Appendix Toxic or Hazardous Materials or Elements ...............................................................16
iii
1 Structure
1.1 Device Components
You can refer to the following figure for component information. See Figure 1-1.
Figure 1-1
Please refer to the following sheet for detailed information.
SN Port Name Indicator Connector Note
1
2
3
Power indicator
light
Network
indicator light
Speaker / /
POWER /
NET /
z When system boots up–Green
light becomes on.
z When system is upgrading –
Green light flashes. Interval is
0.5s.
z When system is alarming–
Green light flashes. Interval is
0.2s.
z Wire network connection-Red
light is on.
z Wireless network connection-
Green light is on.
Output audio signal.
(This function is optional. For some
series product only.)
4 White light / /
Can activate motion detect, PIR
human body movement detect,
external alarm.
1
SN Port Name Indicator Connector Note
5
6
7 Micro SD card Micro SD
PIR sensor PIR /
Microphone / /
Micro SD
card slot
Passive IR motion detect port. It
can detect the IR object movement
(such as human body or other
heating object).
Directly receive audio signal.
(This function is optional. For some
series product only.).
SD card storage.
(This function is optional. For some
series product only.).
Restore factory default setup.
8
9 WPS button WPS
10
11 Power port DC12V / Input DC 12V power.
12 Network port LAN
Reset button Reset /
Fast wireless
connection
Alarm pin / I/O port
Ethernet port
When system is running normally,
press the RESET button for at least
5 seconds, system can restore
factory default setup.
Press the WPS button of the router
and the device respectively for at
least 2 seconds. Usually the device
can connect to the router within 1
minute.
Please note it is for wireless
series product only and it is for
the wireless router of the WPS
function.
Alarm signal input/output
(This function is optional. For some
series product only.).
zConnect to standard Ethernet
cable.
zSupport PoE function.
1.2 Dimensions
Please refer to the following figure for dimension information. The unit is mm. See Figure 1-2.
2
Figure 1-2
1.3Bidirectional talk
1.3.1 Device-end to PC-end
Device Connection
Please connect the speaker or the MIC to the audio input port in the device rear panel. Then connect
the earphone to the audio output port in the PC.
Login the Web and then click the Audio button to enable the bidirectional talk function.
You can see the button becomes orange after you enabled the audio talk function.
Click Audio button again to stop the bidirectional talk function.
Listening Operation
Speak or play music at the PC-end, you can use the earphone or the sound box of the PC-end to
listen the audio information from the device-end.
1.3.2 PC-end to the Device-end
Device Connection
Connect the speaker or the MIC to the audio input port in the PC and then connect the earphone to the
audio output port of the device.
Login the Web and then click the Audio button to enable the bidirectional talk function.
You can see the button becomes orange after you enabled the audio talk function.
Click Audio button again to stop the bidirectional talk function.
Listening Operation
3
Speak or play music at the PC-end, you can use the built-in speaker of the device-end to listen.
Note
Please go to the Master Volume interface of the PC to set first if you want to use the dual-way
bidirectional talk. Please select Front Mic mode in the record control interface. (You can select
microphone enhanced in Advanced interface if the audio is too low.)
1.4 Alarm Setup
The alarm setup interface is shown as below. See Figure 1-3.
Figure 1-3
1.4.1 Alarm Input and Output Connection
Please refer to the following figure for alarm input information. See Figure 1-4.
Alarm input: When the input signal is idle or grounded, the device can collect the different statuses of
the alarm input port. When the input signal is connected to the 3.3V or is idle, the device collects the
logic “1”. When the input signal is grounded, the device collects the logic “0”.
Figure 1-4
Please refer to the following figure for alarm output information. See Figure 1-5.
Port NO and Port C composes an on-off button to provide the alarm output.
This button is normal open. The button becomes off when there is an alarm output.
4
Figure 1-5
5
2 Device Installation
This series camera support two installation modes: wall mount and pendant mount. See Figure 2-1
and Figure 2-2.
Important
Please make sure the installation surface can min support the 3X weight of the camera and the
bracket.
Step 1
Paste the installation positioning map on the installation surface such as wall, ceiling or the wood.
Step 2
Dig holes in the installation surface according to the installation positioning map.
Step 3
Insert the expansion bolts from the accessories bag to the holes you just dug. If it is the wood surface
you can skip to the next step.
Step 4
Use the screws from the accessories bag to secure the device firmly.
Step 5
Connect the cable and then boot up the device.
Step 6
Loosen the adjust knob for a little bit, adjust the camera to proper surveillance position according to
your actual requirements.
Step 7
Secure the knob of the bracket to fix the camera.
Figure 2-1
6
Figure 2-2
7
3 Quick Configuration Tool
3.1 Overview
Quick configuration tool can search current IP address, modify IP address. At the same time, you can
use it to upgrade the device.
Please note the tool only applies to the IP addresses in the same segment.
3.2 Operation
Double click the “ConfigTools.exe”icon, you can see an interface is shown as in Figure 3-1.
In the device list interface, you can view device IP address, port number, subnet mask, default
gateway, MAC address and etc.
Figure 3-1
Select one IP address and then right click mouse, you can see an interface is shown as in Figure 3-2.
Note:
You can set the IP address, subnet mask and gateway for the network camera and PC. Please note
network camera IP address and PC IP address shall be in the same network segment if there is no
router. Network camera default IP address is 192.168.1.108. If there is a router, please set the
corresponding gateway and subnet mask.
The factory default user name is admin and password is admin. For security reasons, please modify
your password after you first login.
For detailed WEB operation, please refer to the Web Operation Manual in the resource CD.
8
Figure 3-2
Select the “Open Device Web” item; you can go to the corresponding web login interface. See Figure
3-3.
