9.8V LOW POWER
PRECISION REFERENCE SOURCE
ISSUE 1 - OCTOBER 1995
ZRT100
DEVICE DESCRIPTION
The ZRT100 is a monolithic integrated circuit
providing a precise stable reference voltage
of 9.8V at 500µA.
The circuit features a knee current of 150µA
and operation over a wide range of
temperatures and currents.
The ZRT100 is available in a 3-pin metal can
package for through hole applications as
well as SOT223 and SO8 packages for
surface mount applications. Each package
option offers a trim facility whereby the
output voltage can be adjusted as shown in
Fig.1. This facility is used when
compensating for system errors or setting
the reference output to a particular value.
When the trim facility is not used, the pin
should be left open circuit.
SCHEMATIC DIAGRAM
R
CC
V
R
V
FEATURES
Trimmable output
•
Excellent temperature stability
•
Low output noise figure
•
Available in two temperature ranges
•
1 and 2% initial voltage tolerance
•
versions available
No external stabilising capacitor
•
required in most cases
Low slope resistance
•
TO18 package
•
SOT223 and SO8 small outline
•
packages
R=VCC-V
G
Figure 1:
This circuit will allow the reference to be
trimmed over a wide range. The device is
specified over a 65% trim range.
R
R
I
nd
RT=100k
(Optional trim facility)
nd
G
4-295
ZRT100
ABSOLUTE MAXIMUM RATING
Reverse Current 30mA ø
Operating Temperature
A grade -55°C to 125°C
C grade 0°C to 70°C
Storage Temperature
TO18 -55 °C to 175 °C
SO8, SOT223 -55 °C to 125 °C
TEMPERATURE DEPENDENT ELECTRICAL CHARACTERISTICS
SYMBOL PARAMETER
DV
R
Output voltage
change over relevant
temperature range
(See note (a))
T
CVR
Output voltage
temperature
coefficient (See note
(b))
INITIAL
VOLTAGE
TOLERANCE
%
1 & 2 27.0 90.0 10.8 34.4 mV
1 & 2 15.0 50.0 15.0 50.0 ppm/°C
ELECTRICAL CHARACTERISTICS
( at T
SYMBOL PARAMETER
V
DV
T
I
R
t
on
t
off
e
R
=25°C and Trim pin o/c unless otherwise stated)
amb
R
Output voltage
1% tolerance (A1,C1)
2% tolerance (C2)
TRIM
Output voltage adjustment
range
CDVTRIM
Change in TCVR with output
adjustment
Operating current range 0.15 30 mA See note (c)
Turn-on time
Turn-off time
np-p
Output voltage noise (over
the range 0.1 to 10Hz)
S
Slope resistance 1.8 4.0
Power Dissipation (T
TO18 300mW
SO8 625mW
SOT223 2W
ø Above 25°C this figure should be linearly
derated to 6mA at 125°C
GRADE A
-55°C TO 125°C
0°C TO 70°C
TYP MAX TYP MAX
MIN. TYP.
9.70
9.60
9.80
9.80
MAX. UNITS
9.90
V
10.00
65%
5.0 ppm/°C/%
400
µsR
0.3
50
µV
Ω
=25°C)
amb
GRADE C
UNITS
COMMENTS
I
=500µA
R
=100kΩ
R
T
=1kΩ
L
Peak to peak
measurement
IR =
0.5mA to 5mA
See note (d)
4-296