Your safety and the safety of others are very important.
We have provided many important safety messages in this manual for your appliance. Always read
and obey all safety messages.
This is the Safety Alert Symbol. This symbol alerts you to potential hazards that can cause severe
bodily injury or death. All safety messages will follow the Safety Alert Symbol and either the words
“DANGER” “WARNING” or “CAUTION”
VERONA
WALL
DANGER
Danger means that failure to heed this safety
statement may result in severe injury or death.
WARNING
Warning means that failure to heed this safety
statement may result in extensive product damage,
serious personal injury, or death.
CAUTION
4
Caution means that failure to heed this safety
statement may result in minor or moderate
personal injury, property or equipment damage.
Verona Use, Care, and Installation Guide
ZEPHYRONLINE.COM
General Safety
To reduce the risk of fire or electric shock, do not use this fan
Safety Information
READ AND SAVE THESE INSTRUCTIONS
WARNING
with any solid-state control device.
WARNING
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the
manufacturer.
b) Before servicing or cleaning unit, switch power o at service panel and lock the service
disconnecting means to prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to
the service panel.
CAUTION
For General Ventilating Use Only. Do Not Use To Exhaust
Hazardous Or Explosive Materials And Vapors. Take care
when using cleaning agents or detergents. Suitable for use in
household cooking area.
Verona Use, Care, and Installation Guide
5
CORE
Safety Information
VERONA
WALL
READ AND SAVE THESE INSTRUCTIONS
WARNING
WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy
spillovers that may ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when flambeing food. (i.e. Crepes Suzette,
Cherries Jubilee, Peppercorn Beef Flambe’).
c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate for the size of the surface element.
WARNING
WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE
FIRE, OBSERVE THE FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn o the burner. BE
CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE
FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN – You may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.
d) Use an extinguisher ONLY if:
1) You know you have a Class ABC extinguisher, and you already know how to operate it.
2) The fire is small and contained in the area where it started.
3) The fire department is being called.
4) You can fight the fire with your back to an exit
Based on “Kitchen Firesafety Tips” published by NFPA.
6
Verona Use, Care, and Installation Guide
Safety Information
ZEPHYRONLINE.COM
READ AND SAVE THESE INSTRUCTIONS
WARNING
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all
applicable codes and standards, including fire-rated construction.
b) Sucient air is needed for proper combustion and exhausting of gases through the flue (chimney)
of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s
guideline and safety standards such as those published by the National Fire Protection Association
(NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden
utilities.
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be marked as appropriate for the
application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
WARNING
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
Verona Use, Care, and Installation Guide
7
CORE
Safety Information
VERONA
READ AND SAVE THESE INSTRUCTIONS
CAUTION
Ź To reduce risk of fire and to properly exhaust air outside, do not vent exhaust air into spaces within
walls, ceilings, attics, crawl spaces, or garages.
Ź Not for use over an outdoor grill.
Ź For indoor use only.
WALL
Operation
Ź Always leave safety grilles and filters in place. Without these components, operating blowers could
catch onto hair, fingers and loose clothing.
Ź The manufacturer declines all responsibility in the event of failure to observe the instructions given
here for installation, maintenance and suitable use of the product. The manufacturer further
declines all responsibility for injury due to negligence and the warranty of the unit automatically
expires due to improper maintenance.
NOTE: Please check www.zephyronline.com for revisions before doing any custom work.
Electrical Requirements
Important:
Observe all governing codes and ordinances.
It is the customer’s responsibility to be aware of these below:
Ź To contact a qualified electrical installer.
Ź To assure that the electrical installation is adequate and in conformance with National Electrical
Code, ANSI/NFPA 70 latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1
and C22.2 No.0-M91 - latest edition** and all local codes and ordinances.
8
Verona Use, Care, and Installation Guide
Safety Information
ZEPHYRONLINE.COM
READ AND SAVE THESE INSTRUCTIONS
Ź If codes permit and a separate ground wire is used, it is recommended that a qualified electrician
determine that the ground path is adequate.
Ź Do not ground to a gas pipe.
Ź Check with a qualified electrician if you are not sure the range hood is properly grounded.
Ź Do not have a fuse in the neutral or ground circuit.
Ź This appliance requires a 120V 60Hz electrical supply and connected to an individual properly
grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring
must be 2 wire with ground. Please also refer to Electrical Diagram on product.
Ź A cable locking connector (not supplied) might also be required by local codes. Check with local
requirements, purchase and install appropriate connector if necessary.
* National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575
WARNING
Prop. 65 Warning for California Residents: This product may
contain chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
A minimum of 8” round duct is recommended to maintain maximum air flow eciency.
Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%.
Use calculation worksheet to compute total duct work (Page 11).
ALWAYS, when possible, reduce the number of transitions and turns. If a long duct run is required,
increase duct size from 8” to 10”.
