Zephyr ZOM-E30BS, ZOM-E30BBS, ZOM-E36BS, ZOM-E36BBS Specification Sheet

CORE
TM
C
OMBRA
WALL
Min. - Max. CFM
Min. - Max. Sones
INTERNAL BLOWER
STANDARD
200 - 600
1 - 6
INTERNAL BLOWER with ACT™
AIRFLOW CONTROL TECHNOLOGY™*
200 - 390
1 - 4
*AIRFLOW CONTROL TECHNOLOGY™ (ACT™)
is an exclusive feature built into specic Zephyr hoods which can limit the maximum blower CFM to meet local code requirements.
200 - 290
1 - 3
ZEPHYRONLINE.COM
8 3/4”
12”
Stainless Steel
Black Stainless Steel
FRONT
6 7/8”
Standard
min. ducted - 30” min. recirc - 32” max. 42 1/2”
Z1C-01OMS Z1C-01OMBS
min. ducted - 46 1/2” min. recirc. - 50 1/2”
1 9/16”
max. 80”
19 3/4”
SIDE
6”
7/8”
TOP
CORE
TM
C
OMBRA
WALL
MODEL
Stainless Steel Black Stainless Steel
Size Blower CFM (Min. - Max.) Sones (Min. - Max.) ACT 390 CFM (Min. - Max.) ACT 390 Sones (Min. - Max.) ACT 290 CFM (Min. - Max.) ACT 290 Sones (Min. - Max.)
FEATURES ACT™ Technology Controls Speed Levels
Auto Delay-O
Lighting Dual-Level Lighting Filters Recirculating Option Duct Cover Extension Option
ZOM-E30BS ZOM-E30BBS
30” 200 - 600 1 - 6 200 - 390 1 - 4 200 - 290 1 - 3
Yes
Capacitive Touch 4*
Yes
LumiLight LED, 6W x2
Yes
Aluminum Mesh x2
Yes
Yes, Up to 12’ Ceiling
ZEPHYRONLINE.COM
ZOM-E36BS ZOM-E36BBS
36” 200 - 600 1 - 6 200 - 390 1 - 4 200 - 290 1 - 3
Yes
Capacitive Touch 4*
Yes
LumiLight LED, 6W x2
Yes
Aluminum Mesh x2
Yes
Yes, Up to 12’ Ceiling
DUCT SPECIFICATIONS Vertical Internal Blower Horizontal Internal Blower AC POWER
6” Round
NA
120V, 60Hz at Max. 4A
6” Round
NA
120V, 60Hz at Max. 4A
OPTIONAL ACCESSORIES Recirculating Kit Duct Cover Extension
ZRC-01OM Z1C-01OMS (ss) Z1C-01OMBS (black ss)
Hybrid Bae Filter Kit
Make-Up Air Kit
MOUNTING HEIGHT RANGE**
WARRANTY
CEILING HEIGHT
STANDARD DUCT COVER
DUCT COVER EXTENSION
*When ACT™ is enabled the maximum speed levels will change. ACT 390 CFM = 3 speeds and ACT 290 CFM = 2 speeds. **Mounting height refers to distance between top of a 36” tall cooking surface and bottom of hood.
Ducted Mounting Height**
Recirc Mounting Height**
Ducted Mounting Height**
Recirc Mounting Height**
Z0F-B002 MUA006A
24” - 34”
3 years parts, 1 year labor
8’
26” - 30”
26” - 28”
NA
NA
ZRC-01OM Z1C-01OMS (ss) Z1C-01OMBS (black ss) Z0F-B002 MUA006A
24” - 34”
3 years parts, 1 year labor
8.5’
26” - 34”
26” - 34”
NA
NA
9’
29.5” - 34”
29.5” - 34”
NA
NA
9.5 ’
NA
NA
26” - 31.5”
NA
10’
NA
NA
26” - 34”
NA
10.5’
NA
NA
26” - 34”
26” - 29.5”
11’
NA
NA
26” - 34”
26” - 34”
12’
NA
NA
28” - 34”
28” - 34”
AIRFLOW CONTROL TECHNOLOGY™ (ACT™)
is an exclusive feature built into specic Zephyr hoods which can limit the maximum blower CFM to meet local code requirements.
Specications subject to change, check zephyronline.com for up-to-date information. Zephyr Ventilation | 2277 Harbor Bay Parkway, Alameda, CA 94502 | 888.880.VENT
FEB21.0101
Loading...