![](/html/78/7835/7835ead9e8624f5c3f4397f6a9df19a5a27d3f14b9e53afec64325e7109c9621/bg1.png)
Pole Mounting Kits for the 4300 6U Outdoor Cabinet
Models PDN-4300-F1-600 and PDN-4300-F1-610
Installation Instructions
Document Number 4300-A2-ZZ49-00
November 2005
Product Overview
The Model PDN-4300-F1-600 and PDN-4300-F1-610 Pole Mounting Kits are used for mounting the 4300 6U
Outdoor Cabinet to a solidly anchored and supported pole from the back of the cabinet. Model PDN-4300-F1-600 is
for a cabinet without a battery pedestal and PDN-4300-F1-610 is for a cabinet with a battery pedestal. See the
figures on the following pages for details.
The mounting bracket is constructed of heavy gauge steel with a powder coat painted finish for superior corrosion
resistance.
Inspecting Shipment
On receipt of the equipment:
• Inspect the shipping container(s) and note any signs of damage. Then unpack the container(s) and carefully
inspect for damage to the contents. If the equipment has been damaged in transit, immediately report the extent
of damage to the transportation company and to your sales representative. Order replacement equipment, if
necessary.
• Check the packing list to ensure complete and accurate shipment of all listed items. If the shipment is short or
irregular, contact your sales representative. If the equipment must be stored for a prolonged period, do so in the
equipment's original container. If equipment ever needs to be returned, please use the original packaging if
available.
Zhone Technologies
@Zhone Way
7001 Oakport Street
Oakland, CA 94621
USA
Copyright © 2005
Zhone Technologies, Inc.
4300-A2-ZZ49-00 November 2005 1
![](/html/78/7835/7835ead9e8624f5c3f4397f6a9df19a5a27d3f14b9e53afec64325e7109c9621/bg2.png)
Pole Mounting Kits for the 4300 6U Outdoor Cabinet Installation Instructions
Pole Mounting – Cabinet without Pedestal
Use this procedure to mount the cabinet on a 6 to 8 inch diameter pole. See the figure below for a cabinet mounting
illustration.
Figure A - Pole Mounting Diagram (Cabinet without Pedestal)
2 November 2005 4300-A2-ZZ49-00
![](/html/78/7835/7835ead9e8624f5c3f4397f6a9df19a5a27d3f14b9e53afec64325e7109c9621/bg3.png)
Pole Mounting Kits for the 4300 6U Outdoor Cabinet Installation Instructions
Table 1 - Pole Mounting without Pedestal
Item No. Qty Description
003 1 Bracket, Vertical Pole Mount, 10U/13U
006 1 Bracket, Lower Pole Mount, Access
009 1 Bracket, Upper Pole Mount
012 4 Nut, Nylon Top Lock 3/8"
015 14 Washer, 3/8" Stainless Steel, SAE, Flat
018 10 Screw, 3/8-16 x 1", Stainless Steel, Cap
021 6 Washer, Split Lock, 3/8 ZP
024 6 Washer, 3/8", Flat, Rubber
027 2 Bolt, Square Head, 5/8-11 x 16 & Nut, Galvanized
030 2 Washer, Curved, 2 1/4 x 2 1/4 x 3/16, 5/8, Galvanized
033 2 Nut, 5/8, Galvanized (Included with Bolt)
036 2 Washer, Square, 2 1/4 x 2 1/4 x 3/16, 5/8, Galvanized
Have the following equipment ready before beginning this procedure:
One drill
One 3/4” x 12” drill bit
One 9/16” wrench
Two 15/16” wrenches
A pencil
Model PDN-4300-F1-600 Pole Mounting Kit
Follow this procedure for pole mounting:
1. Pre-assemble the upper and lower horizontal brackets to the vertical bracket as shown in the above Figure.
2. Select a convenient mounting location on the pole.
3. Position the mounting bracket assembly against the pole and mark on the pole the location of the two (2) 5/8 “
bolts (item 27).
4. Place the mounting bracket assembly out of the way.
5. Drill two (2) 3/4” (19.05 mm) diameter holes completely through the pole at the locations marked in step 3.
6. Insert machine bolt (item 27) through mounting bracket and into the top mounting hole and press bolt and
bracket flush against the pole.
7. Place round-cupped washer (item 30), with the concave side in, on bolt and finger tighten nut.
8. Repeat step 6 for the remaining bolt.
9. Secure the mounting bracket assembly to the pole by securely tightening the machine bolts to 40 ft-lbs for
wooden posts and 100 ft-lbs for metal posts.
4300-A2-ZZ49-00 November 2005 3