✓ Compact, 1U space
efficient design with
24-Ports of VDSL2 (up to
30a) and optional
integrated splitters
✓ Backward compatible with
legacy ADSL / ADSL2+
modems
✓ Downstream Power
Back-off (DPBO) minimizes
interference with adjacent
DSL services in the same
binder group
✓ Dual GigE Uplinks (2 SFP +
2 Built-In GE Uplink Ports)
with Link Aggregation
✓ VLAN/Bridge Forwarding
with QoS and Security
Features
✓ Stacking Support with
In-band Management
VDSL2 High Performance IP-DSLAM
Bitstorm-HP-150, Bitstorm-HP-160
24-Port G.993.2 Standards-based 100/100Mbps VDSL2
IP-DSLAM
The Bitstorm-HP family of products are 24-port VDSL2 IP-DSLAMs, featuring a
hardened, high performance design with efficient power and space considerations.
Designed as a 1U high product, the Bitstorm-HP is ideal for deployment in space
constrained indoor MDU or external cabinet locations to take advantage of short,
last-mile loops which are ideal for VDSL2 rate/reach performance.
The Bitstorm-HP family uses the latest VDSL2 silicon technology from Ikanos, and can
support all eight (8) VDSL2 profiles (up to 30a) to deliver up to 100/100Mbps
Up/Down line-rate when paired with a Zhone's VDSL2 CPE (6652-A2). The lower cost
Bitstorm-HP-150 models support up to Profile 17a, delivering line rates up to 100Mbps
Down / 50Mbps Up. All Bitstorm HP models fully interoperate with Zhone's VDSL2
6652-A2 (30a, Bridge/Router) and 6652-A1 (17a, Smart Bridge) modems. The
Bitstorm-HP family is also backward compatible with ADSL/ADSL2+ when connected
to industry-standard ADSL2+ modems, thus providing an easy migration path for
users running legacy ADSL services, while providing expanded revenue opportunities
when deploying new high-speed VDSL2 services.
The Bitstorm-HP family delivers very high-speed line-rate performance and supports
triple play services implemented on a powerful Network Processor. The Bitstorm-HP is
designed with separate control and data paths to allow high bit-rate services while
supporting advanced L2/L3 features such as - DHCP (Option-82), IGMP
Snooping/Proxy, IP/ARP Spoofing, Forced MAC Forwarding, QoS and
Security/Filtering in either Bridged or VLAN Switched operating modes.
✓ Hardened for Outside
Plant Deployment (DC
models)
The Bitstorm-HP also supports configurable, Downstream Power Back-off (DPBO)
capabilities for both ADSL and VDSL2. Sometimes used in remote cabinet
applications, DPBO equips service providers with the ability to adjust the transmit
power levels of each port to be at the same level as would be expected to be found at
the same point in the cable if the signal had been injected at the central office
exchange. This advanced functionality can be used to ensure that the ADSL2/VDSL2
services from the Bitstorm-HP do not adversely impact other DSL services that may
exist in the same outside plant binder group.
Available with optional, built-in POTS splitters (600 or 900 ohm) as well as DC or AC
powering options, the Bitstorm-HP features an intuitive Web Graphical Interface for
device configuration and management and can also be managed using Secure Shell
(SSH), Telnet (CLI) or SNMPv1/v2.

VDSL2 High Performance IP-DSLAM
IP
/ Data
Network
Bitstorm-HP
VDSL2 IP-DSLAM
Main
Distribution
Frame
Multi Dwelling
Unit (MDU)
Multiple
HDTV / SDTV
Data
10 / 100 Mbps
Voic e
VDSL2
100 / 100 Mbps
6652-A2-302
VDSL2 Modem
The Bitstorm-HP is ideally suited for deployment in Multi Dwelling Units
(MDU) for the delivery of bandwidth intensive services such as HDTV,
Video Conferencing, Interactive Gaming and symmetric E-Line business
services. The Bitstorm-HP models support dual Gigabit Ethernet uplinks
which can be aggregated using a standards-based line aggregation
protocol (LACP 802.3ad). This allows deep-fiber deployment and
interface with Ethernet Metro switches.
Operators providing business services can utilize feature-rich traffic
management and security functions to provide guaranteed service levels
and prevent malicious user behavior. Some of the supported features
include: Prevent traffic flooding between line bridge ports; configurable
rate-limit per bridge port per VLAN; IGMP broadcast limit per line port;
MAC address spoofing; IP/ARP spoofing; IP-Allow filter based on DHCP
snooping; Forced destination MAC address forwarding.

Technical Specifications
Dimensions
■ 1.75" x 17" x 10.4" (HxWxD)
■ 44mm x 432mm x 265mm (HxWxD)
Power
■ Source:
- DC: 42V to -56V; Dual A+B feeds
- AC: 100V - 240V (50~60Hz)
■ Power:
- 75 watts (nominal)
- 90 watts (max)
Interfaces
■ 24-ports VDSL2
■ Backward compatible with ADSL / ADSL2+
■ Two (2) 100/1000Mbps Ethernet Combo Ports -
Electrical or Optical (SFP)
■ Management Ethernet
■ Serial Console
VDSL2 High Performance IP-DSLAM
Standards Support
■ VDSL2 ITU-T G.993.2
■ Profile 8a/8b/8c/8d/12a/12b/17a/30a
■ ADSL and ADSL2+ Backward Compatible
■ 802.1q VLAN, 802.1p VLAN Priority
■ VLAN Q-in-Q
■ Spanning Tree Protocol (IEEE 802.1d/w)
■ Link Aggregation (IEEE 802.3ad)
■ DHCP (Option 82)
■ RFC 4562: Forced MAC Forwarding
Protocol Support
■ PPPoE Intermediate Agent (DSL-Forum)
■ IGMP Snooping/Proxy
■ Ethernet RMON
■ VDSL/ADSL Performance Counters
■ 15-min 1-day counters for history record
Management
■ Web-based Graphical User Interface
■ Telnet CLI and SSH
■ RFC 1213 SNMP MIB II
■ RFC 1493 Bridge MIB
■ RFC 1643 Ethernet MIB
■ RFC 2674 Q MIB
■ RFC 1757 RMON MIB, group 1,2,3,9
■ ADSL MIB
■ VDSL MIB
Regulatory Compliance
■ ITU-T K.20, K.21
■ ETSI 300-019, 300-386
■ EN 60950
■ ROHS Compliance
■ Conform to CE requirements
Operating Requirements
■ Operating (DC): -40°C to 65°C
■ Operating (AC): -10°C to 50°C
■ Storage: -40°C to 80°C
■ Relative Humidity: Up to 95% (non-condensing)

