Zeroplus LAP-C, LAP-D User Manual

Smart+ User’s Manual V1.04.04
2 FM07I4A
1 Features of Zeroplus Logic Analyzer ........................................................................................................................... 4
1.1 Welcome choosing the product of Zeroplus Technology ..................................................................................... 5
1.2 Package Contents ................................................................................................................................................ 5
1.3 Introduction ......................................................................................................................................................... 8
1.4 Specifications .................................................................................................................................................... 11
1.5 Special Functions and Patents Introduction ....................................................................................................... 15
1.5.1 Bus Wizard ........................................................................................................................................................ 15
1.5.2 Auto Run(only for D Series) ............................................................................................................................. 15
1.5.3 Image Encode (Patent pending) ......................................................................................................................... 15
1.5.4 Real-time Monitoring of Level/Frequency ........................................................................................................ 15
1.5.5 Multi-level Hardware Trigger (only for D Series) ............................................................................................. 15
1.5.6 Patents Introduction .......................................................................................................................................... 15
1.6 System Requirements ........................................................................................................................................ 17
1.7 Device Maintenance and Safety ........................................................................................................................ 18
2 Installation ................................................................................................................................................................. 20
2.1 Software Installation ......................................................................................................................................... 21
2.2 Hardware Installation ........................................................................................................................................ 23
2.3 Tips and Advice ................................................................................................................................................. 24
3 Users Interface ........................................................................................................................................................... 25
3.1 User Interface .................................................................................................................................................... 26
3.2 Main Menu ........................................................................................................................................................ 29
3.3 Right Key Menu ................................................................................................................................ ................ 36
3.4 Common Toolbar............................................................................................................................................... 39
4 Software Introduction ................................................................................................................................................ 41
4.1 Save Setup ......................................................................................................................................................... 42
4.2 Export Setup ...................................................................................................................................................... 43
4.3 Screen Capture .................................................................................................................................................. 47
4.4 Print Setup ......................................................................................................................................................... 48
4.5 Options .............................................................................................................................................................. 49
4.6 Acquisition Setup .............................................................................................................................................. 61
4.7 Trigger and Find Setup ...................................................................................................................................... 62
4.8 External Trigger (only supported by LAP-D Series) ......................................................................................... 70
4.9 Signal Filter Setup(not supported by LAP-D Series) ......................................................................................... 70
4.10 Add Channel/Bus Setup .................................................................................................................................... 71
4.11 Connect Multiple smart+ ................................................................................................................................... 84
Smart+ User’s Manual V1.04.04
3 FM07I4A
4.12 Connect to DSO ................................................................................................................................................ 86
4.13 Noise Filter Setup .............................................................................................................................................. 90
4.14 Files Comparison .............................................................................................................................................. 91
4.15 Math Operation ................................................................................................................................................. 94
4.16 Go To…............................................................................................................................................................. 96
4.17 Specific Bus Data Display ................................................................................................................................. 99
4.18 Signal Activity................................................................................................................................................. 100
4.19 Navigator......................................................................................................................................................... 102
4.20 Packet List ....................................................................................................................................................... 103
4.21 Statistic ............................................................................................................................................................ 107
4.22 Memory View.................................................................................................................................................. 110
4.23 Trace Format ................................................................................................................................................... 113
4.24 Protocol Decoder ............................................................................................................................................. 114
5 FAQ ......................................................................................................................................................................... 117
5.1 Hardware ......................................................................................................................................................... 118
5.2 Software .......................................................................................................................................................... 119
5.3 Registration ..................................................................................................................................................... 121
5.4 Technical Information ..................................................................................................................................... 122
5.5 Others .............................................................................................................................................................. 124
6 Troubleshooting ....................................................................................................................................................... 125
7 Appendix ................................................................................................................................................................. 126
7.1 Hot Keys ......................................................................................................................................................... 127
7.2 Contact Us ....................................................................................................................................................... 129
Smart+ User’s Manual V1.04.04
4 FM07I4A
1 Features of Zeroplus Logic Analyzer
1.1 Welcome choosing the product of Zeroplus Technology
1.2 Package Contents
1.3 Introduction
1.4 Specifications
1.5 Special Functions and Patents Introduction
1.6 System Requirements
1.7 Device Maintenance and Safety
Smart+ User’s Manual V1.04.04
5 FM07I4A
1.1 Welcome choosing the product of Zeroplus Technology
Zeroplus Technology, though a new company in instrument industry, spares no effort to develop new technology, apply for patents and control the quality. The products of Zeroplus Technology are well acknowledged in the industry, so we assure that your choice cant be wrong.
