key
can be assigned with CV #311 to turn the function sound ON/OFF, which could of course also be F8)!
In the case of a decoder with “European steam collection” the sound is of a 2-cylinder en- gine (the chuff rate can only be approximate without further tuning) with automated water drainage and brake squeal as well as some randomly played stationary sound.
The following sounds are allocated to these function keys: F2 – short whistle F7 – coal shoveling or oil burner F4 – water drain (blow off…) F9 – compressor F5 – long whistle (playable) F10 – generator F6 – bell F11 – injector F1 and F3 are not allocated for sound by default since they are usually required for other tasks. The following stationary sounds are allocated to the random sound generator: Z1 – compressor Z2 coal shoveling Z3 injector
The switch inputs are allocated to the following by default: S1 – long whistle S2 – nothing S3 – cam sensor
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 43
SOUND SELECTION .
CHUFF --- SAMPLE --- ((((( play ((((( prev ((((( next
CLEAR ((((( + end ((((( (((((
STORE
((((( ((((( ((((( + end
SOUND SELECTION .
Chuff Beat --- SAMPLE --­ ((((( play ((((( prev ((((( next
CLEAR ((((( + end ((((( (((((
STORE
((((( ((((( ((((( + end
Tasten-Anordnung ZIMO MX31: ((((( 1 F0 ((((( 2 F1 ((((( 3 F2
((((( 4 F3 ((((( 5 F4 ((((( 6 F5
((((( 7 F6 ((((( 8 F7 ((((( 9 F8
ZIMO cab key arrangement: ((((( 1 F0 ((((( 2 F1 ((((( 3 F2
((((( 4 F3 ((((( 5 F4 ((((( 6 F5
((((( 7 F6 ((((( 8 F7 ((((( 9 F8
NOTE: If setting the volume of individual sounds is the main concern, it is more convenient to use the direct CVs, see chapter "Drive-independent basic settings"; in many applications the CV #300 procedure is therefore NOT needed.
A sound project is composed of…
... sound samples, schedules and CV settings.
To produce the sound of a locomotive, the sound sample contains the following components:
1) the "main engine" or “driving sound: this is the central sound, such as the chuff or
diesel engine sound, or the cooling fan (which is the key sound in electric locomotive projects). This "main engine" sound is the only sound component associated with a schedule, which defines important properties, especially the transitions between different sound samples in various speed, acceleration and load situations. This schedule can only be changed in the "ZIMO Sound Programmer" ZSP, not by CV's. However, there are numerous possibilities for fine-tuning the main engine sound through CV’s (eg relation between chuff frequency and speed, lead-chuff ac­centuation, coasting/notching functions, etc.)
2) Other scheduled sounds (often inaccurately called background sounds): these are boiling, draining, turbocharger or brake squealing sounds and many others; also in the case of electric locomotives the actual primary sounds of the thyristor unit and the electric motor. "Scheduled" sounds - both the "main engine" and "other" - are characterized in that the decoder plays them back automatically based on the driving situation, while the "function sounds" (see below) are activated with the cabs function keys. These "other" -sounds (ie all except the "main engine” sound, see above) are NOT played back according to a schedule; they are fully defined by CVs, and can be modified directly by these CV’s or CV # 300 - procedures, even during operation (speed, load dependence, etc.). Only the underlying original recordings, that is the sound sample or a selection of samples, is stored in the sound project (or in the sound collection).
3) The function sounds, which are played back by pressing the corresponding function keys includes acoustic signals such a whistles, horns, bells but also other sounds like coal shoveling, coupler clank, lowering of pantographs as well as station announce­ments. The volume of each sound and whether it is “looped” (for continuous playback as long as the function key is pressed) is defined by CV’s and can be modified by these CV’s or with the CV #300 procedure. Here too, only the sound samples of the project or selections of several projects are predefined.
4) and 5) the switch input and random sounds are normally sounds that can also be
used as function sounds but are triggered by switch inputs or random generators.
The occasionally used term "driving sound" refers to a subset of all the sounds, namely the "main engine" sound and most of the "other" sounds; the "departure whistle" sound for example is not in­cluded because it is not dependent on driving data.
7.1 The “CV #300 procedures”
The term "CV # 300 - procedure" means the "pseudo-programming" of CV # 300, which allows the modification of the currently loaded sound projects during normal operation, in relation to:
- the selection of sound samples within sound groups (i.e. “ short whistle”) of a “sound collection” (which has several sound samples in some of its sound groups) or a “normal” sound project with several sound samples in specific groups.
- the volume and the sound loop behavior for individual sounds; for example, how
loud the whislte blows in relation to the driving sound volume (i.e. chuff beats).
A convenient procedure (w/o the use of CV #300) is available with ZIMO MX31/MX32 cabs
Selecting another chuff set (if several sets are present in a sound collection):
(only possible for steam projects, not for diesel or electrics)
The following procedures are always used in the same way in spite of the flexible decoder lay­out and different sound sample compilations. It is also worth mentioning that the sound sam­ples can be listened to and evaluated under actual operating conditions (with the engine run­ning), not just on the computer.
The selection procedure is started with a “Pseudo-Programming” in operations mode (“on- the-main”):
The “Pseudo-Programming” (meaning that the entered value is not really stored in memory) has the effect that the function keys F0 to F8 no longer actuate function outputs but instead are now available for special tasks within the sound selection procedure. The function keys should be set to momentary, if possible, which would facilitate the procedure. CV #300 proce-
dures must be done in operations mode (on the main), NOT in service mode!
The function key identifications (and the MX31/MX32 cab displays) shown are typical for a ZIMO cab during the selection procedures (and for other sound adjustment procedures) but is analogous to the function keys of third party cabs, although the layout may be different.
The function keys have the following special
meaning during the selection procedure! !
F0 = play : plays back the current chuff sound for evaluation; only possible with
F1, F2 = prev, next : plays back the previous or next recording stored in the decoder; the
sound file can immediately be evaluated with the engine stopped, with the engine running the selected file replaces the currently active.
F3 = CLEAR + end : The selection procedure is stopped and the selection is cleared, that
is no chuff sound will be stored (boiling and blow-off sound remains).
F8 = STORE + end : The selection procedure is stopped with the last selected chuff set
replacing the current set. The selection procedure is also stopped when programming anything else (e.g. CV #300 = 0
or any other value or any other CV) or by interrupting power. In these cases, the current chuff set remains. Such “forced endings” are also useful when the “old” sound should remain as the current sound without first having to locate it again.
The selection procedure is supported with acoustic signals: The “cuckoo jingle” (confirmation jingle) sounds when:
CV #300 = 100 (only for steam / not possible with DIESEL engines!).
the engine at standstill; the chuff sounds are played back automatically when the engine is moving.
the last stored chuff sound is reached; use the key to scroll in the opposite direction
(F1, F2) to listen to the other stored chuff sounds,
play-back is tried (F0) but no sound sample is assigned,
Page 44 Large-scale Decoder & Sound Decoder MX695/6/7/9
ZIMO cab key arrangement
((((( 1 F0 ((((( 2 F1 ((((( 3 F2
((((( 4 F3 ((((( 5 F4 ((((( 6 F5
((((( 7 F6 ((((( 8 F7 ((((( 9 F8
ZIMO cab key arrangement: ((((( 1 F0 ((((( 2 F1 ((((( 3 F2
((((( 4 F3 ((((( 5 F4 ((((( 6 F5
((((( 7 F6 ((((( 8 F7 ((((( 9 F8
FUNCTION SOUND SELECTION.
F6 --- SAMPLE --­ ((((( play ((((( prev ((((( next
CLEAR --- GROUP ---­ ((((( + end ((((( prev ((((( next
----- LOOP ----- STORE
((((( loop ((((( short ((((( + end
SOUND SELECTION .
BOILING --- SAMPLE --­ ((((( play ((((( prev ((((( next
CLEAR --- GROUP ---- ((((( + end ((((( prev ((((( next
STORE
((((( ((((( ((((( + end
SOUND SELECTION .
BREAK SQUEAL -- SAMPLE ­ ((((( play ((((( prev ((((( next
CLEAR --- GROUP ---- ((((( + end ((((( prev ((((( next
STORE
((((( ((((( ((((( + end
SOUND SELECTION .
BLOW OFF --- SAMPLE --­ ((((( play ((((( prev ((((( next
CLEAR --- GROUP ---- ((((( + end ((((( prev ((((( next
STORE ((((( ((((( ((((( + end
a wrong key is pressed (F4, F5 etc.) The “confirmation jingle” is played after ending the selection procedure with F3 or F8. The engines can be operated normally during the selection procedure: with speed regulator,
direction key and MAN key (the latter only with ZIMO cabs); functions cannot be actuated until the selection procedure is terminated with F3, F8 or by other programming steps, see above.
Selecting boiling, whistle, blow-off, brake squeal sounds…
within a sound collection or a sound project containing several samples per group:
The selection procedures for these “automated background sounds” are initiated with a “Pseudo-Programming” in operations mode programming
CV #300 = 128 for the boiling sound (steam only) .
CV #300 = 129 for direction-change sound .
CV #300 = 130 for the brake squeal .
CV #300 = 131 thyristor-control sound (electric engine) .
CV #300 = 132 for the “start” whistle or horn .
CV #300 = 133 for blow-off sound =cylinder valves (STEAM only) .
NOTE: the blow-off selection (CV #300 = 133) is also valid for function key playback (CV #312).
CV #300 = 134 for the driving sound of ELECTRIC engines .
CV #300 = 136 for the switchgear sound of ELECTRIC engines .
The selection procedure for background sounds is the same as for the selection of chuff sounds. EXCEPT: the engine should be at a standstill because the speed regulator is used for setting the volume of the relevant sound file! Note: these sound files can also be used as function sounds, allocated to function keys (see next page); the automated back-ground sounds can then be cancelled with the function keys.
The function keys have the following special meaning during the selection procedure; speed regulator is used for volume setting!
Function keys are used as with chuff selections: F0 = play: plays back the currently selected sound F1, F2 = prev., next: plays back the previous or next recording. F4, F5 = prev., next: switches between sound groups.
The speed regulator acts as volume control for the background sound during the selection procedure.
F3 = CLEAR + end: Selection procedure is stopped
and the current sample removed.