VDSL2 High Performance IP-DSLAM
Ordering Information
Bitstorm-HP VDSL2 17a IP-DSLAM Models
BITSTORM-HP2-150-AC-EU 24-PORT VDSL2 (IKNS), 5-BAND (17A), VERT. T/R, EURO AC, WITHOUT SPLITTERS, REV 2 FANS
BITSTORM-HP2-150-AC-NA 24-PORT VDSL2 (IKNS), 5-BAND (17A), VERT. T/R, NA AC, WITHOUT SPLITTERS, REV 2 FANS
BITSTORM-HP-150-DC 24-PORT VDSL2 (IKNS), 5-BAND (17A), VERT. T/R, -48V DC, WITHOUT SPLITTERS
BITSTORM-HP2-151-AC-EU 24-PORT VDSL2 (IKNS), 5-BAND (17A), VERT. T/R, EURO AC, 600 OHM SPLITTERS, REV 2 FANS
BITSTORM-HP2-151-DC 24-PORT VDSL2 (IKNS), 5-BAND (17A), VERT. T/R, -48V DC, 600 OHM SPLITTERS, REV 2 FANS
BITSTORM-HP-152-AC-NA 24-PORT VDSL2 (IKNS), 5-BAND (17A), VERT. T/R, NA AC, 900 OHM SPLITTERS
BITSTORM-HP-152-DC 24-PORT VDSL2 (IKNS), 5-BAND (17A), VERT. T/R, -48V DC, 900 OHM SPLITTERS
Bitstorm-HP VDSL2 30a IP-DSLAM Models
BITSTORM-HP2-160-AC-EU 24-PORT VDSL2 (IKNS), 6-BAND (30A), HORIZ. T/R, EURO AC, NO SPLITTERS, REV 2 FANS
BITSTORM-HP-160-AC-NA 24-PORT VDSL2 (IKNS), 6-BAND (30A), HORIZ. T/R, NA AC, NO SPLITTERS
BITSTORM-HP-160-DC 24-PORT VDSL2 (IKNS), 6-BAND (30A), HORIZ. T/R, DC, NO SPLITTERS
BITSTORM-HP-161-AC-EU 24-PORT VDSL2 (IKNS), 6-BAND (30A), HORIZ. T/R, EURO AC, 600 OHM SPLITTERS
BITSTORM-HP2-161-DC 24-PORT VDSL2 (IKNS), 6-BAND (30A), HORIZ. T/R, DC, 600 OHM SPLITTERS, REV 2 FANS
BITSTORM-HP2-162-AC-NA 24-PORT VDSL2 (IKNS), 6-BAND (30A), HORIZ. T/R, NA AC, 900 OHM SPLITTERS, REV 2 FANS
BITSTORM-HP-162-DC 24-PORT VDSL2 (IKNS), 6-BAND (30A), HORIZ. T/R, DC, 900 OHM SPLITTERS
VDSL2 BRIDGE/ROUTER MODEMS
6652-A1-200 VDSL2+ CPE, 4-PORT BRIDGE, CPE4 (17A), NA PLUG
6652-A1-302 VDSL2+ CPE, 4-PORT BRIDGE, CPE4 (17A), EU PLUG
6652-A2-200 VDSL2+ CPE, 4-PORT BRIDGE/ROUTER, CPE5 (30A), NA PLUG
6652-A2-302 VDSL2+ CPE, 4-PORT BRIDGE/ROUTER, CPE5 (30A), EU PLUG
6652-A2-600 VDSL2+ CPE, 4-PORT BRIDGE/ROUTER, CPE5 (30A), JAPAN
Fiber SFP
SFP-GE-LX-1310-DLC LONG-REACH (10KM) OPTICAL GIGABIT ETHERNET
SFP-GE-SX-850-DLC SHORT-REACH (500M) OPTICAL GIGABIT ETHERNET
VDSL2 30a Cable [for LINE Interface on Bitstorm-HP-16x models]
HP-160-VDSL2-CABLE-RJ21-15FT CONVERSION CABLE HORIZONTAL T/R to VERTICAL T/R, 15-Feet, RJ21 (MALE)-to-RJ21(MALE)
HP-160-VDSL2-CABLE-RJ21F-15FT CONVERSION CABLE HORIZONTAL T/R to VERTICAL T/R, 15-Feet, RJ21 (MALE)-to-RJ21 (FEAMLE)
HP-160-VDSL2-CABLE-OPEN-15FT CONVERSION CABLE HORIZONTAL T/R to VERTICAL T/R, 15-Feet, RJ21 (MALE)-to-Stub
17 December 2010 11:35:32