Zeroplus Logic Analyzer has four types: LAP-A, LAP-B, LAP-C and LAP-D. With advanced technology, these products will help you to detect and analyze problems at the highest speed, and measure more information. It is a necessary tool for electrical technicians, electrical testers, students of electrical motor and personal studios. This Smart+ software supports LAP-C and LAP-D series.
Note: No further notice to you if any modification occurs. Please refer to the software to avoid any inconformity.
1.2 Package Contents
Verify that the following accessories are along with your product or not after open its package.
Models
LAP-C(16032)
LAP-C(16064)
LAP-C(16128)
LAP-C(162000)
LAP-C(32128)
USB Cable
1 1 1 1 1
Testing Cable
8Pin*2 2Pin*1 1Pin*1
8Pin*2 2Pin*1 1Pin*1
8Pin*2 2Pin*1 1Pin*1
8Pin*2 2Pin*1 1Pin*1
16Pin*1
8Pin*2 2Pin*1 1Pin*1
Probe 2 20
20
20
36
Driver CD
1 1 1 1 1
Quick Start Guide
0 1 1 1 1
Models
LAP-C(321000)
LAP-C(322000)
LAP-C(16128+)
LAP-C(162000+)
USB Cable 1 1 1 1
Testing Cable
16Pin*1
8Pin*2 2Pin*1 1Pin*1
16Pin*1
8Pin*2 2Pin*1 1Pin*1
8Pin*2 2Pin*1 1Pin*1
8Pin*2 2Pin*1 1Pin*1
Probe
36
36
20
20
Driver CD 1 1 1 1
Quick Start Guide
1 1 1
1
Smart+ User’s Manual V1.04.04
6 FM07I4A
Below table shows the package contents of LAP-C Series products.
Fig 1-1: Logic Analyzer
16 Pin x 1
8 Pin x 2
Fig 1-2: Testing Cable
Fig 1-3: Probe (differentiated by the model)
Fig 1-4USB Cable
Fig 1-5: Quick Start Guide
Fig 1-6: Driver CD
Fig 1-7: 1-Pin External Clock Cable(White)
Fig 1-8: 2-Pin Ground Cable (Black)
Models
LAP-D(32064M)
LAP-D(32512M)
USB Cable
1
1
Testing Cable
16Pin*1
8Pin*2 2Pin*1 1Pin*1
16Pin*1
8Pin*2 2Pin*1 1Pin*1
Probe
36
36
Driver CD
1
1
Quick Start Guide
1
1
Smart+ User’s Manual V1.04.04
7 FM07I4A
Below table shows the package contents of LAP-D Series products.
Fig 1-9: Logic Analyzer
Fig 1-10: Testing Cable
Fig 1-11: Probe
Fig 1-12USB Cable
Fig 1-13: Quick Start Guide
Fig 1-14: Driver CD
Fig 1-15: BNC Cable
Fig 1-16: AC Power Line
Fig 1-17: Carry-on Bag
Fig 1-18: DC Transformer
*If any accessory is missing or damaged, please contact the distributor immediately.
Smart+ User’s Manual V1.04.04
8 FM07I4A
1.3 Introduction
Description for LAP-C Series Models:
The USB connection supply the power.
Smart+ User’s Manual V1.04.04
9 FM07I4A
Description for LAP-D Series Models:
Front view of LAP-D ports. (Refer to the table 1-1 for the detailed port names)
Table 1-1: List of available channels.
Back view of LAP-D ports. (Refer to the table 1-2 for the detailed port names)
Models
LAP-D (32064M)/
LAP-D(32512M)
Port A
( A0~A7) (A8~A15)
V
Port B
( B0~B7) (B8~B15)
V
3.3V
3.3V Voltage Outputting
GND
V
Smart+ User’s Manual V1.04.04
10 FM07I4A
Table 1-2: List of special function pins
Trigger
Out
Trigger Out
Pins
When the condition is met (such as the trigger occurs, start capturing, stop capturing), the Trigger Out will send out a 3.3V [Rising Edge/Falling Edge/Status] signal.