F8 = STORE + end : Selection procedure is stopped
and the new selection activated.
CV #300 = 135 for rolling noise .
The selection procedure can also be ended by any other programming procedure or by removing power.
Normal function outputs cannot be activated as long as the selection procedure is active.
Allocating sound samples to function keys F1 … F19:
within a sound collection or a sound project containing several samples per group:
A sound sample can be allocated to each function key F1…F19 from the sound samples stored in the decoder. It is absolutely permissible to have a function key assigned for a func­tion output (FO1, FO2 etc.) as well as for a sound function, both of which will be activated when the key is pressed.
The allocation procedure for function sounds are initiated with a “Pseudo-Programming” in operations mode programming:
CV # 300 = 1 for function F1 CV # 300 = 2 for function F2 etc. until F19 CV # 300 = 20 for function F0 (!) .
Note: Function F4 is by default used for water drainage sound (with CV #312); if F4 is to be used for something different, CV #312 must be set to zero (CV #312 = 0).
The allocation procedure is very similar to the selection procedures for driving and back­ground sounds, with the difference that sound allocation is not limited to sound samples of a certain group but also allows switching between groups to find the desired sample.
Sound samples are organized in groups for easier location; i.e. groups like “short whistle” /
“long whistle” / “horn” / “bell” / “shoveling coal / “announcements” and much more.
The engine should remain stationary though since the speed regulator is used for volume settings during the allocation procedure!
Depends on entry: F1 . . . F19 The function keys have the following
special meaning during the selection procedure!
F0 = play : plays back the current chuff sound for evaluation. F1, F2 = prev, next : plays back the previous or next recording stored in the decoder.
F4, F5 = prev, next : switches between sound groups (e.g. whistles, bells etc.); starts play
back the with the first sample of this group. The speed regulator acts as volume control for the selected sound during allocation procedure.
F6 = loop : If F6 is “on” when exiting the allocation procedures, the sound sample is stored
and played back as long as the relevant function key is pressed by
Playable whistle! repeating the sound between the loop markers (the loop marks are part of
the sound file).
F7 = short : If F7 is “on” when exiting the allocation procedures, the sound sample is
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 45
ZIMO cab key arrangement: ((((( 1 F0 ((((( 2 F1 ((((( 3 F2
((((( 4 F3 ((((( 5 F4 ((((( 6 F5
((((( 7 F6 ((((( 8 F7 ((((( 9 F8
ZIMO MX31/MX32 key arrangement: ((((( 1 F0 ((((( 2 F1 ((((( 3 F2
((((( 4 F3 ((((( 5 F4 ((((( 6 F5
((((( 7 F6 ((((( 8 F7 ((((( 9 F8
RANDOM SOUND SELECTION .
Z2 --- SAMPLE --­ ((((( play ((((( prev ((((( next
CLEAR --- GROUP ---­ ((((( + end ((((( prev ((((( next
----- LOOP ----- STORE
((((( still ((((( cruise (((( + end
SWITCH INPUT SELECTION .
S1 --- SAMPLE --­ ((((( play ((((( prev ((((( next
CLEAR --- GROUP ---­ ((((( + end ((((( prev ((((( next
----- LOOP ----- STORE
((((( ((((( (((( + end
shortened and played back only as long as the function key is pressed, by omitting the center portion.
Note: F6 and F7 are only effective provided the loop markers are included in the sample; basic settings are also saved; changes take effect only if F6/F7 is actuated.
Note: If F6 and F7 are not actuated, the sound sample will always be played back in the same length it was saved, regardless how long the function key is pressed.
F3 = CLEAR + end : The allocation procedure is stopped and the current sound removed.
There will be no sound allocated to this function key.
F8 = STORE + end : The allocation procedure is stopped and the last selected function sound is stored and ready for playback when this function key is pressed.
The allocation procedure can also be ended by any other programming procedure (e.g. CV
#300 = 0 or any other value or CV) or by removing power from the decoder. The “old” alloca- tions remain active in such cases; such “forced endings” are also useful when the “old” sound
should remain as the current sound without first having to locate it again. The selection procedure is supported with sound signals: The “cuckoo jingle” sounds when:
the last stored sound sample of that group is reached; use the key to scroll in the
opposite direction (F1, F2) to listen to the other stored sounds,
the last stored sound group is reached (with F4 or F5); use the other key (F4 or
F5) to scroll in the opposite direction.
play-back is attempted (with F0) but no sound sample is available,  a wrong key is pressed.
The “confirmations jingle” is played after ending the allocation procedure with F3 or F8.
Allocation of sound samples to the random generators Z1…Z8:
The MX690 decoders provide 8 simultaneously playing random generators who’s timing is de- termined by CV’s; see “CV table” from CV #315.
A sound sample can be added to each random generator from the pool of samples in the de­coder.
The allocation procedure for random sound is initiated with a “Pseudo-Programming” in op- erations mode (on-the-main):
CV # 300 = 102 for random generator Z2 CV # 300 = 103 for random generator Z3 etc.
. Depends on entry: Z1 . . . Z8
The function keys have the following special meaning
during the selection procedure!
The meaning and action of the function keys is the same as for function sounds (see above): F0 = play: playback
F1, F2 = prev, next: playback of previous or next sound sample
etc.
but
F6 = still: If F6 is active when ending the allocation procedure, the sound sample is played as random sound at standstill only (default).
F7 = cruise: If F7 is active when ending the allocation procedure, the sound sample is played as random sound when the locomotive is moving.
The allocation procedure for random sound is the same as for function sound!
Allocation sound samples to switch inputs S1, S2, S3:
The MX690 has 3 switch inputs available, of which two (“1” & “2”) are freely available to the
user while one (“3”) is usually reserved for a cam sensor input; which can also be used for oth­er inputs if not used for a cam sensor (i.e. the virtual cam sensor is used instead). These in­puts can accept reed switches, optical or hall-effect sensors and similar; see chapter 8: “Conecting speaker, cam sensor”.
A sound sample can be allocated to each switch input, from the pool of stored samples in the decoder; playback times can be set with the help of CV’s #341, 342 and 343, see CV table.
The switch input allocation procedure is initiated with the operations mode Pseudo­Programming
CV #300 = 112 for switch input S2 CV #300 = 113 for switch input S3
and so on… . Depends on entry: Z1 . . . Z8
The function keys have the following special meaning
during the selection
CV # 300 = 101 for random generator Z1 (Z1 has special logic incorporated for the compressor and should therefore always be used for that)
procedure!
The meaning and action of the function keys is the same as for function sounds (see above):
F0 = play : play back F1, F2 = prev, next : play back of previous or next sound sample
and so on.
CV #300 = 111 for switch input S1
Page 46 Large-scale Decoder & Sound Decoder MX695/6/7/9
MENU SOUND Incr.Prog.
CV 266 CV 267 CV 268 ((((( + Total Chuff Part -
volume beat volume (((( - steam
+ 2 - 40 + 3 (((( 0 = 43 = 17 = 255
ZIMO cab key arrangement: ((((( 1 F0 ((((( 2 F1 ((((( 3 F2
((((( 4 F3 ((((( 5 F4 ((((( 6 F5 ((((( 7 F6 ((((( 8 F7 ((((( 9 F8
7.2 “Incremental Programming” of sound CV’s,
an alternative to “normal” programming
Configuration variables (CV’s) for optimizing sound effects can of course be programmed in
the conventional manner by changing CV values using the cab in service mode (on the pro­gramming track) or in operations mode (on the main track), but many can alternatively also be programmed by
“Incremental” programming.
This method is not suitable for CVs where individual bits need to be set independently.
The “incremental programming” is a special process of the “operations mode” programming with the following fundamental principle: the CV’s are not programmed with an absolute value
(as is normally the case) but rather the current value of a CV is being incremented or decre­mented by a fixed value (defined in the decoder for each CV).
The function keys of the cab temporarily serve as instruments for the incremental program­ming, which means they cannot be used for function output actuations during that time. The function keys are temporarily assigned for this task with the “Pseudo-Programming”
CV #301 = 66,
which changes the function keys to INC and DEC keys, first for CV #266 (that is the CV num­ber derived from the value + 200).
Several CV’s are grouped together in one procedure for an easier and better handling. In the case of CV #301 = 66, not only the leading CV #266 (“Lead-CV”) is assigned for incremental
programming but also CV #267 and #268. This is again shown here by means of the ZIMO cab with the special MX31 display, but is val-
id analogous for the function keys of other cabs. The function keys have the following special meaning
during the selection procedure!
Incrementing!
Drawing of an MX31 display, not a photo!
The last line shown in gray (absolute CV values) will not be available until bidirectional communication is being implemented!
Decrementing!
Set to default value!
F0, F3, F6 Incrementing, decrementing and default setting of the lead CV number that was entered during the “Pseudo-Programming” initiation CV #301 = … (or via menu with the MX31).
F1, F4, F7 Incrementing, decrementing and default setting of the second CV number of that group; which CV’s that are part of a group is shown in the CV table or is indicated in the ZIMO MX31 cab display.
F2, F5, F8 Incrementing, decrementing and default setting of the third CV number of that
group (if the group includes 3 CV’s). The incrementing and decrementing of CV values (usually in the 0…255 range) takes place in
steps of 1, 5, 10 or 15; this is predefined by the decoder software and cannot be changed. In­termediate values can be entered by direct CV programming, which in reality is hardly neces­sary.
The cuckoo jingle” sounds when….
…. the upper or lower end of a CV value range is reached! If RailCom is not available (because the system used is not equipped with RailCom), the value
of a particular CV can only be determined by reading it out on the programming track. Alt­hough, most of the time this is not necessary since the reaction to a changed CV value can immediately be heard by the changing sound.
Note: With the MXDECUP update module it is possible to read-out and write complete CV and parameter sets and if necessary edit them on a computer!
7.3 The test-run for determining the motor’s basic load
The following procedure enables the (subsequent) adjustment of driving sound to engine load (i.e. inclines, pulling weight…), such as steam chuffs (volume and sound) with the CV’s #275,
276…
Technical background:
The load dependent sound is based on EMF (Electro Motive Force) measurements inside the decoder, which is primarily used for keeping the motor speed constant during load changes. Before the decoder can produce the correct sound for the respective driving conditions it has to know first what these measurements
are at normal “no-load” cruising speed (smooth rolling of the engine or train on straight level track). This “basic load” of an engine or train is often considerably higher on model trains than on the real railroad, which
is due to gearbox losses, power pick-ups etc. Deviations from this “basic load” will then be interpreted as in­clines or declines, which triggers appropriately modified chuff sounds.
