Away Mode
The Thermostat can be put into Away mode when the user leaves the house by pressing the
Away button.
To program Away Mode setting, press and hold Mode button for 3 seconds. You will first
program Away Cool set point, press Mode button after finish setting to program Away Heat
set point, the Cool set point must be at least 2℃ higher then Heat set point. Press Mode
button again to program Fan setting when done.
Fan Setting
When in Fan setting, press UP or Down button to select fan option between Always on or
Auto mode.
Always On ( icon steady on) – The fan is always turned on except under Off Mode
Auto mode ( icon flash) – The fan will be turned on according to Away, Cool and Heat
mode setting.
Off Mode
The Thermostat can be put into Off mode by pressing and holding the Away button for 3
seconds. When under Off mode, the Thermostat stop all function and only display current time.
Time / Temperature Display / HVAC Type Setting:
Press and hold the Mode button for 10 seconds to enter setting mode. The time on LCD display
will begin to flash:
Use the Up and Down buttons to select time and Mode button to proceed to next option.
Available options include:
1.
Weekday
2.
Hour
3.
Minute,
4.
AM/PM or 24-hour format display. (You can only change the time display format when
the time is set to between 1:01~12:59)
5.
Celsius or Fahrenheit display
6.
HVAC type: Type 1 = Gas/Electric, Type 2 = Heat Pump(O), Type 3 = Heat Pump(B).
Factory Default HVAC Type = 1 Gas/Electric
HVAC Type
According to the HVAC system in the home environment, select the HVAC type in Thermostat
setting.
Type 1: General Gas/Electric HVAC system
Type 2: HVAC system with Reversing Valve which operates during Cooling (Heat Pump “O”)
Type 3: HVAC system with Reversing Valve which operates during Heating (Heat Pump “B”)
Remote Control
After the Thermostat joins a ZigBee network, you can control the Thermostat via ZigBee network
coordinator or gateway. Please refer to your ZigBee coordinator/gateway manual for more
information.
The following functions are only available for setting via ZigBee coordinator and gateway:
Schedule:
You can only program Schedule configuration via ZigBee network coordinator/gateway.
Schedule Setting: Up to 5 schedules can be programmed for every weekday with Mode,
Setpoint and Start time.
Schedule Control:
Normal - The Thermostat will execute programmed schedule setting accordingly.
Hold – The Thermostat will bypass currently timed schedule and perform the next schedule
when it begins
No Schedule – The Thermostat will not execute any set schedule until it is set to Normal again.
Temperature Detection
The Thermostat has built-in temperature sensors and will display the temperature reading on
the LCD display
The Thermostat will transmit temperature signals regularly according to setting. The factory
default interval is 10 minutes.
When the temperature changes by +/- 2˚C, the Thermostat will also transmit a signal.
You can also press the ZigBee Network Button once to transmit a temperature signal manually.