Figure 3-3
If you want to modify the device IP address without logging in the device web interface, you can go to
the configuration tool main interface to set.
In the configuration tool search interface (Figure 3-1), please select a device IP address and then
double click it to open the login interface. Or you can select an IP address and then click the Login
button to go to the login interface. See Figure 3-4.
In Figure 3-4, you can view device IP address, user name, password and port. Please modify the
corresponding information to login.
Please note the port information here shall be identical with the port value you set in TCP port in Web
Network interface. Otherwise, you can not login the device.
If you are using device background upgrade port 3800 to login, other setups are all invalid.
9
Figure 3-4
After you logged in, the configuration tool main interface is shown as below. See Figure 3-5.
Figure 3-5
For detailed information and operation instruction of the quick configuration tool, please refer
to the Quick Configuration Tool User’s Manual included in the resources CD.
10
4 Web Operation
These series network camera products support the Web access and management via PC.
Web includes several modules: Monitor channel preview, system configuration, alarm and etc.
.
4.1 Network Connection
Please follow the steps listed below for network connection.
z Make sure the network camera has connected to the network properly.
z Please set the IP address, subnet mask and gateway of the PC and the network camera
respectively. Network camera default IP address is 192.168.1.108. Subnet mask is 255.255.255.0.
Gateway is 192.168.1.1
zUse order ping ***.***.***.***(* network camera address) to check connection is OK or not.
4.2 Login and Logout
Open IE and input network camera address in the address bar.
For example, if your camera IP is 192.168.1.108, then please input http:// 192.168.1.108 in IE address
bar. See Figure 4-1.
Figure 4-1
The login interface is shown as below. See Figure 4-2.
Please input your user name and password.
Default factory name is admin and password is admin.
Note: For security reasons, please modify your password after you first login.
Input your IP
address here
11
Figure 4-2
If it is your first time to login in, system pops up warning information to ask you whether install control
webrec.cab
automatically install the control. When system is upgrading, it can overwrite the previous Web too.
If you can’t download the ActiveX file, please check whether you have installed the plug-in to disable
the control download. Or you can lower the IE security level. See Figure 4-3.
or not after you logged in for one minute. Please click OK button, system can
Figure 4-3
After you logged in, you can see the main window. See Figure 4-4.
12
Figure 4-4
Please refer to the Web Operation Manual included in the resource CD for detailed operation
instruction.
13
5 FAQ
Bug
I can not boot up
the device.
SD card hot swap Before draw out SD card, please stop record or snapshot first and
SD card write
times
I can not use the
disk as the storage
media.
Recommended SD
card brand
I can not use PIR
function.
Please click RESET button for at least five seconds to restore
factory default setup.
then wait for at least 15 seconds to remove the SD card. All the
operations before is to maintain data integrity. Otherwise you can
lose all the data in the SD card!
Do not set the SD card as the storage media to storage the
schedule record file. It may damage the SD card duration.
When disk information is shown as hibernation or capacity is 0,
please format it first (Via Web).
Usually we recommend the 4GB (or higher) or industry-level high
speed card in case the slow speed results in data loss.
There are heating sources around the device environment. It may
result in false alarm.
The detect object is too long. The PIR sensitivity becomes lower
greatly when the distance is more than 6m.
I can not upgrade
the device via
network.
I can not login the
client-end or the
WEB.
I can not play the
download file.
To guarantee
setup update
When network upgrade operation failed, you can use port 3800 to
continue upgrade.
zFor Windows OS 98 or Windows ME user, if you can not install
the client-end or can not view after the installation. We
recommend the win2000sp4 OS or install the client-end of the
low version.
z The Active X control is blocked.
z The display card version shall be dx8.1 or higher.
z Network connection error occurred.
z Invalid network setup.
z Invalid user name or password.
z There is no player.
z There is no DX8.1 or higher.
z For the MEDIA PLAYER, there shall be Div X503Bundle.exe
plugin if you play the .AVI file.
zFor Windows XP user, you need to install the plugin
DivX503Bundle.exe and ffdsho-2004 1012.exe.
After you modified the important setup, please reboot the device via
the software to make sure the setup has been updated to the
storage medium.
14
Bug
Power adapter zThe general power adapter can work ranging from 0℃ to 40 ℃.
The device may result in unstable power supply when the
temperature exceeds the working temperature.
zPlease replace an industry-level power adapter if you are using
in the harsh environments.
15
Appendix Toxic or Hazardous Materials or Elements
Component
Name
Circuit Board
Component
Device Case
Wire and Cable
Packing
Components
Accessories ○ ○ ○ ○ ○ ○
O: Indicates that the concentration of the hazardous substance in all homogeneous materials in the
parts is below the relevant threshold of the SJ/T11363-2006 standard.
X: Indicates that the concentration of the hazardous substance of at least one of all homogeneous
materials in the parts is above the relevant threshold of the SJ/T11363-2006 standard. During the
environmental-friendly use period (EFUP) period, the toxic or hazardous substance or elements
contained in products will not leak or mutate so that the use of these (substances or elements) will not
result in any severe environmental pollution, any bodily injury or damage to any assets. The consumer
is not authorized to process such kind of substances or elements, please return to the corresponding
local authorities to process according to your local government statutes.
Note:
Pb Hg Cd Cr VI PBB PBDE
○ ○ ○ ○ ○ ○
○
○
○ ○ ○ ○ ○ ○
Toxic or Hazardous Materials or Elements
○ ○ ○ ○ ○
○ ○ ○ ○ ○
z This quick start guide is for reference only. Slight difference may be found in user interface.
z All the designs and software here are subject to change without prior written notice.
z All trademarks and registered trademarks mentioned are the properties of their respective
owners.
z If there is any uncertainty or controversy, please refer to the final explanation of us.
z Please visit our website or contact your local service engineer for more information.
16
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.