Initiated with “Pseudo-Programming”
CV #302 = 75
an automated test run is performed to record the “basic load” factor in forward direction; ATTENTION: the engine (or train) is driven automatically in forward direction for which un-
occupied track must be available of at least 5 meters (15 feet), with absolutely no inclines or declines and without any (tight) curves.
With CV #302 = 76 an automated recording run can be performed in reverse direction, for locomotives that have
different “basic loads” in this direction (otherwise, the basic load in reverse is considered iden­tical to forward).
The measured results are stored in CV’s #777 and 778 (slow/fast PWM values, forward) and #779 and 780 (PWM values in reverse direction); these CV’s can be read out and used as needed for other vehicles, or used as base for further tests.
Note: A “heavy” train (a train with higher rolling resistance due to power pickups of lighted
coaches for example) may have a different “basic load” than an engine with nothing on the hook. A separate recording run may be required for such situation in order to obtain the best load dependent sound.
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 47
CV
Designation
Range
De-
fault
Description
#265
#266
#395
Select loco type
For sound collections; see first page of this chapter (5.)
Total volume
0-255
=
0-400%
64
=
100%
The value “65” results (mathematically) in the highest possible
distortion-free playback volume; but values of up to 100 can be perfectly suitable. Recommended: #266 = 40…90
Maximum volume the sound can be raised to (does not have to be the same value as in CV #266
#396
#397
Defines function key for volume decrease; lowers volume as long as key is pressed; about 10 steps/sec, down to 0.
ATTENTION: This changes CV #266.
Defines function key for volume increase; raises volume as long as key is pressed; about 10 steps/sec, to the maximum defined in CV #395.
ATTENTION: This changes CV #266; can be used as a substi­tute for a mute key.
#310
ON/OFF key for
engine and random
sound
0 - 28,
255
8
Defines the function key (by default F8) that turns the engine sound (chuffs, boiling, blow-offs, brake squeals...) as well as the random sound (compressor, coal shoveling...) ON or OFF.
= 8: F8 key switches driving sound ON or OFF. Note: this is the default key for ZIMO original sound projects;
OEM prjects (i.e. ROCO) often use other settings. Most often 1 for the F1 key.
= 1…28: ON/OFF key for F1…F28. = 255: engine and random sounds are always ON.
#311
#312
#313
ON/OFF key for
function sound
0 - 28
0
Function key assigned as ON/OFF key of function sounds (i.e. F2 – whistle, F6 – bell etc.).
= 0: does not mean that F0 is assigned for this task but rather that the function sounds are always active.
= (#310), if the same value is entered here as in CV #310, the key defined in #310 turns all sound ON/OFF.
= 1 ... 28: Separate ON/OFF key for function sound.
Blow-off key
See chapter 5.5 “Basic steam engine settings”.
(does not belong in this chapter, despite the correct number sequence)
Mute key,
0 - 28
101 -
128
8
This CV assigns a function key with which the driving sounds can be faded in and out, i.e. when the train disappears behind scenery. F8 is used by default, which is already the sound
CV
Designation
Range
De-
fault
Description
#314
#376
on/off key but now does so softly. = 0: No mute key or mute function.
= 1…28: Selected function key F1…F28 as mute key. = 101…128: Assigned function key with inverted action.
Mute –
fade in/out time
0 – 255
=
0 – 25 sec
0
Time in tenths of a second for sound fading in/out when mute button is pressed. Total range is 25 seconds.
= 0 (to 10): minimum time setting of 1 sec. = 11…255: longer “fade” times
Driving sound vol-
ume
(Multiplier)
0 – 255
=
0 - 100 %
255
=
100 %
To reduce the driving sound volume (E.g . Diesel motor with related sounds such as turbo charger) compared to the func­tion sounds.
CV
Designation
Range
INC­Step
Default
Description
LEAD
- CV
#287
Brake squeal
threshold
0 – 255
10
20
The brake squeal should start when the speed drops below a specific speed step. It will be au­tomatically stopped at speed 0 (based on back­EMF results).
#288
Minimum driving time before brake squeals
0 - 255
=
0 - 25 sec
10
50
The brake squeal is to be suppressed when an engine is driven for a short time only, which is usually a shunting run and often without any cars (in reality it is mostly the cars that are squealing not the engine itself!).
Note: Brake squeal sounds can also be as­signed to a function key (see allocation proce­dure CV #300 = …), with which the brake squeal can be started or stopped manually!
CV
Bezeichnung
Werte-
Bereich
Default
Beschreibung
#374
Coasting-Key
(or Notching)
0 - 28
0
Function key that activates “Coasting“, which forces the mo­tor sound to a specified speed independent of the driving
NOTE: The default values of individual CV’s are NOT decoder-specific, but rather depend on the decoder’s sound project. This means that a HARD RESET with CV #8 = 8 returns the de- coder to the state defined by the sound project. The default values listed below are values often used in sound projects, but not necessarily the correct values in all cases.
7.4 Basic settings independent of powertrain
The CV’s in the following table have the same meaning for all types of power (Steam, diesel, electric):
The following CV’s can be programmed both “normal” (i.e. CV #... = ...) and “incremental”. “Incremental programming” is especially useful when the proper value cannot be calculated in
advance and must be determined by trial, which is often the case with many sound parame­ters.
The “Lead CV” in each case is the first of 3 consequential CV’s that are edited and shown on the same screen of a ZIMO MX31/MX32 cab during the “incremental programming” proce-
dure.
Coasting and Notching functions are required for driving situtations where the engine sound
cannot be derived from speed, acceleration and load only.
Primarily in diesel locomotives (but not necessarily limited to diesels), the motor’s idle sound or a certain specified speed step sound is enforced by keystroke.
This method can be used for “downshifting” (often to neutral) as well as “upshifting” (i.e. ele­vated idle for heating). Future software versions will expand this function to a fully independ­ent sound effect.
Page 48 Large-scale Decoder & Sound Decoder MX695/6/7/9
CV
Bezeichnung
Werte-
Bereich
Default
Beschreibung
situation. Define the (sound) speed in CV #375 (often used for idle sound while coasting).
= 0: does NOT mean F0, but rather that NO key is assigned for coasting. = 1 ... 28: One of the function keys F1 … F28 for “Coasting“
# 375
Coasting-Step
(or Notching)
0 - 10
0
Motor speed (sound) to be activated with coasting key (as per CV #374), independent of driving situation.
= 0: Idle sound (typical coasting situations) = 1 … 10: Sound speed (Diesel engines typically have 5 to 10 notches, which can be activated with the coasting key.
#574
Boiling
0 - 255
0
Boiling volume
#576
Directions change
0 - 255
0
Directions change volume
#578
Brake squeal
0 - 255
0
Brake squeal volume
#580
Thyristor sound
0 - 255
0
Thyristor sound volume (ELECTRIC engine)
#582
Start whistle/horn
0 - 255
0
Start whistle/horn volume
#584
Blow-off
0 - 255
0
Blow-off volume (STEAM engine)
#586
Electric motor
0 - 255
0
Electric motor volume (ELECTRIC engine)
#588
Driving sounds
0 - 255
0
Driving sounds volume
#590
Switch gear
0 - 255
0
Switch gear volume (ELECTRIC engine)
#592
Second Thyristor
0 - 255
0
Second Thyristor volume (ELECTRIC engine)
#594
Panto up
0 – 255
0
Pantograph up volume (ELECTRIC engine)
#596
Panto down
0 – 255
0
Pantograph down volume (ELECTRIC engine)
#598
Panto stop (down)
0 – 255
0
Pantograph stop (down) (ELECTRIC engine)
#600
Turbo
0 - 255
0
Turbocharger volume (DIESEL engine)
#602
Dynamic brakes
0 - 255
0
Dynamic brake volume (ELECTRIC engine)
CV
Designation
Range
De-
fault
Description
#571
Function sound F0
0 - 255
=
100, 1-100 %
0
Sound volume operated with function key F0 = 0: full volume, original sound sample volume (same as 255)
= 1 .. 254: reduced volume 1 - 99,5 % = 255: full volume
#514
Function sound F1
0 - 255
0
Volume for function sound F1
#517
Function sound F2
0 - 255
0
Volume for function sound F2
#520
Function sound F3
0 - 255
0
Volume for function sound F3
#523
Function sound F4
0 - 255
0
Volume for function sound F4
#526
Function sound F5
0 - 255
0
Volume for function sound F5
#529
Function sound F6
0 - 255
0
Volume for function sound F6
#532
Function sound F7
0 - 255
0
Volume for function sound F7
#535
Function sound F8
0 - 255
0
Volume for function sound F8
#538
Function sound F9
0 - 255
0
Volume for function sound F9
#541
Function sound F10
0 - 255
0
Volume for function sound F10
#544
Function sound F11
0 - 255
0
Volume for function sound F11
#547
Function sound F12
0 - 255
0
Volume for function sound F12
#550
Function sound F13
0 - 255
0
Volume for function sound F13
#553
Function sound F14
0 - 255
0
Volume for function sound F14
#556
Function sound F15
0 - 255
0
Volume for function sound F15
#559
Funktions-Sound F16
0 - 255
0
Volume for function sound F16
#562
Function sound F17
0 - 255
0
Volume for function sound F17
#565
Function sound F18
0 - 255
0
Volume for function sound F18
#568
Function sound F19
0 - 255
0
Volume for function sound F19
#739
Switch input sound S1
0 - 255
=
100, 1-100 %
0
Volume setting for the sound activated by switch input S1. = 0: full volume, original sample volume (same as 255)
= 1 .. 254: reduced volume 1 - 99,5 % = 255: full volume
#741
Switch input sound S2
0 - 255
0
Volume setting for the sound activated with switch input S2
#743
Switch input sound S3
0 - 255
0
Volume setting for the sound activated with switch input S3
NOTE: If a decoder comes with a potentiometer for volume control (mostly on large-scale decoders), the pot meter should NOT be fully opened if full volume is not really desired (Loss of sound quality if pot meter is fully open and at the same time the volume is heavily reduced by CV’s!).