External
Port
Expansion
Ports
Pin NO.
Function
Description
Pin NO.
Function
Description
1
3.3V
2
Ground
3
Trigger
Status
4
5
N/A
6
7
External Clock In
8
9
N/A
10
11
External
Trigger In
12 13
N/A
14
15
N/A
16
17
N/A
18
19
N/A
20
The Trigger Out is designed as the BNC connector to connect with other devices (such as oscilloscope).
LAP-D and BNC Cable
Smart+ User’s Manual V1.04.04
11 FM07I4A
1.4 Specifications
Model
LAP-C(162000)
LAP-C(16128+)
LAP-C(162000+)
Operating System
Windows XPVistaWindows 7
Interface
USB 2.0(1.1)
Power Supply
USB
Sampling
Frequency
Internal(Clock)
(Asynchronous)
100Hz~200MHz
External(Status) (Asynchronous)
100MHz
Model
LAP-C(16032)
LAP-C(16064)
LAP-C(16128)
Operating System
Windows XPVistaWindows 7
Interface
USB 2.0(1.1)
Power Supply
USB
Sampling
Frequency
Internal(Clock)
(Asynchronous)
100Hz~100MHz
100Hz~100MHz
100Hz~200MHz
External(Status) (Asynchronous)
75MHz
75MHz
100MHz
Bandwidth
75MHz
75MHz
75MHz
Memory
Memory
512Kbits
1Mbits
4Mbits
Memory
(Per Channel)
32 K bits(Max
8Mbits for
Compression)
64 K bits(Max
16Mbits for
Compression)
128 K bits (Max
32Mbits for
Compression)
Trigger
Trigger Channel
16CH
Trigger Condition
Pattern/Edge
Pre-Trigger/ Post-Trigger
Yes
Pulse Width
Trigger
Free
Trigger Level
1 Level
Trigger Count
1~65536
Threshold
Voltage
Working Voltage
-6V~+6V
Accuracy
±0.1V
Software
Functions
Operating
Interface
Language
Chinese(Si)/ Chinese(Tr)/ English
Time Base Range
5ps~10Ms
Waveform
Vertical Scaling
1~5.5
Signal Filter and
Delay
Yes
Compression
Max 8Mbits
Max 16Mbits
Max 32Mbits
Waveform
Width Display
Yes
Trigger Page
8192 Pages
Double Mode
No
Yes
Trigger Mark
Option
Latch Function
Option
Data Contrast
Option
Multi-stacked
Function
No
Protocol Analyzer
Trigger
Option
Safety Certification
FCC/CE/WEEE/RoHS
Smart+ User’s Manual V1.04.04
12 FM07I4A
Bandwidth
75MHz
Memory
Memory
64Mbits
4Mbits
64Mbits
Memory
(Per Channel)
2Mbits(Max
512Mbits for
Compression)
128Kbits(Max
32Mbits for
Compression)
2Mbits(Max 512Mbits for
Compression)
Trigger
Trigger Channel
16CH
Trigger Condition
Pattern/Edge
Pre-Trigger/ Post-Trigger
Yes
Pulse Width
Trigger
Free
Trigger Level
1 Level
Trigger Count
1~65536
Threshold
Voltage
Working Voltage
-6V~+6V
Accuracy
±0.1V
Software
Functions
Operating
Interface
Language
Chinese(Si)/ Chinese(Tr)/ English
Time Base Range
5ps~10Ms
Waveform
Vertical Scaling
1~5.5
Signal Filter and
Delay
Yes
Compression
Max 512Mbits
Max 32Mbits
Max 512Mbits
Waveform
Width Display
Yes
Trigger Page
8192 Pages
Double Mode
Yes
Trigger Mark
Yes
Latch Function
Yes
Data Contrast
Yes
Multi-stacked
Function
No
Protocol
Analyzer
Trigger
Option
Free
Safety Certification
FCC/CE/WEEE/RoHS
Model
LAP-C(32128)
LAP-C(321000)
LAP-C(322000)
Operating System
Windows XPVistaWindows 7
Interface
USB 2.0(1.1)
Power Supply
USB
Sampling
Frequency
Internal(Clock)
(Asynchronous)
100Hz~200MHz