If turns or transitions are required: Install as far away from duct opening and as far apart between
the two transitions as possible.
Minimum mount height between range top to hood bottom should be no less than 24”.
Maximum mount height should be no higher than 34”.
It is important to install the hood at the proper mounting height. Hoods mounted too low could result
in heat damage and fire hazard; while hoods mounted too high will be hard to reach and will loose its
performance and eciency.
If available, also refer to range manufacturer’s height clearance requirements and recommended
hood mounting height above range. Always check your local codes for any dierences.
Duct cover extension kit available for ceiling heights up to 12 feet. Turn to the List of Parts and
Accessories section for part number and ordering information.
For shipment and installation damages:
Ź Please fully inspect unit for damage before installation.
Ź If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or
replacement.
Ź If the unit is damaged by the customer, repair or replacement is the responsibility of the customer.
Ź If the unit is damaged by the installer (if other than the customer), repair of replacement must be
made by arrangement between customer and installer.
Verona Use, Care, and Installation Guide
13
CORE
Installation Instructions
VERONA
Ducting Options
WARNING
Fire Hazard: NEVER exhaust air or terminate ductwork into
spaces between walls, crawl spaces, ceilings, attics, or garages.
All exhaust must be ducted to the outside, unless using the
recirculating option.
Ź Use single wall rigid metal ductwork only.
Ź Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct
Tape.
roof pitch w/
flashing & cap
WALL
(blower
housing)
(blower
housing)
ductless
recirculating
(blower
housing)
Sot or crawl space
side wall cap
w/ gravity damper
side wall cap
w/ gravity damper
(blower
housing)
14
Verona Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Ů
Installation Instructions
Front of Hood
12-13/16”
11-13/16”
23-3/16”
29-15/16”, 35-7/16”
6-1/4”
14-3/16”
2-5/8”
Side of Hood
12-13/16”
22-1/16”
STANDARD
min. ducted - 26min. recirc. - 31”
max. - 50”
Electrical wiring must be done by qualified person(s) in
accordance with all applicable codes and standards. Turn o
electrical power at service entrance before wiring.
For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not
use extension cord or adapter plug with this appliance.
Follow national electrical codes or prevailing local codes and ordinances.
This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly
grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring
must be 2 wire w/ ground. Please also refer to the Electrical Diagram labeled on product.
Cable Lock
A cable locking connector (not supplied) might be required by local codes. Check with local
requirements and codes, purchase and install appropriate connector if necessary. (FIG. A)
2
Cable Lock
1
3
Motor Housing
16
FIG. A
Verona Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Mounting the Hood
CAUTION
At least two installers are required due to the
weight and size of the hood.
Installation Instructions
C/L
Duct Cover
11-1/8”
B
Bracket
1. Measure from range top to hood bottom and
mark line A. (24” minimum from range top) .
2. Plum and mark center line.
3. Mark mounting height line B. (14-3/4” from line
A)
4. Mark mounting spread from C/L. (11-1/8”)
5. Fasten (2) #6 x 1-1/2” screws into studs on line B
but do not tighten all the way.
NOTE: Wood blocking may need to be added
behind the drywall if no studs are present. Wall
anchors may also be used but check local
codes for compliance. Failure to use suitable
wall anchors and screws to hold the weight
of the hood could result in personal injury or
damage to cooking surface or counter.
6. Remove tape and (2) screws securing
electronics mounting bracket to hood.
Reposition electronics mounting bracket as
shown in FIG. A3 and secure to motor housing
using the (2) previously removed screws.
14-3/4”
A
24” min.
C/L
Brackets are
pre-installed
1
2
FIG. B
Verona Use, Care, and Installation Guide
17
CORE
Installation Instructions
VERONA
WALL
Mounting the Hood
7. Remove (2) screws securing electrical junction box to electronics mounting plate. Remove junction
box shown in FIG. A1.
8. Remove the (2) aluminum mesh filter.
9. Hang hood onto the mounting screws and hand tighten each screw. (FIG. B) Secure third #6 x
1-1/2” screw through inside of hood into wall for extra support shown in FIG. B2.
10. Center and attach duct cover mounting bracket to wall just below the ceiling or sot using (2) #6
x 1” screws.
11. Install duct work and seal duct work with aluminum duct tape. Reinstall electrical junction box with
cable lock and install the electrical shown in FIG. A2.
12. Power up hood and check for leaks around duct tape.
13. Place telescopic duct covers onto hood and extend inner (top) duct cover upwards and secure to
duct cover bracket using (2) M3.5 x 8 screws.
* If using hood in recirculating mode you must secure the air diverter plate onto wall before installing
duct work and duct covers. Turn to the Ductless Recirculation section for more details.
18
Verona Use, Care, and Installation Guide
Installation Instructions
ZEPHYRONLINE.COM
Ductless Recirculation
Ductless recirculation is intended for applications where an exhaust duct work is not possible to be
installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood.