The volume for background sounds (boiling, brake squealing etc.), function sounds, random sounds and switch input sounds can be set within the sound selection proccedures (see the “CV #300 procedures” above).
More convenient however is the direct volume adjustment by CV’s (especially when no sound selection is necessary, which is often the case). Of course, not all sounds listed below are part of every sound project. Changing sound CV values of sound files that are not part of the relevant sound project have no effect.
Background sounds - Volume adjustments:
Note: The CV ahead of the CV’s listed (#573, 575 etc.) contain the sound sample numbers to be played.
Function sounds - Volume adjustments:
#674, #677…#698 = volume for sounds on F20, F21…F28.
Note: The in-between CV’s above (#570, 572, #513, 515, 516, 518 etc.) hold information for the relevant sound samples (sample numbers, loop parameters etc.), which can also be modified if needed, usually with the CV #300 procedures.
Switch input sounds - Volume adjustments:
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 49
#745
Random sound Z1
Volume setting for sound activated by random generator Z1
#748
Random sound Z2
Volume setting for sound activated by random generator Z2
#751
Random sound Z3
Volume setting for sound activated by random generator Z3
#754
Random sound Z4
Volume setting for sound activated by random generator Z4
#757
Random sound Z5
Volume setting for sound activated by random generator Z5
#760
Random sound Z6
Volume setting for sound activated by random generator Z6
#763
Random sound Z7
Volume setting for sound activated by random generator Z7
#766
Random sound Z8
Volume setting for sound activated by random generator Z8
CV
Designation
Range
INC-
step
De-
fault
Description
LEAD
- CV
#266
Total volume
0 - 255
5
64
See chapter
5.4 “Basic settings independent of powertrain”
#267
Chuff sound
frequency with
“virtual cam sensor“
also see CV #354 in
this table
(chuff frequency at
speed step 1)
0 - 255
1
70
CV #267 is only active if CV #268 = 0: Chuff beats follow the “virtual cam sensor”; an ac-
tual cam sensor is not needed in this case.
The default setting “70” results in about 4, 6 or 8
chuffs per wheel revolution, depending on the chuff set selected; because it also depends in large part on the motor and gearbox used, an individual ad­justment is necessary in most cases in order to achieve the exact chuff frequency. This is the pur­pose for CV #267:
The lower the value the higher the chuff frequency and vice versa. The setting should be performed at a low speed (around speed step 10), but not at the lowest speed step 1.
CV
Designation
Range
INC-
step
De-
fault
Description
#268
Switching to real
cam sensor
and
trigger count for chuff
rate and
Special function for
“Simple articulated”
steam engines
0 - 255
1
0
= 0: “Virtual“ cam sensor is active (to be adjusted with CV #267, see above). = 1: real cam sensor is active (connected to switch input 2 of the MX640, see chapter 6); each negative spike results in a chuff beat. = 2, 3, 4 … real cam sensor, several triggers in sequence (2, 3, 4 …) result in one chuff beat. = 128 (Bit 7=1 with “virtual” cam sensor): second driver is a bit slower; only meaningful if a second sound sample is available in the sound project. (Bit 7 = 1 with real cam sensor, see above for val­ues): Cam sensor for driver 1 on IN3 (as usual), Cam sensor for driver 2 on IN2 (only possi­ ble if decoder has 2 inputs). = 192 (Bit 6 and 7 = 1): When no separate sound sample is available for the second driver, the same sample is played back for the second driver albeit a bit slower.
LEAD
- CV
#269
Accentuated
lead-chuff
0 - 255
10
0
A typical sound signature of a passing steam en­gine is that one chuff out of a group of 4 or 6 chuffs is louder in volume than the rest; this effect is al­ready part of the chuff set but can be further ampli­fied with the help of CV #269.
#270
PROJECT
not functional yet:
Longer chuff length at very low speeds
0 - 255 10 ?
PROJECT (not yet implemented): The chuff sounds of a real engine are extended
when driving at very low speeds due to the me­chanical valve control. This effect can be more or less accentuated with CV #270.
#271
Overlapping effect at
high speed
0 – 255
(useful
up to @
30)
1
16
The individual steam chuffs of a real engine over­lap each other at high speed. Because the fre-
quency of the chuffs increases but won’t shorten to
the same extend they will eventually blend in to a weakly modulated swoosh. This is not always desired in model railroading be-
cause it doesn’t sound that attractive, hence CV
#271, with which an adjustment is possible to have the chuff beats accentuated at high speed or rather fade away.
LEAD
- CV
#272
Blow-off duration
also see CV #312
(blow-off key)
0 - 255
=
0 - 25 sec
10
50
=
5 sec
Opening the cylinder valves on a prototype steam engine for the purpose of water drainage is entirely up to the engineer. An automated draining at start­up is more suitable in model railroading; CV #272 defines how long after start-up the blow-off sound should play.
Value in CV #272 = time in tenth of a second! Note: If the blow-off sound is also allocated to a
function key (as delivered on F4, see CV #312), the automated blow-off sound can be shortened or extended with the relevant function key. Automated blow-off and function key blow-off are inevitably the
Note: The CV immediately ahead of the CV’s listed (# 740, 742) contain the sound sample numbers to be
played.
Random sounds - Volume adjustments:
Note: The CV immediately ahead of the CV’s listed (#744, 747 etc.) contain the sound sample numbers to be
played.
7.5 Steam engine  Basic sound settings
The following CV’s can be programmed both “normal” (i.e. CV #... = ...) and “incremental”. “Incremental programming” is especially useful when the proper value cannot be calculated in
advance and must be determined by trial, which is often the case with many sound parame­ters.
The “Lead CV” in each case is the first of 3 consequential CV’s that are edited and shown on the same screen of a ZIMO MX31/MX32 cab during the “incremental programming” proce-
dure.
Page 50 Large-scale Decoder & Sound Decoder MX695/6/7/9
CV
Designation
Range
INC-
step
De-
fault
Description
same (as per selection/allocation). = 0: no blow-off sound played back
#273
Start-up delay
during blow-off
0 - 255
=
0 - 25 sec
1
0
Opening the cylinder valves and with it the related blow-off sound on a real steam engine starts most often before the engine even starts to move.
This can be imitated with CV #273 by automatically delaying the start of the locomotive.
This effect is cancelled when a shunting function with momentum deactivation is being activated (see allocation of F3 or F4 in CV #124!)
= 0: no delayed start = 1: Special setting for blow-off via speed
regulator; no start-up delay, but setting the speed to the lowest speed step causes the blow-off sound to be played without powering the motor (only with 128 speed steps).
= 2: Start-up delay in tenths of a second, Recommendation: no value > 20 (> 2 sec)
#274
Blow-off schedule,
start-up whistle
schedule
0 - 255
=
0 - 25 sec
10
30
Constant opening and closing of the cylinder valves in real shunting operations, that often re­quires many short trips with associated idle times, is usually ommited. CV #274 causes the blow-off sound to be suppressed if the engine wasn’t stand­ing still for the time defined here.
Value in CV #274 = time in tenth of a second! The same stop-time is also used for the start-up
whistle!
#312
Blow-off key
0 - 19
-
4
=
F4
Defines a function key to playback the blow-off sound manually, for shunting with open cylinder valves for example (that is the same sound pro­grammed with CV #300 = 133 for automated play­back).
= 4: usual blow-off key = 0: no key assigned (use this setting if keys are
needed for other purposes).
#354
Steam chuff
frequency
at
speed step 1
also see CV #267 in
this table
1 - 255 - 0
CV #354 works only if used together with CV #267!
CV #354 compensates for the non-linear speed measurements of the “virtual cam sensor”:
While the adjustment of CV #267 is done in the vicinity of speed step 10 (slow but not very slow), a correction for speed step 1 can be performed with CV #354 (extremely slow).
= 0: no effect
= 1…127: more chuff beats in relation to CV #267, = 255…128: less chuff beats.
CV
Designation
Range
INC-
step
De-
fault
Description
#154
Various special bits
- 0
Bit 1 = 1: DIESEL, ELECTRO: Start immedi­ately even if idle sound playback is not fin­ished.
Bit 2 = 1: DIESEL, ELECTRO: Wait for idle sound at short stops before departure.
Bit 4 = 1: STEAM: Two stage compressor (Z1 for fast refill after coming to a stop, Z2 for slow pressure loss compensation during longer stops).
Bit 7 = 1: STEAM: Delay departure until start whistle has finished playback.
Other Bits: OEM special applications (Pantos)
#158
Various special bits
- 0
Bit 0 = 1: SPECIAL MX648: Function output FO1 is used for an automatic control line of an external energy storage.
Bit 1 = 1: DIESEL-MECHANICAL: No RPM increase when braking (see CV #364). Bit 2 = 0: RailCom actual speed (kph) feedback in “old” format (for MX31ZL, RailCom ID 4). = 1: RailCom actual speed (kph) feedback in current format (RailCom ID 7). Bit 3 = 1: “Looped” driving sounds will be faded out when switching to a different speed step in order to shorten the sounds.
Bit 4 = 1: Steam chuff frequency increases slower at high speed (non-proprotional)
Bit 5 = 1: Braking (even by one speed step) causes the motor and turbo sounds to decrease by on sound step. Bit 6 = 1: Thyristor sound may be louder when braking (even if the volume is supposed to decrease according to CV #357); see CV #357. Bit 7 = 1: SPECIAL MX645: ELECTRIC: Flashes of light (approx. 0.1 sec) on FO7 when switch gear sound is played.
#394
Sample crossfading
0 - 255 - 0
Bit 0 = 1: SPECIAL MX645: ELECTRIC: Flashes of light (approx. 0.1 sec) on FO6 when switch gear sound is played.
Bit 4 = 1: Faster acceleration when speed regulator fully opened.
Bit 5 = 1: Crossfading of chuff samples
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 51
CV
Designation
Range
INC­Step
Default
Description
LEAD
- CV
#275
Chuff sound volume at low
speed and no-load
0 - 255
10
60
With this CV the chuff volume can be ad-
justed for low speed and “basic load” (same conditions as during the “automat- ed recording run”).
Here, the engine is driven by about 1/10 of its full speed, adhering to the exact speed is however not important.
During this adjustment CV #277 is to be
left at “0” (default), so that the setting for “no-load driving” is not influenced by load
factors.