External(Status) (Asynchronous)
100MHz
Bandwidth
75MHz
Memory
Memory
4Mbits
32Mbits
64Mbits
Memory
(Per Channel)
128 Kbits(Max
32Mbits for
Compression)
1Mbits(Max 255Mbits
for Compression)
2Mbits(Max 512Mbits for
Compression)
Trigger
Trigger Channel
32CH
Trigger Condition
Pattern/Edge
Smart+ User’s Manual V1.04.04
13 FM07I4A
Pre-Trigger/ Post-Trigger
Yes
Pulse Width
Trigger
Free
Trigger Level
1 Level
Trigger Count
1~65536
Threshold
Voltage
Working Voltage
-6V~+6V
Accuracy
±0.1V
Software
Functions
Operating
Interface
Language
Chinese(Si)/ Chinese(Tr)/ English
Time Base Range
5ps~10Ms
Waveform
Vertical Scaling
1~5.5
Signal Filter and
Delay
Yes
Compression
Max 32Mbits
Max 255Mbits
Max 512Mbits
Waveform
Width Display
Yes
Trigger Page
8192 Pages
Double Mode
Yes
Trigger Mark
Option
Yes
Latch Function
Option
Yes
Data Contrast
Option
Yes
Multi-stacked
Function
Yes
Protocol
Analyzer
Trigger
Option
Free
Safety Certification
FCC/CE/WEEE/RoHS
Model
LAP-D(32512M)
Channel Mode
32CH
16CH
8CH
Interface
USB 2.0 (1.1)
Operating System
Windows XPVista Windows 7
Measurement Channel
32CH
16CH
8CH
Input Bandwidth
400MHz
Trigger Voltage Range
-5V~+5V
Trigger Voltage
Accuracy
0.1V
Memory
16Gbits
Memory Per Channel
512 Mbits
1Gbits
2Gbits
Internal (Clock)
(Asynchronous)
400MHz
800MHz
1.6GHz
External (Clock)
(Synchronous)
200MHz
Trigger Condition
Pattern / Edge / Pulse Width
External Trigger
Input
Rising Edge/Falling Edge/Either Edge
Output
[When condition is met/Start/Stop]Output[Rising
Edge/Falling Edge/Status]
Trigger Delay
Yes
Trigger Level
256 Level
Trigger Count
1-65535
Smart+ User’s Manual V1.04.04
14 FM07I4A
Trigger Interval
1s30d
Bus Decoding
Yes
Working Voltage
DC 7.5V
Max. Input Voltage
±DC 30V
Model Size
(Length*Width*Height)
251mm x 182mm x 40mm
Safety Certification
FCC / CE
Model
LAP-D(32064M)
Channel Mode
32CH
16CH
8CH
Interface
USB 2.0 (1.1)
Operating System
Windows XPVista Windows 7
Measurement Channel
32CH
16CH
8CH
Input Bandwidth
400MHz
Trigger Voltage Range
-5V~+5V
Trigger Voltage
Accuracy
0.1V
Memory
2Gbits
Memory Per Channel
64 Mbits
128 Mbits
256 Mbits
Internal (Clock)
(Asynchronous)
400MHz
800MHz
1.6GHz
External (Clock)
(Synchronous)
200MHz
Trigger Condition
Pattern / Edge / Pulse Width
External Trigger
Input
Rising Edge/Falling Edge/Either Edge
Output
[When condition is met/Start/Stop]Output[Rising
Edge/Falling Edge/Status]
Trigger Delay
Yes
Trigger Level
256 Level
Trigger Count
1-65535
Trigger Interval
1s30d
Bus Decoding
Yes
Working Voltage
DC 7.5V
Max. Input Voltage
±DC 30V
Model Size
(Length*Width*Height)
251mm x 182mm x 40mm
Safety Certification
FCC / CE
Smart+ User’s Manual V1.04.04
15 FM07I4A
1.5 Special Functions and Patents Introduction
1.5.1 Bus Wizard
With the intelligent classification function of Smart+ software, users can do the Bus decoding settings conveniently and quickly.
