Zephyr ZRC-0700, ZRC-0736, ZRC-0742 Installation Manual

Page 1
www.zephyronline.com
Installation Guide
Tempest Recirculating Kit
ZRC-0700 ZRC-0736 ZRC-0742
NOV18.0301 © Zephyr Ventilation LLC.
READ AND SAVE THESE INSTRUCTIONS
Page 2
MODELS: ZRC-0700, ZRC-0736, ZRC-0742
PARTS SUPPLIED
1 - Air diverter box
2 - Carbon lter cartidges (3 for ZRC-0742) 2 - Carbon lter adapters (3 for ZRC-0742) 1 - Hardware package
HARDWARE PACKAGE CONTENTS
www.zephyronline.com
List of Materials
#6 x 1” (4)
3/16 x 3/8” (4)
M4 x 8 (4)
PARTS NOT SUPPLIED
- Ducting, conduit and all installation tools
- Cable connector (if required by local codes)
REPLACEMENT PARTS
DESCRIPTION PART #
Replacement Parts
Charcoal Filter (each) Z0F-C002
To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368
Page 3
Top
1
27
or
"
4
1
"
33
4
3
or
39
"
16
9
"
2
16
3
1
"
8
7
"
8
7
9
"
2
16
3
1
"
16
1
"
2
Installation – Specications
Front
4"
15
or
"
29
16
15
35
16
or
"
15
"
41
16
Side
12"
Page 4
Mounting the air diverter box
FOR USE WITH AK7000BS, AK7500BS, AK7036BS,
AK7536BS, AK7042BS and AK7542BS ONLY
FOR USE WITH SINGLE INTERNAL BLOWER ONLY
NOT COMPATIBLE WITH DUAL INTERNAL BLOWER
1. Position the air diverter box under cabinet. Mark the (4) key­holes for the #6 x 1” screws and electrical knock out opening with a pencil. Remove air diverter box and install the (4) #6 x 1” screws. Do not tighten screws all the way. Drill out the electrical knock-out opening. Note: Reinforce cabinet with 1” x 2” wood strips if additional strengthening is required or if cabinets are framed.
2. Lift air diverter box and align the holes on top of the air diverter box with the screws recently installed. Slide the air diverter box towards the wall to temporarily lock in place. Hand tighten the (4) screws. (Fig. A)
3. Lift Tempest I range hood and align the key-holes on top of the hood with the screws protruding from the bottom of the air diverter box. Slide hood towards wall to temporarily lock in place. Hand tighten the (4) screws. (Fig. A) Note: Electrical wiring will pass through the cabinet bottom, air diverter box and connect to the hood wiring. See Tempest I instruction manual for more details.
4. Further secure the hood to the air diverter box by fastening M4 x 8 screws and 3/16 x 3/8” screws to each of the (8) holes on the bottom of the air diverter box. You can gain access to the screw holes from within the hood. The holes on
Installation – Mounting the Diverter Box
top of the Tempest I will align with the holes on the bottom of the air diverter box. (Fig. B)
www.zephyronline.com
(4) M4 x 8 screws go here
(4) 3/16 x 3/8” screws go here
Fig. B
Fig. A
Page 5
Mounting the Bracket and Bafe Filter
1. Insert the charcoal lter bracket into back side of bafe lter (side without handles). The (2) tabs on the bottom of the bracket should be inserted into the bafe lter rst. Push the bracket towards the bafe lter to lock bracket in place. There is a clip on top of the bracket that will secure it to the bafe lter. (Fig. C) Repeat this step for each bracket.
clip
tab
tab
Fig. C
Mounting the Bracket and Charcoal Filter
1. First insert the tab cut out on the charcoal lter onto either side of the tab insert on the bracket, then clip the self locking tabs onto the bracket.
2. Insert the charcoal lter into the bracket. Tab cut-out side of the charcoal lter should be installed rst then push down on the lter to lock in place. (Fig. D)
Installation – Charcoal Filters and Brackets
Fig. D
Loading...