#276
Volume at high speed and no-load
0 - 255
10
80
Same procedure as in CV #275 above, but for high speed.
CV #276 defines the “basic-load” chuff sound volume at full speed. Set the speed regulator to maximum during this set-up.
#277
Chuff volume changes accord­ing to load
0 - 255
10
0
=
no
reac-
tion
When deviating from the basic load (as
determined by the “Automated recording
of the motor’s “basic load” factor”, see above), the chuff beat volume should be increasing (on inclines) or decreasing on declines (even muted).
CV #277 defines the degree of change, which must be set to the proper value by trial.
LEAD
- CV
#278
Load change threshold
0 - 255
10
0
With this CV, a change in volume to small load changes can be suppressed (i.e. in curves) in order to prevent chaotic sound impressions.
Suitable settings can only be determined by trial.
#279
Reaction time to load change
0 - 255 1 0
This CV determines how quick the sound reacts to load changes, whereas the fac-
tor is not just time but rather “load-change dependent time” (= the bigger the change
the faster the effect). This CV is also used to suppress chaotic sound changes.
Suitable settings can only be determined by trial.
LEAD
- CV
#281
Chuff volume
­Acceleration
threshold for full load sound
0 – 255 (internal
speed steps)
1
1
More powerful and louder chuff sounds should be played back indicating in­creased power requirements during ac-
celerations, compared to “basic load”. As
is the case with the prototype, the in­creased sound should be noticeable be­fore the increase in speed becomes visi­ble, since the latter is a result of the in­creased steam volume supplied to the pis­tons. It is therefore practical that the heavy acceleration sound is played back when the speed has increased by just one speed step (when no real speed change is noticed), to be able to control the proper sound sequence with the speed regulator.
The “engineer” can in this fashion adjust
the sound (by increasing the speed by 1 step) in anticipation of an imminent in­cline.
=1: Acceleration sound played back (at full volume) if speed has increased by just one speed step.
= 2, 3…. Acceleration sound played back at full volume only after increasing speed by this number of speed steps; before that: proportional volume.
#282
Duration of acceleration sound
0 - 255
=
0 - 25
sec
10
30
=
3 sec
The acceleration sound should remain for a certain length of time after the speed in­creased (otherwise each single speed step would be audible, which is unrealis­tic).
NOTE: The default values listed in the individual CV’s are guidelines only, as actual values in
reality may be determined by the loaded sound project; this also means that a HARD RESET
with CV #8 = 8 restores the CV’s back to the sound project values.
7.6 Steam engine  Load and acceleration dependency
The load dependency of the sound is based on the current engine load and the acceleration / deceleration settings. The results of the “basic” load test serve as reference for the current mo­tor load, see section 7.3 "The test run for determining the motor’s basic load”.
NOTE: ZIMO large-scale decoders MX695 and up, and possibly some of the smaller decoders (but not the current MX640 – MX648’s) contain a position and acceleration sensor that will im- prove the function of load dependency dramatically, once it is activated with future software versions.
To set up load dependent sound, follow the instructions in this order:
+ Perform "The test run for determining the motor’s basic load”; see chapter 5.3 + Adjust CV’s #275 and #276 + Adjust CV #277 + If needed CV #278 and #279
NOTE: The CV’s in this chapter affect the volume’s load dependency of the relevant sound
(that is, by how much the volume should increase at higher loads or decrease by lesser loads, all the way down to mute if necessary). A possible exchange of sound samples at load in­crease or decrease is however a matter of the sound project program.
There are however special exceptions to this rule...
Page 52 Large-scale Decoder & Sound Decoder MX695/6/7/9
Value in CV #282 = time in tenth of a sec­ond!
#283
Chuff sound volume during full acceleration
0 - 255
10
255
The volume of steam chuffs at maximum acceleration is set with CV #283 (default: 255 = full volume). If CV #281 = 1 (acceleration threshold set to 1 speed step), the volume defined here is applied with each speed increase, even if it’s just 1 step.
LEAD
- CV
#284
Threshold for deceleration sound
0 -255
(internal
speed steps)
1
1
Steam chuffs should be played back at less volume (or muted) signifying the re­duced power requirement during decel­eration. The sound reduction logic is ana­log to a reversed acceleration (per CV #281 to #283).
= 1: Reduces sound to a minimum (as per CV #286) when speed is reduced by just 1 step.
= 2, 3 ... sound reduced to minimum after lowering speed by this number of steps.
#285
Duration of
reduced volume
during
deceleration
0 - 255
=
0 - 25
sec
10
30
=
3 sec
After the speed has been reduced, the sound should remain quieter for a specific time (analog to the acceleration case).
Value in CV #285 = time in tenth of a sec­ond!
#286
Volume level
during
deceleration
0 - 255
10
20
CV #286 is used to define the chuff vol­ume during deceleration (Default: 20 = pretty quiet but not muted).
If CV #284 = 1 (deceleration threshold set to 1 speed step), the volume defined here is applied with every reduction in speed (even if decreased by just 1 step).
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 53
CV
Designation
Range
INC-step
De-
fault
Description
#266
Total volume
0 - 255
5
64
See chapter
7.4 “Basic settings independent of powertrain”
#280
Diesel engine
-
Load influence
0 - 255
10
0
This CV determines the reaction of the diesel sound to load:
Diesel-hydraulic engines – higher and lower rpm’s and notches Diesel-electric engines – cruise/idle rpm Diesel-mechanical – shift points.
= 0: no influence, motor rpm changes with speed = 1 to 255: minimum to maximum influence. NOTE: It is highly recommended to perform the automated test run with CV #302 = 75 first (see chapter 7.3).
#154
Various Special Bits
- 0
Bit 1 = 1: DIESEL, ELECTRO: Start immediately even if idle sound playback is not finished. Bit 2 = 1: DIESEL, ELECTRO: Wait for idle sound at short stops before departure.
Bit 4 = 1, Bit 7 = 1: see STEAM
#158
Various special bits (mostly in connection
with functions de­fined in various other CV’s)
Bit 0 = 1: SPECIAL MX648: Function output FO1 is used for an automatic control line of an external energy storage.
Bit 1 = 1: DIESEL-MECHANICAL: No RPM increase when braking (see CV #364).
Bit 2 = 0: RailCom actual speed (kph) feedback in “old” format (for MX31ZL, RailCom ID 4). = 1: RailCom actual speed (kph) feedback in current format (RailCom ID 7).
Bit 3 = 1: “Looped” driving sounds will be faded out when switching to a different speed step in order to shorten the sounds.
Bit 4 = 1: Steam chuff frequency increases slower at high speed (non-proportional)
Bit 5 = 1: Braking (even by one speed step) causes the motor and turbo sounds to decrease by on sound step. Bit 6 = 1: Thyristor sound may be louder when braking (even if the volume is supposed
CV
Designation
Range
INC-step
De-
fault
Description
to decrease according to CV #357); see CV #357.
Bit 7 = 1: SPECIAL MX645: ELECTRIC: Flashes of light (approx. 0.1 sec) on FO7 when switch gear sound is played.
#344
Run-on time of motor sounds (Cooling fan etc.) after stops
0 - 255
=
0 - 25 sec
-
0
After the engine comes to a stop some accesso­ries are supposed to remain operating (i.e. cool­ing fans) and automatically stop after the time de­fined here, provided the engine didn’t start up again.
= 0: Won’t run after stop
= 1 … 255: Runs for another 1 to 25 seconds.
#345
SHIFT key
to switch between
two sound
variations within a
sound collection:
for different operating
modes of a
locomotive or
between the sounds
of a
MULTI-SYSTEM
engine
1 - 28 0
Defines a function key (F1 – F28) which switches between two sound types (i.e. between an electro and diesel sound of a multi-system engine) that is, between the sound in CV #265 and the next one in the list. For example
Switch between two modes of operation (light train / heavy train) or
Switch between en electric or diesel propul­sion of a multi-system engine; typical case: Sound project for RhB Gem.
#346
Prerequisite for
switching between
collections,
as per CV #345
0, 1, 2 0
Bit 0 = 1: Switches between sound collections at stand-still even with sound ON. Bit 1 = 1: Switching is also possible while driving.
#347
Key for switch-over
to solo driving and
sound performance
0 - 28 0
= 0: No key, no switch-over possible. = 1…28: One of these function keys (F1 – F28) acts as the switch-over key for driving a heavy train or a single locomotive. Parameters are selected with CV #348.
#348
Switch-over parame-
ters for key selected
with CV #347
0 - 7 0
When driving solo (Function key as per CV #347 is ON), the… Bit 0 = 1:…Diesel sound should rev up unhindered to maximum rpm (or limited in relation to speed step as per CV #389). Bit 1 = 1: acceleration and deceleration times in CV #3 and 4 should be reduced, wherein the amount of reduction is set in CV #390. Bit 2 = 1: motor’s idle sound should be played­ back when driving at low speeds, wherein the highest speed step is set in CV #391.
#387
Influence of accel-
eration to diesel
sound steps
0 - 255 0
In addition to the speed step (as defined in the ZSP flow diagram), the current change of speed (accel­eration, deceleration) should also have an influ­ence on sound due to the associated increase or decrease in load.
7.7 Diesel and Electric engines  Diesel motor sound
Turbocharger sound Thyristor sound Electric motor sound Switchgear sound
Diesel and Electric engines have certain commonalities and are therefore described in the same chapter: Diesel-electric propulsion systems have sound components (sound sequences) from both areas. On the other hand, the separation of "Basic settings" and "Load dependence" (as with the steam engines in the previous chapters) is not practical.
Page 54 Large-scale Decoder & Sound Decoder MX695/6/7/9
CV
Designation
Range
INC-step
De-
fault
Description
= 0: No influence (sound depends on speed step only) = 64: experience has shown this to be a practical value = 255: maximum acceleration response (highest sound step during acceleration)
#388
Influence of deceler-
ation to diesel sound
steps
0 - 255 0
Same as CV #387 but used during decelerations. = 0: No influence (sound depends on speed
step only) = 64: experience has shown this to be a practical value = 255: maximum deceleration response
#389
Limitation of the ac-
celeration influence
over diesel sound
steps
0 - 255 0
This CV determines how far the sound step may deviate during accelerations (= difference between target speed from the cab and actual speed) from a direct depedence on speed step (as per schedule).