1.5.2 Auto Run(only for D Series)
The Smart+ software can auto-scan the signal and decide the best sampling frequency for capturing, so as to make full use of the best measurement time length of LA. Users no need to select the sampling frequency by hand.
1.5.3 Image Encode (Patent pending)
CMOS: By the Image Encode function, users can restore the video digital signal that captured by the Smart+ to pictures. 7-segment Display: After capture the signal of 7-segment display, users can quickly check its display status by the Image Encode function. LCD Display(1602/12864): By the Image Encode function, users can clearly see the complicated character code table, and better handle the LCD display status.
1.5.4 Real-time Monitoring of Level/Frequency
The Real-time Monitoring of Level/Frequency function can help engineers to monitor the signal frequency and level status, so the Logic Analyzer is not just a Logic Analyzer, it can be frequency counter and logic pen.
1.5.5 Multi-level Hardware Trigger (only for D Series)
With the 256-level hardware trigger function, users can freely set the hardware trigger for the serial signal. According to the signal change and along with LAP-D multi-level trigger function, this function can set hardware trigger for many serial signals, so more waveform can be captured.
1.5.6 Patents Introduction
·Data Compression (Patent US7.392,434B2) Zeroplus Logic Analyzer owns the patent technology of waveform compression. This technology can instantly compress the signal without damaged, so the memory can store more data with higher resolution. The compression rate can reach up to 255, that means if the memory is 128K, then as much as 32Mbits(128K*255) data can be captured in each channel. The compression rate changes in accordance with the data content.
·Waveform Data Display (Patent Taiwan I267646) Zeroplus Logic Analyzer can display the waveform time. Users can decide whether to display the time of waveform width(between two rising edges or falling edges) or not in the waveform display window. There are three modes: Sampling Site Display, Time Display, Frequency Display.
·Filter Delay (Patent Taiwan I271532) Zeroplus Logic Analyzer owns the patent technology of waveform signal filter delay. Filter delay is to prolong or shorten the filtering effect. In other words, it can convert the set area of filter to the reverse area of filter, or shorten/ prolong the filter area, or shorten/prolong the filter reverse area.
·Data Contrast, Bus Packet List, Memory Analyzer (Patent Taiwan I224195) Data Contrast: Users can contrast the waveforms of two LA files (their environment parameters shall be the same); the software will mark their differences with orange wavy line, and display the contrast result in the Log window.
Smart+ User’s Manual V1.04.04
16 FM07I4A
Bus Packet List: The Smart+ software can display the packet status of various protocol analyzer through the bus decoding module. Users can use the Bus Packet List function to display huge packet data in a list, with which analyzing the relation between each packet becomes much easy. Memory Analyzer: Display the packet data that analyzed by the Smart+ bus decoding module in the memory map way which is common in memory. Take the EEPROM as an example, users can understand the read/write status of each address in the memory.
Volatile Memory Access (Patent Taiwan M398147)
It can increase the memory size and transmission speed effectively.
Smart+ User’s Manual V1.04.04
17 FM07I4A
1.6 System Requirements
Operating System Requirements:
Support
Non-support
Operating
System Name
Windows XP (Home, Professional Editions 32-Bit
version) Windows VISTA (32-bit and 64-bit version) Windows 7 (32-bit and 64-bit version)
Windows NT 4.0 (Workstation &
Server, Service Pack 6)
Windows Server 2003
Hardware System Requirements for LAP-C and LAP-D:
Hardware Name
Lowest Configuration
Recommended Configuration
CPU
1G MHz
2G MHz
Memory
256MB
2GB
Display Device
RAM shall be at least 256MB and the
resolution shall be at least 1024*768.
RAM shall be at least 1G and the
resolution shall be at least 1024*768.
Hard Disk
At least 50GB available space
USB
USB 2.0 supported
Smart+ User’s Manual V1.04.04
18 FM07I4A
1.7 Device Maintenance and Safety
Follow below instructions to operate and store the Logic Analyzer properly.
General Advice:
Cautions
Do not place heavy objects on the Zeroplus Logic
Analyzer.