Fumes and exhaust from cooking are drawn and filtered by a set of optional charcoal filters. The air is
then purified and re-circulated back within the home.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new
duct work, if possible. The hood is most eective and ecient as an exhaust hood. Only when the
exhaust option is not possible should you recourse to converting the hood into a recirculating hood.
When converted to be a recirculating hood, a set of charcoal filters are required on top of its standard
Metal Filter set. Order according to its part number below. The standard mesh filters are intended to
capture residue from cooking, and the optional charcoal filters help to purify fumes exhausted from
cooking for recirculation.
Recirculating Kit Installation (required if no ducting is used)
Kit includes the charcoal filters and the air diverter plate.
Hood ModelPart NumberFilters in Package
ZVO-E30BGZRC-00VO2
ZVO-M90BGZRC-00VO2
1. Purchase recirculating kit per the part number above.
2. Secure air diverter plate to wall below duct cover bracket. (FIG. C) Run 8” ducting from top of
hood and secure to air diverter plate. See manual included with recirculating kit for more detailed
instructions.
3. Remove aluminum mesh filter from hood. Install charcoal filter bracket inside filter opening. Note:
screws to secure charcoal filter bracket are already pre-installed in the hood and must first be
removed. Clip charcoal filters onto charcoal filter bracket. (FIG. C)
4. Re-Install aluminum mesh filters.
Verona Use, Care, and Installation Guide
19
CORE
Installation Instructions
5. Enable charcoal filter change indicator on
control panel. (Refer details to pg. 22)
6. Charcoal filters must be replaced after every
120 hours of use (or approximately every 3 to
4 months based on the average of 1 - 2 hours
of daily cooking time). The microprocessor in
the controls when set, will elapse and count
usage time and indicate when charcoal filter
replacement is required every 120 hours.
Charcoal Filter Replacements
VERONA
WALL
Hood ModelPart Number
ZVO-E30BGZ0F-C0022
ZVO-M90BGZ0F-C0022
DO NOT WASH CHARCOAL FILTERS. Charcoal
filters may need to be changed more often
depending on cooking habits.
- Button will turn power on and o for entire hood (fan and lights).
- Hood will remember the last speed and light level it was turned o at.
(Example: Press Button to turn o hood when on fan speed 4 and high lights.
Press Button again and the hood will turn back on at speed 4 and high lights
level.)
Delay O Button Function
- With the fan on press and hold the Button for two seconds. The fan will change
to speed 1 and the 5 minute delay o timer will start.
+ LEDs will illuminate and slowly blink in
accordance with the time remaining until the fan and lights automatically turn
o.
- Pressing Button while Delay O Function is enabled will turn the hood o and
cancel the Delay O Function.
Adjust 5 Speed Levels
Lights Low/High/O
ACT™ Verification
- Airflow Control Technology (ACT™) allows the installer to set the maximum fan
CFM to align with local codes and regulations.
- To verify the maximum fan CFM:
- With hood o, hold the Button for two seconds. If all five fan speed
indicators illuminate = default maximum CFM. If four fan speed indicators
illuminate = 390 maximum CFM. If 3 fan speed indicators illuminate = 290
maximum CFM.
2 SPEED SELECTION BUTTON
Fan Speed Decrease Button
- Press this button to decrease fan speed. 5, 4, 3, 2, 1.
- If fan is On Speed 1 and this button is pressed, fan will power O.
Fan Speed Increase Button
- Press this button to increase fan speed. Fan On, 1, 2, 3, 4, 5.
- If hood is O and this button is pressed, fan will turn On Speed 1.
ACT™ Enabled Speed Selections
- When ACT™ is enabled, the number of fan speeds will be reduced as follows:
- 390 CFM = Maximum 4 speeds
- 290 CFM = Maximum 3 speeds
Verona Use, Care, and Installation Guide
21
CORE
Features & Controls
ICON Touch Controls
3 LIGHTS BUTTON
- Lights have two levels, Low and High.
- From o, press one time for Low. Press again for High. Press again to power lights
o.
4 DISPLAY INDICATORS
Charcoal Filter Replace Indicator (disabled by default, must be enabled if
recirculating hood)
- To enable Charcoal Filter Replacement Reminder:
- With hood o, hold button and button simultaneously for two seconds.
All LED indicators will illuminate for three seconds confirming the Charcoal
Filter Replace Reminder is enabled.
- To disable Charcoal Filter Replacement Reminder:
- With hood o, hold button and button simultaneously for two seconds.
All LED indicators will blink two times confirming the Charcoal Filter Replace
Reminder is disabled.
- After 120 hours of fan usage the button will slowly blink indicating the
charcoal filters need replacment.
- To reset: With hood o, hold the button for two seconds. All LED indicators will
blink two times confirming the 120 hour timer has been reset.
VERONA
WALL
22
Verona Use, Care, and Installation Guide