= 0: No deviation; motor sounds according to schedule, sound does not depend on acceleration.
= 1…254: Dependence increases with value. = 255: fully dependend on target speed.
#390
Momentum reduction
when driving solo
(engine only)
0 - 255 0
When switching to solo driving (or lighter train) with key defined in CV #347 the momentum is reduced ( if so selected with CV #348, Bit 1):
= 0 or 255: No reduction = 128: Momentum reduced by half = 64: Reduced to ¼ = 1: virtually cancels all momentum.
#391
Driving with idle
sound,
when driving solo
0 - 255 0
The diesel motor sound should remain at idle when driving solo (with function key defined in CV #347), until the speed step defined in CV #391 is reached.
#364
Speed drop during
upshifts
for DIESEL engines
with mechanical
transmission.
0
This special CV applies only to diesel-mechanical engines and defines the typical drop in speed when shifting up.
See sound projects (i.e. VT 61)
#365
Upshift rpm
for DIESEL engines
with mech. transmis-
sion.
0
This special CV applies only to diesel-mechanical engines and defines the highest rpm before shifting up.
See sound projects (i.e. VT 61)
#366
Maximum turbo
sound volume
for DIESEL engines
0 - 255
48
#367
Turbo rpm depend-
ency on speed
0 - 255
150
Turbo playback frequency depending on engine speed.
CV
Designation
Range
INC-step
De-
fault
Description
for DIESEL engines
#368
Turbo rpm depend-
ency on acceleration
for DIESEL engines
0 - 255
100
Playback frequency depends on the difference of set speed to actual speed (= acceleration).
#369
Minimum load for
turbo
for DIESEL engines
0 - 255
30
Audibility threshold for turbochargers; the load is derived from CV #367 and 368.
#370
Frequency increase
of turbo
for DIESEL engines
0 - 255
25
Speed of frequency increase of the turbocharger.
#371
Frequency decrease
of turbo
for DIESEL engines
0 - 255
15
Speed of frequency decrease of the turbocharger.
#289
Thyristor control
Stepping effect
ELECTRIC engines
0 - 255
The pitch of the thyristor sound of many engines (typical example: Taurus) should not ascend even­ly but rather in steps (scale).
= 1 - 255: ascending scale according to the corre­sponding speed step interval.
#290
Thyristor sound
at “slow” speeds
for
ELECTRIC engines
0 - 255
Sound pitch for speed defined in CV #292.
#291
Thyristor control
Sound pitch at max-
imum speed
for
ELECTRIC engines
0 - 255
Sound pitch at top speed. #292
Thyristor
low speed
for
ELECTRIC engines
0 - 255
Speed for sound pitch per CV #290.
#293
Thyristor control
Volume at steady
speed
for
ELECTRIC engines
0 - 255
Thyristor sound volume at steady speed (no accel­eration or deceleration in process).
#294
Thyristor control
Volume during
acceleration
for
ELECTRIC engines
0 - 255
Volume during accelerations; the value in CV #294 should be larger than in CV #293 to be useful (so that the volume increases when the engine accel­erates).
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 55
CV
Designation
Range
INC-step
De-
fault
Description
#295
Thyristor control Volume during
deceleration Motor sound of
ELECTRIC engines
0 - 255
Volume during heavier decelerations (braking)
#357
Thyristor control
Lowering the volume
at higher speeds
for ELECTRIC
engines
0 - 255
0
Internal speed step at which the thyristor sound volume should be reduced. The volume stays at this reduced level while braking.
By changing CV #158 Bit 6 = 1, the volume will be raised while braking.
#358
Thyristor control
Volume reduction
curve at higher
speeds
for ELECTRIC
engines
0 - 255
0
Defines a curve as to how the thyristor sound should be lowered at the speed step in CV #357.
= 0: no reduction. = 10: reduced by about 3% per speed step. = 255: aborts the sound when the speed step defined in CV #357 is reached.
#362
Thyristor control
Switchover threshold
for second thyristor
sound
for ELECTRIC
engines
0 - 255 0
Defines a speed step at which a second thyristor sound for higher speeds is played back; this was
introduced for the sound project “ICN” (Roco OEM
sound) = 0: no second thyristor sound.
#296
Electric motor sound,
maximum volume
for
ELECTRIC engines
0 -255 0
Maximum volume of motor sound.
#297
Electric motor sound,
when sound
becomes audible
for
ELECTRIC engines
0 -255 0
Internal speed step at which the motor sound be­comes audible.
Part of a charachteristic curve with CV’s #298/299.
#298
Electric motor sound,
volume dependent
on speed
for
ELECTRIC engines
0 -255 0
Slope of the characteristic curve for speed de­pendent volume. (curve starts with #297)
See ZSP manual!
#299
Electric motor sound, Sound pitch
dependent on speed
for
ELECTRIC engines
0 -255 0
Slope of the characteristic curve for speed de­pendent volume. (curve starts with #297)
See ZSP manual!
#372
Electric motor sound,
Volume dependent
0 – 255
0
= 0: No function = 1…255: minimal to maximum effect
CV
Designation
Range
INC-step
De-
fault
Description
on speed
for
ELECTRIC engines
#373
Electric motor sound,
Volume dependent
on braking
for
ELECTRIC engines
0 – 255
0
= 0: No function = 1…255: minimal to maximum effect
#350
Switchgear sound, lock-out after start up
for ELECTRIC
engines.
0 - 255 0
Time in tenths of a second (0 – 25 sec.) the switch gear sound should be delayed after departure; use­ful when the first switching step is already part of the sound sample “idle -> F1”.
The switchgear on some engines (i.e. E10) should not be heard immediately after start-up but rather after some time defined here.
= 0: Switchgear is heard immediately at departure.
#359
Electric switch gear
sound
Playback duration for
the switch gear
sound during speed
changes
for ELECTRIC
engines
0 - 255
30
Time in tenth of a second the switch gear should be heard during speed changes (adjustable from 0 – 25 sec.).
Effective only if switch gear sound is part of the sound project.
#360
Electric switch gear
sound
Playback duration for
the switch gear
sound after coming
to a stop
for ELECTRIC
engines
0 - 255 0
Time in tenth of a second the switch gear should be heard after the engine comes to a full stop (ad­justable from 0 – 25 sec.).
= 0: no sound after stop.
#361
Switch gear sound
Playback delay
for ELECTRIC
engines
0 – 255
20
During rapid successions in speed changes the switch gear sound would be played back too often. CV #361: Time in tenths of a second (0 – 25 sec.) defines minimum delay between multiple play­backs.
#363
Switch gear sound Dividing the speed
into shift steps for ELECTRIC
engines
0 - 255 0
Number of shift steps to cover the whole speed range; i.e. if 10 shift steps are programmed, the switch gear sound is played back at internal speed step 25, 50, 75… (a total of 10 times) = 0: synonymous with 5 (5 switch steps over the whole speed range).
#380
Manual electric brake
key
1 – 28 0
Defines a function key to manually control the sound of a “dynamic” or “electric” brake.
#381
Electric brake -
0 – 255
0 The electric brake shall only be heard between the
Page 56 Large-scale Decoder & Sound Decoder MX695/6/7/9
CV
Designation
Range
INC-step
De-
fault
Description
minimum speed
value defind in CV #381…
#382
Electric brake -
maximum speed
0 – 255
0
…and the value in CV #382
#383
Electric brake -
Pitch
0 – 255
0
= 0: Pitch independent of speed = 1…255: …depends increasingly on speed.
#384
Electric brake –
Deceleration
threshold
0 – 255
0
The number of speed steps lowered during decel­eration before the electric brake sound is played back.
#385
Electric brake –
Downhill
0 – 255
0
= 0: no effect at “negative” load = 1 – 255: Sound triggered at “negative” load.
#386
Electric brake –
Loops
0 – 255
0
Bit 3 = 0: Sound fades out at sample end = 1: Sound ends at with sample end
Bit 2…0: Increases minimum playback time by 0 …
7 seconds, to prevent an interruption in break sound between speed steps.
CV
Designation
Range
Default
Description
#374
Coasting-Key
(or Notching)
0 - 28
0
Function key that activates “Coasting“, which forces the mo­tor sound to a specified speed independent of the driving situation. Define the (sound) speed in CV #375 (often used for idle sound while coasting).
= 0: does NOT mean F0, but rather that NO key is assigned for coasting. = 1 ... 28: One of the function keys F1 … F28 for “Coasting“
# 375
Coasting-Step
(or Notching)
0 - 10
0
Motor speed (sound) to be activated with coasting key (as per CV #374), independent of driving situation.
= 0: Idle sound (typical coasting situations)
= 1 … 10: Sound speed (Diesel engines typically have 5 to
10 notches, which can be activated with the coasting key.
#398
Automatic Coasting
0 – 255
0
The number of speed steps the train’s speed has to be re­duced within 0.5 seconds in order for the automatic coasting effect to set the motor sound to idle (without assigning a coasting key above). The motor sound will not return to idle if the speed is reduced at a slower rate.
CV
Designation
Range
Default
Description
#339
Key assignment for
raising diesel step
0 - 28
0
Define a function key that raises the diesel motor to the min­imum step defined in CV #340.
See below if more function keys are needed to raise the sound further.
#340
Define diesel step
and possibly more
key assignments
0 - 10
0
Minimum step the sound of the diesel motor should increase to with the key defined in CV #339. These steps are not mo­tor speed steps but rather sound steps. A sound library can
have 1 to 10 speed (sound) steps (i.e. “1” forces the sound to sound step 1, “2” to sound step 2 etc.). The sound can
only be increased with these keys. For sound decrease, use the coasting functions in the table above.
To add more function keys for more speed increases use this calculation:
Lowest speed (sound) step for the first key defined in CV #339 + (16 * (number of keys – 1)).
Example: F4 is defined as the first key in CV #339, which is supposed to raise the speed from idle to the first cruise step. To add 3 more keys (F5 to 2nd cruise step, F6 to 3rd , F7 to 4th): 1 (first cruise step above idle) + 63 (4 * 16 – 1) = 64.
#315
Minimum interval for
random generator Z1
0 - 255
=
0 - 255 sec
1
The random generator generates internal pulses in irregular intervals that are used to playback a sound file assigned to the random generator. CV #315 defines the shortest possible interval between two consecutive pulses.