Avoid direct impacts and rough handling. Protect the Logic Analyzer from static discharge. Do not disassemble the Zeroplus Logic Analyzer; this will
void the warranty and could affect its operation.
Cleaning
Use a soft, damp cloth with mild detergent to clean. Do not spray any liquid on the Zeroplus Logic Analyzer or
immerse it in any liquid.
Do not use harsh chemicals or cleaners containing
substances such as benzene, toluene, xylene or acetone.
Electrical Specifications(LAP-C Series):
Item
Minimum
Typical
Maximum
Working Voltage
DC 4.5 V
DC 5.0 V
DC 5.5 V
Current at Rest
200 mA
Current at Work
400 mA
Power at Rest
1 W
Power at Work
2W
Error in Phase Off
±1.5 ns
V
input
of Testing Channel
±DC 30 V
V
Reference
DC -6V
DC +6 V
Input Resistance
500K/10pF
Working Temperature
5°C 70°C
Storage Temperature
-40°C
80°C
Electrical Specifications(LAP-D Series):
Item
Minimum
Typical
Maximum
Working Voltage
DC 7.5V
Current at Rest
Current at Work
Power at Rest
Power at Work
Error in Phase Off
±1.5 ns
V
input
of Testing Channel
±DC 30 V
V
Reference
DC -5V
DC +5 V
Input Resistance
750KΩ/10pF
Working Temperature
5°C 70°C
Storage Temperature
-40°C
80°C
Smart+ User’s Manual V1.04.04
19 FM07I4A
Operating Environment:
WARNING
Avoid direct sunlight Use in a dust free, non-conductive environment (see Note) Relative Humidity: < 80% Altitude: < 2000m Temperature: 0 ~ 40 Degrees
As a Class A product, it may cause radio interference in a domestic environment.
Pollution refers to ‘solid, liquid or gas (ionized gas) which may cause reduction of dielectric strength or surface impedance’.
Pollution Level 1: No pollution or only dry, non-conductive pollution occurs. This pollution has no effect.
Pollution Level 2: Normally only non-conductive pollution occurs. But temporary conductivity caused by the occasional condensation must be kept in mind.
Pollution Level 3: Conductive pollution occurs or dry, non-conductive pollution caused by the condensation occurs. In such conditions, the equipment is normally protected against exposure to direct sunlight, precipitation and wind, but neither temperature nor humidity is controlled.
Note: EN 61010-1:2001 specifies the levels of pollution and their requirements. Logic Analyzer belongs to Level 2.
Storage
Environment
Relative Humidity: < 80% Temperature: 0 ~ 50 Degrees
Conclusion:
This section gives a basic description about the Logic Analyzer. Read the part of Device Maintenance and Safety carefully before do any further operation.
Smart+ User’s Manual V1.04.04
20 FM07I4A
2 Installation
2.1 Software Installation
2.2 Hardware Installation
2.3 Tips and Advice
Smart+ User’s Manual V1.04.04
21 FM07I4A
2.1 Software Installation
STEP 1. Close all programs firstly. STEP 2. Place the Zeroplus Smart + driver CD into the CD-ROM. If the CD can auto-play, click “Application Setup” firstly and then click “Driver Setup” to make sure the Logic Analyzer can work normally.
STEP 3. If the CD cant auto-play, click StartRun and input “D:\set.exe”(if the CD-ROM is D:\) in the input box, then click Next. Make sure the LA connects with the PC by USB before installing the software (The recommended screen resolution is 1024*768). STEP 4. After installation starts, please read the “LICENSE AGREENMENT” carefully. Click “I accept the terms in the license agreement” to continue; or click the other option to cancel.
Smart+ User’s Manual V1.04.04
22 FM07I4A
STEP 5. If users accept the agreement, click Next continuously if the options are no need to change(be default) , and click Finish to complete the installation. The Finish page reminds users to restart the computer now or later; recommend to select Yes, I want to restart my computer now.
STEP 6. Once the Logic Analyzer is power on, a tip of “Find a new hardware” will appear. Then the Smart+ driver will be installed automatically. After the driver installation finishes, the Smart+ is ready to work.
