Zeutschel OMNISCAN 5000 User Manual

OMNISCAN 5000
TS-194 / 05.01
1
TABLE OF CONTENTS
TS-194/05.01
Chapter 1: Introduction page 2
Chapter 2: General description page 3
Chapter 3: Safety instructions page 4
Chapter 4: Installation page 5
Chapter 5: Operation page 9
Chapter 6: Maintenance page 11
2
Introduction: OMNISCAN 5000 - The Scanner for Large Documents
Fast high-performance scanning of books and large documents 256 grey scales and automatic image correction of the book curve
Until today, scanning or copying of large books or documents has been cumbersome, time-consuming and inaccurate. With state-of-the-art scan technology ZEUTSCHEL now provides a high performance large format scanning system OMNISCAN 5000 that will efficiently handle books and large documents with high resolution accuracy and reliability. It will reduce imaging time and labor cost. Simply place a book or a newspaper volume "face up" on the scanner's book cradle or table and you will digitize an image with all details in seconds. The built-in scan-area projection makes positioning very easy. The scan head captures the original "from the top". The connection to your document management systems is granted via an interface SCSI-2, TWAIN or ISIS. A laser-printer can be connected directly to the scanner for fast printing.
Now it is convenient and easy to digitize books: well-designed ZEUTSCHEL book cradles guarantee that the book bindings are not damaged. Also, there is no shadow area at the book gutter and with the electronic image correction of the book curve the script will appear without distortion. The result is high productivity and preservation of books.
The quality of digital images depends on the quality of the optical lens, the built-in scanning technology and the pre-cision of the mechanical/electronic components. The OMNISCAN 5000 scanner head was designed with a high-resolution lens, a precision mechanism to drive the high-performance CCD scan line, a 256 grey-scales feature and an optional electronic image correction of the book curve to guarantee superior scanning results. This means sharp and crisp images even from poor originals with low contrast, very fine lines or variable background density. Each captured image can then be processed with a powerful image enhancement software (optional: contrast enhancement, rotation, de-scew, de-speckle, cut/mask, crop, etc.) Thus, poor originals can be improved to good digital images and hard copies, and the storage space will be reduced considerably at the same time.
3
General description:
Description: High-Performance "Top light" Scanning System for books,
newspapers and large format documents (maps, drawings,
posters). Size of Originals: Max. A1/D-size (841 x 594 mm), books up to 500 mm thick. Scan Head: High-resolution CCD line sensor, precision scan lens. field of
depth approx. 50 mm / 2 inches. Electronically controlled focusing, 256
greyscales, scan area display, electronic image correction of the
book curve (optional). Exposure Control: Automatic control, manual threshold overrun. Operation: Simple function keys control for all scanning functions.
Foot switch for scan exposure (optional). Max. Resolution: CCD-line with 5150 pixel. Referring to original A3 (B) and A4 (A)
sizes: 400 dpi; A2 (C) size: 300 dpi; A1 (D) size: 200 dpi (optional A3/A4: 600dpi, A2: 400dpi, A1: 300dpi).
Scanning Speed: Approx. 3 sec. Output Format: Bitonal black and white/16/256-grey scales. Scanner Interface: SCSI-2 interface (optional TWAIN,ISIS). Image Output all major compression formats such as TIFF G3/4, JPEG, etc. Server-PC: recommended specification: Pentium, PCI-BUS, 128 MB RAM,
min. 2 GB hard disk, WIN NT (Server PC optional). Application Software: Optional application software and connection to document
management systems. Image Enhancement Optional, e.g. contrast enhancement, rotation,
Software: de-speckle, de-scew, crop, mask, etc. Book Cradles: Optional, ZEUTSCHEL models OT 180, OT 180 S or OT 90 Power Requirements: 230 V, 50/60 Hz. 400W. Other voltages on request Dimensions: Scanner: 1600 x 900 mm
Height with book cradle: 2100 mm Accessories: Document management software, image enhancement software,
laser-printer Technical specifications subject to change.
4
Safety instructions:
The scanner must only be operated with a single-phasing power supply of 230 V/50 Hz with separate protective conductor. Before operation the power supply must be checked by an authorised service engineer.
If the local power supply does not meet the above mentioned requirements, please contact the manufacturer who will check if the scanner system can be operated under the existing power supply conditions.
The power socket should be installed near the camera system and should be always accessible.
It is not allowed to open the scanner system, as the system is still live even if the mains switch is turned off.
After the scanner is switched on, the following functions will be automatically executed: Automatic initialisation of the scanner head Top light is automatically switched on.
The following works must be executed by service engineers only:
1. Exchange of lamps/bulbs
2. Exchange of camera tables, especially with book cradles
3. Interferences in control system, power supply It is necessary to study carefully the operator's manual before operating the scanner
system.
5
Installation:
OS 5000 base unit- and stand unit version Unpacking
- carefully unpack the the box consisting of:
- scanner base unit including power supply unit
- top light lamp set, each one for left and right side with power cable 220V
- scanner head with built-in SCSI-interface pcb
- cable, scan head - power supply unit
- SCSI - cable, scan head - server pc (optional)
- SCSI-interface pcb (ADAPTEC, optional)
- OMNISCAN 8.0 scanner software with DONGLE (optional)
- OMNISCAN COPYSCAN software with DONGLE (optional)
Installation of the OS 5000
Install the OS 5000 base unit only on a sturdy, non vibrating table resp. one of the ZEUTSCHEL document tables (OT 180, etc.) for best quality results. The OS 5000 SU is a stand alone version and has to be installed directly on an even non-vibrating floor. The document tables can be easily rolled-in and -out.