Sound samples are assigned to the random generator Z1 with the help of the procedure CV #300 = 101, see above! By de­fault, the compressor is assigned to Z1.
Special note to random generator Z1: The random generator Z1 is optimized for the compressor
(which should be played back shortly after the train has stopped); therefore the default assignment should be retained or at the most be used for a different compressor. CV #315 also determines the proper time the compressor is started af­ter coming to a stop!
#316
Maximum interval
for random generator
Z1
0 - 255
=
0 - 255 sec
60
CV #316 defines the maximum time interval between two consecutive pulses of the random generator Z1 (that is most often the start of the compressor after coming to a stop); the actually occurring pulses between the values in CV #315 and #316 are equally distributed.
It is especially convenient if the sound step can be raised manually with a function key when operating diesel engines.
Coasting and Notching functions are required for driving situtations where the engine sound
cannot be derived from speed, acceleration and load only.
Primarily in diesel locomotives (but not necessarily limited to diesels), the motor’s idle sound or a certain specified speed step sound is enforced by keystroke.
This method can be used for “downshifting” (often to neutral) as well as “upshifting” (i.e. elevated
idle for heating). Future software versions will expand this function to a fully independent sound effect.
7.8 Random and Switch input sounds
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 57
#317
Playback length for
random generator Z1
0 - 255
=
0 - 255 sec
5
The sound sample assigned to the random generator Z1 (most often the compressor) is played back for the number of times defined in CV #317.
= 0: Sample plays once (in the defined duration)
#318 #319 #320
As above but for
sound generator Z2
0 - 255 0 - 255 0 - 255
20 80 5 By default, Z2 is assigned for coal shoveling at stand-still.
#321 #320 #323
As above but for
sound generator Z3
0 - 255 0 - 255 0 - 255
30 90 3 By default, Z3 is assigned for the injector at stand-still.
#324 #325 #326
As above but for
sound generator Z4
0 - 255 0 - 255 0 - 255
As delivered, this random generator is not assigned to any sound.
#327 #328 #329
As above but for
sound generator Z5
0 - 255 0 - 255 0 - 255
As delivered, this random generator is not assigned to any sound.
#330 #331 #332
As above but for
sound generator Z6
0 - 255 0 - 255 0 - 255
As delivered, this random generator is not assigned to any sound.
#333 #334 #335
As above but for
sound generator Z7
0 - 255 0 - 255 0 - 255
As delivered, this random generator is not assigned to any sound.
#336 #337 #338
As above but for
sound generator Z8
0 - 255 0 - 255 0 - 255
As delivered, this random generator is not assigned to any sound.
#341
Switch input 1
Playback duration
0 - 255
=
0 - 255 sec
0
The sound sample allocated to switch input 1 is played back for the duration defined with this CV.
= 0: Play back once (duration as recorded)
#342
Switch input 2
Playback duration
0 - 255
=
0 - 255 sec
0
The sound sample allocated to switch input 2 is played back for the duration defined with this CV.
= 0: Play back once (duration as recorded)
#343
Switch input 3
(if not used for the
cam sensor)
Playback time
0 - 255
=
0 - 255 sec
0
The sound sample allocated to switch input 3 is played back for the duration defined with this CV.
= 0: Play back once (duration as recorded)
CV
Designation
Range
Default
Description
4
#1
Short address
1 – 127
3
The “short” address; active when Bit 5 in CV #29 is
0. 6 #2
Start voltage
1 - 255
1
Internal speed step for lowest external speed step.
7
#3
Acceleration rate
0 - 255
(2)
Multiplied by 0.9 equals’ acceleration time.
7
#4
Deceleration rate
0 - 255
(1)
Multiplied by 0.9 equals’ deceleration time.
6
#5
Top speed
0 - 255
1 (=255)
Internal speed step for highest external speed step.
6
#6
Medium speed
32 - 128
1 (=1/3 # 5)
Internal speed step for medium external speed step.
3
#7
SW-Version number
Read-
only
-
The current SW number; for subversion see CV #65.
3
#8
Manuf.-ID, Reset, Set
0, 8, Set
#
145 (ZIMO)
given by the NMRA; CV #8 = 8 Hard Reset.
6
#9
Motor regulation.
1 - 255
55
Sample time (tens digit), sample rate (ones digit)
8 CV – Summery List
This list summarizes all CV's in numerical order, with very short descriptions (as a reminder). Detailed information can be found in the preceding chapters ("Configure", "ZIMO Sound").
The “red” column: Denotes the subchapter in chapter 3 “Addressing, Programming” or another main chapter.
Page 58 Large-scale Decoder & Sound Decoder MX695/6/7/9
CV
Designation
Range
Default
Description
6
#10
Compensation-Cutoff
0 - 252
0
Internal speed step, where BEMF intensity per CV#113.
-
#11
------
- #12
------
5
#13
Analog functions F1 -
F8
0 - 255
0
Select analog functions F1 (Bit 0), F2 (Bit 1)...
5
#14
Analog funct. F0, F9 …
0 - 255
0
Select analog functions, F0 forw (Bit 0), rev (Bit 1)...
-
#15
------
- #16
------
4
#17,18
Extended address
128 -
10239
0
The long address. Active when CV #29, Bit 5 = 1.
4
#19
Consist address
0 - 127
0
Consist address active when > 0.
4
#21
Consist function F1 -
F8
0 - 255
0
Select consist functions F1 (Bit 0), F2 (Bit 1)….
4
#22
Consist function F0
0 - 3
0
Select consist function F0 forw (Bit 0), rev (Bit 1).
7
#23
Acceleration variation
0 - 255
0
For temporary adjustment to CV #3
7
#24
Deceleration variation
0 - 255
0
For temporary adjustment to CV #4
-
#25
------
- #26
------
1 0
#27
Asym. Stop (ABC)
0, 1, 2, 3
0
Bit 0 = 1: Stop, with right rail Bit 1: left rail
2
#28
RailCom Configuration
0, 1, 2, 3
3
Bit 0 = 1: RailCom (Broadcast) Bit 1 = 1: Data
2
#29
DCC
Basic Settings
0 - 63
14 =
0000 1110 with Bits 1,
2, 3 (28 SS,
Analog,
RailCom)
Bit 0 – Direction: 0 = normal, 1 = reversed Bit 1 – Speed step system: 0 = 14, 1 = 28, 128 Bit 2 – Automatic analog operation Bit 3 – RailCom: 0 = OFF, 1 = ON Bit 4 – Speed curve: 0 = 3-point, 1 = free definition Bit 5 – Short/long address: 0 = CV #1, 1 = CV‘s #17,18
1 4
#33
NMRA Function map
F0
0 - 255
1
Function mapping for F0 forward
1 4
#34
NMRA Function map
F0
0 - 255
2
Function mapping for F0 reverse
1 4
#35-46
Function mapp. F1 -
F12
0 - 255
4,8,2,4,8,..
.
Function mapping for F1 ... F12
-
#47
------
-
#48
------
9
#49
HLU Acceleration
0 - 255
0
Multiplied by 0.4 = signal controlled acceleration
9
#50
HLU Deceleration
0 - 255
0
Multiplied by 0.4 = signal controlled deceleration
9
#51-55
HLU Limits
0 - 255
20,40,…
Speed step for each of the 5 HLU speed limits
6
#56
Motor regulation
1 - 255
55
PID regulation: P-Value (tens digit), I-Value (Ones digit)
CV
Designation
Range
Default
Description
6
#57
Voltage reference
0 - 255
0
Value = 1/10 of fixed voltage. “0” = track voltage.
6
#58
BEMF intensity
0 - 255
255
Load compensation at low speeds
9
#59
HLU Reaction time
0 - 255
5
Delay for HLU changes, in tenth of a second
1 8
#60
Dimming
0 - 255
0
Reduction of function output voltage through PWM.
1 4
#61
ZIMO ext. mapping
1,2...97,
98
0
Configurations not covered by NMRA mapping
2 1
#62
Light effects mod.
0 - 9
0
Adjusts minimum dim value
2 1
#63
Light effects mod.
0 - 99
51
Cycle time (tens digit), Off-time extension (ones dig­it)
2 1
#64
Light effects mod.
0 - 9
5
Ditch light off-time modification
3
#65
SW-Subversion #
0 - 255
-
Completes the version number in CV #7.
6
#66
Forward trimming
0 - 255
0
Multiplies speed step by trim value/128
6
#67-94
Free speed table
0 - 255
0
Internal speed step for each of the 28 external steps
6
#95
Reverse trimming
0 - 255
0
Multiplies speed step by trim value/128
-
#96 ...
------
-
105, 6
User data
0 - 255
0
Free memory space for user data
1 6
#107
Light suppression
0 - 255
0
Light suppression for cab 1 (forward)
1 6
#108
Light suppression
0 - 255
0
Light suppression for cab 2 (rear)
-
109 …
------
1,
6,
2 0
#112
Special ZIMO
configuration bits
0 - 255
4 =
00000100
also Bit 2 = 1
(Loco ID puls-
es ON, 20 kHz)
Bit 1 = 1: High frequency acknowledgements Bit 2 = 0 / 1: ZIMO loco ID ON/OFF Bit 3 = 1: 8 Functions-Mode (for old ZIMO systems) Bit 4 = 1: Pulse chain recognition (for old LGB­System) Bit 5 = 0 / 1: Motor control at 20 kHz or 40 kHz Bit 6 = 1: „Märklin“-Braking (+ CV # 29, Bit 2, # 124,
5)
6
#113
BEMF reduction
0 - 255
0
Intensity reduced at speed step defined in CV #10.
18
#114
Dim Mask 1
Bits 0 - 7
0
Individual outputs exempted from dimming per CV #60
23
#115
Uncoupler control
0 - 99
0
Eff 48: Pull-in V. (tens digit), Hold voltage (ones digit)
23
#116
Autom. uncoupling
0 - 199
0
Unload (Hundredth) Separat.(Tens), speed (Ones digit)
19
#117
Flasher
0 - 99
0
ON time (Tens digit), OFF time (Ones digit)
19
#118
Flasher mask
Bits 0 - 7
0
Function outputs included for flashing as per CV #117.