Smart+ User’s Manual V1.04.04
23 FM07I4A
2.2 Hardware Installation
Connect the B-type connector (of the attached USB connect line) with the B-type socket of Logic Analyzer and the A-type with the A-type socket of computer. Keep the power being on. LAP-C Series:
LAP-D Series:
Smart+ User’s Manual V1.04.04
24 FM07I4A
2.3 Tips and Advice
1. During testing, make sure that the internal sampling frequency of LA be at least four times higher than the frequency of device under test.
2. If the connector of testing cable does not work well with the pins of device under test, try to use the supplied probe.
Fig. 2-1: Probe Supplied by Zeroplus
3. How to use the probe:
Fig. 2-2
Fig. 2-3
Step 1: Insert the loose end of the
cable into the connect pin of probe. (Fig. 2-2).
Step 2: Compress the probe as shown
to reveal two metal prongs. Insert the metal prongs into the metal connector of device under test and release to let them to grip the metal connector. (Fig. 2-3).
4. If the internet is available, the Logic Analyzer will connect with the Zeroplus Server automatically and search for update.
5. Unwanted signals can be filtered by the Signal Filter or Signal Filter Delay function.
6. During long-time measuring, Compression function can increase the memory’s efficiency.
7. Trigger condition depends on the device under test. If trigger can’t be activated, try to widen the trigger conditions.
8. If the frequency of device under test is out of the range of internal sampling frequency of LA, use the external frequency as the external sampling frequency.
Smart+ User’s Manual V1.04.04
25 FM07I4A
3 Users Interface
3.1 User Interface
3.2 Main Menu
3.3 Right Key Menu
3.4 Common Tools
Smart+ User’s Manual V1.04.04
26 FM07I4A
3.1 User Interface
1. The Interface can be classified into the following sections: A. Menu Bar
All operations are included in the menu bar, including File(F), Acquisition(A), Hardware(H), Analysis(D), View(V) and Help(H).
B. Tool Bar
The tool bar consists of graphical icons of the most frequently used functions. Users can set or operate the Logic Analyzer more easily. The corresponding shortcut key information will appear when users move the cursor to one icon. For example, the shortcut key of New button is “Ctrl+N, so when users place the cursor on the icon, New(Ctrl+N) will appear.
C. File Bar
The File Bar consists of File Page, Memory Page and Show All. The File Page displays the new added files. File Page can be minimized, restored and closed. If the file is larger than 512K, it will be divided into pages of 512K automatically.
D. Information Bar The Information Bar displays the width information of waveform, such as: Sampling Site, Time, Frequency, T Bar, A
Smart+ User’s Manual V1.04.04
27 FM07I4A
Bar, B Bar and other Bar. See below details: Scale: Interval time width of each sampling site.
Total: Total time length of current data capturing. Display Pos: The middle position of display area. Display Range: The waveform time range of current waveform view area. A Pos: The position of A Bar. It also can be set as other Bar. B Pos: The position of B Bar. It also can be set as other Bar. A -T: The time difference between A Bar and T Bar. Click it to choose other options. B -T: The time difference between B Bar and T Bar. Click it to choose other options.
: Select one bar.
: Memory page in which the bar locates.
:Go to the selected bar.
: Place the selected bar in the middle of waveform view area.
E. Ruler: Time vector in the waveform view area. F. Channel Column: Edit channel names. G. Trigger Column: Set the signal trigger conditions fast and intuitively.
H. Filter Column: Set the signal filter conditions fast and intuitively. I. Waveform View Area: Display the waveform of current captured data. J. Status Area: Display the Logic Analyzer’s status and the function description.
2. Control Panel Description:
Zoom: It is used to adjust the scale by selecting value from the pull-down menu, inputting value by hand or clicking the
magnifier button. This function is disabled in the listing window.
RAM Size: It is used to adjust the RAM size for each channel; different model has different max. RAM size.
Internal Clock: Users can adjust the internal clock by selecting one value from the pulldown menu, inputting value by
hand, or dragging the pointer of knob. If the cursor is on the knob, users can roll the roller to adjust. Click the icon
Smart+ User’s Manual V1.04.04
28 FM07I4A
to switch to external clock.
External Clock: Users can input the value or drag the pointer of knob to adjust. If the cursor is on the knob, users can use the roller to adjust. The sampling signal can be set as Rising Edge, Falling Edge or Either Edge
(Either Edge is only suitable for D Series) by clicking the top-right icon.