Fix the top light lamp set for the left and right side. Finaly install the scanner head at the scanner head rest of the column.
Attention! Please take of first the transport security set inside the scan head. Please check with the help of a precision water level that the scan head is absolutely
parallel installed to the book cradle and that also the scanner column is absolutely vertical installed.
Now you can connect the power cable from the scan head to the power supply unit which is fixed at the rear side of the column. Plug in the power cable of each lamp set and finally install the SCSI- cable "scan head - server pc". Before you switch on the power please re-check the correct installation.
Lamp adjustment
The lamp sets have to be installed in an angle position to achieve an even illumination on top of the book cradle. For the pre-adjustment you can use a luxmeter, however final adjustments have to be done by testing. Please take care that there is no lamp reflection in the document scan-area. It is recommended to adjust the lamp arms for the maximung scan area DIN A1 (D-size). Smaller documents can be scanned with the same lamp position, however for thick books you can achieve better results espescially of the book gatter by turning the lamps to a more vertical position.
6
Installation of the OMNISCAN 8.x scanner software with DONGLE (optional)
please see seperate instructions TS-0306
Installation of the OMNISCAN COPYSCAN software with DONGLE (optional)
Install the optional SCSI-interface pcb ADAPTEC into the server-pc (only if not already pre-installed).
Switch-on the scanner OS 5000 COPYSCAN Switch-on the server-pc, while booting the OS 5000 has to identify itself at ID 5 with the
name " ZEUTSCH. OMNISCAN 5000". Now install the COPYSCAN software. Please load the first disk in the disk drive "A" and select run a: setup. Install the DONGLE onto the printer socket at the server-pc and laod the dongle driver
disk. Select run a: HLDRV32.exe After a succesful installation start the COPYSCAN-software and release the first scan.
For correct document positioning and focus adjustment we refer to the operation instructions.
In case the fault message "cannot load WINASPI" appears you have to install the software "Adaptec EZ-SCSI v.4.01" too and to restart the COPYSCAN-software.
7
OMNISCAN 5000
(1) - power supply and control unit with ON/OFF-switch (2) - server-pc (3) - scan head (4) - top light, left side (5) - top light, right side (6) - push button - camera head up (7) - push button - camera head down (8) - scanner lens with scale for focus adjustment (9) - scanner column with scale for height position
8
Operation Instructions:
Start of the scanner:
- switch on the the main power switch of the scanner (1)
- switch on the server-pc (2)
- select scanning-software OMNISCAN 8.x. (for details please see separate operation manual for scan-software OMNISCAN 8.x)
- all major scanning functions can be released with the function keys F2 to F11, the scan exposure also can be released via the optional foot pedal.
Document positioning and scaling
- the documents can be easily positioned "face-up" on the document table.
- Bound documents and books are recommended to be scanned with the ZEUTSCHEL book cradle OT 180/OT 180S/OT 180H or OT 90. Sheets and thin documents can be scanned also with ZEUTSCHEL top light table AT 1 on top of the plate.
For detailed instructions we refer to the operation manual of each document table.
- the scan area can be increased by moving the scan head up. At the same time the scan resolution will be reduced. To move the scan head up please press the push button (6) at the camera base unit.
- the scan area can be reduced by moving the scan head down. At the same time the scan resolution will be increased. To move the scan head down please press the push button (7) at the camera base unit.
- for focusing the lens scale always have to be adjusted to the same value as the scan head height value, which is indicated at the scanner base column
The OS 5000 can be used in 2 different operation methods.
1. scanning all kind of documents with 400, 300 resp.200 dpi resolution.
max. scan area 400 dpi: DIN A3 (B-size) max. scan area 300 dpi: DIN A2 (C-size) max. scan area 200 dpi: DIN A1 (D-size)
Move the scan head in the height to position A3, A2 resp. A1 by pressing the push buttons at the right side of the camera base. and the lens scale to A3, A2 resp. A1 as well.
9
You can now scan all documents up to size DIN A3 with 400 dpi, up to size DIN A2 (C­size) with 300 dpi resolution.resp. up to size DIN A1 (D-size) with 200 dpi resolution.
Documents smaller than the adjusted max. document size can be easily masked with the OS5.x-software (see separate operation manual OS 5.x).
2. Scanning documents with maximum resolution i.e. up to DIN A3 with 400 dpi, DIN A2 with 300 dpi, resp. DIN A1 with 200 dpi.
For scanning documents up to size DIN A3 (B-size) position the scan head to the height position "A3" and turn the lens scale to position "A3" as well.
The scan head position can be easily adjusted in the height by push button control, which are fixed at the right hand side of the scanner base unit.
You can now scan the document with the maximum resolution of 400 dpi. Documents of not standard DIN-sizes can be can be scanned with maximum resolution
for each document by stepless up or down-movement of the scan head. For focusing please assure that the selected scale values at the lens and at the column
are always identical.
10
Maintenance:
The OMNISCAN 5000 scanner system is built very sturdy, but as every technical product, also the OMNISCAN 5000 requires care and regular maintenance for reliable operation.
The following maintenance is recommended:
- regular dust cleaning For dust cleaning it is recommended to use a soft leather or glass cleanser.
Attention! Cleaning of optical parts should only by handled by trained service engineers and onyl with a soft, fine brush. Never use any solvents or liquids on the surface of optical parts.
NOTE:
In case of problems, please contact your ZEUTSCHEL-dealer or the ZEUTSCHEL service department for repair.
Manufacturer: ZEUTSCHEL GMBH
Heerweg 2 D-72070 Tübingen Germany
Tel: - 49-7071 - 97060 Fax: - 49-7071 - 970644
Loading...