18
#119
F6 low beam mask
Bits 0 - 7
0
Enter FO for low-beam switching with F6 as per CV #60
18
#120
F7 low beam mask
Bits 0 - 7
0
Enter FO for low-beam switching with F7 as per CV
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 59
CV
Designation
Range
Default
Description
#60
7
#121
Expon. acceleration
0 - 99
0
Speed range included (Tens digit), curve (Ones digit)
7
#122
Expon. deceleration
0 - 99
0
Speed range included (Tens digit), curve (Ones digit)
7
#123
Adapt. accel./decel.
0 - 99
0
Accel. Convergence (Tens dig.), Decel. Conv. (Ones…)
13
#124
Shunting keys, Out-
puts instead of SUSI
Bits 0-4,
6
0
Shunting key (for half speed, accel. deactivation), Switch between SUSI – Logic level outputs
21
#125 #126 #127 #128 #129 #130 #131 #132
Effects F0 front
F0 rear
F1 F2 F3 F4 F5 F6
0 - 255
0
Bits 1, 0 = 00: directional (active in both directions) = 01: only forward = 10: only reverse
Bits 7, 6, 5, 4, 3, 2 = Effect-Code, i.e.:
Uncoupler - 00110000 = “48” Soft-Start for function output - 00110100 = “52” Autom. Brake light - 00111000 = „56“ and so on.
23
#133
------
10
#134
Asymm. stops (ABC)
1-
14,101,,
106
Sensitivity (Hundredth), Threshold (Tens, ones digit).
8
#135
km/h - Control
2 - 20
0
= 1 Calibration run; 5, 10, 20: Relation km/ spd. step
8
#136
km/h - Control
or:
RailCom
Contr. value after cal-run; or correct. value for Rail­Com
22
#137 #138 #139
Smoke generator
characteristics
0 - 255 0 - 255 0 - 255
0 0 0
Eff 72,80: CV #137: PWM of FOx at stand still CV #138: PWM of FOx at cruising speed CV #139: PWM of FOx during acceleration
12
#140
Distance controlled
stopping
0-3,11-
13
0
= 1: HLU or ABC = 2: manual = 3: both
12
#141
Distance controlled stopping
0 - 255
0
“Constant distance”: Stop point = 155: 500 m
12
#142
Distance controlled stopping
0 - 255
12
High speed correction for ABC
12
#143
Distance controlled stopping
0 - 255
0
High speed correction for HLU
1
#144
Prog,/ Update Lock
Bits 6, 7
0
Bit 6 = 1: „Service mode“-Lock, Bit 7 = 1: Update­Lock
15
#145
------
7
#146
Gear backlash
compen.
0 - 255
0
Hundredth’ of a second at min. speed after dir.­change
6
147,…
Experimental-CV‘s
0 - 255
0
Special motor regulation settings
5
#151
Motor brake
0 - 9
0
= 1 … 9: Force and speed of application
18
#152
Dim Mask 2
Bits 0 - 7
0
Individual outputs exempted from dimming per CV #60 - #153
Continue w/o signal
0 - 255
0
Tenth of seconds: stop after losing DCC signal
-
#154
Special OEM-Bits
CV
Designation
Range
Default
Description
13
#155
Half-speed key
0 - 19
0
Function key selection (instead of CV #124)
13
#156
Momentum deact.
0 - 19
0
Function key selection (instead of CV #124)
13
#157
MAN key
0 - 19
0
Function key selection
4.
#158
Several sound bits +
RailCom variants
0 - 127
0
Bit 2 = 0: RailCom speed (kph) – feedback using ID 4 = 1: Standardized feedback method using ID 7.
21
#159 #160
Effects on F7
F8
0 - 255
0
Same as CV“s #125 – 132 but for F7 and F8
25
#161
Servo Protocol
0 - 3
0
Bit 0 = 0: positive pulses , = 1: negative pulses Bit 1 = 0: active only w. moving, = 1: always active
25
#162 #163 #164 #165
Servo 1 left stop Servo 1 right stop Servo 1 center stop Servo 1 speed
0 - 255
49 205 127
30
Defines left stop position Defines right stop position for 3-position control Time in tenth of seconds between left and right stop
25
#166 #167 #168 #169
Servo 2 left stop Servo 2 right stop Servo 2 center stop Servo 2 speed
0 - 255
49 205 127
30
Defines left stop position Defines right stop position for 3-position control Time in tenth of seconds between left and right stop
25
#170 #171 #172 #173
Servo 3 left stop Servo 3 right stop Servo 3 center stop Servo 3 speed
0 - 255
49 205 127
30
Defines left stop position Defines right stop position for 3-position control Time in tenth of seconds between left and right stop
25
#174 #175 #176 #177
Servo 4 left stop Servo 4 right stop Servo 4 center stop Servo 4 speed
0 - 255
49 205 127
30
Defines left stop position Defines right stop position for 3-position control Time in tenth of seconds between left and right stop
25
#181 #182 #183 #184
Servo 1 Servo 2 Servo 3 Servo 4
0 - 114
0 0 0 0
Operating modes (One key, two keys …)
25
#185
Special live steam
1 - 3
0
Operating settings for live steam engines
--
#186-
189
Special pantograph
configurations
-
0
Pantograph settings for special projects
5
#190 -
191
Dimming times with ef-
fect 88
0-255
Turn-ON/OFF times for effects 88, 89 and 90
3
#250,
251,
252,
253
Decoder-ID
Read-
only
-
Decoder’s serial number
3
#260,
261,
262,
263
Lade-Code
- - for authorization of "coded" sound-projects
-
#264
------
4
-
#265
Select sound-
collection
1, 2, 3,
1
= 1, 2, … 32: Select among the stored sounds
5
-
#266
Total volume
0 - 65
(255)
65
!!: >65: Over modulated, may damage speaker
Page 60 Large-scale Decoder & Sound Decoder MX695/6/7/9
CV
Designation
Range
Default
Description
5. 4
#395 –
397
Volume Keys
- 0 Volume adjustments with function keys
5. 4
#376
Volume driving sound
0 – 255
255
Reduction of motor sound compared to total volume
5
-
#267
- 766
Sound-Parameter
-
-
Sound generation settings (see sound CV table above)
18
#400 #401
…..
#428
Input-Mapping
0 - 255
0
External function (Function key) for internal F0 External function (Function key) for internal F1 …… External function (Function key) for internal F28
9 Service Instructions
Even Zimo decoders can break down ... sometimes "for no reason", sometimes due to short circuits in the wiring, sometimes by a failed update ... These defective decoder can of course sent to Zimo for repair or replacement. Whether this is covered by warranty or a payable service, the submitter should expect a decoder back that is not only functional, but is also configured similarly as the original (i.e. the same CV values and the same sound project). However, this is not possible if the decoder is damaged so badly that it cannot be read-out anymore.
THEREFORE ... is it recommended to READ OUT IMPORTANT DATA from the decoder before it is defective and to send this information along with the decoder to ZIMO for repair.
Other information required: Address
Loaded SW version (CV #7, 65) Possibly activated CV Set (activation code for CV #8, concerns non-sound decoder) Decoder ID (CV #250 ... 253, if available) Possibly load code (CV #260 ... 263, relates to sound decoder) Loaded sound project.
It would also be very useful (but relatively complex) to read out the entire CV list and keep it in a safe place, so it can later be programmed to a repaired decoder (which sometimes requires
Large-scale Decoder & Sound Decoder MX695, MX696, MX697, MX699 Page 61
a hard-reset) or a replacement. Reading out and reprogramming decoders is easy with the help of
the program "ADaPT" (from E.Sperrer, works with Zimo and some other DCC systems), or ZSP (works with MX31ZL MXDECUP or, in the future, with MXULF or MX10) or with ZSC (works with MXULF in the future or MX10). NOTE: Future Zimo command stations will read decoder configurations automatically (in the background) and make it available when needed. But is at the time of this writing (May 2013) still future...
ADDITIONAL INFORMATION relating to submission of defective decoders:
To avoid unnecessary repair shipments it should be verified beforehand whether a
defect is in fact present. Quite a few of the submitted decoders are only configured wrongly and all that was needed was a "hard reset" (CV #8 = 8) to get the decoder CV’s back to the default values or the default values of a sound project.
WARNING: Sometimes defects are simulated when a loaded sound project or its in-
tegrated CV table expects a specific loco model (e.g., certain types of lighting equipment), but the equipment is missing or not wired appropriately. Typical cases: The light is no longer working with F0 (because the sound project has redirected the light to another function key), or locomotive will "drive off unchecked" (because the sound project activated a servo with a corresponding uncoupling procedure). Note: for the individual sound projects in the Zimo sound database, there is usually also a version that contains only the sound and no specially prepared vehicle is re­quired.
If the problem is “only” very poor drivability, it would be of advantage to contact
service@zimo.at before sending the decoder back. Often a simple remedy can be
found without sending the decoder back.
ZIMO can only accept decoders for repair, BUT NOT complete engines or engine
parts with a decoder installed. There are of course exceptions in problematic cases that have to do with the interaction between the locomotive and decoder, but only af­ter prior agreement.
The defect (or reason for return) should be described with as much detail as possi-
ble in addition to the above mentioned information required.
So called OEM decoder, such as have been installed by a loco manufacturer, should
be taken care of by them. However, ZIMO will repair these as well when sent to the ZIMO service department. The warranty and repair conditions may of course differ from those of the vehicle manufacturer (whether this is "better" or "worse" is rather coincidence). Even in these cases: submit only the Zimo decoder, not complete en­gines!
If a decoder gets exchanged, the original OEM sound project can in most cases be used in the replacement decoder as well (if the necessary information has been submitted to us). This ap­plies to vehicle manufacturers like Roco, Fleischmann, Wunder, Demko and many others, but it is also possible that ZIMO does not have the sound from manufacturers that provided the sound themselves.
"Preloaded" sound projects (see Sound Database), however, are usually NOT avail-
able from Zimo, but only the author / company who usually provides the sound only preloaded in a decoder. Such sound decoders are therefore better sent directly to the original supplier. Naturally if the problem is a pure hardware issue, such as a de­fective motor or function output, it can be dealt easily at ZIMO.
Please fill out and accompany a ZIMO repair form with your shipment. Such forms can be downloaded here:
http://www.zimo.at/web2010/sales/Reparatur-Formular_en.pdf
Loading...