Trigger Position: Users can drag the cursor or roll the roller to adjust. Composite Panel:
1. Basic tool: Normal and Hand Modes can be switched.
2. Waveform Display Mode: “ Hide Time of Waveform”, “ Frequency Display”, “ Sampling Site Display” and “ Time Display” can be switched.
3. Previous: Move the previous find condition to the central point.
4. Next: Move the next find condition to the central point. For sections 5, 6 and 7, please refer to the part of Acquisition(A) Menu.
Smart+ User’s Manual V1.04.04
29 FM07I4A
3.2 Main Menu
3.2.1 File(F) Menu
New: Create a new file; 12 files can be created at most(determined by the free disk space). Open: Open an exist file. The software supports formats of *.als, *.alc and *.lap; if opens *.als or *.alc file, it will
automatically convert them to *.lap file. For models in same series, high-level ones could open the files saved by low-level ones, for example: LAP-C(322000) model could open the file of LAP-C(32128) model.
Close: Close the current file. If the file has not been saved, the software will remind users to save. Save: Save the current file. If the file hasn’t ever been saved, it will be saved as a new file in the format of *.lap or
*.alc.
Save As: Save the current file as a new file in the format of *.lap or *.alc. Export: Export the Waveform, Packet List or Memory Analyzer. Screen Capture: Capture some area(including full screen) and save it as picture. It also provides functions of Note,
Select Line Color, Clipboard, MsPaint and file.
Print: Print all pages, pages in a range or the current page. Print Preview: Preview the file to be printed. Options: Users can set the environment, prompt, custom toolbar, color, waveform view area, shortcut key and save
setting as their needs.
Exit: Exit the main program. If there is any file not saved, the main program will remind users to save.
3.2.2 Acquisition(A)Menu
Single Capture: Capture signal one time according to the trigger conditions.
Smart+ User’s Manual V1.04.04
30 FM07I4A
Repetitive Capture: Capture signal continuously according to the trigger conditions until be stopped. Auto Capture: Judge the sampling frequency and the trigger level automatically, and display the captured data in the
best way.
Stop: Stop capturing. Acquisition Setup: Set the Clock(Internal Clock, External Clock, Frequency), the Continuous acquisition
signal(Interval Time, Stop Condition) and RAM size.
Trigger and Find: Set the condition of trigger and find. See the section “Trigger and Find ” for more details. External Trigger: Set the input/output of external trigger. This function is unavailable for LAP-C Series. Signal Filter Setup: Set the Channel Selection, Reserved Condition, Reserved Area and Filter Area. It is unavailable
for LAP-D Series.
Add Channel/Bus: Add Channel, Bus or Protocol Analyzer. See 4.9 for more details.
3.2.3 Hardware(H) Menu
LAP-C Series
LAP-D Series Normal Mode: It is the default Mode. Double Mode: In the Double Mode, the RAM size will be double of the highest RAM size. Take LAP-C(32128) as an
example, its highest RAM size is 128K; after the Double function is activated, the RAM size will be up to 256K. For models of 32 channels, channels 1-16 will use the RAM size of channels 17-32 to capture large data. Models of 16 channels have no such limitation. If users need more RAM size (larger than 128K) but the quantity of channels is less than 16, then they can activate the Double Mode, or set trigger page, or use higher level models. LAP-C(16064) and LAP-C(16032) models don’t support the Double Mode. Compression Mode: Compress the signal realtimely without data damaged. With compression technology, more sampling data can be stored in the limited RAM size, with higher resolution and not wasting RAM size. The compression rate of Zeroplus Logic Analyzer can be up to 255 times. That’s mean when the RAM size is 128K, each channel can store as much as 32 M bits(128K*255) data. The compression rate is subject to the data. Note: For models of 32 channels, after compression activated, the quantity of channels will be reduced to 24, that’s mean only channels 1-24(A0-C7) are available, channels 25-32(D0-D7) have no function. Compressed data is larger than uncompressed data. The compressed data will be decompressed after transmitted into the computer; its decompression time is determined by the computer operating rate. Models of 16 channels have no such limitation.