Zigbee Smart Humidity Sensor Installation Manual

eng
Smart Humidity Sensor
INSTALLATION MANUAL
Version 1.2
Product description
The Smart Humidity Sensor allows you to
protect your building and belongings by
monitoring the temperature and humidity
levels, and receive immediate alerts if the
climate uctuates to unsafe levels.
By supervising the indoor climate, the wireless
Smart Humidity Sensor helps maintain the
ideal comfort level and protect interior,
electronics, musical instruments, furniture,
artwork, and other humidity-sensitive
household items.
Do not place the Smart Humidity Sensor under direct sunlight or bright light.
Avoid placing the Smart Humidity Sensor
close to radiators or electromagnetic elds.
Do not paint the sensor.
Getting started
1. Open the sensor by pushing the switch and
pulling the top of the casing.
a.
2. Insert two AA batteries respecting the
polarities.
3. The Smart Humidity Sensor will now start
searching (up to 15 minutes) for a Zigbee
network to join.
b.
4. Make sure that the Zigbee network is open
for joining devices and will accept the Smart Humidity Sensor.
5. While the Smart Humidity Sensor is search- ing for a Zigbee network to join, the LED
Placement
Place the sensor indoors at a temperature between 0-50°C.
Inside the room, in which you want to
monitor humidity levels.
The Smart Humidity Sensor should be placed on a wall, reachable for battery testing and maintenance.
d.
WALL
50 cm
150 cm
Mounting
1. Open the casing of the Smart Humidity
Sensor and remove the batteries.
e.
2. Use double-sided tape or screws to attach
the sensor on the wall.
f.
3. Insert batteries respecting the polarities.
g.
3. Make sure that the Smart Humidity Sensor has
joined a network before closing the casing.
Resetting
Resetting is needed if you want to connect
your Smart Humidity Sensor to another
gateway or if you need to perform a factory
reset to eliminate abnormal behaviour.
STEPS FOR RESETTING
1. Open the casing of the Smart Humidity
Sensor.
2. Press and hold the round menu button
h.
inside the device.
3. While you are holding the button down, the
LED rst ashes once, then two times in a
row, and nally numerous times in a row.
4. Release the button while the LED is ashing
numerous times in a row.
5. After you release the button, the LED shows
Battery replacement
The device will blink twice every minute when
the battery is low.
CAUTION: RISK OF EXPLOSION IF BATTERIES
ARE REPLACED BY AN INCORRECT
TYPE. DISPOSE OF THE BATTERIES IN
ACCORDANCE WITH INSTRUCTIONS.
CAUTION: When removing cover for battery
change - Electrostatic Discharge (ESD) can
harm electronic components inside.
1. Open the casing of the Smart Humidity
Sensor to replace the batteries.
i.
2. Replace the batteries respecting the
polarities.
j.
3. Close the casing of the sensor.
Disposal
Dispose the product and batteries properly at
the end of life. This is electronic waste which
should be recycled.
Precautions
Do not remove the product label as it contains important information.
• Be aware that electronics are sensitive
to static electricity, so aim to discharge
before touching, and avoid touching any
components inside the device.
Do not place the Smart Humidity Sensor on the ceiling, or behind obstacles, such as curtains.
c.
ashes red.
6. When the LED stops ashing, the Smart
Humidity Sensor has successfully joined the Zigbee network.
Fault nding
If the search for a gateway has timed out, a
short press on the button will restart it.
• In case of a bad or wireless weak signal,
change the location of the Smart Humidity
Sensor. Otherwise, you can relocate your
gateway or strengthen the signal with a
smart plug.
FCC statement
FCC statement
Changes or modications to the equipment
not expressly approved by the party
responsible for compliance could void the
user’s authority to operate the equipment.
NOTE: This equipment has been tested and
found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide
reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses and can
radiate radio frequency energy and, if not
installed and used in accordance with the
instructions, may cause harmful interference
to radio communications. However, there is no
guarantee that interference will not occur in a
particular installation.
If this equipment does cause harmful
interference to radio or television reception,
which can be determined by turning the
equipment o and on, the user is encouraged
to try to correct the interference by one or
more of the following measures:
• Reorient or relocate the receiving antenna.
Increase the separation between the
equipment and receiver.
Connect the equipment into an outlet on a circuit dierent from that to which the
receiver is connected.
Consult the dealer or an experienced
radio/TV technician for help.
This device complies with FCC RF radiation
exposure limits set forth for an uncontrolled
environment. The antenna used for this
transmitter must be installed to provide a
separation distance of at least 20 cm from
all persons and must not be co-located
or operating in conjunction with any other
antenna or transmitter.
This device complies with part 15 of the FCC
Rules. Operation is subject to the following
two conditions:
1. This device may not cause harmful interfer- ence, and
2. this device must accept any interference
received, including interference that may cause undesired operation.
IC statement
English
This device contains licence-exempt
transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic
Development Canada’s licence-exempt
RSS(s). Operation is subject to the following
two conditions:
1. This device may not cause interference.
2. This device must accept any interference,
including interference that may cause
undesired operation of the device.
This equipment complies with IC RSS-102
radiation exposure limits set forth for an
uncontrolled environment. This equipment
should be installed and operated with
minimum distance 20 cm between the
radiator and your body.
Français
L’émetteur/récepteur exempt de licence
contenu dans le présent appareil est
conforme aux CNR d’Innovation, Sciences
et Développement économique Canada
applicables aux appareils radio exempts de
licence. L’exploitation est autorisée aux deux
conditions suivantes :
1. L’appareil ne doit pas produire de
brouillage;
2. L’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage
est susceptible d’en compromettre le
fonctionnement.
Cet équipement est conforme aux limites
d’exposition aux radiations IC CNR-102
établies pour un environnement non contrôlé.
Cet équipement doit être installé et utilisé
avec une distance minimale de 20 cm entre le
radiateur et votre corps.
ISED statement
ISED statement
Innovation, Science and Economic
Development Canada ICES-003 Compliance
Label: CAN ICES-3 (B)/NMB-3(B).
CE certication
CE certication
The CE mark axed to this product conrms
its compliance with the European Directives
which apply to the product and, in particular,
its compliance with the harmonized standards
and specications.
IN ACCORDANCE WITH THE DIRECTIVES
Radio Equipment Directive (RED) 2014/53/EU
RoHS Directive 2015/863/EU amending 2011/65/EU
Other certications
Zigbee Home Automation 1.2 certied.
All rights reserved.
frient assumes no responsibility for any
errors, which may appear in this manual.
Furthermore, frient reserves the right to alter
the hardware, software, and/or specications
detailed herein at any time without notice,
and frient does not make any commitment
to update the information contained herein.
All the trademarks listed herein are owned by
their respective owners.
Distributed by frient A/S Tangen 6 8200 Aarhus N
Denmark www.frient.com
Copyright © frient A/S
Loading...